Jeffrey C. Lotz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jeffrey C. Lotz has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Aaron J. Fields
Department of Orthopaedic Surgery, University of California, San Francisco, USA
4 shared publications Dezba Coughlin
4 shared publicationsEllen C. Liebenberg
University of California, San Francisco, California
4 shared publicationsAliza A. Allon
Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, CA, USA
3 shared publicationsAzucena G. Rodriguez
Orthopaedic Bioengineering Laboratory, Department of Orthopaedic Surgery, University of California, San Francisco, CA
3 shared publicationsJane Liu
Department of Orthopaedic Surgery; University of California; San Francisco CA 94143 USA
3 shared publications
Latest Publications
- 1 October 2017
- Published by Elsevier in The Spine Journal
- Vol. 17 (10) , S95-S96
From the International Space Station to the Clinic: How Prolonged Unloading May Disrupt Lumbar Stability
- 1 October 2017
- Published by Elsevier in The Spine Journal
- Vol. 17 (10) , S95-S96
From the International Space Station to the Clinic: How Prolonged Unloading May Disrupt Lumbar Stability
- 1 June 2016
- Published by Elsevier in The Spine Journal
- Vol. 16 (6) , 770-776
Pulsed electromagnetic field (PEMF) treatment reduces expression of genes associated with disc degeneration in human intervertebral disc cells
- 1 June 2016
- Published by Elsevier in The Spine Journal
- Vol. 16 (6) , 770-776
Pulsed electromagnetic field (PEMF) treatment reduces expression of genes associated with disc degeneration in human intervertebral disc cells
- 1 October 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (10) , S99
BMP Decreases Risk of One-Year Revision in Primary Multilevel Anterior Column Fusion: A Longitudinal Analysis of 2,053 Patients
- 1 October 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (10) , S99
BMP Decreases Risk of One-Year Revision in Primary Multilevel Anterior Column Fusion: A Longitudinal Analysis of 2,053 Patients
- 24 September 2015
- Published by Springer Nature in European Spine Journal
- Vol. 25 (9) , 2889-2897
The effect of simulated microgravity on lumbar spine biomechanics: an in vitro study
Purpose Disc herniation risk is quadrupled following spaceflight. This study tested the hypothesis that swelling-induced disc height increases (comparable to those reported in spaceflight) stiffen the spine and elevate annular strain and nuclear pressure during forward bending. Methods Eight human lumbar motion segments were secured to custom-designed testing jigs and subjected to baseline flexion and compression and pure moment flexibility tests. Discs were then free-swelled in saline to varying supraphysiologic heights consistent with prolonged weightlessness and re-tested to assess biomechanical changes. Results Swelling-induced disc height changes correlated positively with intradiscal pressure (p < 0.01) and stiffening in flexion (p < 0.01), and negatively with flexion range of motion (p < 0.05). Swelling-induced increases in disc height also led to increased annular surface strain under combined flexion with compression. Disc wedge angle decreased with swelling (p < 0.05); this loss of wedge angle correlated with decreased flexion range of motion (R 2 = 0.94, p < 0.0001) and decreased stiffness fold change in extension (p < 0.05). Conclusion Swelling-induced increases in disc height decrease flexibility and increase annular strain and nuclear pressure during forward bending. These changes, in combination with the measured loss of lordotic curvature with disc swelling, may contribute toward increased herniation risk. This is consistent with clinical observations of increased disc herniation rates after microgravity exposure and may provide the basis for future countermeasure development.
