Hong-Chang Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hong-Chang Yang has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
H. E. Horng
Institute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei, Taiwan
11 shared publications- Jen-Jie Chieh
Institute of Electro-Optical Engineering, National Taiwan Normal University, Taipei 116, Taiwan
10 shared publications - Li Min Wang
National Taiwan University
9 shared publications - S. Y. Yang
Institute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei, Taiwan
8 shared publications - Shu-Hsien Liao
Institute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei, Taiwan
8 shared publications Herng-Er Horng
Institute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan
7 shared publications
Latest Publications
- 1 January 2017
- Published by Cleveland Clinic Journal of Medicine in Cleveland Clinic Journal of Medicine
- Vol. 84 (3) , 184-185
Porcelain heart in a uremic patient
- 1 January 2017
- Published by Cleveland Clinic Journal of Medicine in Cleveland Clinic Journal of Medicine
- Vol. 84 (3) , 184-185
Porcelain heart in a uremic patient
- 1 April 2015
- Published by Elsevier in Journal of Hepatology
- Vol. 62, S563
P0648 : Long-term outcome of chemotherapy-induced HBV reactivation in lymphoma patients with resolved HBV infection
- 1 April 2015
- Published by Elsevier in Journal of Hepatology
- Vol. 62, S563
P0648 : Long-term outcome of chemotherapy-induced HBV reactivation in lymphoma patients with resolved HBV infection
- Open Access
Using Bio-Functionalized Magnetic Nanoparticles and Dynamic Nuclear Magnetic Resonance to Characterize the Time-Dependent Spin-Spin Relaxation Time for Sensitive Bio-Detection
In this work, we report the use of bio-functionalized magnetic nanoparticles (BMNs) and dynamic magnetic resonance (DMR) to characterize the time-dependent spin-spin relaxation time for sensitive bio-detection. The biomarkers are the human C-reactive protein (CRP) while the BMNs are the anti-CRP bound onto dextran-coated Fe3O4 particles labeled as Fe3O4-antiCRP. It was found the time-dependent spin-spin relaxation time, T2, of protons decreases as time evolves. Additionally, the ΔT2 of of protons in BMNs increases as the concentration of CRP increases. We attribute these to the formation of the magnetic clusters that deteriorate the field homogeneity of nearby protons. A sensitivity better than 0.1 μg/mL for assaying CRP is achieved, which is much higher than that required by the clinical criteria (0.5 mg/dL). The present MR-detection platform shows promise for further use in detecting tumors, viruses, and proteins.
Open AccessUsing Bio-Functionalized Magnetic Nanoparticles and Dynamic Nuclear Magnetic Resonance to Characterize the Time-Dependent Spin-Spin Relaxation Time for Sensitive Bio-Detection
In this work, we report the use of bio-functionalized magnetic nanoparticles (BMNs) and dynamic magnetic resonance (DMR) to characterize the time-dependent spin-spin relaxation time for sensitive bio-detection. The biomarkers are the human C-reactive protein (CRP) while the BMNs are the anti-CRP bound onto dextran-coated Fe3O4 particles labeled as Fe3O4-antiCRP. It was found the time-dependent spin-spin relaxation time, T2, of protons decreases as time evolves. Additionally, the ΔT2 of of protons in BMNs increases as the concentration of CRP increases. We attribute these to the formation of the magnetic clusters that deteriorate the field homogeneity of nearby protons. A sensitivity better than 0.1 μg/mL for assaying CRP is achieved, which is much higher than that required by the clinical criteria (0.5 mg/dL). The present MR-detection platform shows promise for further use in detecting tumors, viruses, and proteins.
