Michael A. Guttman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael A. Guttman has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Elliot R. McVeigh
Laboratory of Cardiac Energetics, National Institutes of Health, National Heart, Lung and Blood Institute, Bethesda, Maryland
6 shared publications- Robert J. Lederman
National Heart Lung and Blood Institute, Division of Intramural Research, National Institutes of Health, Bethesda, Maryland, USA
5 shared publications Alexander J. Dick
Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD
3 shared publicationsAmish N. Raval
Cardiovascular Branch, National Institutes of Health, National Heart, Lung and Blood Institute, Bethesda, Maryland
2 shared publicationsVenkatesh K. Raman
Cardiovascular Branch, Division of Intramural Research, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, MD
2 shared publications- Andrew E. Arai
Division of Cardiovascular Medicine and Department of Radiology, University of Utah School of Medicine, Salt Lake City, Utah
1 shared publication
Latest Publications
- Open Access
- 29 July 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (2) , 538-542
Real‐time catheter‐directed MRA with effective background suppression and persistent rendering
Purpose: To develop an imaging and visualization technique for real‐time magnetic resonance angiography (rtMRA) fully integrated with a real‐time interactive imaging environment on a clinical MR scanner.Materials and Methods: Intraarterial injections of contrast agent and imaging processing techniques were employed for rapid catheter‐directed assessment of vessel patency and regional tissue perfusion. Operators can image multiple thin slices to maximize anatomic detail or use thick slice or projection imaging to maximize vessel coverage. Techniques in both pulse sequence and image processing were employed to ensure background suppression. Accumulation of maximum pixel values allows persistent display of bolus signal as it passes through the vessels and into tissues. Automatic brightness adjustment was used to ensure visibility at all stages of bolus passage.Results: Experimental intraarterial rtMRA of coronary, renal, and carotid arteries show that vessel trajectories and perfusion territories are well visualized in swine. Switching between standard real‐time imaging and rtMRA imaging after contrast injection was easy to perform during a procedure without stopping the scanner.Conclusion: The proposed technique facilitates visualization of intraarterial contrast injections using real‐time MRI. Although designed for rapid deployment during rtMRI‐guided interventional procedures, the technique may also be useful to supplement the study of vessel anatomy, flow, or perfusion. J. Magn. Reson. Imaging 2008;28:538–542.
- 29 July 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (2) , 538-542
Open AccessReal‐time catheter‐directed MRA with effective background suppression and persistent rendering
Purpose: To develop an imaging and visualization technique for real‐time magnetic resonance angiography (rtMRA) fully integrated with a real‐time interactive imaging environment on a clinical MR scanner.Materials and Methods: Intraarterial injections of contrast agent and imaging processing techniques were employed for rapid catheter‐directed assessment of vessel patency and regional tissue perfusion. Operators can image multiple thin slices to maximize anatomic detail or use thick slice or projection imaging to maximize vessel coverage. Techniques in both pulse sequence and image processing were employed to ensure background suppression. Accumulation of maximum pixel values allows persistent display of bolus signal as it passes through the vessels and into tissues. Automatic brightness adjustment was used to ensure visibility at all stages of bolus passage.Results: Experimental intraarterial rtMRA of coronary, renal, and carotid arteries show that vessel trajectories and perfusion territories are well visualized in swine. Switching between standard real‐time imaging and rtMRA imaging after contrast injection was easy to perform during a procedure without stopping the scanner.Conclusion: The proposed technique facilitates visualization of intraarterial contrast injections using real‐time MRI. Although designed for rapid deployment during rtMRI‐guided interventional procedures, the technique may also be useful to supplement the study of vessel anatomy, flow, or perfusion. J. Magn. Reson. Imaging 2008;28:538–542.