- 24 September 2015
- Published by Springer Nature in European Spine Journal
- Vol. 25 (9) , 2889-2897
The effect of simulated microgravity on lumbar spine biomechanics: an in vitro study
Purpose Disc herniation risk is quadrupled following spaceflight. This study tested the hypothesis that swelling-induced disc height increases (comparable to those reported in spaceflight) stiffen the spine and elevate annular strain and nuclear pressure during forward bending. Methods Eight human lumbar motion segments were secured to custom-designed testing jigs and subjected to baseline flexion and compression and pure moment flexibility tests. Discs were then free-swelled in saline to varying supraphysiologic heights consistent with prolonged weightlessness and re-tested to assess biomechanical changes. Results Swelling-induced disc height changes correlated positively with intradiscal pressure (p < 0.01) and stiffening in flexion (p < 0.01), and negatively with flexion range of motion (p < 0.05). Swelling-induced increases in disc height also led to increased annular surface strain under combined flexion with compression. Disc wedge angle decreased with swelling (p < 0.05); this loss of wedge angle correlated with decreased flexion range of motion (R 2 = 0.94, p < 0.0001) and decreased stiffness fold change in extension (p < 0.05). Conclusion Swelling-induced increases in disc height decrease flexibility and increase annular strain and nuclear pressure during forward bending. These changes, in combination with the measured loss of lordotic curvature with disc swelling, may contribute toward increased herniation risk. This is consistent with clinical observations of increased disc herniation rates after microgravity exposure and may provide the basis for future countermeasure development.
- Open Access
- 18 August 2015
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 34 (1) , 48-57
Spaceflight‐induced bone loss alters failure mode and reduces bending strength in murine spinal segments
Intervertebral disc herniation rates are quadrupled in astronauts following spaceflight. While bending motions are main contributors to herniation, the effects of microgravity on the bending properties of spinal discs are unknown. Consequently, the goal of this study was to quantify the bending properties of tail discs from mice with or without microgravity exposure. Caudal motion segments from six mice returned from a 30‐day Bion M1 mission and eight vivarium controls were loaded to failure in four‐point bending. After testing, specimens were processed using histology to determine the location of failure, and adjacent motion segments were scanned with micro‐computed tomography (μCT) to quantify bone properties. We observed that spaceflight significantly shortened the nonlinear toe region of the force‐displacement curve by 32% and reduced the bending strength by 17%. Flight mouse spinal segments tended to fail within the growth plate and epiphyseal bone, while controls tended to fail at the disc‐vertebra junction. Spaceflight significantly reduced vertebral bone volume fraction, bone mineral density, and trabecular thickness, which may explain the tendency of flight specimens to fail within the epiphyseal bone. Together, these results indicate that vertebral bone loss during spaceflight may degrade spine bending properties and contribute to increased disc herniation risk in astronauts. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:48–57, 2016.
- 18 August 2015
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 34 (1) , 48-57
Open AccessSpaceflight‐induced bone loss alters failure mode and reduces bending strength in murine spinal segments
Intervertebral disc herniation rates are quadrupled in astronauts following spaceflight. While bending motions are main contributors to herniation, the effects of microgravity on the bending properties of spinal discs are unknown. Consequently, the goal of this study was to quantify the bending properties of tail discs from mice with or without microgravity exposure. Caudal motion segments from six mice returned from a 30‐day Bion M1 mission and eight vivarium controls were loaded to failure in four‐point bending. After testing, specimens were processed using histology to determine the location of failure, and adjacent motion segments were scanned with micro‐computed tomography (μCT) to quantify bone properties. We observed that spaceflight significantly shortened the nonlinear toe region of the force‐displacement curve by 32% and reduced the bending strength by 17%. Flight mouse spinal segments tended to fail within the growth plate and epiphyseal bone, while controls tended to fail at the disc‐vertebra junction. Spaceflight significantly reduced vertebral bone volume fraction, bone mineral density, and trabecular thickness, which may explain the tendency of flight specimens to fail within the epiphyseal bone. Together, these results indicate that vertebral bone loss during spaceflight may degrade spine bending properties and contribute to increased disc herniation risk in astronauts. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:48–57, 2016.
- 1 November 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (11) , S167
Pulsed Electromagnetic Fields (PEMF) Inhibit Matrix Metalloproteinase-13 Expression in Human Annulus Fibrosus Cells
- 1 November 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (11) , S167
Pulsed Electromagnetic Fields (PEMF) Inhibit Matrix Metalloproteinase-13 Expression in Human Annulus Fibrosus Cells
- 1 March 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (3) , 513-521
Innervation of pathologies in the lumbar vertebral end plate and intervertebral disc
- 1 March 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (3) , 513-521
Innervation of pathologies in the lumbar vertebral end plate and intervertebral disc
- 1 March 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (3) , 522-530
Intervertebral discs from spinal nondeformity and deformity patients have different mechanical and matrix properties
- 1 March 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (3) , 522-530
Intervertebral discs from spinal nondeformity and deformity patients have different mechanical and matrix properties
- Open Access
- 23 November 2013
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 32 (2) , 245-252
Influence of biochemical composition on endplate cartilage tensile properties in the human lumbar spine
Endplate cartilage integrity is critical to spine health and is presumably impaired by deterioration in biochemical composition. Yet, quantitative relationships between endplate biochemical composition and biomechanical properties are unavailable. Using endplate cartilage harvested from human lumbar spines (six donors, ages 51–67 years) we showed that endplate biochemical composition has a significant influence on its equilibrium tensile properties and that the presence of endplate damage associates with a diminished composition–function relationship. We found that the equilibrium tensile modulus (5.9 ± 5.7 MPa) correlated significantly with collagen content (559 ± 147 µg/mg dry weight, r2 = 0.35) and with the collagen/GAG ratio (6.0 ± 2.1, r2 = 0.58). Accounting for the damage status of the adjacent cartilage improved the latter correlation (r2 = 0.77) and indicated that samples with adjacent damage such as fissures and avulsions had a diminished modulus–collagen/GAG relationship (p = 0.02). Quasi‐linear viscoelastic relaxation properties (C, τ1, and τ2) did not correlate with biochemical composition. We conclude that reduced matrix quantity decreases the equilibrium tensile modulus of human endplate cartilage and that characteristics of biochemical composition that are independent of matrix quantity, that is, characteristics related to matrix quality, may also be important. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:245–252, 2014.
- 23 November 2013
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 32 (2) , 245-252
Open AccessInfluence of biochemical composition on endplate cartilage tensile properties in the human lumbar spine
Endplate cartilage integrity is critical to spine health and is presumably impaired by deterioration in biochemical composition. Yet, quantitative relationships between endplate biochemical composition and biomechanical properties are unavailable. Using endplate cartilage harvested from human lumbar spines (six donors, ages 51–67 years) we showed that endplate biochemical composition has a significant influence on its equilibrium tensile properties and that the presence of endplate damage associates with a diminished composition–function relationship. We found that the equilibrium tensile modulus (5.9 ± 5.7 MPa) correlated significantly with collagen content (559 ± 147 µg/mg dry weight, r2 = 0.35) and with the collagen/GAG ratio (6.0 ± 2.1, r2 = 0.58). Accounting for the damage status of the adjacent cartilage improved the latter correlation (r2 = 0.77) and indicated that samples with adjacent damage such as fissures and avulsions had a diminished modulus–collagen/GAG relationship (p = 0.02). Quasi‐linear viscoelastic relaxation properties (C, τ1, and τ2) did not correlate with biochemical composition. We conclude that reduced matrix quantity decreases the equilibrium tensile modulus of human endplate cartilage and that characteristics of biochemical composition that are independent of matrix quantity, that is, characteristics related to matrix quality, may also be important. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:245–252, 2014.
- 30 September 2013
- Published by Elsevier in The Spine Journal
- Vol. 13 (9) , S101
Single Voxel MR Spectroscopy Distinguishes Nonherniated Painful from Herniated Painful and Non-Painful Lumbar Discs
- 30 September 2013
- Published by Elsevier in The Spine Journal
- Vol. 13 (9) , S101
Single Voxel MR Spectroscopy Distinguishes Nonherniated Painful from Herniated Painful and Non-Painful Lumbar Discs