XXXiaoming Xu

Xiaoming Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaoming Xu has a total of 61 co-authors. Here are the top co-authors by number of shared publications:

  • John O. Burgess

    Department of Comprehensive Dentistry and Biomaterials, Louisiana State University Health Sciences Center, School of Dentistry, 1100 Florida Avenue, New Orleans, Louisiana 70119

    6 shared publications
  • Yapin Wang

    Department of Comprehensive Dentistry & Biomaterials, School of Dentistry, Louisiana State University Health-New Orleans, New Orleans, Louisiana, USA

    6 shared publications
  • Paul Armbruster

    Department of Orthodontics , LSUHSC School of Dentistry , New Orleans, LA USA

    5 shared publications
  • Qingzhao Yu

    School of Public Health, Louisiana State University Health Sciences Center-New Orleans (LSUHSC-NO), New Orleans, LA 70112, USA

    5 shared publications
  • Richard W. Ballard

    Department of Orthodontics , LSU Health Sciences Center , New Orleans , LA , USA

    5 shared publications
  • Yuwei Fan

    Restorative Sciences & Biomaterials, Boston University Henry M. Goldman School of Dental Medicine, Boston, MA, USA

    5 shared publications

Latest Publications

  • Open Access

    Bond Strength of Reline Materials to 3D-Printed Provisional Crown Resins

    by Jorge Palavicini, Sherrod L. Quin, Wael Zakkour, Karim Zakkour, Safa Manafi Varkiani, Xiaoming Xu, Nathaniel C. Lawson, Amir Hossein Nejat

    (1) Purpose: The aim of the present study was to compare the bond strength between two 3D-printed resins designed for long-term provisional crowns and three different reline materials. (2) Materials and Methods: Rectangular specimens were prepared from two 3D-printed resins (Envision Tech and NextDent C&B) and a conventional self-cure PMMA. Transparent tubes filled with three different reline materials including composite resin, Bis-acryl, and PMMA were bonded to the 3D-printed specimens (n = 11 per group, total of 6 study groups). Tubes filled with PMMA were bonded to the prepared PMMA specimens which served as the control group (n = 11, control group). The specimens were subjected to a shear bond strength (SBS) test, and mode of failure was recorded using light microscopy. Statistical analysis was performed using a one-way ANOVA and post hoc Tukey’s tests (alpha = 0.05). (3) Results: The highest SBS value was achieved to both 3D-printed materials with the PMMA reline material. The bond to both 3D-printed materials was lower with Bis-acrylic or composite resin relines in comparison to that with PMMA (p-value < 0.05). No significant difference was found between the control PMMA group and either 3D-printed material when relined with PMMA (p-value > 0.05). (4) Conclusion: The tested 3D-printed resins achieved a clinically acceptable bond strength when relined with PMMA.


  • Open Access

    Bond strength of orthodontic brackets using the anti-bacterial primer, Denteshield ®

    by Craig Murphy, Xiaoming Xu, Qingzhao Yu, Paul Armbruster, Richard Ballard

    Aim: This study examined the bond strength associated with Denteshield ® Primer as a replacement for a conventional, non-antimicrobial, orthodontic primer. Materials/methods: Sixty human premolar teeth were divided into three groups ( n =20). Each group was assigned to receive either Denteshield ® , Pro Seal ® or Transbond XT TM primer. Light-cured Transbond XT TM adhesive resin was utilised to bond a bracket to each sample tooth following the application of the assigned primer. Ten samples from each group were tested for shear bond strength using a universal testing machine. The remaining 10 samples from each group underwent bracket debonding using a debonding plier. Applying an adhesive remnant index, each sample was scored under a microscope at 2.5× magnification. The data were analysed using One-way ANOVA, the Tukey post hoc test and the Kruskal–Wallis test. Results: The mean shear bond strength (MPa) of the three groups was: Denteshield ® (33.18 ± 13.56), Pro Seal ® (23.68 ± 12.04) and Transbond XT TM primer (26.19 ± 9.44). There was no significant difference in the shear bond strength across all three groups ( p = 0.19). The adhesive remnant index results also showed no significant differences between the three groups ( p = 0.278). Conclusion: Based on the shear bond strengths obtained in this study and the previously reported values necessary for clinical use, all three primers appear adequate for clinical use. (Aust Orthod J 2022; 39: 49 - 54. DOI: 10.2478/aoj-2023-0009)

  • Open Access

    Bond strength of orthodontic brackets using the anti-bacterial primer, Denteshield®

    by Craig Murphy, Xiaoming Xu, Qingzhao Yu, Paul Armbruster, Richard Ballard

    Sciendo provides publishing services and solutions to academic and professional organizations and individual authors. We publish journals, books, conference proceedings and a variety of other publications.

  • Open Access

    A comparison of shear bond strength of brackets bonded to zirconia

    by Hannah Knott, Xiaoming Xu, Edwin Kee, Qingzhao Yu, Paul Armbruster, Richard Ballard

    Purpose: The objective of this study was to compare the shear bond strength (SBS) of ceramic orthodontic brackets bonded to highly translucent zirconia surfaces following the use of two different primers. Materials and methods:<Three types of highly translucent zirconia crowns, Cercon xt ML, e.max ZirCAD, and STML-ML Katana Zirconia, were milled, sandblasted, and primed using two zirconia primers, Monobond Etch and Prime and Z-Prime Plus. A ceramic bracket (Radiance) was bonded onto the facial surface of each crown. Shear bond strength was evaluated using a universal testing machine. Results: There was no significant overall difference across the six experimental groups regarding shear bond strength. The use of the two tested zirconia primers resulted in comparable and clinically acceptable shear bond strengths. Conclusions: Both tested zirconia primers were associated with adequate bond strength when bonding a ceramic orthodontic bracket to the three highly translucent zirconia substrates.


    • 15 November 2018
      • Vol. 31, 17B-23B

    Synthesis, antibacterial activity, and biocompatibility of new antibacterial dental monomers.

    by Yapin Wang, Stephen Costin, Jian-Feng Zhang, Sumei Liao, Zezhang T Wen, Thomas Lallier, Qingzhao Yu, XiaoMing Xu

    To synthesize a small library of antibacterial dental monomers based on quaternary ammonium salts and to test their antibacterial activity against cariogenic bacteria. Five new antibacterial monomers were synthesized and characterized by NMR, IR and HRMS. Cytotoxicity assays using human gingival fibroblast cells showed that these new antibacterial monomers were biocompatible at concentrations of 10⁻⁵ M and displayed less cytotoxicity than BisGMA, a common dental monomer. When analyzed in vitro, all new monomers demonstrated strong inhibitory activity against biofilm formation by cariogenic Streptococcus mutans and Lactobacillus casei. Results indicated that antibacterial monomers containing a long alkyl (i.e. hexadecyl) chain are superior to their shorter-chain counterparts. The cross-linking monomers based on glycerol dimethacrylate also consistently outperformed their monomethacrylate analogs. Finally, the ammonium salts containing the dimethylbenzyl moiety were superior to the similar structures containing 1,4-diazabicyclo[2.2.2]octane (DABCO) in some cases. All five new monomers were deemed biocompatible at concentrations of 10⁻⁵ M or less, and most had better biocompatibility than BisGMA. Dimethacrylate monomers 5 and 6 generally demonstrated high antibacterial activities, with the highest activity shown for the most lipophilic monomer 6, and these new antibacterial monomers have potential future application in dental composites and bonding agents.


