Yu Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yu Ding has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Orlando P. Simonetti
Davis Heart and Lung Research Institute, The Ohio State University, Columbus, Ohio, USA
2 shared publicationsYiu-Cho Chung
Siemens Healthcare, USA, Columbus, Ohio, USA
2 shared publicationsMihaela Jekic
Davis Heart and Lung Research Institute, The Ohio State University, Columbus, Ohio, USA
1 shared publicationOrlando P Simonetti
1 shared publicationSubha V Raman
1 shared publicationYiu‐Cho Chung
Siemens Healthcare, Columbus, Ohio, USA
1 shared publication
Latest Publications
- Open Access
- 19 January 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (6) , 1786-1792
A new approach to autocalibrated dynamic parallel imaging based on the Karhunen‐Loeve transform: KL‐TSENSE and KL‐TGRAPPA
TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low‐pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a sliding‐window moving average when finding the autocalibrating signals. Both filtering methods are suboptimal in the least‐squares sense and may give rise to mismatches between the undersampled k‐space raw data and the corresponding coil sensitivities. Such mismatches may result in aliasing artifacts when imaging patients with heavy breathing, as in real‐time imaging of wall motion by MRI following a treadmill exercise stress test. In this study, we demonstrate the use of an optimal linear filter, i.e., the Karhunen‐Loeve transform filter, to estimate the channel sensitivity for TSENSE and acquire the autocalibration signals for TGRAPPA. Phantom experiments show that the new reconstruction method has comparable signal‐to‐noise ratio performance to traditional TSENSE/TGRAPPA reconstruction. In vivo real‐time cardiac cine experiments performed in five healthy volunteers post‐exercise during rapid respiration show that the new method significantly reduces the chest wall aliasing artifacts caused by respiratory motion (P < 0.001). Magn Reson Med, 2011.
- 19 January 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (6) , 1786-1792
Open AccessA new approach to autocalibrated dynamic parallel imaging based on the Karhunen‐Loeve transform: KL‐TSENSE and KL‐TGRAPPA
TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low‐pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a sliding‐window moving average when finding the autocalibrating signals. Both filtering methods are suboptimal in the least‐squares sense and may give rise to mismatches between the undersampled k‐space raw data and the corresponding coil sensitivities. Such mismatches may result in aliasing artifacts when imaging patients with heavy breathing, as in real‐time imaging of wall motion by MRI following a treadmill exercise stress test. In this study, we demonstrate the use of an optimal linear filter, i.e., the Karhunen‐Loeve transform filter, to estimate the channel sensitivity for TSENSE and acquire the autocalibration signals for TGRAPPA. Phantom experiments show that the new reconstruction method has comparable signal‐to‐noise ratio performance to traditional TSENSE/TGRAPPA reconstruction. In vivo real‐time cardiac cine experiments performed in five healthy volunteers post‐exercise during rapid respiration show that the new method significantly reduces the chest wall aliasing artifacts caused by respiratory motion (P < 0.001). Magn Reson Med, 2011.
- Open Access
- 25 February 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (3) , 782-789
A method to assess spatially variant noise in dynamic MR image series
Accurate measurement of spatially variant noise in MR images acquired using parallel imaging techniques is challenging. Image-based noise measurement methods such as the subtraction method proposed by the National Electrical Manufacturers Association or the multiple acquisition method often cannot be applied in vivo due to motion and/or dynamic contrast changes. Based on the Karhunen-Loeve transform and random matrix theory, we propose a novel method to accurately assess the noise variance in image series bearing temporal redundancy. The method fits the probability density function of eigenvalues from the temporal covariance matrix of the image series to the Marcenko-Pastur distribution. The accuracy of our method was validated using numerical simulation and an MR noise measurement experiment. The ability of this method to derive the g-factor map of a static phantom was validated against the multiple acquisition method. The method was applied to in vivo cardiac and brain image series and the results agreed with subtraction and multiple acquisition methods, respectively. This new image-based noise measurement method provides a practical means of retrospectively evaluating the noise level and/or g-factor map from multiframe image series. Magn Reson Med 63:782–789, 2010
- 25 February 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (3) , 782-789
Open AccessA method to assess spatially variant noise in dynamic MR image series
Accurate measurement of spatially variant noise in MR images acquired using parallel imaging techniques is challenging. Image-based noise measurement methods such as the subtraction method proposed by the National Electrical Manufacturers Association or the multiple acquisition method often cannot be applied in vivo due to motion and/or dynamic contrast changes. Based on the Karhunen-Loeve transform and random matrix theory, we propose a novel method to accurately assess the noise variance in image series bearing temporal redundancy. The method fits the probability density function of eigenvalues from the temporal covariance matrix of the image series to the Marcenko-Pastur distribution. The accuracy of our method was validated using numerical simulation and an MR noise measurement experiment. The ability of this method to derive the g-factor map of a static phantom was validated against the multiple acquisition method. The method was applied to in vivo cardiac and brain image series and the results agreed with subtraction and multiple acquisition methods, respectively. This new image-based noise measurement method provides a practical means of retrospectively evaluating the noise level and/or g-factor map from multiframe image series. Magn Reson Med 63:782–789, 2010
- 2 June 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (12) , 3909-3922
Application of the Karhunen–Loeve transform temporal image filter to reduce noise in real-time cardiac cine MRI
Real-time dynamic magnetic resonance imaging (MRI) typically sacrifices the signal-to-noise ratio (SNR) to achieve higher spatial and temporal resolution. Spatial and/or temporal filtering (e.g., low-pass filtering or averaging) of dynamic images improves the SNR at the expense of edge sharpness. We describe the application of a temporal filter for dynamic MR image series based on the Karhunen-Loeve transform (KLT) to remove random noise without blurring stationary or moving edges and requiring no training data. In this paper, we present several properties of this filter and their effects on filter performance, and propose an automatic way to find the filter cutoff based on the autocorrelation of the eigenimages. Numerical simulation and in vivo real-time cardiac cine MR image series spanning multiple cardiac cycles acquired using multi-channel sensitivity-encoded MRI, i.e., parallel imaging, are used to validate and demonstrate these properties. We found that in this application, the noise standard deviation was reduced to 42% of the original with no apparent image blurring by using the proposed filter cutoff. Greater noise reduction can be achieved by increasing the length of the image series. This advantage of KLT filtering provides flexibility in the form of another scan parameter to trade for SNR.
- 2 June 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (12) , 3909-3922
Application of the Karhunen–Loeve transform temporal image filter to reduce noise in real-time cardiac cine MRI
Real-time dynamic magnetic resonance imaging (MRI) typically sacrifices the signal-to-noise ratio (SNR) to achieve higher spatial and temporal resolution. Spatial and/or temporal filtering (e.g., low-pass filtering or averaging) of dynamic images improves the SNR at the expense of edge sharpness. We describe the application of a temporal filter for dynamic MR image series based on the Karhunen-Loeve transform (KLT) to remove random noise without blurring stationary or moving edges and requiring no training data. In this paper, we present several properties of this filter and their effects on filter performance, and propose an automatic way to find the filter cutoff based on the autocorrelation of the eigenimages. Numerical simulation and in vivo real-time cardiac cine MR image series spanning multiple cardiac cycles acquired using multi-channel sensitivity-encoded MRI, i.e., parallel imaging, are used to validate and demonstrate these properties. We found that in this application, the noise standard deviation was reduced to 42% of the original with no apparent image blurring by using the proposed filter cutoff. Greater noise reduction can be achieved by increasing the length of the image series. This advantage of KLT filtering provides flexibility in the form of another scan parameter to trade for SNR.