Jared Guthrie Cobb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jared Guthrie Cobb has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Jingping Xie
Vanderbilt University Institute of Imaging Science
4 shared publicationsJohn C. Gore
Vanderbilt University Department of Biomedical Engineering
4 shared publicationsDaniel F. Gochberg
Vanderbilt University Institute of Imaging Science
2 shared publicationsKe Li
Vanderbilt University Institute of Imaging Science
2 shared publicationsCynthia B. Paschal
Vanderbilt University Department of Biomedical Engineering and Vanderbilt University Institute of Imaging Science, Nashville, Tennessee
1 shared publicationJ. Herman Kan
Texas Children’s Hospital Department of Radiology, Houston, Texas, USA
1 shared publication
Latest Publications
- 1 January 2014
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 32 (1) , 28-40
Exchange-mediated contrast in CEST and spin-lock imaging
- 1 January 2014
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 32 (1) , 28-40
Exchange-mediated contrast in CEST and spin-lock imaging
- Open Access
- 6 May 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (2) , 299-305
T1ρ mapping of pediatric epiphyseal and articular cartilage in the knee
Purpose: To evaluate the feasibility of measuring T1ρ values in epiphyseal cartilage in children, we have conducted a novel study of spin locking techniques. Adult articular cartilage has been widely studied with spin locking techniques by magnetic resonance imaging. However, no results are available for in vivo T1ρ imaging of developing cartilage.Materials and Methods: Ten volunteers of age 6 ± 3 years were recruited to have T1ρ mapping performed on the knee at the conclusion of their clinical study. T1ρ maps were generated using a spin‐lock cluster followed by a fast spin‐echo imaging sequence. Regions of interest (ROIs) were placed in non–load‐bearing (NLB), load‐bearing (LB), and articular cartilage.Results: Student's t‐tests were performed to compare means among the ROIs. Mean T1ρ for epiphyseal and articular cartilage was 49.8 ± 9 and 76.6 ± 7 ms, respectively. LB and NLB T1ρ vales were 47.1 ± 9.5 and 52.5 ± 9 ms, respectively. Significant differences were found in T1ρ values between epiphyseal and articular cartilage layers (P = 0.0001). No difference in T1ρ was observed between NLB and LB layers. A modest trend was also noted for epiphyseal and articular cartilage regions with age.Conclusion: It is feasible to quantify differences in epiphyseal and articular cartilage layers with SL techniques. T1ρ holds promise as a noninvasive method of studying normal and abnormal developmental states of cartilage in children. J. Magn. Reson. Imaging 2013;38:299–305.
- 6 May 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (2) , 299-305
Open AccessT1ρ mapping of pediatric epiphyseal and articular cartilage in the knee
Purpose: To evaluate the feasibility of measuring T1ρ values in epiphyseal cartilage in children, we have conducted a novel study of spin locking techniques. Adult articular cartilage has been widely studied with spin locking techniques by magnetic resonance imaging. However, no results are available for in vivo T1ρ imaging of developing cartilage.Materials and Methods: Ten volunteers of age 6 ± 3 years were recruited to have T1ρ mapping performed on the knee at the conclusion of their clinical study. T1ρ maps were generated using a spin‐lock cluster followed by a fast spin‐echo imaging sequence. Regions of interest (ROIs) were placed in non–load‐bearing (NLB), load‐bearing (LB), and articular cartilage.Results: Student's t‐tests were performed to compare means among the ROIs. Mean T1ρ for epiphyseal and articular cartilage was 49.8 ± 9 and 76.6 ± 7 ms, respectively. LB and NLB T1ρ vales were 47.1 ± 9.5 and 52.5 ± 9 ms, respectively. Significant differences were found in T1ρ values between epiphyseal and articular cartilage layers (P = 0.0001). No difference in T1ρ was observed between NLB and LB layers. A modest trend was also noted for epiphyseal and articular cartilage regions with age.Conclusion: It is feasible to quantify differences in epiphyseal and articular cartilage layers with SL techniques. T1ρ holds promise as a noninvasive method of studying normal and abnormal developmental states of cartilage in children. J. Magn. Reson. Imaging 2013;38:299–305.
