Ghalem Bachir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ghalem Bachir has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Michel Aillerie
Affiliation Laboratoire Matériaux Optiques, Photonique et Systèmes (LMOPS), Université de Lorraine & CentraleSupélec, Metz, France
8 shared publications - Zine Eddine Touhami Ternifi
University of Sciences and Technology of Oran, Faculty of electrical engineering, Department of electrical engineering, Laboratory of sustainable development of the electrical energy (LDDEE), Bir El Djir 1505, El-Mnaouer, 31000 Oran, Algeria
4 shared publications P. Petit
Université de Lorraine, LMOPS, EA 4423, 57070 Metz, France
3 shared publicationsA. Bendiabdellah
2 shared publicationsB. Hadri
2 shared publicationsF. Djaafar
2 shared publications
Latest Publications
- Open Access
- 16 March 2026
- Published by Czech Technical University in Prague - Central Library in Acta Polytechnica
- Vol. 66 (1) , 30-35
Design and stability analysis of a high-performance three-phase inverter for photovoltaic applications
This paper presents the design and analysis of a three-phase photovoltaic inverter based on a Boost-Buck-Discharge microinverter architecture. It converts low DC voltages (24–240 V), typical of PV panels, into high-quality three-phase AC with minimal THD. The topology integrates a boost converter elevating voltage to 240 V, a buck-discharge stage generating rectified sinusoidal waveforms, and a full-bridge inverter producing pure sinusoidal outputs. A step-up transformer ensures standardised voltages of 225 V RMS (single-phase) and 390 V RMS (line-to-line) with galvanic isolation. Sliding mode control is applied to buck-discharge circuits to ensure robust and stable operation, validated via Lyapunov analysis. Results show THD below 3 % for all tested resistive and inductive loads, confirming efficient multilevel conversion and suitability for decentralised renewable energy systems requiring reliable three-phase DC-AC transformation.
- 16 March 2026
- Published by Czech Technical University in Prague - Central Library in Acta Polytechnica
- Vol. 66 (1) , 30-35
Open AccessDesign and stability analysis of a high-performance three-phase inverter for photovoltaic applications
This paper presents the design and analysis of a three-phase photovoltaic inverter based on a Boost-Buck-Discharge microinverter architecture. It converts low DC voltages (24–240 V), typical of PV panels, into high-quality three-phase AC with minimal THD. The topology integrates a boost converter elevating voltage to 240 V, a buck-discharge stage generating rectified sinusoidal waveforms, and a full-bridge inverter producing pure sinusoidal outputs. A step-up transformer ensures standardised voltages of 225 V RMS (single-phase) and 390 V RMS (line-to-line) with galvanic isolation. Sliding mode control is applied to buck-discharge circuits to ensure robust and stable operation, validated via Lyapunov analysis. Results show THD below 3 % for all tested resistive and inductive loads, confirming efficient multilevel conversion and suitability for decentralised renewable energy systems requiring reliable three-phase DC-AC transformation.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 15 (6) , 832-839
New Model for Estimating the Temperature and Solar Irradiance of Photovoltaic Panels Based on Maximum Power Point Tracking Measurements
This article proposes a new method for estimating the temperature and irradiance of a photovoltaic module using current and voltage measurements within a maximum power point tracking (MPPT) control system. Unlike traditional methods that depend on external data, such as those provided by complex irradiance and wind speed sensors and equipment, this approach relies solely on panel-specific I–V measurements needed for MPPT, enabling accurate estimations through a simpler and real-time method. A comparative evaluation of various panel temperature estimation techniques confirms that the proposed method outperforms existing ones, resulting in mean absolute estimation errors below 1 °C for temperature and 4 W/m2 for irradiance. The method effectively addresses temperature variations, particularly under low irradiance conditions, where the proportional relationship between current and irradiance becomes less reliable. Results indicate that incorporating the estimated panel temperature significantly enhances irradiance predictions, especially in real-world operating conditions. Furthermore, the method remains valid even as the panel ages, making it a valuable tool for optimizing photovoltaic system performance. Given its simplicity and its low cost, this technique is well suited for real-time monitoring and optimization of solar energy installations.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 15 (6) , 832-839
New Model for Estimating the Temperature and Solar Irradiance of Photovoltaic Panels Based on Maximum Power Point Tracking Measurements
This article proposes a new method for estimating the temperature and irradiance of a photovoltaic module using current and voltage measurements within a maximum power point tracking (MPPT) control system. Unlike traditional methods that depend on external data, such as those provided by complex irradiance and wind speed sensors and equipment, this approach relies solely on panel-specific I–V measurements needed for MPPT, enabling accurate estimations through a simpler and real-time method. A comparative evaluation of various panel temperature estimation techniques confirms that the proposed method outperforms existing ones, resulting in mean absolute estimation errors below 1 °C for temperature and 4 W/m2 for irradiance. The method effectively addresses temperature variations, particularly under low irradiance conditions, where the proportional relationship between current and irradiance becomes less reliable. Results indicate that incorporating the estimated panel temperature significantly enhances irradiance predictions, especially in real-world operating conditions. Furthermore, the method remains valid even as the panel ages, making it a valuable tool for optimizing photovoltaic system performance. Given its simplicity and its low cost, this technique is well suited for real-time monitoring and optimization of solar energy installations.
