Stefan Boehme
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefan Boehme has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Klaus Ulrich Klein
Department of Anesthesia, General Intensive Care and Pain Management, Medical University of Vienna, 1090 Vienna, Austria
4 shared publications Klaus Markstaller
Department of Anaesthesiology, Medical Centre of the Johannes Gutenberg-University, Mainz, Germany ; Department of Anaesthesia, General Intensive Care and Pain Management, Medical University of Vienna, Vienna, Austria
3 shared publications- Matthias David
Klinik für Gynäkologie, Campus Virchow-Klinikum, Charité – Universitätsmedizin Berlin, Berlin, Deutschland
3 shared publications - Alexander Bentley
Department of Anesthesiology, Medical Center of the Johannes-Gutenberg University Mainz, Mainz, Germany
2 shared publications - Andreas Vogt
Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
2 shared publications Erik K. Hartmann
Department of Anaesthesiology, Medical Centre of the Johannes Gutenberg-University, Mainz, Germany
2 shared publications
Latest Publications
- Open Access
- 29 April 2014
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 14 (1) , 73
Determination of respiratory gas flow by electrical impedance tomography in an animal model of mechanical ventilation
A recent method determines regional gas flow of the lung by electrical impedance tomography (EIT). The aim of this study is to show the applicability of this method in a porcine model of mechanical ventilation in healthy and diseased lungs. Our primary hypothesis is that global gas flow measured by EIT can be correlated with spirometry. Our secondary hypothesis is that regional analysis of respiratory gas flow delivers physiologically meaningful results.
- 29 April 2014
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 14 (1) , 73
Open AccessDetermination of respiratory gas flow by electrical impedance tomography in an animal model of mechanical ventilation
A recent method determines regional gas flow of the lung by electrical impedance tomography (EIT). The aim of this study is to show the applicability of this method in a porcine model of mechanical ventilation in healthy and diseased lungs. Our primary hypothesis is that global gas flow measured by EIT can be correlated with spirometry. Our secondary hypothesis is that regional analysis of respiratory gas flow delivers physiologically meaningful results.
- Open Access
- 27 January 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (1) , e86638
Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT)
Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R2 = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R2 values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.
- 27 January 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (1) , e86638
Open AccessAssessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT)
Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R2 = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R2 values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.
- Open Access
- 27 September 2013
- Published by Springer Nature in BMC Research Notes
- Vol. 6 (1) , 385
TIP peptide inhalation in oleic acid-induced experimental lung injury: a post-hoc comparison
- 27 September 2013
- Published by Springer Nature in BMC Research Notes
- Vol. 6 (1) , 385
Open AccessTIP peptide inhalation in oleic acid-induced experimental lung injury: a post-hoc comparison
- Open Access
- 2 April 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (4) , e60591
Multi Frequency Phase Fluorimetry (MFPF) for Oxygen Partial Pressure Measurement: Ex Vivo Validation by Polarographic Clark-Type Electrode
Background Measurement of partial pressure of oxygen (P O2 ) at high temporal resolution remains a technological challenge. This study introduces a novel P O2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) P O2 measurements. Methodology/Principal Findings MFPF technology was first investigated in N = 8 anaesthetised pigs at F IO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each F IO2 level, blood samples were withdrawn and P O2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-P O2 readings were compared to CTE in an artificial circulatory setup (human packed red blood cells, haematocrit of 30%). The impacts of temperature (20, 30, 40°C) and blood flow (0.8, 1.6, 2.4, 3.2, 4.0 L min −1 ) on MFPF-P O2 measurements were assessed. MFPF response time in the gas- and blood-phase was determined. Porcine MFPF-P O2 ranged from 63 to 749 mmHg; the corresponding CTE samples from 43 to 712 mmHg. Linear regression: CTE = 15.59+1.18*MFPF (R 2 = 0.93; P <0.0001). Bland Altman analysis: mean diff 69.2 mmHg, range diff -50.1/215.6 mmHg, 1.96-SD limits -56.3/194.8 mmHg. In artificial circulatory setup, MFPF-P O2 ranged from 20 to 567 mmHg and CTE samples from 11 to 575 mmHg. Linear regression: CTE = −8.73+1.05*MFPF (R 2 = 0.99; P 0.05). MFPF response-time (monoexponential) was 1.48±0.26 s for the gas-phase and 1.51±0.20 s for the blood-phase. Conclusions/Significance MFPF-derived P O2 readings were reproducible and showed excellent correlation and good agreement with Clark-type electrode-based P O2 measurements. There was no relevant impact of temperature and blood flow upon MFPF-P O2 measurements. The response time of the MFPF FOXY-AL300 probe was adequate for real-time sensing in the blood phase.
