Jing Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jing Yuan has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Lawrence P. Panych
Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
5 shared publicationsBruno Madore
Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
4 shared publications- Yi Xiang Jshiang Wáng
Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
4 shared publications - Ann Dorothy King
Department of Imaging and Interventional Radiology Faculty of Medicine, The Chinese University of Hong Kong, Prince of Wales Hospital Hong Kong China
3 shared publications - Anil Tejbhan Ahuja
Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong
2 shared publications Feng Zhao
The Chinese University of Hong Kong
2 shared publications
Latest Publications
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2013 (1094687X) , 5139-5142
Accuracy and uncertainty of asymmetric magnetization transfer ratio quantification for amide proton transfer (APT) imaging at 3T: A Monte Carlo study
Amide proton transfer (APT) imaging offers a novel and powerful MRI contrast mechanism for quantitative molecular imaging based on the principle of chemical exchange saturation transfer (CEST). Asymmetric magnetization transfer ratio (MTR asym ) quantification is crucial for Z-spectrum analysis of APT imaging, but is still challenging, particularly at clinical field strength. This paper studies the accuracy and uncertainty in the quantification of MTR asym for APT imaging at 3T, by using high-order polynomial fitting of Z-spectrum through Monte Carlo simulation. Results show that polynomial fitting is a biased estimator that consistently underestimates MTR asym . For a fixed polynomial order, the accuracy of MTR asym is almost constant with regard to signal-to-noise ratio (SNR) while the uncertainty decreases exponentially with SNR. The higher order polynomial fitting increases both the accuracy and the uncertainty of MTR asym . For different APT signal intensity levels, the relative accuracy and the absolute uncertainty keep constant for a fixed polynomial order. These results indicate the limitations and pitfalls of polynomial fitting for MTR asym quantification so better quantification technique for MTR asym estimation is warranted.
- 1 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2013 (1094687X) , 5139-5142
Accuracy and uncertainty of asymmetric magnetization transfer ratio quantification for amide proton transfer (APT) imaging at 3T: A Monte Carlo study
Amide proton transfer (APT) imaging offers a novel and powerful MRI contrast mechanism for quantitative molecular imaging based on the principle of chemical exchange saturation transfer (CEST). Asymmetric magnetization transfer ratio (MTR asym ) quantification is crucial for Z-spectrum analysis of APT imaging, but is still challenging, particularly at clinical field strength. This paper studies the accuracy and uncertainty in the quantification of MTR asym for APT imaging at 3T, by using high-order polynomial fitting of Z-spectrum through Monte Carlo simulation. Results show that polynomial fitting is a biased estimator that consistently underestimates MTR asym . For a fixed polynomial order, the accuracy of MTR asym is almost constant with regard to signal-to-noise ratio (SNR) while the uncertainty decreases exponentially with SNR. The higher order polynomial fitting increases both the accuracy and the uncertainty of MTR asym . For different APT signal intensity levels, the relative accuracy and the absolute uncertainty keep constant for a fixed polynomial order. These results indicate the limitations and pitfalls of polynomial fitting for MTR asym quantification so better quantification technique for MTR asym estimation is warranted.
- Open Access
- 1 December 2012
- Vol. 2 (4) , 245-253
Quantitative evaluation of dual-flip-angle T1 mapping on DCE-MRI kinetic parameter estimation in head and neck
To quantitatively evaluate the kinetic parameter estimation for head and neck (HN) dynamic contrast-enhanced (DCE) MRI with dual-flip-angle (DFA) T1 mapping. Clinical DCE-MRI datasets of 23 patients with HN tumors were included in this study. T1 maps were generated based on multiple-flip-angle (MFA) method and different DFA combinations. Tofts model parameter maps of kep, Ktrans and vp based on MFA and DFAs were calculated and compared. Fitted parameter by MFA and DFAs were quantitatively evaluated in primary tumor, salivary gland and muscle. T1 mapping deviations by DFAs produced remarkable kinetic parameter estimation deviations in head and neck tissues. In particular, the DFA of [2º, 7º] overestimated, while [7º, 12º] and [7º, 15º] underestimated Ktrans and vp, significantly (P<0.01). [2º, 15º] achieved the smallest but still statistically significant overestimation for Ktrans and vp in primary tumors, 32.1% and 16.2% respectively. kep fitting results by DFAs were relatively close to the MFA reference compared to Ktrans and vp. T1 deviations induced by DFA could result in significant errors in kinetic parameter estimation, particularly Ktrans and vp, through Tofts model fitting. MFA method should be more reliable and robust for accurate quantitative pharmacokinetic analysis in head and neck.
- 1 December 2012
- Vol. 2 (4) , 245-253
Open AccessQuantitative evaluation of dual-flip-angle T1 mapping on DCE-MRI kinetic parameter estimation in head and neck
To quantitatively evaluate the kinetic parameter estimation for head and neck (HN) dynamic contrast-enhanced (DCE) MRI with dual-flip-angle (DFA) T1 mapping. Clinical DCE-MRI datasets of 23 patients with HN tumors were included in this study. T1 maps were generated based on multiple-flip-angle (MFA) method and different DFA combinations. Tofts model parameter maps of kep, Ktrans and vp based on MFA and DFAs were calculated and compared. Fitted parameter by MFA and DFAs were quantitatively evaluated in primary tumor, salivary gland and muscle. T1 mapping deviations by DFAs produced remarkable kinetic parameter estimation deviations in head and neck tissues. In particular, the DFA of [2º, 7º] overestimated, while [7º, 12º] and [7º, 15º] underestimated Ktrans and vp, significantly (P<0.01). [2º, 15º] achieved the smallest but still statistically significant overestimation for Ktrans and vp in primary tumors, 32.1% and 16.2% respectively. kep fitting results by DFAs were relatively close to the MFA reference compared to Ktrans and vp. T1 deviations induced by DFA could result in significant errors in kinetic parameter estimation, particularly Ktrans and vp, through Tofts model fitting. MFA method should be more reliable and robust for accurate quantitative pharmacokinetic analysis in head and neck.
- 23 November 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (24) , 8185-8200
MR chemical exchange imaging with spin-lock technique (CESL): a theoretical analysis of the Z-spectrum using a two-poolR1ρrelaxation model beyond the fast-exchange limit
The chemical exchange (CE) process has been exploited as a novel and powerful contrast mechanism for MRI, which is primarily performed in the form of chemical exchange saturation transfer (CEST) imaging. A spin-lock (SL) technique can also be used for CE studies, although traditionally performed and interpreted quite differently from CEST. Chemical exchange imaging with spin-lock technique (CESL), theoretically based on the Bloch-McConnell equations common to CEST, has the potential to be used as an alternative to CEST and to better characterize CE processes from slow and intermediate to fast proton exchange rates through the tuning of spin-lock pulse parameters. In this study, the Z-spectrum and asymmetric magnetization transfer ratio (MTR(asym)) obtained by CESL are theoretically analyzed and numerically simulated using a general two-pool R(1ρ) relaxation model beyond the fast-exchange limit. The influences of spin-lock parameters, static magnetic field strength B(0) and physiological properties on the Z-spectrum and MTR(asym) are quantitatively revealed. Optimization of spin-lock frequency and spin-lock duration for the maximum CESL contrast enhancement is also investigated. Numerical simulation results in this study are compatible with the findings in the existing literature on CE imaging studies.
- 23 November 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (24) , 8185-8200
MR chemical exchange imaging with spin-lock technique (CESL): a theoretical analysis of the Z-spectrum using a two-poolR1ρrelaxation model beyond the fast-exchange limit
The chemical exchange (CE) process has been exploited as a novel and powerful contrast mechanism for MRI, which is primarily performed in the form of chemical exchange saturation transfer (CEST) imaging. A spin-lock (SL) technique can also be used for CE studies, although traditionally performed and interpreted quite differently from CEST. Chemical exchange imaging with spin-lock technique (CESL), theoretically based on the Bloch-McConnell equations common to CEST, has the potential to be used as an alternative to CEST and to better characterize CE processes from slow and intermediate to fast proton exchange rates through the tuning of spin-lock pulse parameters. In this study, the Z-spectrum and asymmetric magnetization transfer ratio (MTR(asym)) obtained by CESL are theoretically analyzed and numerically simulated using a general two-pool R(1ρ) relaxation model beyond the fast-exchange limit. The influences of spin-lock parameters, static magnetic field strength B(0) and physiological properties on the Z-spectrum and MTR(asym) are quantitatively revealed. Optimization of spin-lock frequency and spin-lock duration for the maximum CESL contrast enhancement is also investigated. Numerical simulation results in this study are compatible with the findings in the existing literature on CE imaging studies.
- 18 July 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (15) , 5003-5016
Quantification ofT1ρrelaxation by using rotary echo spin-lock pulses in the presence ofB0inhomogeneity
T(1ρ) relaxation is traditionally described as a mono-exponential signal decay with spin-lock time. However, T(1ρ) quantification by fitting to the mono-exponential model can be substantially compromised in the presence of field inhomogeneities, especially for low spin-lock frequencies. The normal approach to address this issue involves the development of dedicated composite spin-lock pulses for artifact reduction while still using the mono-exponential model for T(1ρ) fitting. In this work, we propose an alternative approach for improved T(1ρ) quantification with the widely-used rotary echo spin-lock pulses in the presence of B(0) inhomogeneities by fitting to a modified theoretical model which is derived to reveal the dependence of T(1ρ)-prepared magnetization on T(1ρ), T(2ρ), spin-lock time, spin-lock frequency and off-resonance, without involving complicated spin-lock pulse design. It has potentials for T(1ρ) quantification improvement at low spin-lock frequencies. Improved T(1ρ) mapping was demonstrated on phantom and in vivo rat spin-lock imaging at 3 T compared to the mapping using the mono-exponential model.
- 18 July 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (15) , 5003-5016
Quantification ofT1ρrelaxation by using rotary echo spin-lock pulses in the presence ofB0inhomogeneity
T(1ρ) relaxation is traditionally described as a mono-exponential signal decay with spin-lock time. However, T(1ρ) quantification by fitting to the mono-exponential model can be substantially compromised in the presence of field inhomogeneities, especially for low spin-lock frequencies. The normal approach to address this issue involves the development of dedicated composite spin-lock pulses for artifact reduction while still using the mono-exponential model for T(1ρ) fitting. In this work, we propose an alternative approach for improved T(1ρ) quantification with the widely-used rotary echo spin-lock pulses in the presence of B(0) inhomogeneities by fitting to a modified theoretical model which is derived to reveal the dependence of T(1ρ)-prepared magnetization on T(1ρ), T(2ρ), spin-lock time, spin-lock frequency and off-resonance, without involving complicated spin-lock pulse design. It has potentials for T(1ρ) quantification improvement at low spin-lock frequencies. Improved T(1ρ) mapping was demonstrated on phantom and in vivo rat spin-lock imaging at 3 T compared to the mapping using the mono-exponential model.
- 7 March 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (6) , 1631-1640
Optimized efficient liverT1ρmapping using limited spin lock times
T(1ρ) relaxation has recently been found to be sensitive to liver fibrosis and has potential to be used for early detection of liver fibrosis and grading. Liver T(1ρ) imaging and accurate mapping are challenging because of the long scan time, respiration motion and high specific absorption rate. Reduction and optimization of spin lock times (TSLs) are an efficient way to reduce scan time and radiofrequency energy deposition of T(1ρ) imaging, but maintain the near-optimal precision of T(1ρ) mapping. This work analyzes the precision in T(1ρ) estimation with limited, in particular two, spin lock times, and explores the feasibility of using two specific operator-selected TSLs for efficient and accurate liver T(1ρ) mapping. Two optimized TSLs were derived by theoretical analysis and numerical simulations first, and tested experimentally by in vivo rat liver T(1ρ) imaging at 3 T. The simulation showed that the TSLs of 1 and 50 ms gave optimal T(1ρ) estimation in a range of 10-100 ms. In the experiment, no significant statistical difference was found between the T(1ρ) maps generated using the optimized two-TSL combination and the maps generated using the six TSLs of [1, 10, 20, 30, 40, 50] ms according to one-way ANOVA analysis (p = 0.1364 for liver and p = 0.8708 for muscle).
- 7 March 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (6) , 1631-1640
Optimized efficient liverT1ρmapping using limited spin lock times
T(1ρ) relaxation has recently been found to be sensitive to liver fibrosis and has potential to be used for early detection of liver fibrosis and grading. Liver T(1ρ) imaging and accurate mapping are challenging because of the long scan time, respiration motion and high specific absorption rate. Reduction and optimization of spin lock times (TSLs) are an efficient way to reduce scan time and radiofrequency energy deposition of T(1ρ) imaging, but maintain the near-optimal precision of T(1ρ) mapping. This work analyzes the precision in T(1ρ) estimation with limited, in particular two, spin lock times, and explores the feasibility of using two specific operator-selected TSLs for efficient and accurate liver T(1ρ) mapping. Two optimized TSLs were derived by theoretical analysis and numerical simulations first, and tested experimentally by in vivo rat liver T(1ρ) imaging at 3 T. The simulation showed that the TSLs of 1 and 50 ms gave optimal T(1ρ) estimation in a range of 10-100 ms. In the experiment, no significant statistical difference was found between the T(1ρ) maps generated using the optimized two-TSL combination and the maps generated using the six TSLs of [1, 10, 20, 30, 40, 50] ms according to one-way ANOVA analysis (p = 0.1364 for liver and p = 0.8708 for muscle).
- Open Access
- 1 March 2012
- Vol. 2 (1) , 21-32-32
Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry
Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry
- 1 March 2012
- Vol. 2 (1) , 21-32-32
Open AccessTowards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry
Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry
- 1 March 2012
- Published by Elsevier in Clinical Radiology
- Vol. 67 (3) , 216-223
A five-colour colour-coded mapping method for DCE-MRI analysis of head and neck tumours
- 1 March 2012
- Published by Elsevier in Clinical Radiology
- Vol. 67 (3) , 216-223
A five-colour colour-coded mapping method for DCE-MRI analysis of head and neck tumours
- Open Access
- 16 November 2011
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 35 (4) , 916-925
Heuristic linear mapping of physiological parameters in dynamic contrast‐enhanced MRI without T1 measurement and contrast agent concentration
Purpose: To present a novel heuristic linear mapping method to individually estimate physiological parameters for Tofts model without T1 measurement and contrast agent concentration.Materials and Methods: A linear relationship was used for kep mapping through a heuristic time intensity curve (TIC) shape factor (TSF). Ktrans maps were subsequently estimated using kep maps and another approximate linear model derived from the Tofts model. Twenty‐seven patients with head‐and‐neck squamous cell carcinoma received dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI). Physiological parameters maps were obtained using this heuristic linear mapping method and compared to the maps obtained by the normal nonlinear least‐square fitting with T1 measurement.Results: High linearity (R2 >0.95) between kep and TSF was found in all patients for kep 0.05). The Ktrans maps were consistent with the normally derived maps in pattern distribution but the absolute value might be scaled due to the assumption of the reference Ktrans value.Conclusion: This novel method generates reliable and consistent physiological parameter maps with significantly lower computation complexity than the multiparameter nonlinear fitting. The DCE‐MRI scan time can be greatly shortened without T1 mapping. J. Magn. Reson. Imaging 2012;35:916–925.
- 16 November 2011
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 35 (4) , 916-925
Open AccessHeuristic linear mapping of physiological parameters in dynamic contrast‐enhanced MRI without T1 measurement and contrast agent concentration
Purpose: To present a novel heuristic linear mapping method to individually estimate physiological parameters for Tofts model without T1 measurement and contrast agent concentration.Materials and Methods: A linear relationship was used for kep mapping through a heuristic time intensity curve (TIC) shape factor (TSF). Ktrans maps were subsequently estimated using kep maps and another approximate linear model derived from the Tofts model. Twenty‐seven patients with head‐and‐neck squamous cell carcinoma received dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI). Physiological parameters maps were obtained using this heuristic linear mapping method and compared to the maps obtained by the normal nonlinear least‐square fitting with T1 measurement.Results: High linearity (R2 >0.95) between kep and TSF was found in all patients for kep 0.05). The Ktrans maps were consistent with the normally derived maps in pattern distribution but the absolute value might be scaled due to the assumption of the reference Ktrans value.Conclusion: This novel method generates reliable and consistent physiological parameter maps with significantly lower computation complexity than the multiparameter nonlinear fitting. The DCE‐MRI scan time can be greatly shortened without T1 mapping. J. Magn. Reson. Imaging 2012;35:916–925.
- 1 May 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 210 (1) , 38-43
Fast fat-suppressed reduced field-of-view temperature mapping using 2DRF excitation pulses
- 1 May 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 210 (1) , 38-43
Fast fat-suppressed reduced field-of-view temperature mapping using 2DRF excitation pulses
- 28 February 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 208 (2) , 219-224
Fat–water selective excitation in balanced steady-state free precession using short spatial–spectral RF pulses
- 28 February 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 208 (2) , 219-224
Fat–water selective excitation in balanced steady-state free precession using short spatial–spectral RF pulses