Debiao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Debiao Li has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
Xiaoming Bi
Siemens Healthcare
10 shared publicationsPeng Lai
Departments of Radiology and Biomedical Engineering, Northwestern University, Chicago, Illinois, USA
7 shared publicationsZhaoyang Fan
Departments of Radiology and Biomedical Engineering, Northwestern University, Chicago, Illinois, USA
6 shared publicationsAndrew C. Larson
Department of Biomedical Engineering, Northwestern University, Chicago, Illinois, USA
5 shared publicationsJaeseok Park
Department of Radiology, Northwestern University, Chicago, Illinois
5 shared publicationsJames C. Carr
Department of Radiology, Northwestern University, Chicago, IL, USA
5 shared publications
Latest Publications
- 22 January 2018
- Published by Wolters Kluwer Health in Stroke
- Vol. 49 (Suppl_1)
Abstract WP134: Quantitatively Monitoring Regression or Progression in Intracranial Atherosclerotic Plaques Using 3D Vessel Wall Imaging and Deep-learning-based Vessel Wall Analysis
Introduction: Intracranial atherosclerotic disease (ICAD) is one of the most common causes of ischemic stroke worldwide. Despite aggressive medical management, the rate of recurrent stroke is 13% at 1 year. Intracranial vessel wall imaging (VWI) is a noninvasive, “looking-beyond-the-lumen” imaging method that can directly characterize the geometric and signal features of ICAD lesions. The present work sought to assess the feasibility of quantitatively monitoring regression or progression of ICAD plaques using VWI-based methods. Methods: Eight ischemic stroke patients (1F, 7M; age 27-66 ys) treated with intensive medical therapy underwent initial (4 days - 4 months of onset) and follow-up 3D VWI (6-13 months). Images were randomized and reviewed by two neuroradiologists to determine the culprit lesion in each subject. A custom-designed deep-learning-based intracranial vessel analysis method was used to segment vessel wall boundaries and quantify the following features of the culprit lesion, including peak normalized wall index (NWI), plaque volume, pre-contrast plaque-wall contrast ratio (CR), and post-contrast plaque enhancement ratio (ER). Results: No subjects except for subject #4 had a recurrent stroke during the follow-up period. The four plaque features exhibited different change patterns as shown in Figure . Subject #1 and #4 demonstrated an increase in plaque ER, volume, and peak NWI; subject #7 demonstrated an increase in plaque CR, volume and peak NWI. Other patients had a decrease or no change in these features. Conclusions: In this work, the interrogated plaque features demonstrated regression in most of patients after intensive medical therapy. Elevated values in some of these features appeared positively associated with stroke recurrence. Temporal changes in these features may have a strong indication on culprit lesions’ response to medical therapy. In conclusion, it is feasible to quantitatively monitor plaque-level treatment response.
- 22 January 2018
- Published by Wolters Kluwer Health in Stroke
- Vol. 49 (Suppl_1)
Abstract WP134: Quantitatively Monitoring Regression or Progression in Intracranial Atherosclerotic Plaques Using 3D Vessel Wall Imaging and Deep-learning-based Vessel Wall Analysis
Introduction: Intracranial atherosclerotic disease (ICAD) is one of the most common causes of ischemic stroke worldwide. Despite aggressive medical management, the rate of recurrent stroke is 13% at 1 year. Intracranial vessel wall imaging (VWI) is a noninvasive, “looking-beyond-the-lumen” imaging method that can directly characterize the geometric and signal features of ICAD lesions. The present work sought to assess the feasibility of quantitatively monitoring regression or progression of ICAD plaques using VWI-based methods. Methods: Eight ischemic stroke patients (1F, 7M; age 27-66 ys) treated with intensive medical therapy underwent initial (4 days - 4 months of onset) and follow-up 3D VWI (6-13 months). Images were randomized and reviewed by two neuroradiologists to determine the culprit lesion in each subject. A custom-designed deep-learning-based intracranial vessel analysis method was used to segment vessel wall boundaries and quantify the following features of the culprit lesion, including peak normalized wall index (NWI), plaque volume, pre-contrast plaque-wall contrast ratio (CR), and post-contrast plaque enhancement ratio (ER). Results: No subjects except for subject #4 had a recurrent stroke during the follow-up period. The four plaque features exhibited different change patterns as shown in Figure . Subject #1 and #4 demonstrated an increase in plaque ER, volume, and peak NWI; subject #7 demonstrated an increase in plaque CR, volume and peak NWI. Other patients had a decrease or no change in these features. Conclusions: In this work, the interrogated plaque features demonstrated regression in most of patients after intensive medical therapy. Elevated values in some of these features appeared positively associated with stroke recurrence. Temporal changes in these features may have a strong indication on culprit lesions’ response to medical therapy. In conclusion, it is feasible to quantitatively monitor plaque-level treatment response.
