Marinette van der Graaf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marinette van der Graaf has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Arend Heerschap
Department of Radiology, 667, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
3 shared publicationsCees J. Tack
Department of General Internal Medicine, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands
2 shared publicationsJacco H. de Haan
Department of Radiology, 667, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
2 shared publicationsAlexandra H. Mulder
Department of General Internal Medicine, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands
1 shared publicationAngel Moreno‐Torres
Centre Diagnòstic Pedralbes, Barcelona, Spain
1 shared publicationAnne Ziegler
INSERM U594/Université Joseph Fourier ‘Neuroimagerie fonctionnelle et métabolique’, Laboratoire de Recherche Conventionné (30V) du CEA, Centre Hospitalier Universitaire, Grenoble, France
1 shared publication
Latest Publications
- Open Access
- 24 September 2010
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 111 (2) , 275-283
The effect of acute exercise on glycogen synthesis rate in obese subjects studied by 13C MRS
In obesity, insulin-stimulated glucose uptake in skeletal muscle is decreased. We investigated whether the stimulatory effect of acute exercise on glucose uptake and subsequent glycogen synthesis was normal. The study was performed on 18 healthy volunteers, 9 obese (BMI = 32.6 ± 1.2 kg/m2, mean ± SEM) and 9 lean (BMI = 22.0 ± 0.9 kg/m2), matched for age and gender. All participants underwent a euglycemic hyperinsulinemic clamp, showing reduced glucose uptake in the obese group (P = 0.01), during which they performed a short intense local exercise (single-legged toe lifting). Dynamic glucose incorporation into glycogen in the gastrocnemius muscle before and after exercise was assessed by 13C magnetic resonance spectroscopy combined with infusion of [1-13C]glucose. Blood flow was measured to investigate its potential contribution to glucose uptake. Before exercise, glycogen synthesis rate tended to be lower in obese subjects compared with lean (78 ± 14 vs. 132 ± 24 μmol/kg muscle/min; P = 0.07). Exercise induced highly significant rises in glycogen synthesis rates in both groups, but the increase in obese subjects was reduced compared with lean (112 ± 15 vs. 186 ± 27 μmol/kg muscle/min; P = 0.03), although the relative increase was similar (184 ± 35 vs. 202 ± 51%; P = 0.78). After exercise, blood flow increased equally in both groups, without a temporal relationship with the rate of glycogen synthesis. In conclusion, this study shows a stimulatory effect of a short bout of acute exercise on insulin-induced glycogen synthesis rate that is reduced in absolute values but similar in percentages in obese subjects. These results suggest a shared pathway between insulin- and exercise-induced glucose uptake and subsequent glycogen synthesis.
- 24 September 2010
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 111 (2) , 275-283
Open AccessThe effect of acute exercise on glycogen synthesis rate in obese subjects studied by 13C MRS
In obesity, insulin-stimulated glucose uptake in skeletal muscle is decreased. We investigated whether the stimulatory effect of acute exercise on glucose uptake and subsequent glycogen synthesis was normal. The study was performed on 18 healthy volunteers, 9 obese (BMI = 32.6 ± 1.2 kg/m2, mean ± SEM) and 9 lean (BMI = 22.0 ± 0.9 kg/m2), matched for age and gender. All participants underwent a euglycemic hyperinsulinemic clamp, showing reduced glucose uptake in the obese group (P = 0.01), during which they performed a short intense local exercise (single-legged toe lifting). Dynamic glucose incorporation into glycogen in the gastrocnemius muscle before and after exercise was assessed by 13C magnetic resonance spectroscopy combined with infusion of [1-13C]glucose. Blood flow was measured to investigate its potential contribution to glucose uptake. Before exercise, glycogen synthesis rate tended to be lower in obese subjects compared with lean (78 ± 14 vs. 132 ± 24 μmol/kg muscle/min; P = 0.07). Exercise induced highly significant rises in glycogen synthesis rates in both groups, but the increase in obese subjects was reduced compared with lean (112 ± 15 vs. 186 ± 27 μmol/kg muscle/min; P = 0.03), although the relative increase was similar (184 ± 35 vs. 202 ± 51%; P = 0.78). After exercise, blood flow increased equally in both groups, without a temporal relationship with the rate of glycogen synthesis. In conclusion, this study shows a stimulatory effect of a short bout of acute exercise on insulin-induced glycogen synthesis rate that is reduced in absolute values but similar in percentages in obese subjects. These results suggest a shared pathway between insulin- and exercise-induced glucose uptake and subsequent glycogen synthesis.
- 8 September 2009
- Published by Wiley in NMR in Biomedicine
- Vol. 23 (2) , 133-141
Magnetic resonance spectroscopy shows an inverse correlation between intramyocellular lipid content in human calf muscle and local glycogen synthesis rate
Intramyocellular lipid (IMCL) content of skeletal muscle, as measured with 1H MRS, is inversely correlated with insulin sensitivity as determined by whole body glucose uptake. The latter, however, does not necessarily represent the actual glucose uptake in the corresponding skeletal muscle. In this study, we examined whether IMCL content in human calf muscle correlated with local glucose uptake assessed by measurement of glycogen synthesis rate within the same muscle compartment. We studied 20 subjects belonging to four subgroups of five persons each: young lean, elderly lean, young obese and elderly obese. IMCL content in the soleus and gastrocnemius muscle was determined using 1H MR spectroscopic imaging and local glycogen synthesis rate in the calf muscle was measured by 13C MRS during a euglycaemic hyperinsulinaemic clamp with 20% w/v 30% 13C‐1‐labelled glucose infusion. Significantly higher IMCL contents were found in elderly (soleus: p < 0.0001 and gastrocnemius: p < 0.01) and obese subjects (p < 0.01 for both muscles). Local glycogen synthesis rate decreased significantly with obesity (p < 0.01). The principal finding of this study was that the mean IMCL content of the soleus and gastrocnemius muscles was indeed inversely correlated with the local glycogen synthesis rate in the calf muscle (rs = −0.50, p < 0.05), with a very similar dependency as the inverse correlation between mean IMCL content and total body glucose uptake (rs = −0.54, p < 0.05). We conclude that IMCL content of the soleus and gastrocnemius muscles reflects a measure for local insulin resistance within the same muscle compartment as determined by glycogen synthesis rate. Although the inverse correlation suggests that insulin sensitivity is affected by the local amount of fat present, it remains to be determined if this is a cause or a consequence. Copyright © 2009 John Wiley & Sons, Ltd.
- 8 September 2009
- Published by Wiley in NMR in Biomedicine
- Vol. 23 (2) , 133-141
Magnetic resonance spectroscopy shows an inverse correlation between intramyocellular lipid content in human calf muscle and local glycogen synthesis rate
Intramyocellular lipid (IMCL) content of skeletal muscle, as measured with 1H MRS, is inversely correlated with insulin sensitivity as determined by whole body glucose uptake. The latter, however, does not necessarily represent the actual glucose uptake in the corresponding skeletal muscle. In this study, we examined whether IMCL content in human calf muscle correlated with local glucose uptake assessed by measurement of glycogen synthesis rate within the same muscle compartment. We studied 20 subjects belonging to four subgroups of five persons each: young lean, elderly lean, young obese and elderly obese. IMCL content in the soleus and gastrocnemius muscle was determined using 1H MR spectroscopic imaging and local glycogen synthesis rate in the calf muscle was measured by 13C MRS during a euglycaemic hyperinsulinaemic clamp with 20% w/v 30% 13C‐1‐labelled glucose infusion. Significantly higher IMCL contents were found in elderly (soleus: p < 0.0001 and gastrocnemius: p < 0.01) and obese subjects (p < 0.01 for both muscles). Local glycogen synthesis rate decreased significantly with obesity (p < 0.01). The principal finding of this study was that the mean IMCL content of the soleus and gastrocnemius muscles was indeed inversely correlated with the local glycogen synthesis rate in the calf muscle (rs = −0.50, p < 0.05), with a very similar dependency as the inverse correlation between mean IMCL content and total body glucose uptake (rs = −0.54, p < 0.05). We conclude that IMCL content of the soleus and gastrocnemius muscles reflects a measure for local insulin resistance within the same muscle compartment as determined by glycogen synthesis rate. Although the inverse correlation suggests that insulin sensitivity is affected by the local amount of fat present, it remains to be determined if this is a cause or a consequence. Copyright © 2009 John Wiley & Sons, Ltd.