  • Open Access

    Mechanical and Physical Properties of Experimental Antifungal Denture Base Resins

    by Kyle Maldonado, David Xu, Yapin Wang, Jian-Feng Zhang, Suleiman Hamdan, Zezhang T. Wen, Paul L. Fidel Jr, Mairi C. Noverr, Xiaoming Xu


  • Fabrication and characterization of a glucose-sensitive antibacterial chitosan–polyethylene oxide hydrogel

    by Yu Xiao, Tao Gong, Ying Jiang, Yapin Wang, Zezhang T. Wen, Shaobing Zhou, Chongyun Bao, Xiaoming Xu


  • Antibacterial Dental Composites with Chlorhexidine and Mesoporous Silica

    by J.F. Zhang, R. Wu, Y. Fan, S. Liao, Y. Wang, Z.T. Wen, X. Xu

    One of the leading causes for the failure of dental composite restorations is secondary caries. Effectively inhibiting cariogenic biofilms and reducing secondary caries could extend the service life of composite restorations. Dental composites releasing antibacterial agents such as chlorhexidine (CHX) have shown biofilm-inhibitory efficacy, but they usually have poor physical and mechanical properties. Herein, we present a study of a new method to encapsulate and release CHX from dental composite using mesoporous silica nanoparticles (MSNs). SBA-15 MSNs were synthesized according to a reported procedure. CHX (62.9 wt%) was encapsulated into dried MSN from 0.3 M CHX ethanol solution. The dental composites containing 0% (control), 3%, 5%, and 6.3% CHX or the same amounts of CHX entrapped in MSN (denoted as [email protected]) were fabricated with methacrylate monomers and silanized glass fillers (CHX or [email protected] + glass filler particle = 70 wt%). The monomer mixture consisted of bisphenol A glycidyl methacrylate (BisGMA), hexanediol dimethacrylate (HDDMA), ethoxylated bisphenol A dimethacrylate (EBPADMA), and urethane dimethacrylates (UEDMA) at a weight ratio of 40:30:20:10. The composites were tested for CHX release and recharge, flexural strength and modulus (at 24 hr and 1 mo), surface roughness, in vitro wear, and antibacterial activity against Streptococcus mutans and Lactobacillus casei (in both planktonic growth and biofilm formation). The results showed that the composites with [email protected] largely retained mechanical properties and smooth surfaces and showed controlled release of CHX over a long time. In contrast, the composites with directly mixed CHX showed reduced mechanical properties, rough surfaces, and burst release of CHX in a short time. The composites with CHX either directly mixed or in MSN showed strong inhibition to S. mutans and L. casei. This research has demonstrated the successful application of MSNs as a novel nanotechnology in dental materials to inhibit oral biofilm without sacrificing materials’ mechanical properties and surface integrity.


    • 11 October 2014
      • Vol. 36  (5) , 125-9

    In vitro fracture resistance of three commercially available zirconia crowns for primary molars.

    by Janice A Townsend, Patrick Knoell, Qingzhao Yu, Jian-Feng Zhang, Yapin Wang, Han Zhu, Sean Beattie, XiaoMing Xu

    The purpose of this study was to measure the fracture resistance of primary mandibular first molar zirconia crowns from three different manufacturers-EZ Pedo (EZP), NuSmile (NSZ), and Kinder Krowns (KK)-and compare it with the thickness of the zirconia crowns and the measured fracture resistance of preveneered stainless steel crowns (SSCs). The thickness of 20 zirconia crowns from three manufacturers were measured. The mean force required to fracture the crowns was determined. Preveneered NuSmile (NSW) SSCs were tested as a control. EZP crowns were significantly thicker in three of the six measured locations. The force required to fracture the EZP crown was significantly higher than that required for NSZ and KK. There was a positive correlation between fracture resistance and crown thickness in the mesial, distal, mesioocclusal, and distoocclusal dimensions. None of the zirconia crowns proved to be as resistant to fracture as the preveneered SSCs. Statistically significant differences were found among the forces required to fracture zirconia crowns by three different manufacturers. The increase in force correlated with crown thickness. The forces required to fracture the preveneered stainless steel crowns were greater than the forces required to fracture all manufacturers' zirconia crowns.