- 22 January 2018
- Published by Wolters Kluwer Health in Stroke
- Vol. 49 (Suppl_1)
Abstract 54: Combined Vessel Wall and Perforator Imaging for Prediction of Stroke Subtype
Objective: The aim of the present study was to evaluate atherosclerotic plaque characteristics and perforating arteries together by high-resolution magnetic resonance imaging (HRMRI) and to establish their relationship with different infarction patterns. Methods: Stroke patients with artery-to-artery (A-to-A) embolism or branch atheromatous disease (BAD) in middle cerebral artery territory were prospectively enrolled and whole-brain HRMRI was performed. The characteristics of the intracranial atheroma at the maximal stenosis and the numbers of ipsilateral perforating arteries were analyzed. Results: The study involved 59 first-time stroke patients (32 A-to-A embolism and 27 BAD) with 59 culprit plaques. Hyperintensity plaques (HIP) and plaque surface irregularity were more frequently observed in A-to-A embolism group than in the BAD group ( P < 0.001 and P = 0.049, respectively). Patients with A-to-A embolism infarction had more severe stenosis than patients with BAD infarction ( P < 0.001). Logistic regression analysis showed that HIP was an independent predictive factor for A-to-A embolism, with odds ratio of 6.858 (95% confidence interval 1.780 – 26.421; P = 0.005). Moreover, 54 patients (31 A-to-A embolism and 23 BAD) with good-quality images were included in the analysis of perforating arteries. The average number of visualized perforating arteries was significantly lower in patients with BAD compared with A-to-A embolism ( P = 0.022). Interpretation: A-to-A embolism infarction have distinct vascular pathophysiologies in terms of plaque and perforating artery characteristics compared with BAD. Whole brain HRMRI enables the combination of vessel wall and perforating artery imaging which can predict future stroke types.
- 22 January 2018
- Published by Wolters Kluwer Health in Stroke
- Vol. 49 (Suppl_1)
Abstract 54: Combined Vessel Wall and Perforator Imaging for Prediction of Stroke Subtype
Objective: The aim of the present study was to evaluate atherosclerotic plaque characteristics and perforating arteries together by high-resolution magnetic resonance imaging (HRMRI) and to establish their relationship with different infarction patterns. Methods: Stroke patients with artery-to-artery (A-to-A) embolism or branch atheromatous disease (BAD) in middle cerebral artery territory were prospectively enrolled and whole-brain HRMRI was performed. The characteristics of the intracranial atheroma at the maximal stenosis and the numbers of ipsilateral perforating arteries were analyzed. Results: The study involved 59 first-time stroke patients (32 A-to-A embolism and 27 BAD) with 59 culprit plaques. Hyperintensity plaques (HIP) and plaque surface irregularity were more frequently observed in A-to-A embolism group than in the BAD group ( P < 0.001 and P = 0.049, respectively). Patients with A-to-A embolism infarction had more severe stenosis than patients with BAD infarction ( P < 0.001). Logistic regression analysis showed that HIP was an independent predictive factor for A-to-A embolism, with odds ratio of 6.858 (95% confidence interval 1.780 – 26.421; P = 0.005). Moreover, 54 patients (31 A-to-A embolism and 23 BAD) with good-quality images were included in the analysis of perforating arteries. The average number of visualized perforating arteries was significantly lower in patients with BAD compared with A-to-A embolism ( P = 0.022). Interpretation: A-to-A embolism infarction have distinct vascular pathophysiologies in terms of plaque and perforating artery characteristics compared with BAD. Whole brain HRMRI enables the combination of vessel wall and perforating artery imaging which can predict future stroke types.