- 2 April 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (4) , e60591
Open AccessMulti Frequency Phase Fluorimetry (MFPF) for Oxygen Partial Pressure Measurement: Ex Vivo Validation by Polarographic Clark-Type Electrode
Background Measurement of partial pressure of oxygen (P O2 ) at high temporal resolution remains a technological challenge. This study introduces a novel P O2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) P O2 measurements. Methodology/Principal Findings MFPF technology was first investigated in N = 8 anaesthetised pigs at F IO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each F IO2 level, blood samples were withdrawn and P O2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-P O2 readings were compared to CTE in an artificial circulatory setup (human packed red blood cells, haematocrit of 30%). The impacts of temperature (20, 30, 40°C) and blood flow (0.8, 1.6, 2.4, 3.2, 4.0 L min −1 ) on MFPF-P O2 measurements were assessed. MFPF response time in the gas- and blood-phase was determined. Porcine MFPF-P O2 ranged from 63 to 749 mmHg; the corresponding CTE samples from 43 to 712 mmHg. Linear regression: CTE = 15.59+1.18*MFPF (R 2 = 0.93; P <0.0001). Bland Altman analysis: mean diff 69.2 mmHg, range diff -50.1/215.6 mmHg, 1.96-SD limits -56.3/194.8 mmHg. In artificial circulatory setup, MFPF-P O2 ranged from 20 to 567 mmHg and CTE samples from 11 to 575 mmHg. Linear regression: CTE = −8.73+1.05*MFPF (R 2 = 0.99; P 0.05). MFPF response-time (monoexponential) was 1.48±0.26 s for the gas-phase and 1.51±0.20 s for the blood-phase. Conclusions/Significance MFPF-derived P O2 readings were reproducible and showed excellent correlation and good agreement with Clark-type electrode-based P O2 measurements. There was no relevant impact of temperature and blood flow upon MFPF-P O2 measurements. The response time of the MFPF FOXY-AL300 probe was adequate for real-time sensing in the blood phase.
- Open Access
- 16 January 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (1) , R8
Influence of respiratory rate and end-expiratory pressure variation on cyclic alveolar recruitment in an experimental lung injury model
Introduction: Cyclic alveolar recruitment/derecruitment (R/D) is an important mechanism of ventilator-associated lung injury. In experimental models this process can be measured with high temporal resolution by detection of respiratory-dependent oscillations of the paO2 (ΔpaO2). A previous study showed that end-expiratory collapse can be prevented by an increased respiratory rate in saline-lavaged rabbits. The current study compares the effects of increased positive end-expiratory pressure (PEEP) versus an individually titrated respiratory rate (RRind) on intra-tidal amplitude of Δ paO2 and on average paO2 in saline-lavaged pigs. Methods: Acute lung injury was induced by bronchoalveolar lavage in 16 anaesthetized pigs. R/D was induced and measured by a fast-responding intra-aortic probe measuring paO2. Ventilatory interventions (RRind (n = 8) versus extrinsic PEEP (n = 8)) were applied for 30 minutes to reduce Δ paO2. Haemodynamics, spirometry and Δ paO2 were monitored and the Ventilation/Perfusion distributions were assessed by multiple inert gas elimination. The main endpoints average and Δ paO2 following the interventions were analysed by Mann-Whitney-U-Test and Bonferroni's correction. The secondary parameters were tested in an explorative manner. Results: Both interventions reduced Δ paO2. In the RRind group, ΔpaO2 was significantly smaller (P < 0.001). The average paO2 continuously decreased following RRind and was significantly higher in the PEEP group (P < 0.001). A sustained difference of the ventilation/perfusion distribution and shunt fractions confirms these findings. The RRind application required less vasopressor administration. Conclusions: Different recruitment kinetics were found compared to previous small animal models and these differences were primarily determined by kinetics of end-expiratory collapse. In this porcine model, respiratory rate and increased PEEP were both effective in reducing the amplitude of paO2 oscillations. In contrast to a recent study in a small animal model, however, increased respiratory rate did not maintain end-expiratory recruitment and ultimately resulted in reduced average paO2 and increased shunt fraction.
