Chris P. Geffre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chris P. Geffre has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
David S. Margolis
Department of Orthopaedic Surgery, University of Arizona, Tucson, Arizona, USA
4 shared publicationsJohn A. Szivek
4 shared publicationsCody L. Bliss
2 shared publicationsDonald W. DeYoung
University Animal Care, University of Arizona, Tucson, Arizona
2 shared publicationsJohn T. Ruth
Department of Orthopaedic Surgery, Orthopaedic Research Laboratory, University of Arizona, Tucson, Arizona
2 shared publicationsBrandi C. Tellis
Department of Orthopaedic Surgery, Orthopaedic Research Laboratory, University of Arizona, Tucson, Arizona
1 shared publication
Latest Publications
- 30 June 2010
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 23 (3) , 156-162
Load Measurement Accuracy from Sensate Scaffolds with and without a Cartilage Surface
The use of "sensate" scaffolds covered with tissue-engineered cartilage has emerged as a possible treatment option for focal articular cartilage defects. The ability to monitor joint loading provides several benefits that can be useful in both clinical and research situations. Previous studies have shown that these scaffolds can accurately monitor in vivo joint loading during various activities. However, the effect that an articular cartilage layer or soft tissue overgrowth has on scaffold sensitivity has not been tested. Eight scaffolds were tested with cartilage samples taken from four hounds. Three strain gauges were attached to each scaffold and a servo hydraulics system was used to test sensitivity while the scaffold was in contact with cartilage, metal, or silicone surfaces. Strain gauge sensitivity was calculated from load and strain measurements collected during testing. There was no significant difference between the mean strain gauge sensitivities when the scaffolds were in contact with the different surfaces: cartilage 30.9 +/- 16.2 muepsilon/N, metal 31.8 +/- 18.6 muepsilon/N, and silicone 30.6 +/- 12.3 muepsilon/N. These results indicate that "sensate" scaffolds can be calibrated and used to monitor load with the presence of an articular cartilage layer.
- 30 June 2010
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 23 (3) , 156-162
Load Measurement Accuracy from Sensate Scaffolds with and without a Cartilage Surface
The use of "sensate" scaffolds covered with tissue-engineered cartilage has emerged as a possible treatment option for focal articular cartilage defects. The ability to monitor joint loading provides several benefits that can be useful in both clinical and research situations. Previous studies have shown that these scaffolds can accurately monitor in vivo joint loading during various activities. However, the effect that an articular cartilage layer or soft tissue overgrowth has on scaffold sensitivity has not been tested. Eight scaffolds were tested with cartilage samples taken from four hounds. Three strain gauges were attached to each scaffold and a servo hydraulics system was used to test sensitivity while the scaffold was in contact with cartilage, metal, or silicone surfaces. Strain gauge sensitivity was calculated from load and strain measurements collected during testing. There was no significant difference between the mean strain gauge sensitivities when the scaffolds were in contact with the different surfaces: cartilage 30.9 +/- 16.2 muepsilon/N, metal 31.8 +/- 18.6 muepsilon/N, and silicone 30.6 +/- 12.3 muepsilon/N. These results indicate that "sensate" scaffolds can be calibrated and used to monitor load with the presence of an articular cartilage layer.
- 30 June 2010
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 23 (3) , 134-141
Evaluation of the Osteogenic Performance of Calcium Phosphate-Chitosan Bone Fillers
There has been recent interest in utilizing calcium phosphates (CaPs) that set in situ for treating bone defects due to the limitations associated with morselized autografts and allografts. However, CaP cements have long setting times, poor mechanical properties, and poor osteoinductivity. This has prompted research toward finding a nonprotein-based compound, such as chitosan, to accelerate setting times and increase osteoinductivity. The purpose of this study was to compare bone growth rates during the early bone healing response achieved using conventionally prepared chitosan-CaP bone filler to an extensively purified chitosan-CaP compound. Both compounds set quickly and stimulated bone formation. Histomorphometry demonstrated a 290% increase in new bone formation when using the conventional chitosan-CaP bone filler and a 172% increase with the highly purified chitosan-CaP compound compared to the increase in bone formation seen with the unfilled control group. The results of this study indicate that a highly purified chitosan-CaP paste stimulated less bone formation than a conventionally prepared chitosan-CaP paste but both pastes have the potential to stimulate bone formation.
