Julien Wegrzyn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Julien Wegrzyn has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Jean-Paul Roux
INSERM UMR 1033, Université de Lyon, Lyon, France
6 shared publications Vincent Pibarot
Service de chirurgie orthopédique du membre inférieur, pavillon T, hôpital Edouard-Herriot, hospices civils de Lyon, 5, place d'Arsonval, 69437 Lyon, France
6 shared publicationsRoland Chapurlat
5 shared publicationsOlivier Guyen
Department of Orthopedic Surgery, Pavillon T, Hôpital Edouard Herriot Lyon, France
4 shared publicationsMary L Bouxsein
Orthopedic Biomechanics Laboratory, Beth Israel Deaconess Medical Center and Harvard Medical School Boston, MA, USA
3 shared publicationsMonique E Arlot
INSERM Research Unit 831, Université de Lyon Lyon, France
3 shared publications
Latest Publications
- 27 March 2019
- Published by Morressier GmbH
1023 - Total Hip Arthroplasty for Periacetabular Metastatic Disease. An Original Technique of Reconstruction According to Harrington Classification.
INTRODUCTION: Periacetabular metastatic disease requires complex acetabular reconstruction with high risks of complication in very frail patients |
- 27 March 2019
- Published by Morressier GmbH
1023 - Total Hip Arthroplasty for Periacetabular Metastatic Disease. An Original Technique of Reconstruction According to Harrington Classification.
INTRODUCTION: Periacetabular metastatic disease requires complex acetabular reconstruction with high risks of complication in very frail patients |
- 1 November 2018
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 104 (7) , 1069-1072
Bone and parietal anterior iliac crest reconstruction for trans-iliac hernia after tricortical graft harvesting: An original technique
- 1 November 2018
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 104 (7) , 1069-1072
Bone and parietal anterior iliac crest reconstruction for trans-iliac hernia after tricortical graft harvesting: An original technique
- 22 February 2018
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (10) , 2329-2334
The tridimensional geometry of the proximal femur should determine the design of cementless femoral stem in total hip arthroplasty
Using a cementless femoral stem in total hip arthroplasty (THA), optimal filling of the proximal femoral metaphyseal volume (PFMV) and restoration of the extramedullary proximal femoral (PF) parameters (i.e., femoral offset (FO), neck length (FNL), and head height (FHH)) constitute key goals for optimal hip biomechanics, functional outcome, and THA survivorship. However, almost 30% of mismatch between the PF anatomy and implant geometry of the most widely implanted non-modular cementless femoral stem has been demonstrated in a computed tomography scan (CT scan) study. Therefore, this anatomic study aimed to evaluate the relationship between the intra- and extramedullary PF parameters using tridimensional CT scan reconstructions.
- 22 February 2018
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (10) , 2329-2334
The tridimensional geometry of the proximal femur should determine the design of cementless femoral stem in total hip arthroplasty
Using a cementless femoral stem in total hip arthroplasty (THA), optimal filling of the proximal femoral metaphyseal volume (PFMV) and restoration of the extramedullary proximal femoral (PF) parameters (i.e., femoral offset (FO), neck length (FNL), and head height (FHH)) constitute key goals for optimal hip biomechanics, functional outcome, and THA survivorship. However, almost 30% of mismatch between the PF anatomy and implant geometry of the most widely implanted non-modular cementless femoral stem has been demonstrated in a computed tomography scan (CT scan) study. Therefore, this anatomic study aimed to evaluate the relationship between the intra- and extramedullary PF parameters using tridimensional CT scan reconstructions.
- 9 September 2017
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (5) , 1051-1060
The predictive factors of secondary patellar resurfacing in computer-assisted total knee arthroplasty. A prospective cohort study
The decision to resurface the patella during total knee arthroplasty (TKA) remains controversial. This prospective cohort study aimed to evaluate the outcome and survivorship of the native patella in computer-assisted TKA (CAS TKA) implanted for primary knee osteoarthritis, and to determine the predictive factors of secondary patellar resurfacing (SPR).
- 9 September 2017
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (5) , 1051-1060
The predictive factors of secondary patellar resurfacing in computer-assisted total knee arthroplasty. A prospective cohort study
The decision to resurface the patella during total knee arthroplasty (TKA) remains controversial. This prospective cohort study aimed to evaluate the outcome and survivorship of the native patella in computer-assisted TKA (CAS TKA) implanted for primary knee osteoarthritis, and to determine the predictive factors of secondary patellar resurfacing (SPR).