- 16 January 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (1) , R8
Open AccessInfluence of respiratory rate and end-expiratory pressure variation on cyclic alveolar recruitment in an experimental lung injury model
Introduction: Cyclic alveolar recruitment/derecruitment (R/D) is an important mechanism of ventilator-associated lung injury. In experimental models this process can be measured with high temporal resolution by detection of respiratory-dependent oscillations of the paO2 (ΔpaO2). A previous study showed that end-expiratory collapse can be prevented by an increased respiratory rate in saline-lavaged rabbits. The current study compares the effects of increased positive end-expiratory pressure (PEEP) versus an individually titrated respiratory rate (RRind) on intra-tidal amplitude of Δ paO2 and on average paO2 in saline-lavaged pigs. Methods: Acute lung injury was induced by bronchoalveolar lavage in 16 anaesthetized pigs. R/D was induced and measured by a fast-responding intra-aortic probe measuring paO2. Ventilatory interventions (RRind (n = 8) versus extrinsic PEEP (n = 8)) were applied for 30 minutes to reduce Δ paO2. Haemodynamics, spirometry and Δ paO2 were monitored and the Ventilation/Perfusion distributions were assessed by multiple inert gas elimination. The main endpoints average and Δ paO2 following the interventions were analysed by Mann-Whitney-U-Test and Bonferroni's correction. The secondary parameters were tested in an explorative manner. Results: Both interventions reduced Δ paO2. In the RRind group, ΔpaO2 was significantly smaller (P < 0.001). The average paO2 continuously decreased following RRind and was significantly higher in the PEEP group (P < 0.001). A sustained difference of the ventilation/perfusion distribution and shunt fractions confirms these findings. The RRind application required less vasopressor administration. Conclusions: Different recruitment kinetics were found compared to previous small animal models and these differences were primarily determined by kinetics of end-expiratory collapse. In this porcine model, respiratory rate and increased PEEP were both effective in reducing the amplitude of paO2 oscillations. In contrast to a recent study in a small animal model, however, increased respiratory rate did not maintain end-expiratory recruitment and ultimately resulted in reduced average paO2 and increased shunt fraction.
- 23 September 2010
- Published by Taylor & Francis in Experimental Lung Research
- Vol. 37 (1) , 18-25
Novel technologies to detect atelectotrauma in the injured lung
Cyclical recruitment and derecruitment of lung parenchyma (R/D) remains a serious problem in ALI/ARDS patients, defined as atelectotrauma. Detection of cyclical R/D to titrate the optimal respiratory settings is of high clinical importance. Image-based technologies that are capable of detecting changes of lung ventilation within a respiratory cycle include dynamic computed tomography (dCT), synchrotron radiation computed tomography (SRCT), and electrical impedance tomography (EIT). Time-dependent intra-arterial oxygen tension monitoring represents an alternative approach to detect cyclical R/D, as cyclical R/D can result in oscillations of PaO₂ within a respiratory cycle. Continuous, ultrafast, on-line in vivo measurement of PaO₂ can be provided by an indwelling PaO₂ probe. In addition, monitoring of fast changes in SaO₂ by pulse oximetry technology at the bedside could also be used to detect those fast changes in oxygenation.
- 23 September 2010
- Published by Taylor & Francis in Experimental Lung Research
- Vol. 37 (1) , 18-25
Novel technologies to detect atelectotrauma in the injured lung
Cyclical recruitment and derecruitment of lung parenchyma (R/D) remains a serious problem in ALI/ARDS patients, defined as atelectotrauma. Detection of cyclical R/D to titrate the optimal respiratory settings is of high clinical importance. Image-based technologies that are capable of detecting changes of lung ventilation within a respiratory cycle include dynamic computed tomography (dCT), synchrotron radiation computed tomography (SRCT), and electrical impedance tomography (EIT). Time-dependent intra-arterial oxygen tension monitoring represents an alternative approach to detect cyclical R/D, as cyclical R/D can result in oscillations of PaO₂ within a respiratory cycle. Continuous, ultrafast, on-line in vivo measurement of PaO₂ can be provided by an indwelling PaO₂ probe. In addition, monitoring of fast changes in SaO₂ by pulse oximetry technology at the bedside could also be used to detect those fast changes in oxygenation.