- Open Access
- 2 May 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 3,p. 18-22
Comparative analysis between classical and third-order sliding mode controllers for maximum power extraction in wind turbine system
Introduction. Maximizing power extraction in wind energy conversion systems is crucial for efficiency but remains a challenge due to rapid wind speed variations and the high inertia of the generator. Conventional controllers, such as the PI controller, struggle to maintain optimal performance under such dynamic conditions, leading to suboptimal power capture and increased system oscillations. The goal of this study is to enhance the efficiency of wind turbine systems by applying linear and nonlinear controllers in a maximum power point tracking (MPPT) strategy. This approach focuses on improving generator speed regulation and power conversion performance. Methods. A comparative analysis is conducted using three different control strategies: third-order sliding mode control (TO-SMC), classical sliding mode control (SMC) and PI control. These controllers are implemented in the generator speed loop of a wind turbine system, and their performance is evaluated through MATLAB/Simulink simulations. The assessment focuses on key performance metrics such as tracking accuracy, total harmonic distortion (THD), response time, and system stability. Results. The simulation results confirm that all controllers achieve MPPT, but with varying levels of effectiveness. The TO-SMC outperforms both SMC and PI controllers, offering higher efficiency, reduced chattering, better disturbance rejection, and lower THD (reduced from 73 % in SMC to 68.09 %). Additionally, TO-SMC significantly improves dynamic response, reducing overshoot and enhancing system stability. Originality. This study introduces a TO-SMC for MPPT in wind turbine systems, demonstrating its superiority over conventional control techniques. The findings highlight its ability to maintain optimal power extraction even under rapid wind variations, making it a promising solution for advanced wind energy systems. Practical value. By improving power quality, reducing system oscillations, and enhancing overall wind turbine efficiency, the proposed TO-SMC contributes to the reliable integration of wind energy into power grids. These advancements can benefit renewable energy operators, power system engineers, and researchers seeking efficient and robust MPPT solutions for wind turbines. References 13, figures 11.
- 2 May 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 3,p. 18-22
Open AccessComparative analysis between classical and third-order sliding mode controllers for maximum power extraction in wind turbine system
Introduction. Maximizing power extraction in wind energy conversion systems is crucial for efficiency but remains a challenge due to rapid wind speed variations and the high inertia of the generator. Conventional controllers, such as the PI controller, struggle to maintain optimal performance under such dynamic conditions, leading to suboptimal power capture and increased system oscillations. The goal of this study is to enhance the efficiency of wind turbine systems by applying linear and nonlinear controllers in a maximum power point tracking (MPPT) strategy. This approach focuses on improving generator speed regulation and power conversion performance. Methods. A comparative analysis is conducted using three different control strategies: third-order sliding mode control (TO-SMC), classical sliding mode control (SMC) and PI control. These controllers are implemented in the generator speed loop of a wind turbine system, and their performance is evaluated through MATLAB/Simulink simulations. The assessment focuses on key performance metrics such as tracking accuracy, total harmonic distortion (THD), response time, and system stability. Results. The simulation results confirm that all controllers achieve MPPT, but with varying levels of effectiveness. The TO-SMC outperforms both SMC and PI controllers, offering higher efficiency, reduced chattering, better disturbance rejection, and lower THD (reduced from 73 % in SMC to 68.09 %). Additionally, TO-SMC significantly improves dynamic response, reducing overshoot and enhancing system stability. Originality. This study introduces a TO-SMC for MPPT in wind turbine systems, demonstrating its superiority over conventional control techniques. The findings highlight its ability to maintain optimal power extraction even under rapid wind variations, making it a promising solution for advanced wind energy systems. Practical value. By improving power quality, reducing system oscillations, and enhancing overall wind turbine efficiency, the proposed TO-SMC contributes to the reliable integration of wind energy into power grids. These advancements can benefit renewable energy operators, power system engineers, and researchers seeking efficient and robust MPPT solutions for wind turbines. References 13, figures 11.