- Open Access
- 12 July 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (5) , 1357-1366
Contributions of chemical and diffusive exchange to T1ρ dispersion
Variations in local magnetic susceptibility may induce magnetic field gradients that affect the signals acquired for MR imaging. Under appropriate diffusion conditions, such fields produce effects similar to slow chemical exchange. These effects may also be found in combination with other chemical exchange processes at multiple time scales. We investigate these effects with simulations and measurements to determine their contributions to rotating frame (R1ρ) relaxation in model systems. Simulations of diffusive and chemical exchange effects on R1ρ dispersion were performed using the Bloch equations. Additionally, R1ρ dispersion was measured in suspensions of Sephadex and latex beads with varying spin locking fields at 9.4 T. A novel analysis method was used to iteratively fit for apparent chemical and diffusive exchange rates with a model by Chopra et al. Single‐ and double‐inflection points in R1ρ dispersion profiles were observed, respectively, in simulations of slow diffusive exchange alone and when combined with rapid chemical exchange. These simulations were consistent with measurements of R1ρ in latex bead suspensions and small‐diameter Sephadex beads that showed single‐ and double‐inflection points, respectively. These observations, along with measurements following changes in temperature and pH, are consistent with the combined effects of slow diffusion and rapid −OH exchange processes. Magn Reson Med, 2013.
- 12 July 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 69 (5) , 1357-1366
Open AccessContributions of chemical and diffusive exchange to T1ρ dispersion
Variations in local magnetic susceptibility may induce magnetic field gradients that affect the signals acquired for MR imaging. Under appropriate diffusion conditions, such fields produce effects similar to slow chemical exchange. These effects may also be found in combination with other chemical exchange processes at multiple time scales. We investigate these effects with simulations and measurements to determine their contributions to rotating frame (R1ρ) relaxation in model systems. Simulations of diffusive and chemical exchange effects on R1ρ dispersion were performed using the Bloch equations. Additionally, R1ρ dispersion was measured in suspensions of Sephadex and latex beads with varying spin locking fields at 9.4 T. A novel analysis method was used to iteratively fit for apparent chemical and diffusive exchange rates with a model by Chopra et al. Single‐ and double‐inflection points in R1ρ dispersion profiles were observed, respectively, in simulations of slow diffusive exchange alone and when combined with rapid chemical exchange. These simulations were consistent with measurements of R1ρ in latex bead suspensions and small‐diameter Sephadex beads that showed single‐ and double‐inflection points, respectively. These observations, along with measurements following changes in temperature and pH, are consistent with the combined effects of slow diffusion and rapid −OH exchange processes. Magn Reson Med, 2013.
- Open Access
- 27 September 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (5) , 1427-1433
Exchange‐mediated contrast agents for spin‐lock imaging
Measurements of relaxation rates in the rotating frame with spin‐locking techniques are sensitive to substances with exchanging protons with appropriate chemical shifts. The authors develop a novel approach to exchange‐rate selective imaging based on measured T1ρ dispersion with applied locking field strength, and demonstrate the method on samples containing the X‐ray contrast agent Iohexol with and without cross‐linked bovine serum albumin. T1ρ dispersion of water in the phantoms was measured with a Varian 9.4‐T magnet by an on‐resonance spin‐locking pulse with fast spin‐echo readout, and the results used to estimate exchange rates. The Iohexol phantom alone gave a fitted exchange rate of ∼1 kHz, bovine serum albumin alone was ∼11 kHz, and in combination gave rates in between. By using these estimated rates, we demonstrate how a novel spin‐locking imaging method may be used to enhance contrast due to the presence of a contrast agent whose protons have specific exchange rates. Magn Reson Med, 2012.
- 27 September 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (5) , 1427-1433
Open AccessExchange‐mediated contrast agents for spin‐lock imaging
Measurements of relaxation rates in the rotating frame with spin‐locking techniques are sensitive to substances with exchanging protons with appropriate chemical shifts. The authors develop a novel approach to exchange‐rate selective imaging based on measured T1ρ dispersion with applied locking field strength, and demonstrate the method on samples containing the X‐ray contrast agent Iohexol with and without cross‐linked bovine serum albumin. T1ρ dispersion of water in the phantoms was measured with a Varian 9.4‐T magnet by an on‐resonance spin‐locking pulse with fast spin‐echo readout, and the results used to estimate exchange rates. The Iohexol phantom alone gave a fitted exchange rate of ∼1 kHz, bovine serum albumin alone was ∼11 kHz, and in combination gave rates in between. By using these estimated rates, we demonstrate how a novel spin‐locking imaging method may be used to enhance contrast due to the presence of a contrast agent whose protons have specific exchange rates. Magn Reson Med, 2012.