- Open Access
- 13 August 2009
- Published by Springer Nature in European Biophysics Journal
- Vol. 39 (4) , 527-540
In vivo magnetic resonance spectroscopy: basic methodology and clinical applications
The clinical use of in vivo magnetic resonance spectroscopy (MRS) has been limited for a long time, mainly due to its low sensitivity. However, with the advent of clinical MR systems with higher magnetic field strengths such as 3 Tesla, the development of better coils, and the design of optimized radio-frequency pulses, sensitivity has been considerably improved. Therefore, in vivo MRS has become a technique that is routinely used more and more in the clinic. In this review, the basic methodology of in vivo MRS is described—mainly focused on 1H MRS of the brain—with attention to hardware requirements, patient safety, acquisition methods, data post-processing, and quantification. Furthermore, examples of clinical applications of in vivo brain MRS in two interesting fields are described. First, together with a description of the major resonances present in brain MR spectra, several examples are presented of deviations from the normal spectral pattern associated with inborn errors of metabolism. Second, through examples of MR spectra of brain tumors, it is shown that MRS can play an important role in oncology.
- 13 August 2009
- Published by Springer Nature in European Biophysics Journal
- Vol. 39 (4) , 527-540
Open AccessIn vivo magnetic resonance spectroscopy: basic methodology and clinical applications
The clinical use of in vivo magnetic resonance spectroscopy (MRS) has been limited for a long time, mainly due to its low sensitivity. However, with the advent of clinical MR systems with higher magnetic field strengths such as 3 Tesla, the development of better coils, and the design of optimized radio-frequency pulses, sensitivity has been considerably improved. Therefore, in vivo MRS has become a technique that is routinely used more and more in the clinic. In this review, the basic methodology of in vivo MRS is described—mainly focused on 1H MRS of the brain—with attention to hardware requirements, patient safety, acquisition methods, data post-processing, and quantification. Furthermore, examples of clinical applications of in vivo brain MRS in two interesting fields are described. First, together with a description of the major resonances present in brain MR spectra, several examples are presented of deviations from the normal spectral pattern associated with inborn errors of metabolism. Second, through examples of MR spectra of brain tumors, it is shown that MRS can play an important role in oncology.
