Oliver F. Adunka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oliver F. Adunka has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Craig A. Buchman
Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A.
8 shared publications- Craig A. Buchman
Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, NC
6 shared publications Adam P. Campbell
Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A.
5 shared publicationsDouglas C. Fitzpatrick
Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A.
5 shared publicationsHarold C. Pillsbury
4 shared publicationsThomas A. Suberman
Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-7070, USA
4 shared publications
Latest Publications
- 1 April 2015
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 36 (4) , 670-677
Effect of Cochlear Nerve Electrocautery on the Adult Cochlear Nucleus
Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.
- 1 April 2015
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 36 (4) , 670-677
Effect of Cochlear Nerve Electrocautery on the Adult Cochlear Nucleus
Electrocauterization and subsequent transection of the cochlear nerve induce greater injury to the cochlear nucleus than sharp transection alone. Some studies show that neurofibromatosis Type 2 (NF2) patients fit with auditory brainstem implants (ABIs) fail to achieve speech perception abilities similar to ABI recipients without NF2. Reasons for these differences remain speculative. One hypothesis posits poorer performance to surgically induced trauma to the cochlear nucleus from electrocautery. Sustained electrosurgical depolarization of the cochlear nerve may cause excitotoxic-induced postsynaptic nuclear injury. Equally plausible is that cautery in the vicinity of the cochlear nucleus induces necrosis. The cochlear nerve was transected in anesthetized adult gerbils sharply with or without bipolar electrocautery at varying intensities. Gerbils were perfused at 1, 3, 5, and 7 days postoperatively; their brainstem and cochleas were embedded in paraffin and sectioned at 10 μm. Alternate sections were stained with flourescent markers for neuronal injury or Nissl substance. In additional experiments, anterograde tracers were applied directly to a sectioned eighth nerve to verify that fluorescent-labeled profiles seen were terminating auditory nerve fibers. Cochlear nerve injury was observed from 72 hours postoperatively and was identical across cases regardless of surgical technique. Postsynaptic cochlear nucleus injury was not seen after distal transection of the nerve. By contrast, proximal transection was associated with trauma to the cochlear nucleus. Distal application of bipolar electrocautery seems safe for the cochlear nucleus. Application near the root entry zone must be used cautiously because this may compromise nuclear viability needed to support ABI stimulation.
- 24 January 2014
- Published by Wiley in The Laryngoscope
- Vol. 124 (8) , 1928-1931
Scala tympani cochleostomy survey: A follow‐up study
Objectives/Hypothesis To reassess cochleostomy techniques among North American cochlear implant surgeons after a 6-year period of widespread education and research on the topic. Study Design Prospective cohort study. Methods A multiple-choice survey of cochlear implant techniques was distributed to surgeons attending the William House Cochlear Implant Study Group in 2006 and 2012. This survey contained questions regarding routine surgical access and cochleostomy techniques. Responses were anonymous, and >50% were repeat respondents. Statistical analysis sought changes in technique in the past 6 years. Results Comparisons between 2006 and 2012 responses revealed no significant changes in the proportion of surgeons identifying the facial nerve or chorda tympani. By contrast, respondents in 2012 were more likely to drill off the round window niche overhang (P < .001), use a round window insertion (P < .001), or make a smaller cochleostomy (P = .003). In two images of a transfacial recess approach, there was a significant increase in the proportion choosing an inferior or anterior cochleostomy site over a superior location (image 1, 76% in 2006 to 92% in 2012, P = .003; image 3, 78% to 90%, respectively, P = .044). Conclusions This repeat survey documents a change in practice among cochlear implant surgeons. Specifically, scala tympani access techniques now appear to be more consistent with known anatomical relationships in the round window region. These findings may have resulted from the concerted education and research efforts over the past 6 years. Level of Evidence 4. Laryngoscope, 124:1928–1931, 2014
- 24 January 2014
- Published by Wiley in The Laryngoscope
- Vol. 124 (8) , 1928-1931
Scala tympani cochleostomy survey: A follow‐up study
