Seth A. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seth A. Smith has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
Siddharama Pawate
Vanderbilt Univ, Med Ctr, Dept Neurol, Neuroimaging Unit,Neuroimmunol Div, Nashville, TN USA
7 shared publications- Alex K. Smith
Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
6 shared publications - Richard D. Dortch
Neuroimaging Innovation Center Barrow Neurological Institute Phoenix Arizona USA
6 shared publications Bailey A. Box
Vanderbilt Univ, Med Ctr, Inst Imaging Sci, Nashville, TN USA
5 shared publicationsBailey D. Lyttle
Vanderbilt Univ, Med Ctr, Inst Imaging Sci, Nashville, TN USA
5 shared publicationsSamantha By
Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
4 shared publications
Latest Publications
- Open Access
- 17 November 2023
- Published by Elsevier in NeuroImage
- Vol. 284, 120460
Cervical spinal cord susceptibility-weighted MRI at 7T: Application to multiple sclerosis
- 17 November 2023
- Published by Elsevier in NeuroImage
- Vol. 284, 120460
Open AccessCervical spinal cord susceptibility-weighted MRI at 7T: Application to multiple sclerosis
- 3 August 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 35 (6) , 1576-1589
Integrating the BIDS Neuroimaging Data Format and Workflow Optimization for Large-Scale Medical Image Analysis
A robust medical image computing infrastructure must host massive multimodal archives, perform extensive analysis pipelines, and execute scalable job management. An emerging data format standard, the Brain Imaging Data Structure (BIDS), introduces complexities for interfacing with XNAT archives. Moreover, workflow integration is combinatorically problematic when matching large amount of processing to large datasets. Historically, workflow engines have been focused on refining workflows themselves instead of actual job generation. However, such an approach is incompatible with data centric architecture that hosts heterogeneous medical image computing. Distributed automation for XNAT toolkit (DAX) provides large-scale image storage and analysis pipelines with an optimized job management tool. Herein, we describe developments for DAX that allows for integration of XNAT and BIDS standards. We also improve DAX’s efficiencies of diverse containerized workflows in a high-performance computing (HPC) environment. Briefly, we integrate YAML configuration processor scripts to abstract workflow data inputs, data outputs, commands, and job attributes. Finally, we propose an online database–driven mechanism for DAX to efficiently identify the most recent updated sessions, thereby improving job building efficiency on large projects. We refer the proposed overall DAX development in this work as DAX-1 (DAX version 1). To validate the effectiveness of the new features, we verified (1) the efficiency of converting XNAT data to BIDS format and the correctness of the conversion using a collection of BIDS standard containerized neuroimaging workflows, (2) how YAML-based processor simplified configuration setup via a sequence of application pipelines, and (3) the productivity of DAX-1 on generating actual HPC processing jobs compared with earlier DAX baseline method. The empirical results show that (1) DAX-1 converting XNAT data to BIDS has similar speed as accessing XNAT data only; (2) YAML can integrate to the DAX-1 with shallow learning curve for users, and (3) DAX-1 reduced the job/assessor generation latency by finding recent modified sessions. Herein, we present approaches for efficiently integrating XNAT and modern image formats with a scalable workflow engine for the large-scale dataset access and processing.
