Todd T. Schlegel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Todd T. Schlegel has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Alan H. Feiveson
Human Adaptation and Countermeasures Office, National Aeronautics and Space Administration, Lyndon B. Johnson Space Center, Houston, TX 77058, USA
2 shared publicationsWalter B. Kulecz
Wyle Science, Technology & Engineering Group, Houston, Texas, United States of America
2 shared publicationsAdam J. Black
University of Minnesota, Minneapolis, Minnesota, United States of America
1 shared publication- Alan H. Feiveson
NASA Johnson Space Center, Houston, TX 77058, USA
1 shared publication - Andrzej Jaroszyński
Collegium Medicum, Jan Kochanowski University, 25-516 Kielce, Poland
1 shared publication - Bojan Vrtovec
Advanced Heart Failure Center, Department of Cardiology, Ljubljana University Medical Center, Ljubljana, Slovenia
1 shared publication
Latest Publications
- Open Access
- 19 May 2022
- Published by Wiley in Mediators of Inflammation
- Vol. 2022, 1-6
Heat Shock Protein 27 Levels Predict Myocardial Inhomogeneities in Hemodialysis Patients
Background. Sudden cardiac death (SCD) is the single major cause of death in hemodialysis (HD) patients. QRS-T angle is an established marker of global repolarization heterogeneity associated with electrical instability and SCD. Heat shock protein 27 (HSP27) plays an important, protective role against noxious factors in the cardiovascular (CV) system. This study is aimed at assessing whether low HSP27 is associated with myocardial inhomogeneities in HD patients, as expressed by increases in the spatial QRS-T angle. Methods. Clinical data and biochemical, echocardiographic, and electrocardiographic parameters were evaluated in 182 HD patients. Patients were split into normal and abnormal QRS-T angle groups. Results. Patients with abnormally high QRS-T angles were older and had higher prevalence of diabetes as well as myocardial infarction, higher left ventricular mass index (LVMI) and C-reactive protein, worse oxidant/antioxidant status, and lower ejection fraction and HSP27. Multiple regression analysis revealed that abnormal QRS-T values were independently, negatively associated with serum HSP27 and positively associated with LVMI. Conclusions. Low HSP27 levels are associated with increased heterogeneity of myocardial action potential, as expressed by increased spatial QRS-T angle.
- 19 May 2022
- Published by Wiley in Mediators of Inflammation
- Vol. 2022, 1-6
Open AccessHeat Shock Protein 27 Levels Predict Myocardial Inhomogeneities in Hemodialysis Patients
Background. Sudden cardiac death (SCD) is the single major cause of death in hemodialysis (HD) patients. QRS-T angle is an established marker of global repolarization heterogeneity associated with electrical instability and SCD. Heat shock protein 27 (HSP27) plays an important, protective role against noxious factors in the cardiovascular (CV) system. This study is aimed at assessing whether low HSP27 is associated with myocardial inhomogeneities in HD patients, as expressed by increases in the spatial QRS-T angle. Methods. Clinical data and biochemical, echocardiographic, and electrocardiographic parameters were evaluated in 182 HD patients. Patients were split into normal and abnormal QRS-T angle groups. Results. Patients with abnormally high QRS-T angles were older and had higher prevalence of diabetes as well as myocardial infarction, higher left ventricular mass index (LVMI) and C-reactive protein, worse oxidant/antioxidant status, and lower ejection fraction and HSP27. Multiple regression analysis revealed that abnormal QRS-T values were independently, negatively associated with serum HSP27 and positively associated with LVMI. Conclusions. Low HSP27 levels are associated with increased heterogeneity of myocardial action potential, as expressed by increased spatial QRS-T angle.
- Open Access
- 11 April 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (4) , e61076
New System for Digital to Analog Transformation and Reconstruction of 12-Lead ECGs
We describe initial validation of a new system for digital to analog conversion (DAC) and reconstruction of 12-lead ECGs. The system utilizes an open and optimized software format with a commensurately optimized DAC hardware configuration to accurately reproduce, from digital files, the original analog electrocardiographic signals of previously instrumented patients. By doing so, the system also ultimately allows for transmission of data collected on one manufacturer's 12-lead ECG hardware/software into that of any other. To initially validate the system, we compared original and post-DAC re-digitized 12-lead ECG data files (∼5-minutes long) in two types of validation studies in 10 patients. The first type quantitatively compared the total waveform voltage differences between the original and re-digitized data while the second type qualitatively compared the automated electrocardiographic diagnostic statements generated by the original versus re-digitized data. The grand-averaged difference in root mean squared voltage between the original and re-digitized data was 20.8 µV per channel when re-digitization involved the same manufacturer's analog to digital converter (ADC) as the original digitization, and 28.4 µV per channel when it involved a different manufacturer's ADC. Automated diagnostic statements generated by the original versus reconstructed data did not differ when using the diagnostic algorithm from the same manufacturer on whose device the original data were collected, and differed only slightly for just 1 of 10 patients when using a third-party diagnostic algorithm throughout. Original analog 12-lead ECG signals can be reconstructed from digital data files with accuracy sufficient for clinical use. Such reconstructions can readily enable automated second opinions for difficult-to-interpret 12-lead ECGs, either locally or remotely through the use of dedicated or cloud-based servers.