Objectives/Hypothesis To reassess cochleostomy techniques among North American cochlear implant surgeons after a 6-year period of widespread education and research on the topic. Study Design Prospective cohort study. Methods A multiple-choice survey of cochlear implant techniques was distributed to surgeons attending the William House Cochlear Implant Study Group in 2006 and 2012. This survey contained questions regarding routine surgical access and cochleostomy techniques. Responses were anonymous, and >50% were repeat respondents. Statistical analysis sought changes in technique in the past 6 years. Results Comparisons between 2006 and 2012 responses revealed no significant changes in the proportion of surgeons identifying the facial nerve or chorda tympani. By contrast, respondents in 2012 were more likely to drill off the round window niche overhang (P < .001), use a round window insertion (P < .001), or make a smaller cochleostomy (P = .003). In two images of a transfacial recess approach, there was a significant increase in the proportion choosing an inferior or anterior cochleostomy site over a superior location (image 1, 76% in 2006 to 92% in 2012, P = .003; image 3, 78% to 90%, respectively, P = .044). Conclusions This repeat survey documents a change in practice among cochlear implant surgeons. Specifically, scala tympani access techniques now appear to be more consistent with known anatomical relationships in the round window region. These findings may have resulted from the concerted education and research efforts over the past 6 years. Level of Evidence 4. Laryngoscope, 124:1928–1931, 2014
- 1 September 2013
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 34 (7) , 1311-1315
Cost of Cholesteatoma Care at a Tertiary Medical Center
Estimate the available direct cost of cholesteatoma care in a university practice. Retrospective review of both physician and hospital financial data during a recent 3-year period. University-based tertiary referral medical system. Adults (≥ 18 yr old) with cholesteatoma. Financial information associated with both physician and hospital encounters were analyzed in a deidentified manner. Frequency and type of encounter, charges, collections, and payers were tabulated. Approximately 949 physician encounters (817 clinic, 130 surgical, and 2 inpatient) among 344 patients resulted in greater than $700, 000 in charges and greater than $211,000 in receipts (≈ 30% rate of collection). The average physician charge per patient per year was approximately $1,600. About 259 hospital encounters among 171 patients resulted in greater than $1.8 million in charges and greater than $520,000 in receipts (≈ 28% collection rate). The average hospital charge per patient per year was ∼$10,000. For physician encounters, managed care (37%) and Medicare (25%) were the most common payers, whereas 17% were uninsured. For hospital encounters, managed care (28%) and Medicare (14%) were the most common payers, whereas 24% were uninsured. The direct cost of care for patients with cholesteatoma is significant. The current treatment paradigm for this chronic disorder results in repeated health care system access and associated direct (and unmeasured indirect) expenses. Future treatment paradigms should be designed to improve disease-specific quality of life while mitigating this financial impact.
- 1 September 2013
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 34 (7) , 1311-1315
Cost of Cholesteatoma Care at a Tertiary Medical Center
Estimate the available direct cost of cholesteatoma care in a university practice. Retrospective review of both physician and hospital financial data during a recent 3-year period. University-based tertiary referral medical system. Adults (≥ 18 yr old) with cholesteatoma. Financial information associated with both physician and hospital encounters were analyzed in a deidentified manner. Frequency and type of encounter, charges, collections, and payers were tabulated. Approximately 949 physician encounters (817 clinic, 130 surgical, and 2 inpatient) among 344 patients resulted in greater than $700, 000 in charges and greater than $211,000 in receipts (≈ 30% rate of collection). The average physician charge per patient per year was approximately $1,600. About 259 hospital encounters among 171 patients resulted in greater than $1.8 million in charges and greater than $520,000 in receipts (≈ 28% collection rate). The average hospital charge per patient per year was ∼$10,000. For physician encounters, managed care (37%) and Medicare (25%) were the most common payers, whereas 17% were uninsured. For hospital encounters, managed care (28%) and Medicare (14%) were the most common payers, whereas 24% were uninsured. The direct cost of care for patients with cholesteatoma is significant. The current treatment paradigm for this chronic disorder results in repeated health care system access and associated direct (and unmeasured indirect) expenses. Future treatment paradigms should be designed to improve disease-specific quality of life while mitigating this financial impact.