- 2 April 2011
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 28 (3) , 567-575
Coronary wall MR Imaging in patients with rapid heart rates: a feasibility study of black-blood steady-state free precession (SSFP)
We assessed the hypothesis that black-blood steady-state free precession (SSFP) would provide coronary wall images comparable to images from TSE and have better performance than TSE under conditions of fast heart rate. With IRB approval, thirty participants without a history of coronary artery disease (19 men, 11 women, 26–83 y/o) were scanned with a 1.5 T MR scanner. Cross-sectional black-blood images of the proximal portions of coronary arteries were acquired with a two-dimensional (2D), double inversion recovery (DIR) prepared TSE sequence and a 2D DIR SSFP sequence on the same planes. Image quality (ranked with a 4-point system, scored from 0 to 3), vessel wall area and thickness, signal-to-noise ratio (SNR) of the wall and contrast-to-noise ratio (CNR, wall to lumen) were compared between SSFP and TSE with SPSS software (v 13.0). Totally 28 scans were completed. For SSFP and TSE, there was no difference in image quality. SSFP had a higher SNR (23.7 ± 10.1 vs. 14.4 ± 5.2, P < 0.001) and wall–lumen CNR (8.8 ± 4.5 vs. 6.7 ± 3.2, P = 0.001). Good agreements between measured wall area (r = 0.701, P < 0.001) and thickness (r = 0.560, P < 0.001) were found. For 10 participants with heart rate more than 80 beats/min, the image quality of SSFP was higher than TSE (P = 0.016). SSFP provided image quality and measurement accuracy that was comparable to TSE. With its higher performance under fast heart rate conditions, SSFP may break through the existing thresholds for heart rate and extend clinical applicability of coronary wall MR imaging to a larger population.
- 2 April 2011
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 28 (3) , 567-575
Coronary wall MR Imaging in patients with rapid heart rates: a feasibility study of black-blood steady-state free precession (SSFP)
We assessed the hypothesis that black-blood steady-state free precession (SSFP) would provide coronary wall images comparable to images from TSE and have better performance than TSE under conditions of fast heart rate. With IRB approval, thirty participants without a history of coronary artery disease (19 men, 11 women, 26–83 y/o) were scanned with a 1.5 T MR scanner. Cross-sectional black-blood images of the proximal portions of coronary arteries were acquired with a two-dimensional (2D), double inversion recovery (DIR) prepared TSE sequence and a 2D DIR SSFP sequence on the same planes. Image quality (ranked with a 4-point system, scored from 0 to 3), vessel wall area and thickness, signal-to-noise ratio (SNR) of the wall and contrast-to-noise ratio (CNR, wall to lumen) were compared between SSFP and TSE with SPSS software (v 13.0). Totally 28 scans were completed. For SSFP and TSE, there was no difference in image quality. SSFP had a higher SNR (23.7 ± 10.1 vs. 14.4 ± 5.2, P < 0.001) and wall–lumen CNR (8.8 ± 4.5 vs. 6.7 ± 3.2, P = 0.001). Good agreements between measured wall area (r = 0.701, P < 0.001) and thickness (r = 0.560, P < 0.001) were found. For 10 participants with heart rate more than 80 beats/min, the image quality of SSFP was higher than TSE (P = 0.016). SSFP provided image quality and measurement accuracy that was comparable to TSE. With its higher performance under fast heart rate conditions, SSFP may break through the existing thresholds for heart rate and extend clinical applicability of coronary wall MR imaging to a larger population.
- Open Access
- 1 October 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (1) , 37
The association of lesion eccentricity with plaque morphology and components in the superficial femoral artery: a high-spatial-resolution, multi-contrast weighted CMR study
- 1 October 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (1) , 37
Open AccessThe association of lesion eccentricity with plaque morphology and components in the superficial femoral artery: a high-spatial-resolution, multi-contrast weighted CMR study
- 1 September 2010
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 34 (5) , 684-688
Myocardial Perfusion Magnetic Resonance Imaging Using Sliding-Window Conjugate-Gradient HYPR Methods in Canine With Stenotic Coronary Arteries
First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.