- 3 August 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 35 (6) , 1576-1589
Integrating the BIDS Neuroimaging Data Format and Workflow Optimization for Large-Scale Medical Image Analysis
A robust medical image computing infrastructure must host massive multimodal archives, perform extensive analysis pipelines, and execute scalable job management. An emerging data format standard, the Brain Imaging Data Structure (BIDS), introduces complexities for interfacing with XNAT archives. Moreover, workflow integration is combinatorically problematic when matching large amount of processing to large datasets. Historically, workflow engines have been focused on refining workflows themselves instead of actual job generation. However, such an approach is incompatible with data centric architecture that hosts heterogeneous medical image computing. Distributed automation for XNAT toolkit (DAX) provides large-scale image storage and analysis pipelines with an optimized job management tool. Herein, we describe developments for DAX that allows for integration of XNAT and BIDS standards. We also improve DAX’s efficiencies of diverse containerized workflows in a high-performance computing (HPC) environment. Briefly, we integrate YAML configuration processor scripts to abstract workflow data inputs, data outputs, commands, and job attributes. Finally, we propose an online database–driven mechanism for DAX to efficiently identify the most recent updated sessions, thereby improving job building efficiency on large projects. We refer the proposed overall DAX development in this work as DAX-1 (DAX version 1). To validate the effectiveness of the new features, we verified (1) the efficiency of converting XNAT data to BIDS format and the correctness of the conversion using a collection of BIDS standard containerized neuroimaging workflows, (2) how YAML-based processor simplified configuration setup via a sequence of application pipelines, and (3) the productivity of DAX-1 on generating actual HPC processing jobs compared with earlier DAX baseline method. The empirical results show that (1) DAX-1 converting XNAT data to BIDS has similar speed as accessing XNAT data only; (2) YAML can integrate to the DAX-1 with shallow learning curve for users, and (3) DAX-1 reduced the job/assessor generation latency by finding recent modified sessions. Herein, we present approaches for efficiently integrating XNAT and modern image formats with a scalable workflow engine for the large-scale dataset access and processing.
- 13 September 2019
- Published by Elsevier in NeuroImage
- Vol. 203, 116190
7T quantitative magnetization transfer (qMT) of cortical gray matter in multiple sclerosis correlates with cognitive impairment
- 13 September 2019
- Published by Elsevier in NeuroImage
- Vol. 203, 116190
7T quantitative magnetization transfer (qMT) of cortical gray matter in multiple sclerosis correlates with cognitive impairment
- Open Access
- 19 September 2018
- Published by SAGE Publications in Multiple Sclerosis Journal
- Vol. 25 (12) , 1580-1592
Glutamate-sensitive imaging and evaluation of cognitive impairment in multiple sclerosis
Background: Cognitive impairment (CI) profoundly impacts quality of life for patients with multiple sclerosis (MS). Dysfunctional regulation of glutamate in gray matter (GM) has been implicated in the pathogenesis of MS by post-mortem pathological studies and in CI by in vivo magnetic resonance spectroscopy, yet GM pathology is subtle and difficult to detect using conventional T1- and T2-weighted magnetic resonance imaging (MRI). There is a need for high-resolution, clinically accessible imaging techniques that probe molecular changes in GM. Objective: To study cortical GM pathology related to CI in MS using glutamate-sensitive chemical exchange saturation transfer (GluCEST) MRI at 7.0 Tesla (7T). Methods: A total of 20 patients with relapsing-remitting MS and 20 healthy controls underwent cognitive testing, anatomical imaging, and GluCEST imaging. Glutamate-sensitive image contrast was quantified for cortical GM, compared between cohorts, and correlated with clinical measures of CI. Results and Conclusion: Glutamate-sensitive contrast was significantly increased in the prefrontal cortex of MS patients with accumulated disability ( p < 0.05). In addition, glutamate-sensitive contrast in the prefrontal cortex was significantly correlated with symbol digit modality test ( rS = −0.814) and choice reaction time ( rS = 0.772) scores in patients ( p < 0.05), suggesting that GluCEST MRI may have utility as a marker for GM pathology and CI.
- 19 September 2018
- Published by SAGE Publications in Multiple Sclerosis Journal
- Vol. 25 (12) , 1580-1592
Open AccessGlutamate-sensitive imaging and evaluation of cognitive impairment in multiple sclerosis
Background: Cognitive impairment (CI) profoundly impacts quality of life for patients with multiple sclerosis (MS). Dysfunctional regulation of glutamate in gray matter (GM) has been implicated in the pathogenesis of MS by post-mortem pathological studies and in CI by in vivo magnetic resonance spectroscopy, yet GM pathology is subtle and difficult to detect using conventional T1- and T2-weighted magnetic resonance imaging (MRI). There is a need for high-resolution, clinically accessible imaging techniques that probe molecular changes in GM. Objective: To study cortical GM pathology related to CI in MS using glutamate-sensitive chemical exchange saturation transfer (GluCEST) MRI at 7.0 Tesla (7T). Methods: A total of 20 patients with relapsing-remitting MS and 20 healthy controls underwent cognitive testing, anatomical imaging, and GluCEST imaging. Glutamate-sensitive image contrast was quantified for cortical GM, compared between cohorts, and correlated with clinical measures of CI. Results and Conclusion: Glutamate-sensitive contrast was significantly increased in the prefrontal cortex of MS patients with accumulated disability ( p < 0.05). In addition, glutamate-sensitive contrast in the prefrontal cortex was significantly correlated with symbol digit modality test ( rS = −0.814) and choice reaction time ( rS = 0.772) scores in patients ( p < 0.05), suggesting that GluCEST MRI may have utility as a marker for GM pathology and CI.
