Zeev V. Maizlin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zeev V. Maizlin has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Jason J. Clement
St. Paul’s Hospital
8 shared publicationsPatrick M. Vos
St. Paul’s Hospital
8 shared publicationsJacqueline A. Brown
Department of Radiology, St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada
7 shared publicationsJohn M. Kirby
From the Department of Radiology, McMaster University Medical Centre, Hamilton, Ontario, Canada (ZVM, HG, JMK, PV); Rappaport Faculty of Medicine, Technion, Haifa, Israel (LM); Department of Medical Imaging, Royal Columbian Hospital, New Westminster, British Columbia (JRS); and Department of Radiology, St. Paul's Hospital, Vancouver, British Columbia, Canada (JJC)
3 shared publicationsParag Vora
From the Department of Radiology, McMaster University Medical Centre, Hamilton, Ontario, Canada (ZVM, HG, JMK, PV); Rappaport Faculty of Medicine, Technion, Haifa, Israel (LM); Department of Medical Imaging, Royal Columbian Hospital, New Westminster, British Columbia (JRS); and Department of Radiology, St. Paul's Hospital, Vancouver, British Columbia, Canada (JJC)
3 shared publicationsAndrew C. Mason
Department of Medical Imaging, Ridge Meadows Hospital, Maple Ridge, British Columbia, Canada
2 shared publications
Latest Publications
- 15 March 2012
- Published by Springer Nature in Emergency Radiology
- Vol. 19 (4) , 317-322
Stone foreign body—radiographic and CT appearance
- 15 March 2012
- Published by Springer Nature in Emergency Radiology
- Vol. 19 (4) , 317-322
Stone foreign body—radiographic and CT appearance
- 1 January 2012
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 36 (2) , 161-164
Do We Really Need to Thank the Beatles for the Financing of the Development of the Computed Tomography Scanner?
It is commonly believed that the revenues from the selling of the Beatles' records by Electric and Musical Industries (EMI) allowed the company to develop the computed tomography (CT) scanner. Some went to define this as the Beatles' gift to medicine. However, significant controversies and discrepancies arise from analysis of this statement, making its correctness doubtful. The details of financing required for the CT development and the part of EMI in financial input have never been publicly announced. This work analyzes the financial contributions to the CT development and investigates if the revenues received from the sales of the Beatles' records were used for the creation of the CT scanner. Timeline of the development of the EMI CT scanner and the financial inputs of EMI and British Department of Health and Social Security (DHSS) were assessed. Without salary expenses to Godfrey Hounsfield and his team, the development of the CT scanner cost EMI approximately £100,000. The British DHSS's expenses were £606,000. Hence, the financial contribution of DHSS into the development of the CT scanner was significantly bigger than that of EMI. Accordingly, British tax payers and officials of British DHSS are to be thanked for the CT scanner. The Beatles' input into the world's culture is valuable and does not require decoration by nonexistent connection to the development of CT. A positive aspect to this misconception is that it keeps in public memory the name of the company that developed the CT scanner.
- 1 January 2012
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 36 (2) , 161-164
Do We Really Need to Thank the Beatles for the Financing of the Development of the Computed Tomography Scanner?
It is commonly believed that the revenues from the selling of the Beatles' records by Electric and Musical Industries (EMI) allowed the company to develop the computed tomography (CT) scanner. Some went to define this as the Beatles' gift to medicine. However, significant controversies and discrepancies arise from analysis of this statement, making its correctness doubtful. The details of financing required for the CT development and the part of EMI in financial input have never been publicly announced. This work analyzes the financial contributions to the CT development and investigates if the revenues received from the sales of the Beatles' records were used for the creation of the CT scanner. Timeline of the development of the EMI CT scanner and the financial inputs of EMI and British Department of Health and Social Security (DHSS) were assessed. Without salary expenses to Godfrey Hounsfield and his team, the development of the CT scanner cost EMI approximately £100,000. The British DHSS's expenses were £606,000. Hence, the financial contribution of DHSS into the development of the CT scanner was significantly bigger than that of EMI. Accordingly, British tax payers and officials of British DHSS are to be thanked for the CT scanner. The Beatles' input into the world's culture is valuable and does not require decoration by nonexistent connection to the development of CT. A positive aspect to this misconception is that it keeps in public memory the name of the company that developed the CT scanner.
- 30 November 2011
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 25 (4) , 558-561
How to Measure Scapholunate and Cobb’s Angles on MRI and CT
The measurement of angles between anatomical structures is common in radiological and orthopedic practice. Frequently used measurements include scapholunate angle for assessment of wrist instability and Cobb’s angle used for assessment of scoliosis. Measurements of these angles are easily performed on plain X-ray radiographs. However, the situation is more complicated when these measurements are to be performed on cross-sectional (CT or MRI) examinations. On some of the diagnostic workstations, it is not possible to perform angle measurements between the structures if they are not identified on the same image and are located on different images of the same projection or plane. We present a simple solution to measure angles between structures on different images that can be used both in CT and MR.
- 30 November 2011
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 25 (4) , 558-561
How to Measure Scapholunate and Cobb’s Angles on MRI and CT
The measurement of angles between anatomical structures is common in radiological and orthopedic practice. Frequently used measurements include scapholunate angle for assessment of wrist instability and Cobb’s angle used for assessment of scoliosis. Measurements of these angles are easily performed on plain X-ray radiographs. However, the situation is more complicated when these measurements are to be performed on cross-sectional (CT or MRI) examinations. On some of the diagnostic workstations, it is not possible to perform angle measurements between the structures if they are not identified on the same image and are located on different images of the same projection or plane. We present a simple solution to measure angles between structures on different images that can be used both in CT and MR.
- 28 December 2010
- Published by Wiley in Journal of Neuroimaging
- Vol. 21 (1) , 1-4
Linguistic History of Posterior Reversible Encephalopathy Syndrome: Mirror of Developing Knowledge
The term posterior reversible encephalopathy syndrome (PRES) was first proposed in 2000. Since then, the acronym PRES has become very popular in imaging and clinical literature as it is short, easy to say and remember, and neatly couples the frequent localization of neuroimaging findings along with the typical outcome of this syndrome. Another possible reason for the popularity of this acronym in clinical circles is the connotation of PRES with (elevated blood) PRESsure, as a majority of cases are believed to be associated with hypertension. However, problems exist with the interpretation and common understanding of PRES, questioning the appropriateness of "P" and "R" in the acronym. The linguistic issues related to the acronym of PRES are interesting. the aim of this work is to analyze the controversies related to the acronym of PRES. in 2006, modifying the meaning of the acronym was suggested, renaming it Potentially Reversible Encephalopathy Syndrome in order to adjust to the cases when posterior involvement is not prominent and emphasize that the reversibility is not spontaneous. This meant the creation of a backronym, where the new phrase is constructed by starting with an existing acronym. this new backronym indicates that the original acronym of PRES has become a misnomer.
- 28 December 2010
- Published by Wiley in Journal of Neuroimaging
- Vol. 21 (1) , 1-4
Linguistic History of Posterior Reversible Encephalopathy Syndrome: Mirror of Developing Knowledge
The term posterior reversible encephalopathy syndrome (PRES) was first proposed in 2000. Since then, the acronym PRES has become very popular in imaging and clinical literature as it is short, easy to say and remember, and neatly couples the frequent localization of neuroimaging findings along with the typical outcome of this syndrome. Another possible reason for the popularity of this acronym in clinical circles is the connotation of PRES with (elevated blood) PRESsure, as a majority of cases are believed to be associated with hypertension. However, problems exist with the interpretation and common understanding of PRES, questioning the appropriateness of "P" and "R" in the acronym. The linguistic issues related to the acronym of PRES are interesting. the aim of this work is to analyze the controversies related to the acronym of PRES. in 2006, modifying the meaning of the acronym was suggested, renaming it Potentially Reversible Encephalopathy Syndrome in order to adjust to the cases when posterior involvement is not prominent and emphasize that the reversibility is not spontaneous. This meant the creation of a backronym, where the new phrase is constructed by starting with an existing acronym. this new backronym indicates that the original acronym of PRES has become a misnomer.
- 1 August 2010
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 195 (2) , W96-W104
Radiologic Signs of Weapons and Munitions: How Will Noncombatants Recognize Them?
OBJECTIVE. The purpose of this work was to show the radiologic signs named after weapons and munitions along with their military counterparts to help radiologists recognize these signs, which will allow confident interpretation and diagnosis.CONCLUSION. Numerous pathologic conditions have classic radiologic manifestations that resemble weapons and ammunition. Most of these signs are highly memorable and easy to recognize. However, the names of the weapons (some of them antique and some not commonly known) may confuse radiologists who are not familiar with the appearance of such weapons as the scimitar, bayonet, or dagger. The value of the signs is reduced if the radiologist is unfamiliar with the appearance of the corresponding weapon.
- 1 August 2010
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 195 (2) , W96-W104
Radiologic Signs of Weapons and Munitions: How Will Noncombatants Recognize Them?
OBJECTIVE. The purpose of this work was to show the radiologic signs named after weapons and munitions along with their military counterparts to help radiologists recognize these signs, which will allow confident interpretation and diagnosis.CONCLUSION. Numerous pathologic conditions have classic radiologic manifestations that resemble weapons and ammunition. Most of these signs are highly memorable and easy to recognize. However, the names of the weapons (some of them antique and some not commonly known) may confuse radiologists who are not familiar with the appearance of such weapons as the scimitar, bayonet, or dagger. The value of the signs is reduced if the radiologist is unfamiliar with the appearance of the corresponding weapon.
- 1 March 2010
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 53 (3) , 308-314
Can CT Replace MRI in Preoperative Assessment of the Circumferential Resection Margin in Rectal Cancer?
The objective of this study was to compare the accuracy of multidetector-row CT with conventional MRI in diagnosis of rectal cancer invasion of the mesorectal fascial envelope. During a 2-year period, all patients were enrolled in this study who had biopsy-proven rectal carcinoma and were referred, as a part of the routine preoperative staging workup, for a CT scan of the abdomen and pelvis and also an MRI of the pelvis. All examinations were reviewed independently by 2 radiologists who were blinded from one another, from the findings of the other modality, and from clinical information. Both observers were dedicated abdominal radiologists who are experienced in reading pelvic CT and MRI. Categorical agreement between MRI and multidetector-row CT for all the evaluated parameters of the tumor position, mesorectal fascia, and lymph nodes, as well as the interobserver agreement between CT and MRI, was determined by the intraclass correlation weighted kappa statistic to measure the data set's consistency. Among the study's 92 patients, the tumor characteristics suggested by multidetector-row CT agreed with those of MRI, with a weighted κ ranging from 0.488 to 0.748 for the first reader and 0.577 to 0.800 for the second reader. Interobserver agreement ranged from 0.506 to 0.746. Agreement regarding mesorectal fascia characteristics differed significantly between multidetector-row CT and MRI, depending on the level of assessment. In the distal rectum, agreement was 0.207 for the first reader and 0.385 for the second reader. In the mid rectum, agreement was 0.420 and 0.527, respectively, and in the proximal rectum agreement was 0.508 and 0.520. Interobserver agreement was 0.737 at the distal level and 0.700 at the mid and proximal levels. Agreement regarding measurement of the distance from the tumor to the mesorectal fascia was 0.425 for the first reader and 0.723 for the second reader, with interobserver agreement of 0.766. Agreement in assessment of the number of lymph nodes ranged from 0.743 to 0.787 for the first reader and 0.754 to 0.840 for the second reader. Interobserver agreement ranged from 0.779 to 0.841. Agreement in assessment of the size of the lymph nodes ranged from 0.540 to 0.830 for the first reader and 0.850 to 0.940 for the second reader. Interobserver agreement ranged from 0.900 to 0.920. Agreement in assessment of the distance from nodes to the mesorectal fascia was 0.320 for the first reader and 0.401 for the second reader, with interobserver agreement of 0.950. The results of this study differ from previously published data by demonstrating substantial agreement between readers in multidetector-row CT assessment of the tumor, mesorectal fascia, and lymph nodes. With the exceptions of mesorectal fascia in the distal rectum and the distance from the nodes to mesorectal fascia, other evaluated parameters were assessed with moderate and substantial agreement between multidetector-row CT and MRI. However, our findings suggest that multidetector-row CT does not correlate well enough with MRI findings to replace it in rectal cancer staging.
- 1 March 2010
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 53 (3) , 308-314
Can CT Replace MRI in Preoperative Assessment of the Circumferential Resection Margin in Rectal Cancer?
The objective of this study was to compare the accuracy of multidetector-row CT with conventional MRI in diagnosis of rectal cancer invasion of the mesorectal fascial envelope. During a 2-year period, all patients were enrolled in this study who had biopsy-proven rectal carcinoma and were referred, as a part of the routine preoperative staging workup, for a CT scan of the abdomen and pelvis and also an MRI of the pelvis. All examinations were reviewed independently by 2 radiologists who were blinded from one another, from the findings of the other modality, and from clinical information. Both observers were dedicated abdominal radiologists who are experienced in reading pelvic CT and MRI. Categorical agreement between MRI and multidetector-row CT for all the evaluated parameters of the tumor position, mesorectal fascia, and lymph nodes, as well as the interobserver agreement between CT and MRI, was determined by the intraclass correlation weighted kappa statistic to measure the data set's consistency. Among the study's 92 patients, the tumor characteristics suggested by multidetector-row CT agreed with those of MRI, with a weighted κ ranging from 0.488 to 0.748 for the first reader and 0.577 to 0.800 for the second reader. Interobserver agreement ranged from 0.506 to 0.746. Agreement regarding mesorectal fascia characteristics differed significantly between multidetector-row CT and MRI, depending on the level of assessment. In the distal rectum, agreement was 0.207 for the first reader and 0.385 for the second reader. In the mid rectum, agreement was 0.420 and 0.527, respectively, and in the proximal rectum agreement was 0.508 and 0.520. Interobserver agreement was 0.737 at the distal level and 0.700 at the mid and proximal levels. Agreement regarding measurement of the distance from the tumor to the mesorectal fascia was 0.425 for the first reader and 0.723 for the second reader, with interobserver agreement of 0.766. Agreement in assessment of the number of lymph nodes ranged from 0.743 to 0.787 for the first reader and 0.754 to 0.840 for the second reader. Interobserver agreement ranged from 0.779 to 0.841. Agreement in assessment of the size of the lymph nodes ranged from 0.540 to 0.830 for the first reader and 0.850 to 0.940 for the second reader. Interobserver agreement ranged from 0.900 to 0.920. Agreement in assessment of the distance from nodes to the mesorectal fascia was 0.320 for the first reader and 0.401 for the second reader, with interobserver agreement of 0.950. The results of this study differ from previously published data by demonstrating substantial agreement between readers in multidetector-row CT assessment of the tumor, mesorectal fascia, and lymph nodes. With the exceptions of mesorectal fascia in the distal rectum and the distance from the nodes to mesorectal fascia, other evaluated parameters were assessed with moderate and substantial agreement between multidetector-row CT and MRI. However, our findings suggest that multidetector-row CT does not correlate well enough with MRI findings to replace it in rectal cancer staging.
- Open Access
- 1 February 2010
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 61 (1) , 44-53
People behind Exclusive Eponyms of Radiologic Signs (Part II)
- 1 February 2010
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 61 (1) , 44-53
Open AccessPeople behind Exclusive Eponyms of Radiologic Signs (Part II)
- 1 January 2010
- Vol. 76, a3
Displacement of the temporomandibular joint disk: correlation between clinical findings and MRI characteristics.
