Leendert Blankevoort
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leendert Blankevoort has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Gabriëlle Josephine Maria Tuijthof
Department of Orthopedic Surgery, Academic Medical Centre, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
4 shared publications - Cornelis Niek van Dijk
University of Amsterdam
3 shared publications - Gino M. M. J. Kerkhoffs
Orthopaedic Sports and Traumatology, Department of Orthopaedic Surgery, Academic Medical Center Amsterdam, Amsterdam, The Netherlands
3 shared publications - Matthias U. Schafroth
Orthopaedic Research Center Amsterdam, Department of Orthopaedic Surgery of the Academic Medical Center, University of Amsterdam, Amsterdam Movement Sciences, 1100 DE, Amsterdam, The Netherlands
2 shared publications - Alexander Hoorntje
Foundation for Orthopedic Research, Care & Education, Amphia Hospital, Breda; Department of Orthopaedic Surgery and Sports Medicine, Amsterdam Movement Sciences, Amsterdam University Medical Center, Location Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands
1 shared publication - Amir Abbas Zadpoor
Delft University of Technology
1 shared publication
Latest Publications
- Open Access
- 18 July 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 225
A risk assessment model for chronic ankle instability: indications for early surgical treatment? An observational prospective cohort – study protocol
Chronic ankle instability (CAI) is a common result of an ankle sprain. Even though early surgical treatment yields the best results, overall only professional athletes are eligible for acute surgical stabilization. Treating all patients with early surgical stabilization leads to a high amount of unnecessary invasive interventions, as not all patients progress to CAI. If patients at risk of developing CAI can be identified, treatment policies may be applied more effectively and efficiently. The purpose of this study is to develop a risk assessment model to identify patients at risk for CAI that should receive early surgical treatment. In this observational prospective cohort, all patients aged sixteen years and older, reporting at the emergency department of one of the participating hospitals after sustaining a lateral ankle sprain, and filled out 1 out of 3 follow-up questionnaires and the 1 year follow-up are included. A lateral and anteroposterior radiograph is made. Patients are excluded if a fracture or other pathology is present. The included patients receive four questionnaires, including questions focusing on the sprain, treatment and complaints, the Foot and Ankle Outcome Score and the Cumberland Ankle Instability Tool. A total of eleven radiographic variables are assessed for inter- and intra-observer reliability. Additionally, four factors extracted from the questionnaires, will be evaluated for correlation with CAI. Significantly correlating factors (e.a. risk factors) will be implemented in a risk assessment model. For the final model, based on sixteen variables with a minimum of 20 events per variable and a prevalence of 30–40% after an initial sprain, a sample size of 2370 patients is needed to perform both internal and external model validation. This study will develop the first large scale model for the risk at CAI after an ankle sprain combining radiographic and patient characteristics. With this risk assessment model, patients at risk for CAI may be identified and properly informed on the treatment options. Patients identified as being at risk, may receive more adequate follow-up and become eligible for early surgical stabilization. This prevents patients from experiencing unnecessary long-lasting complaints, increasing the success rate of conservative and surgical treatment. Retrospectively registered: NCT02955485 [Registration date: 3–11-2016]. NTR6139 [Registration date: 3–1-2017].
- 18 July 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 225
Open AccessA risk assessment model for chronic ankle instability: indications for early surgical treatment? An observational prospective cohort – study protocol
Chronic ankle instability (CAI) is a common result of an ankle sprain. Even though early surgical treatment yields the best results, overall only professional athletes are eligible for acute surgical stabilization. Treating all patients with early surgical stabilization leads to a high amount of unnecessary invasive interventions, as not all patients progress to CAI. If patients at risk of developing CAI can be identified, treatment policies may be applied more effectively and efficiently. The purpose of this study is to develop a risk assessment model to identify patients at risk for CAI that should receive early surgical treatment. In this observational prospective cohort, all patients aged sixteen years and older, reporting at the emergency department of one of the participating hospitals after sustaining a lateral ankle sprain, and filled out 1 out of 3 follow-up questionnaires and the 1 year follow-up are included. A lateral and anteroposterior radiograph is made. Patients are excluded if a fracture or other pathology is present. The included patients receive four questionnaires, including questions focusing on the sprain, treatment and complaints, the Foot and Ankle Outcome Score and the Cumberland Ankle Instability Tool. A total of eleven radiographic variables are assessed for inter- and intra-observer reliability. Additionally, four factors extracted from the questionnaires, will be evaluated for correlation with CAI. Significantly correlating factors (e.a. risk factors) will be implemented in a risk assessment model. For the final model, based on sixteen variables with a minimum of 20 events per variable and a prevalence of 30–40% after an initial sprain, a sample size of 2370 patients is needed to perform both internal and external model validation. This study will develop the first large scale model for the risk at CAI after an ankle sprain combining radiographic and patient characteristics. With this risk assessment model, patients at risk for CAI may be identified and properly informed on the treatment options. Patients identified as being at risk, may receive more adequate follow-up and become eligible for early surgical stabilization. This prevents patients from experiencing unnecessary long-lasting complaints, increasing the success rate of conservative and surgical treatment. Retrospectively registered: NCT02955485 [Registration date: 3–11-2016]. NTR6139 [Registration date: 3–1-2017].
- Open Access
- 25 September 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 26 (6) , 1751-1758
Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis
Malalignment of implants is a major source of failure during total knee arthroplasty. To achieve more accurate 3D planning and execution of the osteotomy cuts during surgery, the Signature (Biomet, Warsaw) patient-specific instrumentation (PSI) was used to produce pin guides for the positioning of the osteotomy blocks by means of computer-aided manufacture based on CT scan images. The research question of this study is: what is the transfer accuracy of osteotomy planes predicted by the Signature PSI system for preoperative 3D planning and intraoperative block-guided pin placement to perform total knee arthroplasty procedures?
- 25 September 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 26 (6) , 1751-1758
Open AccessPredicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis
Malalignment of implants is a major source of failure during total knee arthroplasty. To achieve more accurate 3D planning and execution of the osteotomy cuts during surgery, the Signature (Biomet, Warsaw) patient-specific instrumentation (PSI) was used to produce pin guides for the positioning of the osteotomy blocks by means of computer-aided manufacture based on CT scan images. The research question of this study is: what is the transfer accuracy of osteotomy planes predicted by the Signature PSI system for preoperative 3D planning and intraoperative block-guided pin placement to perform total knee arthroplasty procedures?
- 1 December 2016
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 24 (12) , 2108-2115
Bone shape difference between control and osteochondral defect groups of the ankle joint
- 1 December 2016
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 24 (12) , 2108-2115
Bone shape difference between control and osteochondral defect groups of the ankle joint
- Open Access
- 2 March 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-9
Does Goal Attainment Scaling improve satisfaction regarding performance of activities of younger knee arthroplasty patients? Study protocol of the randomized controlled ACTION trial
Knee arthroplasty is being increasingly performed, and also more often in a younger patient population (<65 years of age). Up to 20 % of patients remain dissatisfied after knee arthroplasty, despite the apparent technical success of the operation. Recent studies suggest that the fulfilment of patients’ expectations plays an important role in achieving satisfaction. Thus, addressing preoperative expectations more explicitly might improve patient satisfaction. The primary aim of the present study is to investigate the effect of a multidisciplinary, goal attained and individualized rehabilitation on satisfaction of activities of younger patients (<65 years) after knee arthroplasty. A single-centre randomized controlled trial will be conducted. In total, 120 patients (<65 years of age) with knee osteoarthritis who will undergo knee arthroplasty, will be randomly allocated to either goal attainment scaling rehabilitation or usual care rehabilitation. Goal attainment scaling rehabilitation includes drafting individually set rehabilitation goals preoperatively and measuring progress of rehabilitation on a six-point scale (-3 to +2). The primary outcome is patient satisfaction concerning activities in daily life, work and leisure time, including sports. Secondary outcome measures include KOOS, OKS, SQUASH and WORQ questionnaires and activity objectively measured with the Activ8® activity monitor. The findings of this study will help to elucidate whether goal attainment scaling is an effective rehabilitation method for achieving higher levels of patient satisfaction, with a focus on activities, in younger patients after knee arthroplasty. This trial is since June 15th 2015 registered at the Dutch Trial Register: NTR5251 .