- 1 April 2014
- Published by Elsevier in Journal of Hepatology
- Vol. 60 (1) , S206-S207
P415 PREVENTION OF CHEMOTHERAPY-INDUCED HBV-RELATED HEPATITIS FLARE IN LYMPHOMA PATIENTS WITH RESOLVED HBV INFECTION: COST ANALYSIS
- 1 April 2014
- Published by Elsevier in Journal of Hepatology
- Vol. 60 (1) , S206-S207
P415 PREVENTION OF CHEMOTHERAPY-INDUCED HBV-RELATED HEPATITIS FLARE IN LYMPHOMA PATIENTS WITH RESOLVED HBV INFECTION: COST ANALYSIS
- Open Access
- 8 October 2013
- Published by Springer Nature in Discover Nano
- Vol. 8 (1) , 413
Anti-CEA-functionalized superparamagnetic iron oxide nanoparticles for examining colorectal tumors in vivo
Although the biomarker carcinoembryonic antigen (CEA) is expressed in colorectal tumors, the utility of an anti-CEA-functionalized image medium is powerful for in vivo positioning of colorectal tumors. With a risk of superparamagnetic iron oxide nanoparticles (SPIONPs) that is lower for animals than other material carriers, anti-CEA-functionalized SPIONPs were synthesized in this study for labeling colorectal tumors by conducting different preoperatively and intraoperatively in vivo examinations. In magnetic resonance imaging (MRI), the image variation of colorectal tumors reached the maximum at approximately 24 h. However, because MRI requires a nonmetal environment, it was limited to preoperative imaging. With the potentiality of in vivo screening and intraoperative positioning during surgery, the scanning superconducting-quantum-interference-device biosusceptometry (SSB) was adopted, showing the favorable agreement of time-varied intensity with MRI. Furthermore, biological methodologies of different tissue staining methods and inductively coupled plasma (ICP) yielded consistent results, proving that the obtained in vivo results occurred because of targeted anti-CEA SPIONPs. This indicates that developed anti-CEA SPIONPs owe the utilities as an image medium of these in vivo methodologies.
- 8 October 2013
- Published by Springer Nature in Discover Nano
- Vol. 8 (1) , 413
Open AccessAnti-CEA-functionalized superparamagnetic iron oxide nanoparticles for examining colorectal tumors in vivo
Although the biomarker carcinoembryonic antigen (CEA) is expressed in colorectal tumors, the utility of an anti-CEA-functionalized image medium is powerful for in vivo positioning of colorectal tumors. With a risk of superparamagnetic iron oxide nanoparticles (SPIONPs) that is lower for animals than other material carriers, anti-CEA-functionalized SPIONPs were synthesized in this study for labeling colorectal tumors by conducting different preoperatively and intraoperatively in vivo examinations. In magnetic resonance imaging (MRI), the image variation of colorectal tumors reached the maximum at approximately 24 h. However, because MRI requires a nonmetal environment, it was limited to preoperative imaging. With the potentiality of in vivo screening and intraoperative positioning during surgery, the scanning superconducting-quantum-interference-device biosusceptometry (SSB) was adopted, showing the favorable agreement of time-varied intensity with MRI. Furthermore, biological methodologies of different tissue staining methods and inductively coupled plasma (ICP) yielded consistent results, proving that the obtained in vivo results occurred because of targeted anti-CEA SPIONPs. This indicates that developed anti-CEA SPIONPs owe the utilities as an image medium of these in vivo methodologies.
- 7 October 2013
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 26 (11) , 115008
A signal input coil made of superconducting thin film for improved signal-to-noise ratio in a high-TcSQUID-based ultra-low field nuclear magnetic resonance system
Resonant coupling schemes are commonly used in SQUID-based ultra-low field (ULF) nuclear magnetic resonance (NMR) systems to couple the spin relaxation signals from samples to the SQUID. Generally, in NMR systems, a resonant coupling scheme is composed of two solenoid coils which are made of enamel insulated wires and a capacitor connected in series. In this work, we tried to replace the metal solenoid input coil with a planar high-Tc superconducting spiral coil to improve the signal-to-noise ratio (SNR) of the ULF NMR signal. A measurement of the free induction decay signal of water protons was performed to demonstrate the improved performance of the system. This improvement is due to the fact that the planar superconducting spiral coil possesses a higher mutual inductance with the SQUID. Therefore, it is a promising way to enhance the SNR of high-Tc SQUID-based ULF NMR/MRI systems.
- 7 October 2013
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 26 (11) , 115008
A signal input coil made of superconducting thin film for improved signal-to-noise ratio in a high-TcSQUID-based ultra-low field nuclear magnetic resonance system
Resonant coupling schemes are commonly used in SQUID-based ultra-low field (ULF) nuclear magnetic resonance (NMR) systems to couple the spin relaxation signals from samples to the SQUID. Generally, in NMR systems, a resonant coupling scheme is composed of two solenoid coils which are made of enamel insulated wires and a capacitor connected in series. In this work, we tried to replace the metal solenoid input coil with a planar high-Tc superconducting spiral coil to improve the signal-to-noise ratio (SNR) of the ULF NMR signal. A measurement of the free induction decay signal of water protons was performed to demonstrate the improved performance of the system. This improvement is due to the fact that the planar superconducting spiral coil possesses a higher mutual inductance with the SQUID. Therefore, it is a promising way to enhance the SNR of high-Tc SQUID-based ULF NMR/MRI systems.