- 1 January 2013
- Published by Springer Nature
- p. 2155-2159
Physiology of Cochlea
- 1 December 2012
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 33 (9) , 1507-1515
Intraoperative Round Window Recordings to Acoustic Stimuli From Cochlear Implant Patients
Hypothesis Acoustically evoked neural and hair cell potentials can be measured from the round window (RW) intraoperatively in the general population of cochlear implant recipients. Background Cochlear implant performance varies greatly among patients. Improved methods to assess and monitor functional hair cell and neural substrate before and during implantation could potentially aid in enhanced nontraumatic intracochlear electrode placement and subsequent improved outcomes. Methods Subjects (1–80 yr) undergoing cochlear implantation were included. A monopolar probe was placed at the RW after surgical access was obtained. The cochlear microphonic (CM), summating potential (SP), compound action potential (CAP), and auditory nerve neurophonic (ANN) were recorded in response to tone bursts at frequencies of 0.25 to 4 kHz at various levels. Results Measurable hair cell/neural potentials were detected to 1 or more frequencies in 23 of 25 subjects. The greatest proportion and magnitude of cochlear responses were to low frequencies (<1,000 Hz). At these low frequencies, the ANN, when present, contributed to the ongoing response at the stimulus frequency. In many subjects, the ANN was small or absent, whereas hair cell responses remained. Conclusion In cochlear implant recipients, acoustically evoked cochlear potentials are detectable even if hearing is extremely limited. Sensitive measures of cochlear and neural status can characterize the state of hair cell and neural function before implantation. Whether this information correlates with speech performance outcomes or can help in tailoring electrode type, placement or audiometric fitting, can be determined in future studies.
- 1 December 2012
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 33 (9) , 1507-1515
Intraoperative Round Window Recordings to Acoustic Stimuli From Cochlear Implant Patients
Hypothesis Acoustically evoked neural and hair cell potentials can be measured from the round window (RW) intraoperatively in the general population of cochlear implant recipients. Background Cochlear implant performance varies greatly among patients. Improved methods to assess and monitor functional hair cell and neural substrate before and during implantation could potentially aid in enhanced nontraumatic intracochlear electrode placement and subsequent improved outcomes. Methods Subjects (1–80 yr) undergoing cochlear implantation were included. A monopolar probe was placed at the RW after surgical access was obtained. The cochlear microphonic (CM), summating potential (SP), compound action potential (CAP), and auditory nerve neurophonic (ANN) were recorded in response to tone bursts at frequencies of 0.25 to 4 kHz at various levels. Results Measurable hair cell/neural potentials were detected to 1 or more frequencies in 23 of 25 subjects. The greatest proportion and magnitude of cochlear responses were to low frequencies (<1,000 Hz). At these low frequencies, the ANN, when present, contributed to the ongoing response at the stimulus frequency. In many subjects, the ANN was small or absent, whereas hair cell responses remained. Conclusion In cochlear implant recipients, acoustically evoked cochlear potentials are detectable even if hearing is extremely limited. Sensitive measures of cochlear and neural status can characterize the state of hair cell and neural function before implantation. Whether this information correlates with speech performance outcomes or can help in tailoring electrode type, placement or audiometric fitting, can be determined in future studies.
- Open Access
- 26 November 2011
- Published by Wiley in The Laryngoscope
- Vol. 122 (3) , 636-644
Detection of intracochlear damage during cochlear implant electrode insertion using extracochlear measurements in the gerbil
Objectives/Hypothesis: An intraoperative monitoring algorithm during cochlear implant electrode insertion could be used to detect trauma and guide electrode placement relative to surviving hair cells. The aim of this report was to assess the feasibility of using extracochlear recording sites to monitor acoustically evoked responses from surviving hair cells and neural elements during implantation in an animal model.Study Design: Animal experiments.Methods: The normal‐hearing gerbil was used. Two recording methods, one using a lock‐in amplifier and another using Fourier analysis of recorded signals, were used to obtain frequency‐specific information about the responses to tones. Amplitude and threshold determinations were made at the round window and at three extracochlear sites. To induce intracochlear damage, a platinum‐iridium wire was inserted through the round window. The wire was advanced, and changes in the potentials were correlated with cochlear contact. Anatomic integrity was assessed using cochlea whole mount preparations.Results: In general, the lock‐in amplifier showed greater sensitivity and lower thresholds at higher frequencies relative to the Fourier method. Also, the lock‐in amplifier was more resistant to masking effects. Both systems were able to detect loss of cochlear potentials secondary to intracochlear trauma. Histologic damage was seen in all cases and corresponded to electrophysiologic changes.Conclusions: Impact of electrodes on cochlear structures affecting cochlear performance could be detected from several extracochlear sites. The lock‐in amplifier demonstrated greater sensitivity and resistance to noise when compared to the fast Fourier transform recording paradigm. The latter showed greater flexibility of detecting and separating hair cell and neural potentials.