- 30 June 2010
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 23 (3) , 134-141
Evaluation of the Osteogenic Performance of Calcium Phosphate-Chitosan Bone Fillers
There has been recent interest in utilizing calcium phosphates (CaPs) that set in situ for treating bone defects due to the limitations associated with morselized autografts and allografts. However, CaP cements have long setting times, poor mechanical properties, and poor osteoinductivity. This has prompted research toward finding a nonprotein-based compound, such as chitosan, to accelerate setting times and increase osteoinductivity. The purpose of this study was to compare bone growth rates during the early bone healing response achieved using conventionally prepared chitosan-CaP bone filler to an extensively purified chitosan-CaP compound. Both compounds set quickly and stimulated bone formation. Histomorphometry demonstrated a 290% increase in new bone formation when using the conventional chitosan-CaP bone filler and a 172% increase with the highly purified chitosan-CaP compound compared to the increase in bone formation seen with the unfilled control group. The results of this study indicate that a highly purified chitosan-CaP paste stimulated less bone formation than a conventionally prepared chitosan-CaP paste but both pastes have the potential to stimulate bone formation.
- 2 December 2008
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 91A (3) , 795-805
A novel biomimetic polymer scaffold design enhances bone ingrowth
There has been recent interest in treating large bone defects with polymer scaffolds because current modalities such as autographs and allographs have limitations. Additionally, polymer scaffolds are utilized in tissue engineering applications to implant and anchor tissues in place, promoting integration with surrounding native tissue. In both applications, rapid and increased bone growth is crucial to the success of the implant. Recent studies have shown that mimicking native bone tissue morphology leads to increased osteoblastic phenotype and more rapid mineralization. The purpose of this study was to compare bone ingrowth into polymer scaffolds created with a biomimetic porous architecture to those with a simple porous design. The biomimetic architecture was designed from the inverse structure of native trabecular bone and manufactured using solid free form fabrication. Histology and μCT analysis demonstrated a 500–600% increase in bone growth into and adjacent to the biomimetic scaffold at five months post‐op. This is in agreement with previous studies in which biomimetic approaches accelerated bone formation. It also supports the applicability of polymer scaffolds for the treatment of large tissue defects when implanting tissue‐engineering constructs. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
- 2 December 2008
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 91A (3) , 795-805
A novel biomimetic polymer scaffold design enhances bone ingrowth
There has been recent interest in treating large bone defects with polymer scaffolds because current modalities such as autographs and allographs have limitations. Additionally, polymer scaffolds are utilized in tissue engineering applications to implant and anchor tissues in place, promoting integration with surrounding native tissue. In both applications, rapid and increased bone growth is crucial to the success of the implant. Recent studies have shown that mimicking native bone tissue morphology leads to increased osteoblastic phenotype and more rapid mineralization. The purpose of this study was to compare bone ingrowth into polymer scaffolds created with a biomimetic porous architecture to those with a simple porous design. The biomimetic architecture was designed from the inverse structure of native trabecular bone and manufactured using solid free form fabrication. Histology and μCT analysis demonstrated a 500–600% increase in bone growth into and adjacent to the biomimetic scaffold at five months post‐op. This is in agreement with previous studies in which biomimetic approaches accelerated bone formation. It also supports the applicability of polymer scaffolds for the treatment of large tissue defects when implanting tissue‐engineering constructs. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
- 7 June 2007
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 84B (1) , 263-270
Sensate scaffolds coupled to telemetry can monitorin vivo loading from within a joint over extended periods of time
- 7 June 2007
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 84B (1) , 263-270
Sensate scaffolds coupled to telemetry can monitorin vivo loading from within a joint over extended periods of time