- 2 March 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-9
Open AccessDoes Goal Attainment Scaling improve satisfaction regarding performance of activities of younger knee arthroplasty patients? Study protocol of the randomized controlled ACTION trial
Knee arthroplasty is being increasingly performed, and also more often in a younger patient population (<65 years of age). Up to 20 % of patients remain dissatisfied after knee arthroplasty, despite the apparent technical success of the operation. Recent studies suggest that the fulfilment of patients’ expectations plays an important role in achieving satisfaction. Thus, addressing preoperative expectations more explicitly might improve patient satisfaction. The primary aim of the present study is to investigate the effect of a multidisciplinary, goal attained and individualized rehabilitation on satisfaction of activities of younger patients (<65 years) after knee arthroplasty. A single-centre randomized controlled trial will be conducted. In total, 120 patients (<65 years of age) with knee osteoarthritis who will undergo knee arthroplasty, will be randomly allocated to either goal attainment scaling rehabilitation or usual care rehabilitation. Goal attainment scaling rehabilitation includes drafting individually set rehabilitation goals preoperatively and measuring progress of rehabilitation on a six-point scale (-3 to +2). The primary outcome is patient satisfaction concerning activities in daily life, work and leisure time, including sports. Secondary outcome measures include KOOS, OKS, SQUASH and WORQ questionnaires and activity objectively measured with the Activ8® activity monitor. The findings of this study will help to elucidate whether goal attainment scaling is an effective rehabilitation method for achieving higher levels of patient satisfaction, with a focus on activities, in younger patients after knee arthroplasty. This trial is since June 15th 2015 registered at the Dutch Trial Register: NTR5251 .
- Open Access
- 1 January 2015
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 2 (1) , 1-8
Histological characteristics of ligament healing after bio‐enhanced repair of the transected goat ACL
Background: Recently, healing of a ruptured anterior cruciate ligament (ACL) is reconsidered. In a previous study, we have shown that the transected ACL can heal after treatment with the triple X locking suture alone or combined with small intestine submucosa (SIS). The first research question of this study was whether the healing ACLs in both groups show histological characteristics that are typical for ligament healing. Secondly, did the combined treatment with SIS lead to improved histological healing, in terms of the morphology of the fibrous synovial layer, the extracellular matrix (ECM), collagen fiber orientation, cellularity, ratio of myofibroblasts, and collagen type 3 staining. The hypothesis was that SIS enhances the healing by the scaffolding effect, endogenous growth factors, and chemoattractants.Methods: In the Suture group, the left ACL was transected and sutured with the triple X locking suture repair technique. In the Suture‐SIS group, the left ACL underwent the same procedure with the addition of SIS. The right ACL served as internal control. Standard histology and immunostaining of α‐smooth muscle actin (SMA) and collagen type 3 were used.Results: Microscopy showed that the fibrous synovial layer around the ACL was reestablished in both groups. The collagen fibers in the Suture‐SIS group stained denser, were more compactly arranged, and the ECM contained fewer voids and fat vacuoles. Neovasculature running between the collagen fibers was observed in both experimental groups. Collagen type 3 stained less in the Suture‐SIS group. The cellularity in the Suture group, Suture‐SIS group and Control was 1265 ± 1034 per mm2, 954 ± 378 per mm2, 254 ± 92, respectively; 49%, 26% and 20% of the cells stain positive for α‐SMA, respectively.Conclusion: The healing ACL in both treated groups showed histological characteristics which are comparable to the spontaneously healing medial collateral ligament and showed that the ACL has a similar intrinsic healing response. Though, no definitive conclusions on the beneficial effects of the SIS scaffold on the healing process can be made.
- 1 January 2015
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 2 (1) , 1-8
Open AccessHistological characteristics of ligament healing after bio‐enhanced repair of the transected goat ACL
Background: Recently, healing of a ruptured anterior cruciate ligament (ACL) is reconsidered. In a previous study, we have shown that the transected ACL can heal after treatment with the triple X locking suture alone or combined with small intestine submucosa (SIS). The first research question of this study was whether the healing ACLs in both groups show histological characteristics that are typical for ligament healing. Secondly, did the combined treatment with SIS lead to improved histological healing, in terms of the morphology of the fibrous synovial layer, the extracellular matrix (ECM), collagen fiber orientation, cellularity, ratio of myofibroblasts, and collagen type 3 staining. The hypothesis was that SIS enhances the healing by the scaffolding effect, endogenous growth factors, and chemoattractants.Methods: In the Suture group, the left ACL was transected and sutured with the triple X locking suture repair technique. In the Suture‐SIS group, the left ACL underwent the same procedure with the addition of SIS. The right ACL served as internal control. Standard histology and immunostaining of α‐smooth muscle actin (SMA) and collagen type 3 were used.Results: Microscopy showed that the fibrous synovial layer around the ACL was reestablished in both groups. The collagen fibers in the Suture‐SIS group stained denser, were more compactly arranged, and the ECM contained fewer voids and fat vacuoles. Neovasculature running between the collagen fibers was observed in both experimental groups. Collagen type 3 stained less in the Suture‐SIS group. The cellularity in the Suture group, Suture‐SIS group and Control was 1265 ± 1034 per mm2, 954 ± 378 per mm2, 254 ± 92, respectively; 49%, 26% and 20% of the cells stain positive for α‐SMA, respectively.Conclusion: The healing ACL in both treated groups showed histological characteristics which are comparable to the spontaneously healing medial collateral ligament and showed that the ACL has a similar intrinsic healing response. Though, no definitive conclusions on the beneficial effects of the SIS scaffold on the healing process can be made.
- 31 January 2012
- Published by Elsevier in International Journal of Industrial Ergonomics
- Vol. 42 (1) , 41-48
A novel foot plate to assess 3D range of motion of the hindfoot
- 31 January 2012
- Published by Elsevier in International Journal of Industrial Ergonomics
- Vol. 42 (1) , 41-48
A novel foot plate to assess 3D range of motion of the hindfoot
- Open Access
- 3 September 2010
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 19 (2) , 248-254
Probing forces of menisci: what levels are safe for arthroscopic surgery
Purpose: To facilitate effective learning, feedback on performance during arthroscopic training is essential. Less attention has been paid to feedback on monitoring safe handling of delicate tissues such as meniscus. The goal is to measure in vitro probing forces of menisci and compare them with a theoretical maximum probing force (TMPF).Method: Menisci samples of ten cadavers were mounted on force platforms to measure probing forces up to 20 N in three directions. Nineteen subjects participated: six novices (experience 60 arthroscopies), and three faculty (>250 a year). All had to perform three tasks on each meniscus sample with an arthroscopic probe: push three times on the superior meniscal surface, perform one continuous run on the superior meniscal surface, and push three times on the inferior meniscal surface. The absolute maximum probing force (AMPF) was determined for each condition. A multivariable linear regression analysis was performed to assess the influence of experience on the force magnitude (P < 0.05). AMPFs were compared to the TMPF (estimated to be 8.5 N).Results: The AMPF of the push task was on average 2.8 N (standard deviation (SD) of 0.8 N), of the continuous run task 2.5 N (SD 0.9 N), and of the pull task 3.9 N (SD 2.0 N). Significant difference was present between experts and novices (P < 0.05). The AMPFs are in the same order of magnitude as the TMPF.Conclusion: The results indicate the necessity of using a safety level for tissue manipulation when training arthroscopy and a value for is magnitude.
- 3 September 2010
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 19 (2) , 248-254
Open AccessProbing forces of menisci: what levels are safe for arthroscopic surgery
Purpose: To facilitate effective learning, feedback on performance during arthroscopic training is essential. Less attention has been paid to feedback on monitoring safe handling of delicate tissues such as meniscus. The goal is to measure in vitro probing forces of menisci and compare them with a theoretical maximum probing force (TMPF).Method: Menisci samples of ten cadavers were mounted on force platforms to measure probing forces up to 20 N in three directions. Nineteen subjects participated: six novices (experience 60 arthroscopies), and three faculty (>250 a year). All had to perform three tasks on each meniscus sample with an arthroscopic probe: push three times on the superior meniscal surface, perform one continuous run on the superior meniscal surface, and push three times on the inferior meniscal surface. The absolute maximum probing force (AMPF) was determined for each condition. A multivariable linear regression analysis was performed to assess the influence of experience on the force magnitude (P < 0.05). AMPFs were compared to the TMPF (estimated to be 8.5 N).Results: The AMPF of the push task was on average 2.8 N (standard deviation (SD) of 0.8 N), of the continuous run task 2.5 N (SD 0.9 N), and of the pull task 3.9 N (SD 2.0 N). Significant difference was present between experts and novices (P < 0.05). The AMPFs are in the same order of magnitude as the TMPF.Conclusion: The results indicate the necessity of using a safety level for tissue manipulation when training arthroscopy and a value for is magnitude.
- 19 March 2010
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 18 (5) , 618-627
The relation between geometry and function of the ankle joint complex: a biomechanical review
This review deals with the relation between the anatomy and function of the ankle joint complex. The questions addressed are how high do the forces in the ankle joint get, where can the joints go (range of motion) and where do they go during walking and running. Finally the role of the ligaments and the articular surfaces is discussed, i.e. how does it happen. The magnitude of the loads on the ankle joint complex are primarily determined by muscle activity and can be as high as four times the body weight during walking. For the maximal range of motion, plantar and dorsiflexion occurs in the talocrural joint and marginally at the subtalar joint. In‐eversion takes place at both levels. The functional range of motion is well within the limits of the maximal range of motion. The ligaments do not contribute to the forces for the functional range of motion but determine the maximal range of motion together with the articular surfaces. The geometry of the articular surfaces primarily determines the kinematics. Clinical studies must include these anatomical aspects to better understand the mechanism of injury, recovery, and interventions. Models can elucidate the mechanism by which the anatomy relates to the function. The relation between the anatomy and mechanical properties of the joint structures and joint function should be considered for diagnosis and treatment of ankle joint pathology.
- 19 March 2010
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 18 (5) , 618-627
The relation between geometry and function of the ankle joint complex: a biomechanical review
This review deals with the relation between the anatomy and function of the ankle joint complex. The questions addressed are how high do the forces in the ankle joint get, where can the joints go (range of motion) and where do they go during walking and running. Finally the role of the ligaments and the articular surfaces is discussed, i.e. how does it happen. The magnitude of the loads on the ankle joint complex are primarily determined by muscle activity and can be as high as four times the body weight during walking. For the maximal range of motion, plantar and dorsiflexion occurs in the talocrural joint and marginally at the subtalar joint. In‐eversion takes place at both levels. The functional range of motion is well within the limits of the maximal range of motion. The ligaments do not contribute to the forces for the functional range of motion but determine the maximal range of motion together with the articular surfaces. The geometry of the articular surfaces primarily determines the kinematics. Clinical studies must include these anatomical aspects to better understand the mechanism of injury, recovery, and interventions. Models can elucidate the mechanism by which the anatomy relates to the function. The relation between the anatomy and mechanical properties of the joint structures and joint function should be considered for diagnosis and treatment of ankle joint pathology.
- 1 June 2009
- Published by ASME International in Journal of Medical Devices
- Vol. 3 (2) , 021003
Arthroscopic Sheath Design and Technical Evaluation
The maintenance of a clear view on the operation area is essential to perform a minimally invasive procedure. In arthroscopy, this is achieved by irrigating the joint with a saline fluid that is pumped through the joint. At present, the arthroscopic sheaths are not designed for optimal irrigation, which causes suboptimal arthroscopic view. The goal of this study is to present new design concepts and their technical evaluation to optimize irrigation. We focused on decreasing the fluid restriction and stimulating turbulent inflow streams. This is achieved by combining analysis of clinical practice, fluid mechanics theory, and experiments. A distinction is made between a three- and a two-portal technique. For a three-portal technique, the design concept consisted of a conventional sheath used with a smaller diameter arthroscope . This resulted in a decreased fluid restriction. For the two-portal technique, a partition is designed, which separates the inflow and outflow streams in this sheath. Practical embodiments of the concepts are evaluated experimentally, in comparison with conventional sheaths. The setup consisted of a simulated arthroscopic operative setting of a knee joint. The main discriminating measures are the irrigation time, the fluid restriction, the flow, and the pressure in the joint. The results show that the proposed concept for the three-portal technique decreased the irrigation time significantly by 25%, and the concept with the partition for the two-portal technique decreased the irrigation time by 67% (analysis of variance, ). Different sheath tips showed no significant differences, leaving the straight shaft as the preferred embodiment. The simulation environment proved to be a suitable platform to test devices in a conditioned setting. The new sheath is expected to be a valuable improvement in achieving optimal irrigation.- 1 June 2009
- Published by ASME International in Journal of Medical Devices
- Vol. 3 (2) , 021003
Arthroscopic Sheath Design and Technical Evaluation