- 26 November 2011
- Published by Wiley in The Laryngoscope
- Vol. 122 (3) , 636-644
Open AccessDetection of intracochlear damage during cochlear implant electrode insertion using extracochlear measurements in the gerbil
Objectives/Hypothesis: An intraoperative monitoring algorithm during cochlear implant electrode insertion could be used to detect trauma and guide electrode placement relative to surviving hair cells. The aim of this report was to assess the feasibility of using extracochlear recording sites to monitor acoustically evoked responses from surviving hair cells and neural elements during implantation in an animal model.Study Design: Animal experiments.Methods: The normal‐hearing gerbil was used. Two recording methods, one using a lock‐in amplifier and another using Fourier analysis of recorded signals, were used to obtain frequency‐specific information about the responses to tones. Amplitude and threshold determinations were made at the round window and at three extracochlear sites. To induce intracochlear damage, a platinum‐iridium wire was inserted through the round window. The wire was advanced, and changes in the potentials were correlated with cochlear contact. Anatomic integrity was assessed using cochlea whole mount preparations.Results: In general, the lock‐in amplifier showed greater sensitivity and lower thresholds at higher frequencies relative to the Fourier method. Also, the lock‐in amplifier was more resistant to masking effects. Both systems were able to detect loss of cochlear potentials secondary to intracochlear trauma. Histologic damage was seen in all cases and corresponded to electrophysiologic changes.Conclusions: Impact of electrodes on cochlear structures affecting cochlear performance could be detected from several extracochlear sites. The lock‐in amplifier demonstrated greater sensitivity and resistance to noise when compared to the fast Fourier transform recording paradigm. The latter showed greater flexibility of detecting and separating hair cell and neural potentials.
- 15 August 2011
- Published by Wiley in The Laryngoscope
- Vol. 121 (S5) , S311
Electrophysiological Insertion Properties in the Gerbil Using a Flexible Array
- 15 August 2011
- Published by Wiley in The Laryngoscope
- Vol. 121 (S5) , S311
Electrophysiological Insertion Properties in the Gerbil Using a Flexible Array
- 1 June 2011
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (4) , 544-552
A Gerbil Model of Sloping Sensorineural Hearing Loss
Objective: The goal of the overall project is to develop knowledge about cochlear physiology during cochlear implantation and develop procedures for assessing its status during hearing preservation surgery. As a step toward this goal, for this study, we established an animal model of sloping high frequency sensorineural hearing loss that mimics the hearing condition of candidates for combined electric-acoustic stimulation. Methods: Mongolian gerbils were exposed to band-pass noise using various cutoff frequencies, intensities, exposure times, and survival times. Hearing loss was assessed in far-field recording using preexposure and postexposure auditory brainstem responses (ABRs), and in acute, near-field recordings of the cochlear microphonic and compound action potential from an electrode on the round window. Anatomic loss of hair cells was assessed from dissections. Results: Postexposure ABRs and near-field recordings from the round window revealed sensorineural hearing loss that varied with the overall noise exposure. Loss of hair cells ranged from relatively sparse to large areas of complete absence depending on the noise exposure. Cases with high intensity (120 dB SPL) and long exposure times (3 h) showed sloping patterns of hearing loss with profound high-frequency loss and mild-to-moderate low-frequency loss. These cases showed complete loss of hair cells in the basal cochlea and preserved hair cells in the apical cochlea. The frequencies comprising the slope in the ABRs and the location of the transition zone between preserved and lost hair cells varied according to the cutoff frequency used. Conclusion: We were able to reliably induce sensorineural hearing loss and loss of hair cells in the gerbil that is comparable to candidates for hearing preservation surgery. This model can be used to evaluate the effects of electrode introduction in a system with a hearing condition similar to that in cases of hearing preservation operations.