- 11 November 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 507-512
Highly crosslinked polyethylene: a safe alternative to conventional polyethylene for dual mobility cup mobile component. A biomechanical validation
Dual mobility cup (DMC) consists of a cobalt-chromium (CoCr) alloy cup articulated with a polyethylene (PE) mobile component capturing the femoral head in force using a snap-fit technique. This biomechanical study was the first to evaluate and compare the generation of cracks in the retentive area of DMC mobile components made of highly crosslinked PE (XLPE) or conventional ultra-high molecular weight PE (UHMWPE). Eighty mobile components designed for a 52-mm diameter Symbol® DMC (Dedienne Santé, Mauguio, France) and a 28-mm diameter femoral head were analyzed. Four groups of 20 mobile components were constituted according to the PE material: raw UHMWPE, sterilized UHMWPE, annealed XLPE and remelted XLPE. Ten mobile components in each group were impacted with a 28-mm diameter CoCr femoral head using a snap-fit technique. The occurrence, location and area of the cracks in the retentive area were investigated using micro-CT (Skyscan 1176®, Bruker, Aarsellar, Belgium) with a 35 μm nominal isotropic voxel size by two observers blinded to the PE material and impaction or not of the mobile components. Compared to conventional UHMWPE, the femoral head snap-fit did not generate more or wider cracks in the retentive area of annealed or remelted XLPE mobile components. This biomechanical study suggests that XLPE in DMC could be a safe alternative to conventional UHMWPE regarding the generation of cracks in the retentive area related to the femoral head snap-fit.
- 11 November 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 507-512
Highly crosslinked polyethylene: a safe alternative to conventional polyethylene for dual mobility cup mobile component. A biomechanical validation
Dual mobility cup (DMC) consists of a cobalt-chromium (CoCr) alloy cup articulated with a polyethylene (PE) mobile component capturing the femoral head in force using a snap-fit technique. This biomechanical study was the first to evaluate and compare the generation of cracks in the retentive area of DMC mobile components made of highly crosslinked PE (XLPE) or conventional ultra-high molecular weight PE (UHMWPE). Eighty mobile components designed for a 52-mm diameter Symbol® DMC (Dedienne Santé, Mauguio, France) and a 28-mm diameter femoral head were analyzed. Four groups of 20 mobile components were constituted according to the PE material: raw UHMWPE, sterilized UHMWPE, annealed XLPE and remelted XLPE. Ten mobile components in each group were impacted with a 28-mm diameter CoCr femoral head using a snap-fit technique. The occurrence, location and area of the cracks in the retentive area were investigated using micro-CT (Skyscan 1176®, Bruker, Aarsellar, Belgium) with a 35 μm nominal isotropic voxel size by two observers blinded to the PE material and impaction or not of the mobile components. Compared to conventional UHMWPE, the femoral head snap-fit did not generate more or wider cracks in the retentive area of annealed or remelted XLPE mobile components. This biomechanical study suggests that XLPE in DMC could be a safe alternative to conventional UHMWPE regarding the generation of cracks in the retentive area related to the femoral head snap-fit.
- 7 April 2016
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (11) , 3448-3456
Does computer‐assisted surgery influence survivorship of cementless total knee arthroplasty in patients with primary osteoarthritis? A 10‐year follow‐up study
Purpose: Computer‐assisted surgery (CAS) has been proposed to improve the performance of total knee arthroplasty (TKA) by reducing implant mal‐position and mechanical axis mal‐alignment. However, no clinical study has been performed to evaluate whether CAS improves survivorship of cementless TKA at long‐term follow‐up. This prospective and comparative study evaluated the outcome and survivorship of a cementless rotating mobile‐bearing TKA performed with or without CAS at a minimum 10‐year follow‐up.Methods: A continuous series of 138 TKA (SCORE®, Amplitude, Valence, France) comparing 87 CAS TKA versus 51 conventional mechanical technique (MECA) TKA was prospectively included in our total joint registry.Results: At 10.5 years after implantation, 95 TKA (59 CAS and 36 MECA TKA) were evaluated. No significant difference was detected in the clinical outcome and mechanical axis between the two groups. The overall 10‐year survivorship using revision for any reason as end‐point was 91 ± 5 % without significant difference detected between the two groups [86 ± 10 % in the MECA group and 94 ± 5 % in the CAS group (n.s.)]. Using aseptic loosening as end‐point, the 10‐year survivorship was 100 % in both groups. Using secondary patellar resurfacing as end‐point, the 10‐year survivorship was significantly higher in the CAS than in MECA group (100 and 85 ± 15 %, respectively; p = 0.0039).Conclusion: With no implant aseptic loosening or mechanical failure at 10.5 years after implantation, the cementless rotating mobile‐bearing SCORE® TKA demonstrated favourable survivorship without influence of CAS. However, CAS might influence TKA survivorship by limiting secondary patellar resurfacing.Level of evidence: Therapeutic, Level II.