- 1 February 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (4) , e3894
Multi‐compartmental diffusion characterization of the human cervical spinal cord in vivo using the spherical mean technique
The purpose of this work was to evaluate the feasibility and reproducibility of the spherical mean technique (SMT), a multi‐compartmental diffusion model, in the spinal cord of healthy controls, and to assess its ability to improve spinal cord characterization in multiple sclerosis (MS) patients at 3 T. SMT was applied in the cervical spinal cord of eight controls and six relapsing‐remitting MS patients. SMT provides an elegant framework to model the apparent axonal volume fraction vax, intrinsic diffusivity Dax, and extra‐axonal transverse diffusivity Dex_perp (which is estimated as a function of vax and Dax) without confounds related to complex fiber orientation distribution that reside in diffusion MRI modeling. SMT's reproducibility was assessed with two different scans within a month, and SMT‐derived indices in healthy and MS cohorts were compared. The influence of acquisition scheme on SMT was also evaluated. SMT's vax, Dax, and Dex_perp measurements all showed high reproducibility. A decrease in vax was observed at the site of lesions and normal appearing white matter (p < 0.05), and trends towards a decreased Dax and increased Dex_perp were seen. Importantly, a twofold reduction in acquisition yielded similarly high accuracy with SMT. SMT provides a fast, reproducible, and accurate method to improve characterization of the cervical spinal cord, and may have clinical potential for MS patients.
- 1 February 2018
- Published by Wiley in NMR in Biomedicine
- Vol. 31 (4) , e3894
Multi‐compartmental diffusion characterization of the human cervical spinal cord in vivo using the spherical mean technique
The purpose of this work was to evaluate the feasibility and reproducibility of the spherical mean technique (SMT), a multi‐compartmental diffusion model, in the spinal cord of healthy controls, and to assess its ability to improve spinal cord characterization in multiple sclerosis (MS) patients at 3 T. SMT was applied in the cervical spinal cord of eight controls and six relapsing‐remitting MS patients. SMT provides an elegant framework to model the apparent axonal volume fraction vax, intrinsic diffusivity Dax, and extra‐axonal transverse diffusivity Dex_perp (which is estimated as a function of vax and Dax) without confounds related to complex fiber orientation distribution that reside in diffusion MRI modeling. SMT's reproducibility was assessed with two different scans within a month, and SMT‐derived indices in healthy and MS cohorts were compared. The influence of acquisition scheme on SMT was also evaluated. SMT's vax, Dax, and Dex_perp measurements all showed high reproducibility. A decrease in vax was observed at the site of lesions and normal appearing white matter (p < 0.05), and trends towards a decreased Dax and increased Dex_perp were seen. Importantly, a twofold reduction in acquisition yielded similarly high accuracy with SMT. SMT provides a fast, reproducible, and accurate method to improve characterization of the cervical spinal cord, and may have clinical potential for MS patients.