- 4 September 2013
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 25 (39) , 395702
Longitudinal and transverse Hall resistivities in NaFe1−xCoxAs single crystals withx= 0.022 and 0.0205: weak pinning and anomalous electrical transport properties
The in-plane longitudinal and Hall resistivities, ρxx and ρxy, of superconducting NaFe1-xCoxAs (NFCA) single crystals with x = 0.022 and 0.0205 in the mixed state and the normal state were measured to study the electrical transport properties in nearly optimum-doping iron-based superconductors. The resistivities under magnetic fields show thermally activated behavior and a power law magnetic field dependence of activation energy has been obtained. Due to the weak flux pinning, there is no sign reversal of Hall resistivities observed for NFCA with either x = 0.022 or 0.0205. The correlation between longitudinal and Hall resistivities shows that the scaling behavior of |ρxy| ∝ (ρxx)(β) with the exponent β ≈ 2.0 is in agreement with theoretical predictions for weak-pinning superconductors. Anisotropic upper critical fields and coherence lengths with an anisotropy ratio of γ ≈ 1.63 have been deduced. Furthermore, the normal-state transport properties show that the anomalies of the linear-T resistivity, the T(2)-dependent cotangent of the Hall angle, the linear-T-like Hall number, and the magnetoresistance, which can be scaled by the modified Kohler rule, are analogous to those observed on optimally doped high-Tc superconducting cuprates and other pnictides. The longitudinal resistivity can be understood within a widely accepted scenario of the spin density-wave quantum critical point, while the transverse resistivity requires some further explanation. It is suggested that all the transport anomalies should be simultaneously taken into account when developing theory.
- 4 September 2013
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 25 (39) , 395702
Longitudinal and transverse Hall resistivities in NaFe1−xCoxAs single crystals withx= 0.022 and 0.0205: weak pinning and anomalous electrical transport properties
The in-plane longitudinal and Hall resistivities, ρxx and ρxy, of superconducting NaFe1-xCoxAs (NFCA) single crystals with x = 0.022 and 0.0205 in the mixed state and the normal state were measured to study the electrical transport properties in nearly optimum-doping iron-based superconductors. The resistivities under magnetic fields show thermally activated behavior and a power law magnetic field dependence of activation energy has been obtained. Due to the weak flux pinning, there is no sign reversal of Hall resistivities observed for NFCA with either x = 0.022 or 0.0205. The correlation between longitudinal and Hall resistivities shows that the scaling behavior of |ρxy| ∝ (ρxx)(β) with the exponent β ≈ 2.0 is in agreement with theoretical predictions for weak-pinning superconductors. Anisotropic upper critical fields and coherence lengths with an anisotropy ratio of γ ≈ 1.63 have been deduced. Furthermore, the normal-state transport properties show that the anomalies of the linear-T resistivity, the T(2)-dependent cotangent of the Hall angle, the linear-T-like Hall number, and the magnetoresistance, which can be scaled by the modified Kohler rule, are analogous to those observed on optimally doped high-Tc superconducting cuprates and other pnictides. The longitudinal resistivity can be understood within a widely accepted scenario of the spin density-wave quantum critical point, while the transverse resistivity requires some further explanation. It is suggested that all the transport anomalies should be simultaneously taken into account when developing theory.