- Open Access
- 16 May 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (6) , 1563-1571
Contributions of chemical exchange to T1ρ dispersion in a tissue model
Variations in T1ρ with locking‐field strength (T1ρ dispersion) may be used to estimate proton exchange rates. We developed a novel approach utilizing the second derivative of the dispersion curve to measure exchange in a model system of cross‐linked polyacrylamide gels. These gels were varied in relative composition of comonomers, increasing stiffness, and in pH, modifying exchange rates. Magnetic resonance images were recorded with a spin‐locking sequence as described by Sepponen et al. These measurements were fit to a mono‐exponential decay function yielding values for T1ρ at each locking‐field measured. These values were then fit to a model by Chopra et al. for estimating exchange rates. For low stiffness gels, the calculated exchange values increased by a factor of 4 as pH increased, consistent with chemical exchange being the dominant contributor to T1ρ dispersion. Interestingly, calculated chemical exchange rates also increased with stiffness, likely due to modified side‐chain exchange kinetics as the composition varied. This article demonstrates a new method to assess the structural and chemical effects on T1ρ relaxation dispersion with a suitable model. These phenomena may be exploited in an imaging context to emphasize the presence of nuclei of specific exchange rates, rather than chemical shifts. Magn Reson Med, 2011.
- 16 May 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (6) , 1563-1571
Open AccessContributions of chemical exchange to T1ρ dispersion in a tissue model
Variations in T1ρ with locking‐field strength (T1ρ dispersion) may be used to estimate proton exchange rates. We developed a novel approach utilizing the second derivative of the dispersion curve to measure exchange in a model system of cross‐linked polyacrylamide gels. These gels were varied in relative composition of comonomers, increasing stiffness, and in pH, modifying exchange rates. Magnetic resonance images were recorded with a spin‐locking sequence as described by Sepponen et al. These measurements were fit to a mono‐exponential decay function yielding values for T1ρ at each locking‐field measured. These values were then fit to a model by Chopra et al. for estimating exchange rates. For low stiffness gels, the calculated exchange values increased by a factor of 4 as pH increased, consistent with chemical exchange being the dominant contributor to T1ρ dispersion. Interestingly, calculated chemical exchange rates also increased with stiffness, likely due to modified side‐chain exchange kinetics as the composition varied. This article demonstrates a new method to assess the structural and chemical effects on T1ρ relaxation dispersion with a suitable model. These phenomena may be exploited in an imaging context to emphasize the presence of nuclei of specific exchange rates, rather than chemical shifts. Magn Reson Med, 2011.
- Open Access
- 26 August 2009
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (3) , 684-689
Improved in vivo measurement of myocardial transverse relaxation with 3 Tesla magnetic resonance imaging
Purpose: To develop practical methods at 3 Tesla (T) for measuring myocardial transverse relaxation in normal human myocardium.Materials and Methods: Ten healthy volunteers were investigated with four multi‐echo, turbo spin‐echo (TSE) methods. Each method traded acquired phase encoding lines per image for echo‐image sample points obtained along the T2 decay curve. Four multi‐echo turbo field‐echo (TFE) methods were also tested. The TFE methods highlighted differences between achievable receiver bandwidth and echo time constraints versus the number of sample points obtained along the T decay curve.Results: Measured transverse relaxation values were consistent in reported means across all scan methods. T2 for the ventricular septum was measured as 58.8 ± 7.7 ms (N = 10). T for the ventricular septum was 31.6 ± 5.8 ms (N = 10). The variation of mean T2 or T within an region of interest improved significantly with increases in acquired echoes. Therefore, four or more echoes may provide for clear distinctions between regions of altered tissue composition within a subject.Conclusion: These results suggest that the 4‐echo methods are best suited for measuring variations in transverse relaxation values in the mid‐ventricular septum. J. Magn. Reson. Imaging 2009;30:684–689.
- 26 August 2009
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (3) , 684-689
Open AccessImproved in vivo measurement of myocardial transverse relaxation with 3 Tesla magnetic resonance imaging
Purpose: To develop practical methods at 3 Tesla (T) for measuring myocardial transverse relaxation in normal human myocardium.Materials and Methods: Ten healthy volunteers were investigated with four multi‐echo, turbo spin‐echo (TSE) methods. Each method traded acquired phase encoding lines per image for echo‐image sample points obtained along the T2 decay curve. Four multi‐echo turbo field‐echo (TFE) methods were also tested. The TFE methods highlighted differences between achievable receiver bandwidth and echo time constraints versus the number of sample points obtained along the T decay curve.Results: Measured transverse relaxation values were consistent in reported means across all scan methods. T2 for the ventricular septum was measured as 58.8 ± 7.7 ms (N = 10). T for the ventricular septum was 31.6 ± 5.8 ms (N = 10). The variation of mean T2 or T within an region of interest improved significantly with increases in acquired echoes. Therefore, four or more echoes may provide for clear distinctions between regions of altered tissue composition within a subject.Conclusion: These results suggest that the 4‐echo methods are best suited for measuring variations in transverse relaxation values in the mid‐ventricular septum. J. Magn. Reson. Imaging 2009;30:684–689.