- 1 September 2010
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 34 (5) , 684-688
Myocardial Perfusion Magnetic Resonance Imaging Using Sliding-Window Conjugate-Gradient HYPR Methods in Canine With Stenotic Coronary Arteries
First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.
- 1 August 2010
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 45 (8) , 458-464
Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T Using Interleaved Echo Planar Imaging
The goal of this work was to reduce the scan time of contrast-enhanced whole-heart coronary magnetic resonance angiography (MRA) by using a gradient echo interleaved echo planar imaging (GRE-EPI) sequence at 3 T field strength. A GRE-EPI sequence was optimized to acquire contrast-enhanced whole-heart coronary MRA at 3 T. First-order phase correction was used for alignment of the odd and even echoes in the GRE-EPI echo train. Single and dual reference scan techniques for estimation of the linear phase correction parameters were evaluated using both phantom and volunteer studies. The GRE-EPI readout was combined with parallel imaging for a further reduction in scan time. To avoid image distortions, calibration signals for coil sensitivity estimation were acquired in a separate low resolution GRE scan before the whole-heart GRE-EPI scan. Eight healthy volunteers were scanned with the optimized contrast-enhanced GRE-EPI sequence. GRE-EPI images were acquired during slow infusion (0.3 mL/s) of 0.1 mmol/kg body weight of Gd-BOPTA. For comparison purposes, the same 8 volunteers were scanned again in a separate scan session using a traditional GRE sequence with double the dose (0.2 mmol/kg body weight) of the same contrast agent with the same injection rate. The contrast-enhanced GRE-EPI and contrast-enhanced GRE techniques were compared in terms of relative signal-to-noise ratio (rSNR), relative contrast-to-noise ratio (rCNR), image quality scores, and visualized vessel lengths. Both, phantom and volunteer studies demonstrated that the dual reference scan phase correction technique was a key step for obtaining satisfactory image quality using GRE-EPI at 3 T. Whole-heart coronary MRA with a spatial resolution of 1.0 × 1.0 × 2.0 mm3 was acquired with the GRE-EPI sequence in an average scan time of 2.5 ± 0.6 minutes, compared with 8.6 ± 2.7 minutes for the GRE technique. The GRE-EPI technique had lower rCNR compared with the GRE sequence. The image quality and coronary artery visualization with the GRE-EPI technique were adequate, and there was no statistically significant difference in the image quality scores, rSNR, and visualized coronary artery lengths between the GRE-EPI and GRE techniques. Contrast-enhanced whole-heart coronary MRA using the GRE-EPI technique resulted in excellent delineation of all the major coronary arteries and compared with current GRE techniques demonstrated a factor of 2 reduction in contrast agent dose and a factor of 3 reduction in scan time.
- 1 August 2010
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 45 (8) , 458-464
Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T Using Interleaved Echo Planar Imaging
The goal of this work was to reduce the scan time of contrast-enhanced whole-heart coronary magnetic resonance angiography (MRA) by using a gradient echo interleaved echo planar imaging (GRE-EPI) sequence at 3 T field strength. A GRE-EPI sequence was optimized to acquire contrast-enhanced whole-heart coronary MRA at 3 T. First-order phase correction was used for alignment of the odd and even echoes in the GRE-EPI echo train. Single and dual reference scan techniques for estimation of the linear phase correction parameters were evaluated using both phantom and volunteer studies. The GRE-EPI readout was combined with parallel imaging for a further reduction in scan time. To avoid image distortions, calibration signals for coil sensitivity estimation were acquired in a separate low resolution GRE scan before the whole-heart GRE-EPI scan. Eight healthy volunteers were scanned with the optimized contrast-enhanced GRE-EPI sequence. GRE-EPI images were acquired during slow infusion (0.3 mL/s) of 0.1 mmol/kg body weight of Gd-BOPTA. For comparison purposes, the same 8 volunteers were scanned again in a separate scan session using a traditional GRE sequence with double the dose (0.2 mmol/kg body weight) of the same contrast agent with the same injection rate. The contrast-enhanced GRE-EPI and contrast-enhanced GRE techniques were compared in terms of relative signal-to-noise ratio (rSNR), relative contrast-to-noise ratio (rCNR), image quality scores, and visualized vessel lengths. Both, phantom and volunteer studies demonstrated that the dual reference scan phase correction technique was a key step for obtaining satisfactory image quality using GRE-EPI at 3 T. Whole-heart coronary MRA with a spatial resolution of 1.0 × 1.0 × 2.0 mm3 was acquired with the GRE-EPI sequence in an average scan time of 2.5 ± 0.6 minutes, compared with 8.6 ± 2.7 minutes for the GRE technique. The GRE-EPI technique had lower rCNR compared with the GRE sequence. The image quality and coronary artery visualization with the GRE-EPI technique were adequate, and there was no statistically significant difference in the image quality scores, rSNR, and visualized coronary artery lengths between the GRE-EPI and GRE techniques. Contrast-enhanced whole-heart coronary MRA using the GRE-EPI technique resulted in excellent delineation of all the major coronary arteries and compared with current GRE techniques demonstrated a factor of 2 reduction in contrast agent dose and a factor of 3 reduction in scan time.