- 7 April 2016
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (11) , 3448-3456
Does computer‐assisted surgery influence survivorship of cementless total knee arthroplasty in patients with primary osteoarthritis? A 10‐year follow‐up study
Purpose: Computer‐assisted surgery (CAS) has been proposed to improve the performance of total knee arthroplasty (TKA) by reducing implant mal‐position and mechanical axis mal‐alignment. However, no clinical study has been performed to evaluate whether CAS improves survivorship of cementless TKA at long‐term follow‐up. This prospective and comparative study evaluated the outcome and survivorship of a cementless rotating mobile‐bearing TKA performed with or without CAS at a minimum 10‐year follow‐up.Methods: A continuous series of 138 TKA (SCORE®, Amplitude, Valence, France) comparing 87 CAS TKA versus 51 conventional mechanical technique (MECA) TKA was prospectively included in our total joint registry.Results: At 10.5 years after implantation, 95 TKA (59 CAS and 36 MECA TKA) were evaluated. No significant difference was detected in the clinical outcome and mechanical axis between the two groups. The overall 10‐year survivorship using revision for any reason as end‐point was 91 ± 5 % without significant difference detected between the two groups [86 ± 10 % in the MECA group and 94 ± 5 % in the CAS group (n.s.)]. Using aseptic loosening as end‐point, the 10‐year survivorship was 100 % in both groups. Using secondary patellar resurfacing as end‐point, the 10‐year survivorship was significantly higher in the CAS than in MECA group (100 and 85 ± 15 %, respectively; p = 0.0039).Conclusion: With no implant aseptic loosening or mechanical failure at 10.5 years after implantation, the cementless rotating mobile‐bearing SCORE® TKA demonstrated favourable survivorship without influence of CAS. However, CAS might influence TKA survivorship by limiting secondary patellar resurfacing.Level of evidence: Therapeutic, Level II.
- Open Access
- 25 October 2010
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 25 (11) , 2324-2331
Role of trabecular microarchitecture and its heterogeneity parameters in the mechanical behavior of ex vivo human L3 vertebrae
Low bone mineral density (BMD) is a strong risk factor for vertebral fracture risk in osteoporosis. However, many fractures occur in people with moderately decreased or normal BMD. Our aim was to assess the contributions of trabecular microarchitecture and its heterogeneity to the mechanical behavior of human lumbar vertebrae. Twenty-one human L3 vertebrae were analyzed for BMD by dual-energy X-ray absorptiometry (DXA) and microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) and then tested in axial compression. Microarchitecture heterogeneity was assessed using two vertically oriented virtual biopsies—one anterior (Ant) and one posterior (Post)—each divided into three zones (superior, middle, and inferior) and using the whole vertebral trabecular volume for the intraindividual distribution of trabecular separation (Tb.Sp*SD). Heterogeneity parameters were defined as (1) ratios of anterior to posterior microarchitectural parameters and (2) the coefficient of variation of microarchitectural parameters from the superior, middle, and inferior zones. BMD alone explained up to 44% of the variability in vertebral mechanical behavior, bone volume fraction (BV/TV) up to 53%, and trabecular architecture up to 66%. Importantly, bone mass (BMD or BV/TV) in combination with microarchitecture and its heterogeneity improved the prediction of vertebral mechanical behavior, together explaining up to 86% of the variability in vertebral failure load. In conclusion, our data indicate that regional variation of microarchitecture assessment expressed by heterogeneity parameters may enhance prediction of vertebral fracture risk. © 2010 American Society for Bone and Mineral Research.
- 25 October 2010
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 25 (11) , 2324-2331
Open AccessRole of trabecular microarchitecture and its heterogeneity parameters in the mechanical behavior of ex vivo human L3 vertebrae
Low bone mineral density (BMD) is a strong risk factor for vertebral fracture risk in osteoporosis. However, many fractures occur in people with moderately decreased or normal BMD. Our aim was to assess the contributions of trabecular microarchitecture and its heterogeneity to the mechanical behavior of human lumbar vertebrae. Twenty-one human L3 vertebrae were analyzed for BMD by dual-energy X-ray absorptiometry (DXA) and microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) and then tested in axial compression. Microarchitecture heterogeneity was assessed using two vertically oriented virtual biopsies—one anterior (Ant) and one posterior (Post)—each divided into three zones (superior, middle, and inferior) and using the whole vertebral trabecular volume for the intraindividual distribution of trabecular separation (Tb.Sp*SD). Heterogeneity parameters were defined as (1) ratios of anterior to posterior microarchitectural parameters and (2) the coefficient of variation of microarchitectural parameters from the superior, middle, and inferior zones. BMD alone explained up to 44% of the variability in vertebral mechanical behavior, bone volume fraction (BV/TV) up to 53%, and trabecular architecture up to 66%. Importantly, bone mass (BMD or BV/TV) in combination with microarchitecture and its heterogeneity improved the prediction of vertebral mechanical behavior, together explaining up to 86% of the variability in vertebral failure load. In conclusion, our data indicate that regional variation of microarchitecture assessment expressed by heterogeneity parameters may enhance prediction of vertebral fracture risk. © 2010 American Society for Bone and Mineral Research.