The maintenance of a clear view on the operation area is essential to perform a minimally invasive procedure. In arthroscopy, this is achieved by irrigating the joint with a saline fluid that is pumped through the joint. At present, the arthroscopic sheaths are not designed for optimal irrigation, which causes suboptimal arthroscopic view. The goal of this study is to present new design concepts and their technical evaluation to optimize irrigation. We focused on decreasing the fluid restriction and stimulating turbulent inflow streams. This is achieved by combining analysis of clinical practice, fluid mechanics theory, and experiments. A distinction is made between a three- and a two-portal technique. For a three-portal technique, the design concept consisted of a conventional sheath used with a smaller diameter arthroscope . This resulted in a decreased fluid restriction. For the two-portal technique, a partition is designed, which separates the inflow and outflow streams in this sheath. Practical embodiments of the concepts are evaluated experimentally, in comparison with conventional sheaths. The setup consisted of a simulated arthroscopic operative setting of a knee joint. The main discriminating measures are the irrigation time, the fluid restriction, the flow, and the pressure in the joint. The results show that the proposed concept for the three-portal technique decreased the irrigation time significantly by 25%, and the concept with the partition for the two-portal technique decreased the irrigation time by 67% (analysis of variance, ). Different sheath tips showed no significant differences, leaving the straight shaft as the preferred embodiment. The simulation environment proved to be a suitable platform to test devices in a conditioned setting. The new sheath is expected to be a valuable improvement in achieving optimal irrigation.- 27 May 2009
- Published by ASME International in Journal of Medical Devices
- Vol. 3 (2) , 021001
Physical Simulation Environment for Arthroscopic Joint Irrigation
Good arthroscopic view is important to perform arthroscopic operations (minimally invasive surgery in joints) safely and fast. To obtain this, the joint is irrigated. However, optimal irrigation settings are not described. To study the complex clinical practice of irrigation, a physical simulation environment was developed that incorporates the main characteristics for performing arthroscopy. Its irrigation capacities were validated with patient data. The physical simulation environment consists of a specially designed knee phantom, all normally used arthroscopic equipment, and registration devices for two video streams, pressures, and flows. The physical embodiment of the knee phantom matches that of human knee joints during arthroscopic operations by the presence of important anatomic structures in sizes comparable to human knee joints, the presence of access portals, and the ability to stress the joint. The hydrostatic and hydrodynamic behavior of the knee phantom was validated with pressure and flow measurements documented during arthroscopic knee operations. Surgeons confirmed that the knee phantom imitated human knee joints sufficiently. The hydrostatic parameters of the knee phantom could be tuned within the range of the human knee joints (restriction: versus and capacitance: versus ). The hydrodynamic properties of the knee phantom were acceptably comparable to those of the human knee joints. The physical simulation environment enables realistic and conditioned experimental studies to optimize joint irrigation. The foundation has been laid for evaluation of other surgical instruments and of training of surgical skills.- 27 May 2009
- Published by ASME International in Journal of Medical Devices
- Vol. 3 (2) , 021001
Physical Simulation Environment for Arthroscopic Joint Irrigation
Good arthroscopic view is important to perform arthroscopic operations (minimally invasive surgery in joints) safely and fast. To obtain this, the joint is irrigated. However, optimal irrigation settings are not described. To study the complex clinical practice of irrigation, a physical simulation environment was developed that incorporates the main characteristics for performing arthroscopy. Its irrigation capacities were validated with patient data. The physical simulation environment consists of a specially designed knee phantom, all normally used arthroscopic equipment, and registration devices for two video streams, pressures, and flows. The physical embodiment of the knee phantom matches that of human knee joints during arthroscopic operations by the presence of important anatomic structures in sizes comparable to human knee joints, the presence of access portals, and the ability to stress the joint. The hydrostatic and hydrodynamic behavior of the knee phantom was validated with pressure and flow measurements documented during arthroscopic knee operations. Surgeons confirmed that the knee phantom imitated human knee joints sufficiently. The hydrostatic parameters of the knee phantom could be tuned within the range of the human knee joints (restriction: versus and capacitance: versus ). The hydrodynamic properties of the knee phantom were acceptably comparable to those of the human knee joints. The physical simulation environment enables realistic and conditioned experimental studies to optimize joint irrigation. The foundation has been laid for evaluation of other surgical instruments and of training of surgical skills.