- Open Access
- 22 July 2010
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 32 (2) , 399-408
3D flow‐independent peripheral vessel wall imaging using T2‐prepared phase‐sensitive inversion‐recovery steady‐state free precession
Purpose: To develop a 3D flow‐independent peripheral vessel wall imaging method using T2‐prepared phase‐sensitive inversion‐recovery (T2PSIR) steady‐state free precession (SSFP).Materials and Methods: A 3D T2‐prepared and nonselective inversion‐recovery SSFP sequence was designed to achieve flow‐independent blood suppression for vessel wall imaging based on T1 and T2 properties of the vessel wall and blood. To maximize image contrast and reduce its dependence on the inversion time (TI), phase‐sensitive reconstruction was used to restore the true signal difference between vessel wall and blood. The feasibility of this technique for peripheral artery wall imaging was tested in 13 healthy subjects. Image signal‐to‐noise ratio (SNR), wall/lumen contrast‐to‐noise ratio (CNR), and scan efficiency were compared between this technique and conventional 2D double inversion recovery – turbo spin echo (DIR‐TSE) in eight subjects.Results: 3D T2PSIR SSFP provided more efficient data acquisition (32 slices and 64 mm in 4 minutes, 7.5 seconds per slice) than 2D DIR‐TSE (2–3 minutes per slice). SNR of the vessel wall and CNR between vessel wall and lumen were significantly increased as compared to those of DIR‐TSE (P < 0.001). Vessel wall and lumen areas of the two techniques are strongly correlated (intraclass correlation coefficients: 0.975 and 0.937, respectively; P < 0.001 for both). The lumen area of T2PSIR SSFP is slightly larger than that of DIR‐TSE (P = 0.008). The difference in vessel wall area between the two techniques is not statistically significant.Conclusion: T2PSIR SSFP is a promising technique for peripheral vessel wall imaging. It provides excellent blood signal suppression and vessel wall/lumen contrast. It can cover a 3D volume efficiently and is flow‐ and TI‐independent. J. Magn. Reson. Imaging 2010;32:399–408.