- Open Access
- 20 June 2024
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Electrical Engineering and Computer Science
- Vol. 68 (3) , 240-245
Photovoltaic Microinverter Based on Buck-Boost Converter and Discharge Circuit
This paper presents a novel topology for photovoltaic microinverters that uses a buck-boost converter coupled with a discharge circuit. The system enables efficient conversion of electrical energy from the solar panel without requiring voltage filters or step-up transformers. For its control, an exponential action control strategy is used, as it allows effective tracking of the reference voltage. The stability of the overall control and inverter system is demonstrated and detailed using the Lyapunov method. The sizing of the components used is also detailed. The performance of this topology is evaluated under various load conditions, revealing low harmonic distortion (THD) in both current and voltage, with the best THD of 1% being obtained at a power factor of 0.8. This makes it a promising solution for photovoltaic energy conversion.
- 20 June 2024
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Electrical Engineering and Computer Science
- Vol. 68 (3) , 240-245
Open AccessPhotovoltaic Microinverter Based on Buck-Boost Converter and Discharge Circuit
This paper presents a novel topology for photovoltaic microinverters that uses a buck-boost converter coupled with a discharge circuit. The system enables efficient conversion of electrical energy from the solar panel without requiring voltage filters or step-up transformers. For its control, an exponential action control strategy is used, as it allows effective tracking of the reference voltage. The stability of the overall control and inverter system is demonstrated and detailed using the Lyapunov method. The sizing of the components used is also detailed. The performance of this topology is evaluated under various load conditions, revealing low harmonic distortion (THD) in both current and voltage, with the best THD of 1% being obtained at a power factor of 0.8. This makes it a promising solution for photovoltaic energy conversion.
- Open Access
- 22 May 2024
- Published by Oxford University Press (OUP) in Clean Energy
- Vol. 8 (4) , 135-146
Tracking the maximum power point of solar panels through direct estimation of optimum voltage with temperature
Electricity production from photovoltaic (PV) panels is maximized when the operating point is located at the maximum power point thanks to dedicated controllers. These controllers are driven to track the maximum power by using various algorithms within distributed or centralized architectures accounting for factors such as partial irradiation and temperature changes. The effect of irradiance on the optimal panel voltage is weak or even negligible, while it is strong and quasi-linear-dependent on temperature. Based on this observation, this article introduces a straightforward method for tracking the maximum power of a PV panel by using an optimizer, focusing solely on its temperature response as an input variable. The proposed approach hinges on linearizing the relationship between panel temperature and operating voltage. This relationship enables the estimation of the maximum power point through temperature measurement alone. Thus, after determination of the linear temperature coefficient of the voltage requiring only the knowledge of two optimal voltages at different temperatures, for example from the datasheet of the panel, the power tracking involves only one temperature sensor placed on the panel alongside a voltage sensor for regulation. The principle, modelling, and validation post-panel ageing of the method are detailed in this paper. Simulation, conducted using real experimental irradiation and temperature data, attests to the effectiveness of the control. Results indicate an average effectiveness of the method of >99.1% in tracking the maximum power, with the panel generating 2.33 kWh out of a possible 2.35 kWh. This performance is comparable to that of tracking devices employing more complex algorithms. The simplicity and efficiency of the method make it a promising option for maximizing the power production at low cost from PV systems in small or residential, on- or off-grid connected applications.
- 22 May 2024
- Published by Oxford University Press (OUP) in Clean Energy
- Vol. 8 (4) , 135-146
Open AccessTracking the maximum power point of solar panels through direct estimation of optimum voltage with temperature
Electricity production from photovoltaic (PV) panels is maximized when the operating point is located at the maximum power point thanks to dedicated controllers. These controllers are driven to track the maximum power by using various algorithms within distributed or centralized architectures accounting for factors such as partial irradiation and temperature changes. The effect of irradiance on the optimal panel voltage is weak or even negligible, while it is strong and quasi-linear-dependent on temperature. Based on this observation, this article introduces a straightforward method for tracking the maximum power of a PV panel by using an optimizer, focusing solely on its temperature response as an input variable. The proposed approach hinges on linearizing the relationship between panel temperature and operating voltage. This relationship enables the estimation of the maximum power point through temperature measurement alone. Thus, after determination of the linear temperature coefficient of the voltage requiring only the knowledge of two optimal voltages at different temperatures, for example from the datasheet of the panel, the power tracking involves only one temperature sensor placed on the panel alongside a voltage sensor for regulation. The principle, modelling, and validation post-panel ageing of the method are detailed in this paper. Simulation, conducted using real experimental irradiation and temperature data, attests to the effectiveness of the control. Results indicate an average effectiveness of the method of >99.1% in tracking the maximum power, with the panel generating 2.33 kWh out of a possible 2.35 kWh. This performance is comparable to that of tracking devices employing more complex algorithms. The simplicity and efficiency of the method make it a promising option for maximizing the power production at low cost from PV systems in small or residential, on- or off-grid connected applications.