- 5 May 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (2) , 806-814
Amide proton transfer CEST of the cervical spinal cord in multiple sclerosis patients at 3T
Purpose: The ability to evaluate pathological changes in the spinal cord in multiple sclerosis (MS) is limited because T1‐ and T2‐w MRI imaging are not sensitive to biochemical changes in vivo. Amide proton transfer (APT) chemical exchange saturation transfer (CEST) can indirectly detect amide protons associated with proteins and peptides, potentially providing more pathological specificity. Here, we implement APT CEST in the cervical spinal cord of healthy and MS cohorts at 3T.Methods: APT CEST of the cervical spinal cord was obtained in a cohort of 10 controls and 10 MS patients using a novel respiratory correction methodology. APT was quantified using two methods: 1) APTw, based off the conventional magnetization transfer ratio asymmetry, and 2) ΔAPT, a spatial characterization of APT changes in MS patients relative to the controls.Results: Respiratory correction yielded highly reproducible z‐spectra in white matter (intraclass correlation coefficient = 0.82). APTw signals in normal‐appearing white matter (NAWM) of MS patients were significantly different from healthy controls (P = 0.04), whereas ΔAPT of MS patients highlighted large APT differences in NAWM.Conclusion: Respiration correction in the spinal cord is necessary to accurately quantify APT CEST, which can provide unique biochemical information regarding disease processes within the spinal cord. Magn Reson Med 79:806–814, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- 5 May 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (2) , 806-814
Amide proton transfer CEST of the cervical spinal cord in multiple sclerosis patients at 3T
Purpose: The ability to evaluate pathological changes in the spinal cord in multiple sclerosis (MS) is limited because T1‐ and T2‐w MRI imaging are not sensitive to biochemical changes in vivo. Amide proton transfer (APT) chemical exchange saturation transfer (CEST) can indirectly detect amide protons associated with proteins and peptides, potentially providing more pathological specificity. Here, we implement APT CEST in the cervical spinal cord of healthy and MS cohorts at 3T.Methods: APT CEST of the cervical spinal cord was obtained in a cohort of 10 controls and 10 MS patients using a novel respiratory correction methodology. APT was quantified using two methods: 1) APTw, based off the conventional magnetization transfer ratio asymmetry, and 2) ΔAPT, a spatial characterization of APT changes in MS patients relative to the controls.Results: Respiratory correction yielded highly reproducible z‐spectra in white matter (intraclass correlation coefficient = 0.82). APTw signals in normal‐appearing white matter (NAWM) of MS patients were significantly different from healthy controls (P = 0.04), whereas ΔAPT of MS patients highlighted large APT differences in NAWM.Conclusion: Respiration correction in the spinal cord is necessary to accurately quantify APT CEST, which can provide unique biochemical information regarding disease processes within the spinal cord. Magn Reson Med 79:806–814, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- Open Access
- 1 January 2017
- Published by Elsevier in NeuroImage: Clinical
- Vol. 16, 58-65
Evaluating single-point quantitative magnetization transfer in the cervical spinal cord: Application to multiple sclerosis
- 1 January 2017
- Published by Elsevier in NeuroImage: Clinical
- Vol. 16, 58-65
Open AccessEvaluating single-point quantitative magnetization transfer in the cervical spinal cord: Application to multiple sclerosis
- Open Access
- 1 January 2017
- Published by Elsevier in NeuroImage: Clinical
- Vol. 15, 333-342
Application and evaluation of NODDI in the cervical spinal cord of multiple sclerosis patients
- 1 January 2017
- Published by Elsevier in NeuroImage: Clinical
- Vol. 15, 333-342
Open AccessApplication and evaluation of NODDI in the cervical spinal cord of multiple sclerosis patients
- 18 May 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (6) , 1608-1618
Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T
Purpose To empirically characterize and quantify the impact of gradient weighting schemes on the appearance and fidelity of diffusion tensor imaging of the human spinal cord in vivo in clinically relevant scan time equivalents (STE). Materials and Methods In five healthy controls at 3T, we evaluated test–retest reproducibility and performed voxelwise analysis of diffusion tensor imaging (DTI)‐derived indices (fractional anisotropy [FA], mean [MD], axial [AD], and radial [RD] diffusivity) in the cervical spinal cord to assess spatial dependencies of measurement error and differences across three different sampling schemes (6, 15, and 32 directions) at STE of 4.5, 9, and 18 minutes. A subjective assessment was also performed. Results With six directions, column‐specific errors are highest (effect size = 2.9%, 4.4%, 7.2% for FA in dorsal column, lateral column, and gray matter) and different than the 15‐direction scheme (P < 0.05). STE sequences with 15 and 32 directions exhibited small differences in error (P > 0.05). For FA and AD, measurement errors are prevalent in gray matter, while partial volume effects with cerebrospinal fluid heavily influence RD. Measurement errors decreased with increasing scan time (P < 0.01), albeit with diminishing returns at scan times longer than 9 minutes (P < 0.05). Conclusion A 15‐direction scheme of 9 minutes yields measurements of the cervical spinal cord with low error. J. Magn. Reson. Imaging 2016;44:1608–1618.