- Open Access
- 29 October 2007
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (6) , 1429-1435
Interventional cardiovascular procedures guided by real‐time MR imaging: An interactive interface using multiple slices, adaptive projection modes and live 3D renderings
Purpose: To develop and test a novel interactive real‐time MRI environment that facilitates image‐guided cardiovascular interventions.Materials and Methods: Color highlighting of device‐mounted receiver coils, accelerated imaging of multiple slices, adaptive projection modes, live three‐dimensional (3D) renderings and other interactive features were utilized to enhance navigation of devices and targeting of tissue.Results: Images are shown from several catheter‐based interventional procedures performed in swine that benefit from this custom interventional MRI interface. These include endograft repair of aortic aneurysm, balloon septostomy of the cardiac interatrial septum, angioplasty and stenting, and endomyocardial cell injection, all using active catheters containing MRI receiver coils.Conclusion: Interactive features not available on standard clinical scanners enhance real‐time MRI for guiding cardiovascular interventional procedures. J. Magn. Reson. Imaging 2007.
- 29 October 2007
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (6) , 1429-1435
Open AccessInterventional cardiovascular procedures guided by real‐time MR imaging: An interactive interface using multiple slices, adaptive projection modes and live 3D renderings
Purpose: To develop and test a novel interactive real‐time MRI environment that facilitates image‐guided cardiovascular interventions.Materials and Methods: Color highlighting of device‐mounted receiver coils, accelerated imaging of multiple slices, adaptive projection modes, live three‐dimensional (3D) renderings and other interactive features were utilized to enhance navigation of devices and targeting of tissue.Results: Images are shown from several catheter‐based interventional procedures performed in swine that benefit from this custom interventional MRI interface. These include endograft repair of aortic aneurysm, balloon septostomy of the cardiac interatrial septum, angioplasty and stenting, and endomyocardial cell injection, all using active catheters containing MRI receiver coils.Conclusion: Interactive features not available on standard clinical scanners enhance real‐time MRI for guiding cardiovascular interventional procedures. J. Magn. Reson. Imaging 2007.
- Open Access
- 23 July 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (2) , 354-361
Imaging of myocardial infarction for diagnosis and intervention using real‐time interactive MRI without ECG‐gating or breath‐holding
Current methods for MRI of infarcted myocardium require ECG‐gating and breath‐holding during contrast‐enhanced segmented k‐space inversion‐recovery (IR) imaging. However, ECG‐gating can be problematic in MRI, and breath‐holding can be difficult for some patients. This work demonstrates that infarcted tissue can be visualized without ECG‐gating or breath‐holding with the use of intermittent inversion pulses during real‐time (RT) interactive imaging with steady‐state free precession (SSFP). The sequence generates a RT image stream containing a myocardium‐nulled image every few frames, which allows nearly simultaneous observation of both infarcted regions and wall motion. First‐pass perfusion and wall motion can be simultaneously observed with minor parameter modifications. This method may reduce diagnostic scan time, expand the target population, improve patient comfort, and facilitate targeted, interventional treatment of infarcted myocardium. Supplementary material for this article can be found on the MRM website at http://www.interscience.wiley.com/jpages/0740‐3194/suppmat/index.html.Magn Reson Med 52:354–361, 2004. Published 2004 Wiley‐Liss, Inc.
- 23 July 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (2) , 354-361
Open AccessImaging of myocardial infarction for diagnosis and intervention using real‐time interactive MRI without ECG‐gating or breath‐holding
Current methods for MRI of infarcted myocardium require ECG‐gating and breath‐holding during contrast‐enhanced segmented k‐space inversion‐recovery (IR) imaging. However, ECG‐gating can be problematic in MRI, and breath‐holding can be difficult for some patients. This work demonstrates that infarcted tissue can be visualized without ECG‐gating or breath‐holding with the use of intermittent inversion pulses during real‐time (RT) interactive imaging with steady‐state free precession (SSFP). The sequence generates a RT image stream containing a myocardium‐nulled image every few frames, which allows nearly simultaneous observation of both infarcted regions and wall motion. First‐pass perfusion and wall motion can be simultaneously observed with minor parameter modifications. This method may reduce diagnostic scan time, expand the target population, improve patient comfort, and facilitate targeted, interventional treatment of infarcted myocardium. Supplementary material for this article can be found on the MRM website at http://www.interscience.wiley.com/jpages/0740‐3194/suppmat/index.html.Magn Reson Med 52:354–361, 2004. Published 2004 Wiley‐Liss, Inc.
