Loic Boussel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Loic Boussel has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
- Alastair J. Martin
Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
5 shared publications David Saloner
Department of Radiology and Biomedical Imaging, University of California, San Francisco, California
5 shared publicationsDidier Revel
Department of Radiology, Louis Pradel Hospital, CREATIS, CNRS UMR 5220, INSERM U1044, Lyon, France
4 shared publicationsPhilippe Douek
Department of Radiology, Louis Pradel Hospital, CREATIS, CNRS UMR 5220, INSERM U1044, Lyon, France
4 shared publicationsP Douek
3 shared publicationsP. Douek
Inserm U1044, CREATIS, CNRS UMR5220, INSA-Lyon, université Lyon 1, service de radiologie, hôpital Louis-Pradel, 28, avenue du Doyen-Jean-Line, 69500 Bron, France
3 shared publications
Latest Publications
- Open Access
- 22 February 2023
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (7) , 459-471
First Experience With a Whole-Body Spectral Photon-Counting CT Clinical Prototype
Spectral photon-counting computed tomography (SPCCT) technology holds great promise for becoming the next generation of computed tomography (CT) systems. Its technical characteristics have many advantages over conventional CT imaging. For example, SPCCT provides better spatial resolution, greater dose efficiency for ultra-low-dose and low-dose protocols, and tissue contrast superior to that of conventional CT. In addition, SPCCT takes advantage of several known approaches in the field of spectral CT imaging, such as virtual monochromatic imaging and material decomposition imaging. In addition, SPCCT takes advantage of a new approach in this field, known as K-edge imaging, which allows specific and quantitative imaging of a heavy atom-based contrast agent. Hence, the high potential of SPCCT systems supports their ongoing investigation in clinical research settings. In this review, we propose an overview of our clinical research experience of a whole-body SPCCT clinical prototype, to give an insight into the potential benefits for clinical human imaging on image quality, diagnostic confidence, and new approaches in spectral CT imaging.
- 22 February 2023
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 58 (7) , 459-471
Open AccessFirst Experience With a Whole-Body Spectral Photon-Counting CT Clinical Prototype
Spectral photon-counting computed tomography (SPCCT) technology holds great promise for becoming the next generation of computed tomography (CT) systems. Its technical characteristics have many advantages over conventional CT imaging. For example, SPCCT provides better spatial resolution, greater dose efficiency for ultra-low-dose and low-dose protocols, and tissue contrast superior to that of conventional CT. In addition, SPCCT takes advantage of several known approaches in the field of spectral CT imaging, such as virtual monochromatic imaging and material decomposition imaging. In addition, SPCCT takes advantage of a new approach in this field, known as K-edge imaging, which allows specific and quantitative imaging of a heavy atom-based contrast agent. Hence, the high potential of SPCCT systems supports their ongoing investigation in clinical research settings. In this review, we propose an overview of our clinical research experience of a whole-body SPCCT clinical prototype, to give an insight into the potential benefits for clinical human imaging on image quality, diagnostic confidence, and new approaches in spectral CT imaging.
- Top Cited PapersOpen Access
- 27 October 2021
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (4) , 212-221
First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography
Objectives: The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). Materials and Methods: In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 × 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 × 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Δ S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. Results: Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m2 [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Δ S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P ≤ 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. Conclusion: Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.
- 27 October 2021
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (4) , 212-221
Top Cited PapersOpen AccessFirst In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography
Objectives: The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). Materials and Methods: In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 × 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 × 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Δ S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. Results: Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m2 [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Δ S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P ≤ 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. Conclusion: Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.