- 24 November 2018
- Published by Springer Nature
- p. 329-338
Comparative Study of Maximum Power Point Tracking Algorithms for Thermoelectric Generator
- 24 November 2018
- Published by Springer Nature
- p. 329-338
Comparative Study of Maximum Power Point Tracking Algorithms for Thermoelectric Generator
- Open Access
- 1 January 2018
- Published by MedCrave Group Kft. in International Journal of Avian & Wildlife Biology
- Vol. 3 (4) , 1
Antibacterial activity of diethyl ether and chloroform extracts of seaweeds against Escherichia coli and Staphylococcus aureus
- 1 January 2018
- Published by MedCrave Group Kft. in International Journal of Avian & Wildlife Biology
- Vol. 3 (4) , 1
Open AccessAntibacterial activity of diethyl ether and chloroform extracts of seaweeds against Escherichia coli and Staphylococcus aureus
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1968 (1) , 030084
Modeling and sizing the coil in boost converters dedicated to photovoltaic sources
The coil is a very important element in a wide range of power electrical systems as such as those used in converter or inverter dedicated to extract and to adapt the value and the shape of the intensity and the voltage delivered by renewable energy sources. Thus, knowing its behavior in converters is paramount to obtain a maximum conversion efficiency and reliability. In this context, this paper presents a global study of a DC/DC boost converter dedicated to photovoltaic sources based on the modeling of the behavior of the coil or the inductance as a function of the switching frequency.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1968 (1) , 030084
Modeling and sizing the coil in boost converters dedicated to photovoltaic sources
The coil is a very important element in a wide range of power electrical systems as such as those used in converter or inverter dedicated to extract and to adapt the value and the shape of the intensity and the voltage delivered by renewable energy sources. Thus, knowing its behavior in converters is paramount to obtain a maximum conversion efficiency and reliability. In this context, this paper presents a global study of a DC/DC boost converter dedicated to photovoltaic sources based on the modeling of the behavior of the coil or the inductance as a function of the switching frequency.
- 1 November 2017
- Published by Pleiades Publishing Ltd in Russian Journal of Marine Biology
- Vol. 43 (6) , 491-495
The Phenolic Contents and Antimicrobial Activities of Some Marine Algae from the Mediterranean Sea (Algeria)
In this study, three marine algae collected from western coast of algerian mediteranean sea ( Ulva lactuca, Dictyota dichotoma, and Corallina elongata) were tested using the agar-well diffusion...
- 1 November 2017
- Published by Pleiades Publishing Ltd in Russian Journal of Marine Biology
- Vol. 43 (6) , 491-495
The Phenolic Contents and Antimicrobial Activities of Some Marine Algae from the Mediterranean Sea (Algeria)
In this study, three marine algae collected from western coast of algerian mediteranean sea ( Ulva lactuca, Dictyota dichotoma, and Corallina elongata) were tested using the agar-well diffusion...
- Open Access
- 12 September 2017
- Published by Science Publishing Group in Advances in Biochemistry
- Vol. 5 (5) , 97-101
Antioxidant and Antimicrobial Activities of Exopolysaccharides from Yoghurt Starter
The in vitro antimicrobial and antioxidant activities of the exopolysaccharide (EPS) extracted from yoghurt starter were investigated. Antimicrobial activity tests were carried out using disc diffusion methods with Escherichia coli, Staphylococcus aureus and Streptococcus D, Proteus spp and the yeast of Candida albicans . The antioxidant properties were evaluated using the test of DPPH free radical trapping. The results show that the EPS has weak antimicrobial activity against the tested strains with inhibitions zones ranging from 9 to 13 mm. EPS could reduce the free radical (DPPH) to diphenylpicrylhydrazine a yellow-colored at 24.25% showing antioxidant activity less than that of ascorbic acid which was 69.79%.
- 12 September 2017
- Published by Science Publishing Group in Advances in Biochemistry
- Vol. 5 (5) , 97-101
Open AccessAntioxidant and Antimicrobial Activities of Exopolysaccharides from Yoghurt Starter
The in vitro antimicrobial and antioxidant activities of the exopolysaccharide (EPS) extracted from yoghurt starter were investigated. Antimicrobial activity tests were carried out using disc diffusion methods with Escherichia coli, Staphylococcus aureus and Streptococcus D, Proteus spp and the yeast of Candida albicans . The antioxidant properties were evaluated using the test of DPPH free radical trapping. The results show that the EPS has weak antimicrobial activity against the tested strains with inhibitions zones ranging from 9 to 13 mm. EPS could reduce the free radical (DPPH) to diphenylpicrylhydrazine a yellow-colored at 24.25% showing antioxidant activity less than that of ascorbic acid which was 69.79%.