- 1 June 2011
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (4) , 544-552
A Gerbil Model of Sloping Sensorineural Hearing Loss
Objective: The goal of the overall project is to develop knowledge about cochlear physiology during cochlear implantation and develop procedures for assessing its status during hearing preservation surgery. As a step toward this goal, for this study, we established an animal model of sloping high frequency sensorineural hearing loss that mimics the hearing condition of candidates for combined electric-acoustic stimulation. Methods: Mongolian gerbils were exposed to band-pass noise using various cutoff frequencies, intensities, exposure times, and survival times. Hearing loss was assessed in far-field recording using preexposure and postexposure auditory brainstem responses (ABRs), and in acute, near-field recordings of the cochlear microphonic and compound action potential from an electrode on the round window. Anatomic loss of hair cells was assessed from dissections. Results: Postexposure ABRs and near-field recordings from the round window revealed sensorineural hearing loss that varied with the overall noise exposure. Loss of hair cells ranged from relatively sparse to large areas of complete absence depending on the noise exposure. Cases with high intensity (120 dB SPL) and long exposure times (3 h) showed sloping patterns of hearing loss with profound high-frequency loss and mild-to-moderate low-frequency loss. These cases showed complete loss of hair cells in the basal cochlea and preserved hair cells in the apical cochlea. The frequencies comprising the slope in the ABRs and the location of the transition zone between preserved and lost hair cells varied according to the cutoff frequency used. Conclusion: We were able to reliably induce sensorineural hearing loss and loss of hair cells in the gerbil that is comparable to candidates for hearing preservation surgery. This model can be used to evaluate the effects of electrode introduction in a system with a hearing condition similar to that in cases of hearing preservation operations.
- 13 January 2011
- Published by Wiley in The Laryngoscope
- Vol. 121 (2) , 352-357
Large vestibular aqueduct syndrome
Objectives/Hypothesis: To correlate imaging and audiologic findings in patients with large vestibular aqueduct syndrome (LVAS).Study Design: Retrospective analysis.Methods: Thirty‐eight patients with LVAS evident on magnetic resonance imaging with available clinical and audiometric data were selected from the databases of the study institution. Images were analyzed for endolymphatic sac and duct size, evidence of incomplete cochlear partitioning, and endolymphatic sac signal heterogeneity. The endolymphatic duct was measured in two different locations: near the vestibular aperture (EDVA) and at the midpoint between the common crus and the operculum (EDMID). Imaging data were correlated with audiologic variables.Results: There was significant correlation between ears for the audiologic and anatomic variables collected. Twenty‐one (62%) patients had a fluctuating or progressive hearing loss, and 13 (38%) remained stable (four were not evaluable). At the time of the analysis, 41% of ears had a profound loss. Significant correlation was identified between the presence of endolymphatic signal heterogeneity and worse pure tone average (PTA). EDVA measures were significantly larger among ears with a progressive pattern of hearing loss when compared to those that were stable. Also, EDVA correlated with PTA and the presence of progressive hearing loss, but EDMID had no such a relationship.Conclusions: Evidence of endolymphatic sac signal heterogeneity and larger measures of endolymphatic width when measured near the vestibule (EDVA) are markers of poorer hearing in these patients. By contrast, midpoint measures of the endolymphatic duct (EDMID) have no correlation with audiometric parameters.
- 13 January 2011
- Published by Wiley in The Laryngoscope
- Vol. 121 (2) , 352-357
Large vestibular aqueduct syndrome
Objectives/Hypothesis: To correlate imaging and audiologic findings in patients with large vestibular aqueduct syndrome (LVAS).Study Design: Retrospective analysis.Methods: Thirty‐eight patients with LVAS evident on magnetic resonance imaging with available clinical and audiometric data were selected from the databases of the study institution. Images were analyzed for endolymphatic sac and duct size, evidence of incomplete cochlear partitioning, and endolymphatic sac signal heterogeneity. The endolymphatic duct was measured in two different locations: near the vestibular aperture (EDVA) and at the midpoint between the common crus and the operculum (EDMID). Imaging data were correlated with audiologic variables.Results: There was significant correlation between ears for the audiologic and anatomic variables collected. Twenty‐one (62%) patients had a fluctuating or progressive hearing loss, and 13 (38%) remained stable (four were not evaluable). At the time of the analysis, 41% of ears had a profound loss. Significant correlation was identified between the presence of endolymphatic signal heterogeneity and worse pure tone average (PTA). EDVA measures were significantly larger among ears with a progressive pattern of hearing loss when compared to those that were stable. Also, EDVA correlated with PTA and the presence of progressive hearing loss, but EDMID had no such a relationship.Conclusions: Evidence of endolymphatic sac signal heterogeneity and larger measures of endolymphatic width when measured near the vestibule (EDVA) are markers of poorer hearing in these patients. By contrast, midpoint measures of the endolymphatic duct (EDMID) have no correlation with audiometric parameters.