- 22 July 2010
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 32 (2) , 399-408
Open Access3D flow‐independent peripheral vessel wall imaging using T2‐prepared phase‐sensitive inversion‐recovery steady‐state free precession
Purpose: To develop a 3D flow‐independent peripheral vessel wall imaging method using T2‐prepared phase‐sensitive inversion‐recovery (T2PSIR) steady‐state free precession (SSFP).Materials and Methods: A 3D T2‐prepared and nonselective inversion‐recovery SSFP sequence was designed to achieve flow‐independent blood suppression for vessel wall imaging based on T1 and T2 properties of the vessel wall and blood. To maximize image contrast and reduce its dependence on the inversion time (TI), phase‐sensitive reconstruction was used to restore the true signal difference between vessel wall and blood. The feasibility of this technique for peripheral artery wall imaging was tested in 13 healthy subjects. Image signal‐to‐noise ratio (SNR), wall/lumen contrast‐to‐noise ratio (CNR), and scan efficiency were compared between this technique and conventional 2D double inversion recovery – turbo spin echo (DIR‐TSE) in eight subjects.Results: 3D T2PSIR SSFP provided more efficient data acquisition (32 slices and 64 mm in 4 minutes, 7.5 seconds per slice) than 2D DIR‐TSE (2–3 minutes per slice). SNR of the vessel wall and CNR between vessel wall and lumen were significantly increased as compared to those of DIR‐TSE (P < 0.001). Vessel wall and lumen areas of the two techniques are strongly correlated (intraclass correlation coefficients: 0.975 and 0.937, respectively; P < 0.001 for both). The lumen area of T2PSIR SSFP is slightly larger than that of DIR‐TSE (P = 0.008). The difference in vessel wall area between the two techniques is not statistically significant.Conclusion: T2PSIR SSFP is a promising technique for peripheral vessel wall imaging. It provides excellent blood signal suppression and vessel wall/lumen contrast. It can cover a 3D volume efficiently and is flow‐ and TI‐independent. J. Magn. Reson. Imaging 2010;32:399–408.
- Open Access
- 17 June 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 64 (4) , 1148-1154
Free‐breathing myocardial perfusion MRI using SW‐CG‐HYPR and motion correction
First‐pass perfusion MRI is a promising technique to detect ischemic heart disease. Sliding window (SW) conjugate‐gradient (CG) highly constrained back‐projection reconstruction (HYPR) (SW‐CG‐HYPR) has been proposed to increase spatial coverage, spatial resolution, and SNR. However, this method is sensitive to respiratory motion and thus requires breath‐hold. This work presents a non‐model‐based motion correction method combined with SW‐CG‐HYPR to perform free‐breathing myocardial MR imaging. Simulation studies were first performed to show the effectiveness of the proposed motion correction method and its independence from the pattern of the respiratory motion. After that, in vivo studies were performed in six healthy volunteers. From all of the volunteer studies, the image quality score of free breathing perfusion images with motion correction (3.11 ± 0.34) is improved compared with that of images without motion correction (2.27 ± 0.32), and is comparable with that of successful breath‐hold images (3.12 ± 0.38). This result was further validated by a quantitative sharpness analysis. The left ventricle and myocardium signal changes in motion corrected free‐breathing perfusion images were closely correlated to those observed in breath‐hold images. The correlation coefficient is 0.9764 for myocardial signals. Bland–Altman analysis confirmed the agreement between the free‐breathing SW‐CG‐HYPR method with motion correction and the breath‐hold SW‐CG‐HYPR. This technique may allow myocardial perfusion MRI during free breathing. Magn Reson Med, 2010.
- 17 June 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 64 (4) , 1148-1154
Open AccessFree‐breathing myocardial perfusion MRI using SW‐CG‐HYPR and motion correction
First‐pass perfusion MRI is a promising technique to detect ischemic heart disease. Sliding window (SW) conjugate‐gradient (CG) highly constrained back‐projection reconstruction (HYPR) (SW‐CG‐HYPR) has been proposed to increase spatial coverage, spatial resolution, and SNR. However, this method is sensitive to respiratory motion and thus requires breath‐hold. This work presents a non‐model‐based motion correction method combined with SW‐CG‐HYPR to perform free‐breathing myocardial MR imaging. Simulation studies were first performed to show the effectiveness of the proposed motion correction method and its independence from the pattern of the respiratory motion. After that, in vivo studies were performed in six healthy volunteers. From all of the volunteer studies, the image quality score of free breathing perfusion images with motion correction (3.11 ± 0.34) is improved compared with that of images without motion correction (2.27 ± 0.32), and is comparable with that of successful breath‐hold images (3.12 ± 0.38). This result was further validated by a quantitative sharpness analysis. The left ventricle and myocardium signal changes in motion corrected free‐breathing perfusion images were closely correlated to those observed in breath‐hold images. The correlation coefficient is 0.9764 for myocardial signals. Bland–Altman analysis confirmed the agreement between the free‐breathing SW‐CG‐HYPR method with motion correction and the breath‐hold SW‐CG‐HYPR. This technique may allow myocardial perfusion MRI during free breathing. Magn Reson Med, 2010.