- 18 May 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (6) , 1608-1618
Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T
Purpose To empirically characterize and quantify the impact of gradient weighting schemes on the appearance and fidelity of diffusion tensor imaging of the human spinal cord in vivo in clinically relevant scan time equivalents (STE). Materials and Methods In five healthy controls at 3T, we evaluated test–retest reproducibility and performed voxelwise analysis of diffusion tensor imaging (DTI)‐derived indices (fractional anisotropy [FA], mean [MD], axial [AD], and radial [RD] diffusivity) in the cervical spinal cord to assess spatial dependencies of measurement error and differences across three different sampling schemes (6, 15, and 32 directions) at STE of 4.5, 9, and 18 minutes. A subjective assessment was also performed. Results With six directions, column‐specific errors are highest (effect size = 2.9%, 4.4%, 7.2% for FA in dorsal column, lateral column, and gray matter) and different than the 15‐direction scheme (P < 0.05). STE sequences with 15 and 32 directions exhibited small differences in error (P > 0.05). For FA and AD, measurement errors are prevalent in gray matter, while partial volume effects with cerebrospinal fluid heavily influence RD. Measurement errors decreased with increasing scan time (P < 0.01), albeit with diminishing returns at scan times longer than 9 minutes (P < 0.05). Conclusion A 15‐direction scheme of 9 minutes yields measurements of the cervical spinal cord with low error. J. Magn. Reson. Imaging 2016;44:1608–1618.
- 1 April 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (2) , 707-716
Incorporating dixon multi‐echo fat water separation for novel quantitative magnetization transfer of the human optic nerve in vivo
Purpose: The optic nerve (ON) represents the sole pathway between the eyes and brain; consequently, diseases of the ON can have dramatic effects on vision. However, quantitative magnetization transfer (qMT) applications in the ON have been limited to ex vivo studies, in part because of the fatty connective tissue that surrounds the ON, confounding the magnetization transfer (MT) experiment. Therefore, the aim of this study was to implement a multi‐echo Dixon fat‐water separation approach to remove the fat component from MT images.Methods: MT measurements were taken in a single slice of the ON and frontal lobe using a three‐echo Dixon readout, and the water and out‐of‐phase images were applied to a two‐pool model in ON tissue and brain white matter to evaluate the effectiveness of using Dixon fat‐water separation to remove fatty tissue from MT images.Results: White matter data showed no significant differences between image types; however, there was a significant increase (p < 0.05) in variation in the out‐of‐phase images in the ON relative to the water images.Conclusions: The results of this study demonstrate that Dixon fat‐water separation can be robustly used for accurate MT quantification of anatomies susceptible to partial volume effects resulting from fat. Magn Reson Med 77:707–716, 2017. © 2016 International Society for Magnetic Resonance in Medicine
- 1 April 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (2) , 707-716
Incorporating dixon multi‐echo fat water separation for novel quantitative magnetization transfer of the human optic nerve in vivo
Purpose: The optic nerve (ON) represents the sole pathway between the eyes and brain; consequently, diseases of the ON can have dramatic effects on vision. However, quantitative magnetization transfer (qMT) applications in the ON have been limited to ex vivo studies, in part because of the fatty connective tissue that surrounds the ON, confounding the magnetization transfer (MT) experiment. Therefore, the aim of this study was to implement a multi‐echo Dixon fat‐water separation approach to remove the fat component from MT images.Methods: MT measurements were taken in a single slice of the ON and frontal lobe using a three‐echo Dixon readout, and the water and out‐of‐phase images were applied to a two‐pool model in ON tissue and brain white matter to evaluate the effectiveness of using Dixon fat‐water separation to remove fatty tissue from MT images.Results: White matter data showed no significant differences between image types; however, there was a significant increase (p < 0.05) in variation in the out‐of‐phase images in the ON relative to the water images.Conclusions: The results of this study demonstrate that Dixon fat‐water separation can be robustly used for accurate MT quantification of anatomies susceptible to partial volume effects resulting from fat. Magn Reson Med 77:707–716, 2017. © 2016 International Society for Magnetic Resonance in Medicine