- 11 April 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (4) , e61076
Open AccessNew System for Digital to Analog Transformation and Reconstruction of 12-Lead ECGs
We describe initial validation of a new system for digital to analog conversion (DAC) and reconstruction of 12-lead ECGs. The system utilizes an open and optimized software format with a commensurately optimized DAC hardware configuration to accurately reproduce, from digital files, the original analog electrocardiographic signals of previously instrumented patients. By doing so, the system also ultimately allows for transmission of data collected on one manufacturer's 12-lead ECG hardware/software into that of any other. To initially validate the system, we compared original and post-DAC re-digitized 12-lead ECG data files (∼5-minutes long) in two types of validation studies in 10 patients. The first type quantitatively compared the total waveform voltage differences between the original and re-digitized data while the second type qualitatively compared the automated electrocardiographic diagnostic statements generated by the original versus re-digitized data. The grand-averaged difference in root mean squared voltage between the original and re-digitized data was 20.8 µV per channel when re-digitization involved the same manufacturer's analog to digital converter (ADC) as the original digitization, and 28.4 µV per channel when it involved a different manufacturer's ADC. Automated diagnostic statements generated by the original versus reconstructed data did not differ when using the diagnostic algorithm from the same manufacturer on whose device the original data were collected, and differed only slightly for just 1 of 10 patients when using a third-party diagnostic algorithm throughout. Original analog 12-lead ECG signals can be reconstructed from digital data files with accuracy sufficient for clinical use. Such reconstructions can readily enable automated second opinions for difficult-to-interpret 12-lead ECGs, either locally or remotely through the use of dedicated or cloud-based servers.
- 1 November 2010
- Published by Elsevier in Journal of Electrocardiology
- Vol. 43 (6) , 713-718
Detection of hypertrophic cardiomyopathy is improved when using advanced rather than strictly conventional 12-lead electrocardiogram
- 1 November 2010
- Published by Elsevier in Journal of Electrocardiology
- Vol. 43 (6) , 713-718
Detection of hypertrophic cardiomyopathy is improved when using advanced rather than strictly conventional 12-lead electrocardiogram
- Open Access
- 16 June 2010
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 10 (1) , 28
Accuracy of advanced versus strictly conventional 12-lead ECG for detection and screening of coronary artery disease, left ventricular hypertrophy and left ventricular systolic dysfunction
Resting conventional 12-lead ECG has low sensitivity for detection of coronary artery disease (CAD) and left ventricular hypertrophy (LVH) and low positive predictive value (PPV) for prediction of left ventricular systolic dysfunction (LVSD). We hypothesized that a ~5-min resting 12-lead advanced ECG test ("A-ECG") that combined results from both the advanced and conventional ECG could more accurately screen for these conditions than strictly conventional ECG.
- 16 June 2010
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 10 (1) , 28
Open AccessAccuracy of advanced versus strictly conventional 12-lead ECG for detection and screening of coronary artery disease, left ventricular hypertrophy and left ventricular systolic dysfunction
Resting conventional 12-lead ECG has low sensitivity for detection of coronary artery disease (CAD) and left ventricular hypertrophy (LVH) and low positive predictive value (PPV) for prediction of left ventricular systolic dysfunction (LVSD). We hypothesized that a ~5-min resting 12-lead advanced ECG test ("A-ECG") that combined results from both the advanced and conventional ECG could more accurately screen for these conditions than strictly conventional ECG.
- Open Access
- 23 September 2009
- Published by Springer Nature in BMC Neuroscience
- Vol. 10 (1) , 119
Vestibular effects on cerebral blood flow
Humans demonstrate a number of unique adaptations that allow for the maintenance of blood pressure and brain blood flow when upright. While several physiological systems, including cerebral autoregulation, are involved in this adaptation the unique role the vestibular system plays in helping to maintain brain blood flow is just beginning to be elucidated. In this study, we tested the hypothesis that stimulation of the vestibular system, specifically the otoliths organs, would result in changes in cerebral blood flow.
- 23 September 2009
- Published by Springer Nature in BMC Neuroscience
- Vol. 10 (1) , 119
Open AccessVestibular effects on cerebral blood flow
Humans demonstrate a number of unique adaptations that allow for the maintenance of blood pressure and brain blood flow when upright. While several physiological systems, including cerebral autoregulation, are involved in this adaptation the unique role the vestibular system plays in helping to maintain brain blood flow is just beginning to be elucidated. In this study, we tested the hypothesis that stimulation of the vestibular system, specifically the otoliths organs, would result in changes in cerebral blood flow.
- 1 July 2006
- Published by Elsevier in Journal of Electrocardiology
- Vol. 39 (3) , 259-265
Temporal and postural variation of 12-lead high-frequency QRS electrocardiographic signals in asymptomatic individuals
- 1 July 2006
- Published by Elsevier in Journal of Electrocardiology
- Vol. 39 (3) , 259-265
Temporal and postural variation of 12-lead high-frequency QRS electrocardiographic signals in asymptomatic individuals
- 1 March 2004
- Published by Elsevier in Mayo Clinic Proceedings
- Vol. 79 (3) , 339-350
Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease
- 1 March 2004
- Published by Elsevier in Mayo Clinic Proceedings
- Vol. 79 (3) , 339-350
Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease