Casper W. Bollen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Casper W. Bollen has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Adrianus J. van Vught
University Medical Center Utrecht
2 shared publicationsCuno S. P. M. Uiterwaal
University Medical Center Utrecht
2 shared publications- Cuno Spm Uiterwaal
Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht, The Netherlands
2 shared publications A J Van Vught
1 shared publication- Adrianus J van Vught
Department of Pediatric Intensive Care, University Medical Center Utrecht, Lundlaan 6, Utrecht, 3584 EA, the Netherlands
1 shared publication - Adrianus J. van Vught
Wilhelmina Children’s Hospital, University Medical Center Utrecht
1 shared publication
Latest Publications
- 15 September 2017
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 196 (6) , 727-733
Severity of Hypoxemia and Effect of High-Frequency Oscillatory Ventilation in Acute Respiratory Distress Syndrome
Rationale: High-frequency oscillatory ventilation (HFOV) is theoretically beneficial for lung protection, but the results of clinical trials are inconsistent, with study-level meta-analyses suggesting no significant effect on mortality. Objectives: The aim of this individual patient data meta-analysis was to identify acute respiratory distress syndrome (ARDS) patient subgroups with differential outcomes from HFOV. Methods: After a comprehensive search for trials, two reviewers independently identified randomized trials comparing HFOV with conventional ventilation for adults with ARDS. Prespecified effect modifiers were tested using multivariable hierarchical logistic regression models, adjusting for important prognostic factors and clustering effects. Measurements and Main Results: Data from 1,552 patients in four trials were analyzed, applying uniform definitions for study variables and outcomes. Patients had a mean baseline PaO2/FiO2 of 114 ± 39 mm Hg; 40% had severe ARDS (PaO2/FiO2 <100 mm Hg). Mortality at 30 days was 321 of 785 (40.9%) for HFOV patients versus 288 of 767 (37.6%) for control subjects (adjusted odds ratio, 1.17; 95% confidence interval, 0.94–1.46; P = 0.16). This treatment effect varied, however, depending on baseline severity of hypoxemia (P = 0.0003), with harm increasing with PaO2/FiO2 among patients with mild-moderate ARDS, and the possibility of decreased mortality in patients with very severe ARDS. Compliance and body mass index did not modify the treatment effect. HFOV increased barotrauma risk compared with conventional ventilation (adjusted odds ratio, 1.75; 95% confidence interval, 1.04–2.96; P = 0.04). Conclusions: HFOV increases mortality for most patients with ARDS but may improve survival among patients with severe hypoxemia on conventional mechanical ventilation.
- 15 September 2017
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 196 (6) , 727-733
Severity of Hypoxemia and Effect of High-Frequency Oscillatory Ventilation in Acute Respiratory Distress Syndrome
Rationale: High-frequency oscillatory ventilation (HFOV) is theoretically beneficial for lung protection, but the results of clinical trials are inconsistent, with study-level meta-analyses suggesting no significant effect on mortality. Objectives: The aim of this individual patient data meta-analysis was to identify acute respiratory distress syndrome (ARDS) patient subgroups with differential outcomes from HFOV. Methods: After a comprehensive search for trials, two reviewers independently identified randomized trials comparing HFOV with conventional ventilation for adults with ARDS. Prespecified effect modifiers were tested using multivariable hierarchical logistic regression models, adjusting for important prognostic factors and clustering effects. Measurements and Main Results: Data from 1,552 patients in four trials were analyzed, applying uniform definitions for study variables and outcomes. Patients had a mean baseline PaO2/FiO2 of 114 ± 39 mm Hg; 40% had severe ARDS (PaO2/FiO2 <100 mm Hg). Mortality at 30 days was 321 of 785 (40.9%) for HFOV patients versus 288 of 767 (37.6%) for control subjects (adjusted odds ratio, 1.17; 95% confidence interval, 0.94–1.46; P = 0.16). This treatment effect varied, however, depending on baseline severity of hypoxemia (P = 0.0003), with harm increasing with PaO2/FiO2 among patients with mild-moderate ARDS, and the possibility of decreased mortality in patients with very severe ARDS. Compliance and body mass index did not modify the treatment effect. HFOV increased barotrauma risk compared with conventional ventilation (adjusted odds ratio, 1.75; 95% confidence interval, 1.04–2.96; P = 0.04). Conclusions: HFOV increases mortality for most patients with ARDS but may improve survival among patients with severe hypoxemia on conventional mechanical ventilation.
- 10 April 2014
- Published by Springer Nature
- p. 559-602
Indications for Nonconventional Ventilation Modes
- 10 April 2014
- Published by Springer Nature
- p. 559-602
Indications for Nonconventional Ventilation Modes
- Open Access
- 24 February 2007
- Published by Springer Nature in Intensive Care Medicine
- Vol. 33 (4) , 680-688
Meta-regression analysis of high-frequency ventilation vs conventional ventilation in infant respiratory distress syndrome
There is considerable heterogeneity among randomized trials comparing high-frequency ventilation (HFV) with conventional mechanical ventilation (CMV) in premature neonates with respiratory distress syndrome. We investigated what factors explained differences in outcome among these trials. Meta-regression analysis of 15 randomized trials. Variables were extracted to explain heterogeneity: year of publication; use of Sensormedics 3100A ventilator for HFV; time on CMV prior to start of study; gestational age; use of surfactant; high lung volume strategy in HFV; and lung protective ventilation strategy in CMV and baseline risk. Chronic lung disease (CLD) and death or CLD were outcome measures. Relative risk ratios were calculated to estimate effect sizes of explanatory variables on reported relative risks. Adjusted estimates of relative risk ratios of high lung volume strategy and lung protective ventilation strategy were 0.42 (95% CI 0.06–2.48) and 2.02 (95% CI 0.18–23.12) for CLD, respectively. The effect of gestational age was less pronounced (RRR = 1.17 (95% CI 0.16–8.32) for CLD, respectively). Use of Sensormedics and prior time on CMV had the smallest effects [RRR = 0.96 (95% CI 0.47–1.94) and RRR = 0.85 (95% CI 0.58–1.24) for CLD, respectively)]. The same results applied to CLD or death as outcome. Variation in ventilation strategies that were used in trials comparing HFV with CMV in premature neonates offered the most likely explanation for the observed differences in the outcome of these trials compared with other explanatory factors.
- 24 February 2007
- Published by Springer Nature in Intensive Care Medicine
- Vol. 33 (4) , 680-688
Open AccessMeta-regression analysis of high-frequency ventilation vs conventional ventilation in infant respiratory distress syndrome
There is considerable heterogeneity among randomized trials comparing high-frequency ventilation (HFV) with conventional mechanical ventilation (CMV) in premature neonates with respiratory distress syndrome. We investigated what factors explained differences in outcome among these trials. Meta-regression analysis of 15 randomized trials. Variables were extracted to explain heterogeneity: year of publication; use of Sensormedics 3100A ventilator for HFV; time on CMV prior to start of study; gestational age; use of surfactant; high lung volume strategy in HFV; and lung protective ventilation strategy in CMV and baseline risk. Chronic lung disease (CLD) and death or CLD were outcome measures. Relative risk ratios were calculated to estimate effect sizes of explanatory variables on reported relative risks. Adjusted estimates of relative risk ratios of high lung volume strategy and lung protective ventilation strategy were 0.42 (95% CI 0.06–2.48) and 2.02 (95% CI 0.18–23.12) for CLD, respectively. The effect of gestational age was less pronounced (RRR = 1.17 (95% CI 0.16–8.32) for CLD, respectively). Use of Sensormedics and prior time on CMV had the smallest effects [RRR = 0.96 (95% CI 0.47–1.94) and RRR = 0.85 (95% CI 0.58–1.24) for CLD, respectively)]. The same results applied to CLD or death as outcome. Variation in ventilation strategies that were used in trials comparing HFV with CMV in premature neonates offered the most likely explanation for the observed differences in the outcome of these trials compared with other explanatory factors.
- 1 November 2006
- Published by Wolters Kluwer Health in Epidemiology
- Vol. 17 (6) , 644-649
Sequential Meta-analysis of Past Clinical Trials to Determine the Use of a New Trial
Background: Clinical trials can be stopped early based on interim analyses or sequential analyses. In principle, sequential analyses can also be used to decide whether enough evidence has been gathered in completed trials to make further trials unnecessary. We demonstrate such an application through a retrospective analysis of clinical trials comparing ventilation methods for the treatment of preterm newborns. Methods: We identified 5 recent trials that compared high-frequency ventilation with conventional mechanical ventilation in the treatment of preterm newborns. Death or chronic lung disease and chronic lung disease in survivors were the primary clinical outcomes of interest. We applied sequential meta-analyses to these 5 studies. Results: After including the first study of the last 5 trials in a sequential meta-analysis, the boundary of "no clinically relevant effect" was crossed for both outcomes (death or chronic lung disease). A sensitivity analysis using a reduction in the size of assumed clinically relevant effect showed the same findings after 2 trials. Conclusions: Sequential meta-analyses showed that a lack of clinically relevant effect had been established after the first of the 5 trials. If such an analysis had been conducted after the first or second of these clinical trials, it might have led to changes in the study design of subsequent trials or even to a reassessment of the need for further trials.
- 1 November 2006
- Published by Wolters Kluwer Health in Epidemiology
- Vol. 17 (6) , 644-649
Sequential Meta-analysis of Past Clinical Trials to Determine the Use of a New Trial
Background: Clinical trials can be stopped early based on interim analyses or sequential analyses. In principle, sequential analyses can also be used to decide whether enough evidence has been gathered in completed trials to make further trials unnecessary. We demonstrate such an application through a retrospective analysis of clinical trials comparing ventilation methods for the treatment of preterm newborns. Methods: We identified 5 recent trials that compared high-frequency ventilation with conventional mechanical ventilation in the treatment of preterm newborns. Death or chronic lung disease and chronic lung disease in survivors were the primary clinical outcomes of interest. We applied sequential meta-analyses to these 5 studies. Results: After including the first study of the last 5 trials in a sequential meta-analysis, the boundary of "no clinically relevant effect" was crossed for both outcomes (death or chronic lung disease). A sensitivity analysis using a reduction in the size of assumed clinically relevant effect showed the same findings after 2 trials. Conclusions: Sequential meta-analyses showed that a lack of clinically relevant effect had been established after the first of the 5 trials. If such an analysis had been conducted after the first or second of these clinical trials, it might have led to changes in the study design of subsequent trials or even to a reassessment of the need for further trials.
- Open Access
- 20 February 2006
- Published by Springer Nature in Critical Care
- Vol. 10 (1) , R34
Systematic review of determinants of mortality in high frequency oscillatory ventilation in acute respiratory distress syndrome
Introduction: Mechanical ventilation has been shown to cause lung injury and to have a significant impact on mortality in acute respiratory distress syndrome. Theoretically, high frequency oscillatory ventilation seems an ideal lung protective ventilation mode. This review evaluates determinants of mortality during use of high frequency oscillatory ventilation. Methods: PubMed was searched for literature reporting randomized trials and cohort studies of high frequency ventilation in adult patients with acute respiratory distress syndrome. Data on mortality and determinants were extracted for patients treated with high frequency oscillatory ventilation. Linear regression analyses were conducted to produce graphical representations of adjusted effects of determinants of mortality. Results: Cohorts of patients treated with high frequency oscillatory ventilation from two randomized trials and seven observational studies were included. Data from cohorts comparing survivors with non-survivors showed differences in age (42.3 versus 51.2 years), prior time on conventional mechanical ventilation (4.0 versus 6.2 days), APACHE II score (22.4 versus 26.1), pH (7.33 versus 7.26) and oxygenation index (26 versus 34). Each extra day on conventional ventilation was associated with a 20% higher mortality adjusted for age and APACHE II score (relative risk (RR) 1.20, 95% confidence interval (CI) 1.15–1.25). However, this association was confounded by differences in pH (pH adjusted RR 1.03, 95% CI 0.73–1.46). Oxygenation index seemed to have an independent effect on mortality (RR 1.10, 95% CI 0.95–1.28). Conclusion: Prolonged ventilation on conventional mechanical ventilation prior to high frequency oscillatory ventilation was not related to mortality. Oxygenation index was a determinant of mortality independent of other disease severity markers.
- 20 February 2006
- Published by Springer Nature in Critical Care
- Vol. 10 (1) , R34
Open AccessSystematic review of determinants of mortality in high frequency oscillatory ventilation in acute respiratory distress syndrome
Introduction: Mechanical ventilation has been shown to cause lung injury and to have a significant impact on mortality in acute respiratory distress syndrome. Theoretically, high frequency oscillatory ventilation seems an ideal lung protective ventilation mode. This review evaluates determinants of mortality during use of high frequency oscillatory ventilation. Methods: PubMed was searched for literature reporting randomized trials and cohort studies of high frequency ventilation in adult patients with acute respiratory distress syndrome. Data on mortality and determinants were extracted for patients treated with high frequency oscillatory ventilation. Linear regression analyses were conducted to produce graphical representations of adjusted effects of determinants of mortality. Results: Cohorts of patients treated with high frequency oscillatory ventilation from two randomized trials and seven observational studies were included. Data from cohorts comparing survivors with non-survivors showed differences in age (42.3 versus 51.2 years), prior time on conventional mechanical ventilation (4.0 versus 6.2 days), APACHE II score (22.4 versus 26.1), pH (7.33 versus 7.26) and oxygenation index (26 versus 34). Each extra day on conventional ventilation was associated with a 20% higher mortality adjusted for age and APACHE II score (relative risk (RR) 1.20, 95% confidence interval (CI) 1.15–1.25). However, this association was confounded by differences in pH (pH adjusted RR 1.03, 95% CI 0.73–1.46). Oxygenation index seemed to have an independent effect on mortality (RR 1.10, 95% CI 0.95–1.28). Conclusion: Prolonged ventilation on conventional mechanical ventilation prior to high frequency oscillatory ventilation was not related to mortality. Oxygenation index was a determinant of mortality independent of other disease severity markers.
- Open Access
- 21 June 2005
- Published by Springer Nature in Critical Care
- Vol. 9 (4) , R430-9
High frequency oscillatory ventilation compared with conventional mechanical ventilation in adult respiratory distress syndrome: a randomized controlled trial [ISRCTN24242669]
Introduction: To compare the safety and efficacy of high frequency oscillatory ventilation (HFOV) with conventional mechanical ventilation (CV) for early intervention in adult respiratory distress syndrome (ARDS), a multi-centre randomized trial in four intensive care units was conducted. Methods: Patients with ARDS were randomized to receive either HFOV or CV. In both treatment arms a priority was given to maintain lung volume while minimizing peak pressures. CV ventilation strategy was aimed at reducing tidal volumes. In the HFOV group, an open lung strategy was used. Respiratory and circulatory parameters were recorded and clinical outcome was determined at 30 days of follow up. Results: The study was prematurely stopped. Thirty-seven patients received HFOV and 24 patients CV (average APACHE II score 21 and 20, oxygenation index 25 and 18 and duration of mechanical ventilation prior to randomization 2.1 and 1.5 days, respectively). There were no statistically significant differences in survival without supplemental oxygen or on ventilator, mortality, therapy failure, or crossover. Adjustment by a priori defined baseline characteristics showed an odds ratio of 0.80 (95% CI 0.22–2.97) for survival without oxygen or on ventilator, and an odds ratio for mortality of 1.15 (95% CI 0.43–3.10) for HFOV compared with CV. The response of the oxygenation index (OI) to treatment did not differentiate between survival and death. In the HFOV group the OI response was significantly higher than in the CV group between the first and the second day. A post hoc analysis suggested that there was a relatively better treatment effect of HFOV compared with CV in patients with a higher baseline OI. Conclusion: No significant differences were observed, but this trial only had power to detect major differences in survival without oxygen or on ventilator. In patients with ARDS and higher baseline OI, however, there might be a treatment benefit of HFOV over CV. More research is needed to establish the efficacy of HFOV in the treatment of ARDS. We suggest that future studies are designed to allow for informative analysis in patients with higher OI.
- 21 June 2005
- Published by Springer Nature in Critical Care
- Vol. 9 (4) , R430-9
Open AccessHigh frequency oscillatory ventilation compared with conventional mechanical ventilation in adult respiratory distress syndrome: a randomized controlled trial [ISRCTN24242669]
Introduction: To compare the safety and efficacy of high frequency oscillatory ventilation (HFOV) with conventional mechanical ventilation (CV) for early intervention in adult respiratory distress syndrome (ARDS), a multi-centre randomized trial in four intensive care units was conducted. Methods: Patients with ARDS were randomized to receive either HFOV or CV. In both treatment arms a priority was given to maintain lung volume while minimizing peak pressures. CV ventilation strategy was aimed at reducing tidal volumes. In the HFOV group, an open lung strategy was used. Respiratory and circulatory parameters were recorded and clinical outcome was determined at 30 days of follow up. Results: The study was prematurely stopped. Thirty-seven patients received HFOV and 24 patients CV (average APACHE II score 21 and 20, oxygenation index 25 and 18 and duration of mechanical ventilation prior to randomization 2.1 and 1.5 days, respectively). There were no statistically significant differences in survival without supplemental oxygen or on ventilator, mortality, therapy failure, or crossover. Adjustment by a priori defined baseline characteristics showed an odds ratio of 0.80 (95% CI 0.22–2.97) for survival without oxygen or on ventilator, and an odds ratio for mortality of 1.15 (95% CI 0.43–3.10) for HFOV compared with CV. The response of the oxygenation index (OI) to treatment did not differentiate between survival and death. In the HFOV group the OI response was significantly higher than in the CV group between the first and the second day. A post hoc analysis suggested that there was a relatively better treatment effect of HFOV compared with CV in patients with a higher baseline OI. Conclusion: No significant differences were observed, but this trial only had power to detect major differences in survival without oxygen or on ventilator. In patients with ARDS and higher baseline OI, however, there might be a treatment benefit of HFOV over CV. More research is needed to establish the efficacy of HFOV in the treatment of ARDS. We suggest that future studies are designed to allow for informative analysis in patients with higher OI.