- Open Access
- 18 April 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (4) , e61958
A Temperature-Stable Cryo-System for High-Temperature Superconducting MR In-Vivo Imaging
To perform a rat experiment using a high-temperature superconducting (HTS) surface resonator, a cryostat is essential to maintain the rat's temperature. In this work, a compact temperature-stable HTS cryo-system, keeping animal rectal temperature at 37.4°C for more than 3 hours, was successfully developed. With this HTS cryo-system, a 40-mm-diameter Bi2Sr2Ca2Cu3Ox (Bi-2223) surface resonator at 77 K was demonstrated in a 3-Tesla MRI system. The proton resonant frequency (PRF) method was employed to monitor the rat's temperature. Moreover, the capacity of MR thermometry in the HTS experiments was evaluated by correlating with data from independent fiber-optic sensor temperature measurements. The PRF thermal coefficient was derived as 0.03 rad/°C and the temperature-monitoring architecture can be implemented to upgrade the quality and safety in HTS experiments. The signal-to-noise ratio (SNR) of the HTS surface resonator at 77 K was higher than that of a professionally made copper surface resonator at 300 K, which has the same geometry, by a 3.79-fold SNR gain. Furthermore, the temperature-stable HTS cryo-system we developed can obtain stable SNR gain in every scan. A temperature-stable HTS cryo-system with an external air-blowing circulation system is demonstrated.
- 18 April 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (4) , e61958
Open AccessA Temperature-Stable Cryo-System for High-Temperature Superconducting MR In-Vivo Imaging
To perform a rat experiment using a high-temperature superconducting (HTS) surface resonator, a cryostat is essential to maintain the rat's temperature. In this work, a compact temperature-stable HTS cryo-system, keeping animal rectal temperature at 37.4°C for more than 3 hours, was successfully developed. With this HTS cryo-system, a 40-mm-diameter Bi2Sr2Ca2Cu3Ox (Bi-2223) surface resonator at 77 K was demonstrated in a 3-Tesla MRI system. The proton resonant frequency (PRF) method was employed to monitor the rat's temperature. Moreover, the capacity of MR thermometry in the HTS experiments was evaluated by correlating with data from independent fiber-optic sensor temperature measurements. The PRF thermal coefficient was derived as 0.03 rad/°C and the temperature-monitoring architecture can be implemented to upgrade the quality and safety in HTS experiments. The signal-to-noise ratio (SNR) of the HTS surface resonator at 77 K was higher than that of a professionally made copper surface resonator at 300 K, which has the same geometry, by a 3.79-fold SNR gain. Furthermore, the temperature-stable HTS cryo-system we developed can obtain stable SNR gain in every scan. A temperature-stable HTS cryo-system with an external air-blowing circulation system is demonstrated.
- 25 January 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 113 (4) , 043911
Relaxation of biofunctionalized magnetic nanoparticles in ultra-low magnetic fields
In this work, the spin-spin relaxation rate, 1/T2, and spin-lattice relaxation rate, 1/T1, of protons’ spins induced by biofunctionalized magnetic nanoparticles and ferrofluids are investigated using a high-Tc superconducting quantum interference device-detected magnetometer in ultra-low fields. The biofunctionalized magnetic nanoparticles are the anti-human C-reactive protein (antiCRP) coated onto dextran-coated superparamagnetic iron oxides Fe3O4, which is labeled as Fe3O4-antiCRP. The ferrofluids are dextran-coated iron oxides. It was found that both 1/T2 and 1/T1 of protons in Fe3O4-antiCRP are enhanced by the presence of magnetic nanoparticles. Additionally, both the 1/T1 and 1/T2 of Fe3O4-antiCRP are close to that of ferrofluids, which are dextran-coated Fe3O4 dispersed in phosphate buffer saline. Characterizing the relaxation of Fe3O4-antiCRP can be useful for biomedical applications.
- 25 January 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 113 (4) , 043911
Relaxation of biofunctionalized magnetic nanoparticles in ultra-low magnetic fields
In this work, the spin-spin relaxation rate, 1/T2, and spin-lattice relaxation rate, 1/T1, of protons’ spins induced by biofunctionalized magnetic nanoparticles and ferrofluids are investigated using a high-Tc superconducting quantum interference device-detected magnetometer in ultra-low fields. The biofunctionalized magnetic nanoparticles are the anti-human C-reactive protein (antiCRP) coated onto dextran-coated superparamagnetic iron oxides Fe3O4, which is labeled as Fe3O4-antiCRP. The ferrofluids are dextran-coated iron oxides. It was found that both 1/T2 and 1/T1 of protons in Fe3O4-antiCRP are enhanced by the presence of magnetic nanoparticles. Additionally, both the 1/T1 and 1/T2 of Fe3O4-antiCRP are close to that of ferrofluids, which are dextran-coated Fe3O4 dispersed in phosphate buffer saline. Characterizing the relaxation of Fe3O4-antiCRP can be useful for biomedical applications.