- 8 March 2019
- Published by Elsevier in JMV-Journal de Médecine Vasculaire
- Vol. 44 (2) , 104
Ce qui est possible pour le futur est dans les tuyaux
- 8 March 2019
- Published by Elsevier in JMV-Journal de Médecine Vasculaire
- Vol. 44 (2) , 104
Ce qui est possible pour le futur est dans les tuyaux
- 1 March 2015
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 96 (3) , 265-272
Use of an automatic recording system for CT doses: Evaluation of the impact of iterative reconstruction on radiation exposure in clinical practice
- 1 March 2015
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 96 (3) , 265-272
Use of an automatic recording system for CT doses: Evaluation of the impact of iterative reconstruction on radiation exposure in clinical practice
- 1 August 2014
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 87 (1040) , 20130798
Photon counting spectral CT component analysis of coronary artery atherosclerotic plaque samples
To evaluate the capabilities of photon counting spectral CT to differentiate components of coronary atherosclerotic plaque based on differences in spectral attenuation and iodine-based contrast agent concentration. 10 calcified and 13 lipid-rich non-calcified histologically demonstrated atheromatous plaques from post-mortem human coronary arteries were scanned with a photon counting spectral CT scanner. Individual photons were counted and classified in one of six energy bins from 25 to 70 keV. Based on a maximum likelihood approach, maps of photoelectric absorption (PA), Compton scattering (CS) and iodine concentration (IC) were reconstructed. Intensity measurements were performed on each map in the vessel wall, the surrounding perivascular fat and the lipid-rich and the calcified plaques. PA and CS values are expressed relative to pure water values. A comparison between these different elements was performed using Kruskal-Wallis tests with pairwise post hoc Mann-Whitney U-tests and Sidak p-value adjustments. RESULTS for vessel wall, surrounding perivascular fat and lipid-rich and calcified plaques were, respectively, 1.19 ± 0.09, 0.73 ± 0.05, 1.08 ± 0.14 and 17.79 ± 6.70 for PA; 0.96 ± 0.02, 0.83 ± 0.02, 0.91 ± 0.03 and 2.53 ± 0.63 for CS; and 83.3 ± 10.1, 37.6 ± 8.1, 55.2 ± 14.0 and 4.9 ± 20.0 mmol l(-1) for IC, with a significant difference between all tissues for PA, CS and IC (p < 0.012). This study demonstrates the capability of energy-sensitive photon counting spectral CT to differentiate between calcifications and iodine-infused regions of human coronary artery atherosclerotic plaque samples by analysing differences in spectral attenuation and iodine-based contrast agent concentration. Photon counting spectral CT is a promising technique to identify plaque components by analysing differences in iodine-based contrast agent concentration, photoelectric attenuation and Compton scattering.
- 1 August 2014
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 87 (1040) , 20130798
Photon counting spectral CT component analysis of coronary artery atherosclerotic plaque samples
To evaluate the capabilities of photon counting spectral CT to differentiate components of coronary atherosclerotic plaque based on differences in spectral attenuation and iodine-based contrast agent concentration. 10 calcified and 13 lipid-rich non-calcified histologically demonstrated atheromatous plaques from post-mortem human coronary arteries were scanned with a photon counting spectral CT scanner. Individual photons were counted and classified in one of six energy bins from 25 to 70 keV. Based on a maximum likelihood approach, maps of photoelectric absorption (PA), Compton scattering (CS) and iodine concentration (IC) were reconstructed. Intensity measurements were performed on each map in the vessel wall, the surrounding perivascular fat and the lipid-rich and the calcified plaques. PA and CS values are expressed relative to pure water values. A comparison between these different elements was performed using Kruskal-Wallis tests with pairwise post hoc Mann-Whitney U-tests and Sidak p-value adjustments. RESULTS for vessel wall, surrounding perivascular fat and lipid-rich and calcified plaques were, respectively, 1.19 ± 0.09, 0.73 ± 0.05, 1.08 ± 0.14 and 17.79 ± 6.70 for PA; 0.96 ± 0.02, 0.83 ± 0.02, 0.91 ± 0.03 and 2.53 ± 0.63 for CS; and 83.3 ± 10.1, 37.6 ± 8.1, 55.2 ± 14.0 and 4.9 ± 20.0 mmol l(-1) for IC, with a significant difference between all tissues for PA, CS and IC (p < 0.012). This study demonstrates the capability of energy-sensitive photon counting spectral CT to differentiate between calcifications and iodine-infused regions of human coronary artery atherosclerotic plaque samples by analysing differences in spectral attenuation and iodine-based contrast agent concentration. Photon counting spectral CT is a promising technique to identify plaque components by analysing differences in iodine-based contrast agent concentration, photoelectric attenuation and Compton scattering.
- 8 May 2013
- Published by Springer Nature in European Radiology
- Vol. 23 (9) , 2405-2412
Acute myocardial infarction: early CT aspects of myocardial microcirculation obstruction after percutaneous coronary intervention
- 8 May 2013
- Published by Springer Nature in European Radiology
- Vol. 23 (9) , 2405-2412
Acute myocardial infarction: early CT aspects of myocardial microcirculation obstruction after percutaneous coronary intervention
- Open Access
- 22 August 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (18) , 5925-5947
Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT
Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.
- 22 August 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (18) , 5925-5947
Open AccessImage registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT
Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.
- 31 July 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (7) , 1007-1011
Temporal Stability of Dysmorphic Fusiform Aneurysms of the Intracranial Internal Carotid Artery
- 31 July 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (7) , 1007-1011
Temporal Stability of Dysmorphic Fusiform Aneurysms of the Intracranial Internal Carotid Artery
- 1 January 2011
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 258 (1) , 206-212
Ischemic Stroke: Etiologic Work-up with Multidetector CT of Heart and Extra- and Intracranial Arteries
To assess the potential of a single-session multidetector computed tomography (CT) protocol, as compared with established methods, for the etiologic work-up of acute ischemic stroke. Patients found to have recently experienced an ischemic stroke were recruited for this prospective study after institutional review board approval was obtained. Each patient was scheduled for two evaluation strategies: (a) a standard approach involving transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE), duplex ultrasonography (US) of the neck vessels, and magnetic resonance (MR) angiography of the neck and brain vessels; and (b) a protocol involving single-session multidetector CT of the heart, neck, and brain vessels. The authors sought to determine the major etiologic factors of stroke, including cardiac sources of embolism and atheroma of the aortic arch and the extra- and intracranial vessels, by using both strategies. Multidetector CT, MR imaging, and duplex US were performed in 46 patients, 39 of whom also underwent TEE. The sensitivity and specificity of multidetector CT were 72% (18 of 25 cases) and 95% (20 of 21 cases), respectively, for detection of cardiac sources and 100% (24 of 24 cases) and 91% (20 of 22 cases), respectively, for detection of major arterial atheroma. For the 46 cases of stroke, the final etiologic classifications determined by using the standard combination approach were cardiac sources in 20 (44%) cases, major arterial atheroma in nine (20%), multiple sources in four (9%), and cryptogenic sources in 13 (28%). Multidetector CT facilitated correct etiologic classification for 38 (83%) of the 46 patients. Multidetector CT is a promising tool for etiologic assessment of ischemic stroke, although the identification of minor cardiac sources with this examination requires the establishment of robust criteria.
- 1 January 2011
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 258 (1) , 206-212
Ischemic Stroke: Etiologic Work-up with Multidetector CT of Heart and Extra- and Intracranial Arteries
To assess the potential of a single-session multidetector computed tomography (CT) protocol, as compared with established methods, for the etiologic work-up of acute ischemic stroke. Patients found to have recently experienced an ischemic stroke were recruited for this prospective study after institutional review board approval was obtained. Each patient was scheduled for two evaluation strategies: (a) a standard approach involving transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE), duplex ultrasonography (US) of the neck vessels, and magnetic resonance (MR) angiography of the neck and brain vessels; and (b) a protocol involving single-session multidetector CT of the heart, neck, and brain vessels. The authors sought to determine the major etiologic factors of stroke, including cardiac sources of embolism and atheroma of the aortic arch and the extra- and intracranial vessels, by using both strategies. Multidetector CT, MR imaging, and duplex US were performed in 46 patients, 39 of whom also underwent TEE. The sensitivity and specificity of multidetector CT were 72% (18 of 25 cases) and 95% (20 of 21 cases), respectively, for detection of cardiac sources and 100% (24 of 24 cases) and 91% (20 of 22 cases), respectively, for detection of major arterial atheroma. For the 46 cases of stroke, the final etiologic classifications determined by using the standard combination approach were cardiac sources in 20 (44%) cases, major arterial atheroma in nine (20%), multiple sources in four (9%), and cryptogenic sources in 13 (28%). Multidetector CT facilitated correct etiologic classification for 38 (83%) of the 46 patients. Multidetector CT is a promising tool for etiologic assessment of ischemic stroke, although the identification of minor cardiac sources with this examination requires the establishment of robust criteria.
- 31 December 2010
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 19, S15
Measurement of Carotid Wall Thickness Using Ultrasound and Magnetic Resonance Imaging: Relative Contributions of the Intima-media and Adventitia
- 31 December 2010
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 19, S15
Measurement of Carotid Wall Thickness Using Ultrasound and Magnetic Resonance Imaging: Relative Contributions of the Intima-media and Adventitia