- 31 January 2008
- Published by Wiley in NMR in Biomedicine
- Vol. 21 (2) , 148-158
MRS quality assessment in a multicentre study on MRS‐based classification of brain tumours
This paper reports on quality assessment of MRS in the European Union‐funded multicentre project INTERPRET (International Network for Pattern Recognition of Tumours Using Magnetic Resonance; http://azizu.uab.es/INTERPRET), which has developed brain tumour classification software using in vivo proton MR spectra. The quality assessment consisted of both MR system quality assurance (SQA) and quality control (QC) of spectral data acquired from patients and healthy volunteers. The system performance of the MR spectrometers at all participating centres was checked bimonthly by a short measurement protocol using a specially designed INTERPRET phantom. In addition, a more extended SQA protocol was performed yearly and after each hardware or software upgrade. To compare the system performance for in vivo measurements, each centre acquired MR spectra from the brain of five healthy volunteers. All MR systems fulfilled generally accepted minimal system performance for brain MRS during the entire data acquisition period. The QC procedure of the MR spectra in the database comprised automatic determination of the signal‐to‐noise ratio (SNR) in a water‐suppressed spectrum and of the line width of the water resonance (water band width, WBW) in the corresponding non‐suppressed spectrum. Values of SNR > 10 and WBW < 8 Hz at 1.5 T were determined empirically as conservative threshold levels required for spectra to be of acceptable quality. These thresholds only hold for SNR and WBW values using the definitions and data processing described in this article. A final QC check consisted of visual inspection of each clinically validated water‐suppressed metabolite spectrum by two, or, in the case of disagreement, three, experienced MR spectroscopists, to detect artefacts such as large baseline distortions, exceptionally broadened metabolite peaks, insufficient removal of the water line, large phase errors, and signals originating from outside the voxel. In the end, 10% of 889 spectra with completed spectroscopic judgement were discarded. Copyright © 2007 John Wiley & Sons, Ltd.
- 31 January 2008
- Published by Wiley in NMR in Biomedicine
- Vol. 21 (2) , 148-158
MRS quality assessment in a multicentre study on MRS‐based classification of brain tumours
This paper reports on quality assessment of MRS in the European Union‐funded multicentre project INTERPRET (International Network for Pattern Recognition of Tumours Using Magnetic Resonance; http://azizu.uab.es/INTERPRET), which has developed brain tumour classification software using in vivo proton MR spectra. The quality assessment consisted of both MR system quality assurance (SQA) and quality control (QC) of spectral data acquired from patients and healthy volunteers. The system performance of the MR spectrometers at all participating centres was checked bimonthly by a short measurement protocol using a specially designed INTERPRET phantom. In addition, a more extended SQA protocol was performed yearly and after each hardware or software upgrade. To compare the system performance for in vivo measurements, each centre acquired MR spectra from the brain of five healthy volunteers. All MR systems fulfilled generally accepted minimal system performance for brain MRS during the entire data acquisition period. The QC procedure of the MR spectra in the database comprised automatic determination of the signal‐to‐noise ratio (SNR) in a water‐suppressed spectrum and of the line width of the water resonance (water band width, WBW) in the corresponding non‐suppressed spectrum. Values of SNR > 10 and WBW < 8 Hz at 1.5 T were determined empirically as conservative threshold levels required for spectra to be of acceptable quality. These thresholds only hold for SNR and WBW values using the definitions and data processing described in this article. A final QC check consisted of visual inspection of each clinically validated water‐suppressed metabolite spectrum by two, or, in the case of disagreement, three, experienced MR spectroscopists, to detect artefacts such as large baseline distortions, exceptionally broadened metabolite peaks, insufficient removal of the water line, large phase errors, and signals originating from outside the voxel. In the end, 10% of 889 spectra with completed spectroscopic judgement were discarded. Copyright © 2007 John Wiley & Sons, Ltd.
- 1 April 2004
- Vol. 25 (4) , 649-657
MR Imaging and Proton MR Spectroscopic Studies in Sjögren-Larsson Syndrome: Characterization of the Leukoencephalopathy
BACKGROUND AND PURPOSE: Sjögren-Larsson syndrome (SLS) is a neurocutaneous syndrome caused by a genetic enzyme deficiency in lipid metabolism. Our purpose was to characterize the nature of the cerebral involvement in SLS.
- 1 April 2004
- Vol. 25 (4) , 649-657
MR Imaging and Proton MR Spectroscopic Studies in Sjögren-Larsson Syndrome: Characterization of the Leukoencephalopathy
BACKGROUND AND PURPOSE: Sjögren-Larsson syndrome (SLS) is a neurocutaneous syndrome caused by a genetic enzyme deficiency in lipid metabolism. Our purpose was to characterize the nature of the cerebral involvement in SLS.