- Open Access
- 6 October 2010
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 26 (4) , 739-746
Determinants of the mechanical behavior of human lumbar vertebrae after simulated mild fracture
The ability of a vertebra to carry load after an initial deformation and the determinants of this postfracture load-bearing capacity are critical but poorly understood. This study aimed to determine the mechanical behavior of vertebrae after simulated mild fracture and to identify the determinants of this postfracture behavior. Twenty-one human L3 vertebrae were analyzed for bone mineral density (BMD) by dual-energy X-ray absorptiometry (DXA) and for microarchitecture by micro–computed tomography (µCT). Mechanical testing was performed in two phases: initial compression of vertebra to 25% deformity, followed, after 30 minutes of relaxation, by a similar test to failure to determine postfracture behavior. We assessed (1) initial and postfracture mechanical parameters, (2) changes in mechanical parameters, (3) postfracture elastic behavior by recovery of vertebral height after relaxation, and (4) postfracture plastic behavior by residual strength and stiffness. Postfracture failure load and stiffness were 11% ± 19% and 53% ± 18% lower than initial values (p = .021 and p < .0001, respectively), with 29% to 69% of the variation in the postfracture mechanical behavior explained by the initial values. Both initial and postfracture mechanical behaviors were significantly correlated with bone mass and microarchitecture. Vertebral deformation recovery averaged 31% ± 7% and was associated with trabecular and cortical thickness (r = 0.47 and r = 0.64; p = .03 and p = .002, respectively). Residual strength and stiffness were independent of bone mass and initial mechanical behavior but were related to trabecular and cortical microarchitecture (|r| = 0.50 to 0.58; p = .02 to .006). In summary, we found marked variation in the postfracture load-bearing capacity following simulated mild vertebral fractures. Bone microarchitecture, but not bone mass, was associated with postfracture mechanical behavior of vertebrae. © 2011 American Society for Bone and Mineral Research.
- 6 October 2010
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 26 (4) , 739-746
Open AccessDeterminants of the mechanical behavior of human lumbar vertebrae after simulated mild fracture
The ability of a vertebra to carry load after an initial deformation and the determinants of this postfracture load-bearing capacity are critical but poorly understood. This study aimed to determine the mechanical behavior of vertebrae after simulated mild fracture and to identify the determinants of this postfracture behavior. Twenty-one human L3 vertebrae were analyzed for bone mineral density (BMD) by dual-energy X-ray absorptiometry (DXA) and for microarchitecture by micro–computed tomography (µCT). Mechanical testing was performed in two phases: initial compression of vertebra to 25% deformity, followed, after 30 minutes of relaxation, by a similar test to failure to determine postfracture behavior. We assessed (1) initial and postfracture mechanical parameters, (2) changes in mechanical parameters, (3) postfracture elastic behavior by recovery of vertebral height after relaxation, and (4) postfracture plastic behavior by residual strength and stiffness. Postfracture failure load and stiffness were 11% ± 19% and 53% ± 18% lower than initial values (p = .021 and p < .0001, respectively), with 29% to 69% of the variation in the postfracture mechanical behavior explained by the initial values. Both initial and postfracture mechanical behaviors were significantly correlated with bone mass and microarchitecture. Vertebral deformation recovery averaged 31% ± 7% and was associated with trabecular and cortical thickness (r = 0.47 and r = 0.64; p = .03 and p = .002, respectively). Residual strength and stiffness were independent of bone mass and initial mechanical behavior but were related to trabecular and cortical microarchitecture (|r| = 0.50 to 0.58; p = .02 to .006). In summary, we found marked variation in the postfracture load-bearing capacity following simulated mild vertebral fractures. Bone microarchitecture, but not bone mass, was associated with postfracture mechanical behavior of vertebrae. © 2011 American Society for Bone and Mineral Research.