Disk displacement frequently causes dysfunction of the temporomandibular joint (TMJ). Magnetic resonance imaging (MRI) of the TMJ is 95% accurate in the assessment of disk position and form. Various restorative procedures are used for treatment of disk displacement. However, several authors have noted a lack of correlation between MRI findings of disk displacement and the extent of pain and dysfunction of the TMJ. The purpose of this study was to evaluate whether MRI findings of various degrees of disk displacement could be correlated with the presence of clinical signs and symptoms in patients with a clinical disorder of the TMJ. One hundred and forty-four TMJs (in 72 patients) were imaged. Displacement of the posterior band in relation to the condyle was quantified as mild or significant. Disk displacement was found in 45 (54%) of the 84 symptomatic joints and 13 (22%) of the 60 asymptomatic joints. Among the 84 symptomatic joints, 31 (37%) had disk displacement with reduction and 14 (17%) had disk displacement without reduction. In the latter group, 11 (79%) of the 14 joints had significant displacement of the posterior band (8 or 9 o'clock) and 21% had mild displacement of the posterior band (10 o'clock). Of the 60 clinically asymptomatic joints, 47 (78%) had no signs of disk displacement on MRI, whereas 13 (22%) had disk displacement with reduction. None of the asymptomatic joints had disk displacement without reduction. The difference in occurrence of disk displacement between symptomatic and asymptomatic joints was statistically significant (54% vs. 22%; p < 0.001). However, the difference in occurrence of disk displacement with reduction of the disk on mouth opening was not statistically significant (37% vs. 22%; p = 0.06). Disk displacement on MRI correlated well with clinical symptoms in cases of significant disk displacement and in cases of disk displacement without reduction. When disk displacement with reduction was mild, there was no statistically significant difference between symptomatic and asymptomatic joints, which suggests that other causes should be considered.
- 1 January 2010
- Vol. 76, a3
Displacement of the temporomandibular joint disk: correlation between clinical findings and MRI characteristics.
Disk displacement frequently causes dysfunction of the temporomandibular joint (TMJ). Magnetic resonance imaging (MRI) of the TMJ is 95% accurate in the assessment of disk position and form. Various restorative procedures are used for treatment of disk displacement. However, several authors have noted a lack of correlation between MRI findings of disk displacement and the extent of pain and dysfunction of the TMJ. The purpose of this study was to evaluate whether MRI findings of various degrees of disk displacement could be correlated with the presence of clinical signs and symptoms in patients with a clinical disorder of the TMJ. One hundred and forty-four TMJs (in 72 patients) were imaged. Displacement of the posterior band in relation to the condyle was quantified as mild or significant. Disk displacement was found in 45 (54%) of the 84 symptomatic joints and 13 (22%) of the 60 asymptomatic joints. Among the 84 symptomatic joints, 31 (37%) had disk displacement with reduction and 14 (17%) had disk displacement without reduction. In the latter group, 11 (79%) of the 14 joints had significant displacement of the posterior band (8 or 9 o'clock) and 21% had mild displacement of the posterior band (10 o'clock). Of the 60 clinically asymptomatic joints, 47 (78%) had no signs of disk displacement on MRI, whereas 13 (22%) had disk displacement with reduction. None of the asymptomatic joints had disk displacement without reduction. The difference in occurrence of disk displacement between symptomatic and asymptomatic joints was statistically significant (54% vs. 22%; p < 0.001). However, the difference in occurrence of disk displacement with reduction of the disk on mouth opening was not statistically significant (37% vs. 22%; p = 0.06). Disk displacement on MRI correlated well with clinical symptoms in cases of significant disk displacement and in cases of disk displacement without reduction. When disk displacement with reduction was mild, there was no statistically significant difference between symptomatic and asymptomatic joints, which suggests that other causes should be considered.
- 1 October 2009
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 60 (4) , 201-212
People behind Exclusive Eponyms of Radiologic Signs (Part I)
- 1 October 2009
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 60 (4) , 201-212
People behind Exclusive Eponyms of Radiologic Signs (Part I)
- Open Access
- 1 April 2009
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 60 (2) , 88-90
Easy Ways to Remember the Progression of MRI Signal Intensity Changes of Intracranial Hemorrhage
- 1 April 2009
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 60 (2) , 88-90
Open AccessEasy Ways to Remember the Progression of MRI Signal Intensity Changes of Intracranial Hemorrhage