- Open Access
- 17 July 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (2) , 315-321
Real‐time accelerated interactive MRI with adaptive TSENSE and UNFOLD
Reduced field‐of‐view (FOV) acceleration using time‐adaptive sensitivity encoding (TSENSE) or unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD) can improve the depiction of motion in real‐time MRI. However, increased computational resources are required to maintain a high frame rate and low latency in image reconstruction and display. A high‐performance software system has been implemented to perform TSENSE and UNFOLD reconstructions for real‐time MRI with interactive, on‐line display. Images were displayed in the scanner room to investigate image‐guided procedures. Examples are shown for normal volunteers and cardiac interventional experiments in animals using a steady‐state free precession (SSFP) sequence. In order to maintain adequate image quality for interventional procedures, the imaging rate was limited to seven frames per second after an acceleration factor of 2 with a voxel size of 1.8 × 3.5 × 8 mm. Initial experiences suggest that TSENSE and UNFOLD can each improve the compromise between spatial and temporal resolution in real‐time imaging, and can function well in interactive imaging. UNFOLD places no additional constraints on receiver coils, and is therefore more flexible than SENSE methods; however, the temporal image filtering can blur motion and reduce the effective acceleration. Methods are proposed to overcome the challenges presented by the use of TSENSE in interactive imaging. TSENSE may be temporarily disabled after changing the imaging plane to avoid transient artifacts as the sensitivity coefficients adapt. For imaging with a combination of surface and interventional coils, a hybrid reconstruction approach is proposed whereby UNFOLD is used for the interventional coils, and TSENSE with or without UNFOLD is used for the surface coils. Magn Reson Med 50:315–321, 2003. Published 2003 Wiley‐Liss, Inc.
- 17 July 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (2) , 315-321
Open AccessReal‐time accelerated interactive MRI with adaptive TSENSE and UNFOLD
Reduced field‐of‐view (FOV) acceleration using time‐adaptive sensitivity encoding (TSENSE) or unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD) can improve the depiction of motion in real‐time MRI. However, increased computational resources are required to maintain a high frame rate and low latency in image reconstruction and display. A high‐performance software system has been implemented to perform TSENSE and UNFOLD reconstructions for real‐time MRI with interactive, on‐line display. Images were displayed in the scanner room to investigate image‐guided procedures. Examples are shown for normal volunteers and cardiac interventional experiments in animals using a steady‐state free precession (SSFP) sequence. In order to maintain adequate image quality for interventional procedures, the imaging rate was limited to seven frames per second after an acceleration factor of 2 with a voxel size of 1.8 × 3.5 × 8 mm. Initial experiences suggest that TSENSE and UNFOLD can each improve the compromise between spatial and temporal resolution in real‐time imaging, and can function well in interactive imaging. UNFOLD places no additional constraints on receiver coils, and is therefore more flexible than SENSE methods; however, the temporal image filtering can blur motion and reduce the effective acceleration. Methods are proposed to overcome the challenges presented by the use of TSENSE in interactive imaging. TSENSE may be temporarily disabled after changing the imaging plane to avoid transient artifacts as the sensitivity coefficients adapt. For imaging with a combination of surface and interventional coils, a hybrid reconstruction approach is proposed whereby UNFOLD is used for the interventional coils, and TSENSE with or without UNFOLD is used for the surface coils. Magn Reson Med 50:315–321, 2003. Published 2003 Wiley‐Liss, Inc.
- 2 December 2002
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 4 (4) , 431-442
Real-Time Volume Rendered MRI for Interventional Guidance
International academic publisher with offices worldwide. Publishing more than 2,100 journals, over 4,000 new books each year, with a books backlist in excess of 60,000 specialist titles. We are one of the world’s leading publishers of scholarly journals, books, eBooks, textbooks and reference works
- 2 December 2002
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 4 (4) , 431-442
Real-Time Volume Rendered MRI for Interventional Guidance
International academic publisher with offices worldwide. Publishing more than 2,100 journals, over 4,000 new books each year, with a books backlist in excess of 60,000 specialist titles. We are one of the world’s leading publishers of scholarly journals, books, eBooks, textbooks and reference works
- Open Access
- 24 July 2001
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (2) , 317-323
Techniques for Fast Stereoscopic MRI
- 24 July 2001
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (2) , 317-323
Open AccessTechniques for Fast Stereoscopic MRI