Andrew T. Sabin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew T. Sabin has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Beverly A. Wright
Department of Communication Sciences and Disorders and Knowles Hearing Center, Northwestern University, 2240 Campus Drive, Evanston, Illinois 60208, USA
4 shared publications - David A. Eddins
School of Communication Sciences and Disorders, University of Central Florida, Orlando
4 shared publications Beverly A. Wright
Department of Communication Sciences and Disorders, Northwestern University, Evanston, IL 60208
2 shared publications- Cynthia A. Clark
Northwestern University
2 shared publications David A. Eddins
Department of Communication Sciences and Disorders, University of South Florida, Tampa, FL 33620
2 shared publicationsNicole Marrone
2 shared publications
Latest Publications
- 1 December 2013
- Published by Elsevier in Hearing Research
- Vol. 306, 76-92
Vertical-plane sound localization with distorted spectral cues
- 1 December 2013
- Published by Elsevier in Hearing Research
- Vol. 306, 76-92
Vertical-plane sound localization with distorted spectral cues
- 1 September 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (3) , 2136-2147
Acoustical correlates of performance on a dynamic range compression discrimination task
Dynamic range compression is widely used to reduce the difference between the most and least intense portions of a signal. Such compression distorts the shape of the amplitude envelope of a signal, but it is unclear to what extent such distortions are actually perceivable by listeners. Here, the ability to distinguish between compressed and uncompressed versions of a noise vocoded sentence was initially measured in listeners with normal hearing while varying the threshold, ratio, attack, and release parameters. This narrow condition was selected in order to characterize perception under the most favorable listening conditions. The average behavioral sensitivity to compression was highly correlated to several acoustical indices of modulation depth. In particular, performance was highly correlated to the Euclidean distance between the modulation spectra of the uncompressed and compressed signals. Suggesting that this relationship is not restricted to the initial test conditions, the correlation remained largely unchanged both (1) when listeners with normal hearing were tested using a time-compressed version of the original signal, and (2) when listeners with impaired hearing were tested using the original signal. If this relationship generalizes to more ecologically valid conditions, it will provide a straightforward method for predicting the detectability of compression-induced distortions.
- 1 September 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 134 (3) , 2136-2147
Acoustical correlates of performance on a dynamic range compression discrimination task
Dynamic range compression is widely used to reduce the difference between the most and least intense portions of a signal. Such compression distorts the shape of the amplitude envelope of a signal, but it is unclear to what extent such distortions are actually perceivable by listeners. Here, the ability to distinguish between compressed and uncompressed versions of a noise vocoded sentence was initially measured in listeners with normal hearing while varying the threshold, ratio, attack, and release parameters. This narrow condition was selected in order to characterize perception under the most favorable listening conditions. The average behavioral sensitivity to compression was highly correlated to several acoustical indices of modulation depth. In particular, performance was highly correlated to the Euclidean distance between the modulation spectra of the uncompressed and compressed signals. Suggesting that this relationship is not restricted to the initial test conditions, the correlation remained largely unchanged both (1) when listeners with normal hearing were tested using a time-compressed version of the original signal, and (2) when listeners with impaired hearing were tested using the original signal. If this relationship generalizes to more ecologically valid conditions, it will provide a straightforward method for predicting the detectability of compression-induced distortions.
- Open Access
- 1 June 2013
- Published by SAGE Publications in Trends in Amplification
- Vol. 17 (2) , 94-107
Initial Development of a Temporal-Envelope-Preserving Nonlinear Hearing Aid Prescription Using a Genetic Algorithm
Most hearing aid prescriptions focus on the optimization of a metric derived from the long-term average spectrum of speech, and do not consider how the prescribed values might distort the temporal envelope shape. A growing body of evidence suggests that such distortions can lead to systematic errors in speech perception, and therefore hearing aid prescriptions might benefit by including preservation of the temporal envelope shape in their rationale. To begin to explore this possibility, we designed a genetic algorithm (GA) to find the multiband compression settings that preserve the shape of the original temporal envelope while placing that envelope in the listener’s audiometric dynamic range. The resulting prescription had a low compression threshold, short attack and release times, and a combination of compression ratio and gain that placed the output signal within the listener’s audiometric dynamic range. Initial behavioral tests of individuals with impaired hearing revealed no difference in speech-in-noise perception between the GA and the NAL-NL2 prescription. However, gap detection performance was superior with the GA in comparison to NAL-NL2. Overall, this work is a proof of concept that consideration of temporal envelope distortions can be incorporated into hearing aid prescriptions.
- 1 June 2013
- Published by SAGE Publications in Trends in Amplification
- Vol. 17 (2) , 94-107
Open AccessInitial Development of a Temporal-Envelope-Preserving Nonlinear Hearing Aid Prescription Using a Genetic Algorithm
Most hearing aid prescriptions focus on the optimization of a metric derived from the long-term average spectrum of speech, and do not consider how the prescribed values might distort the temporal envelope shape. A growing body of evidence suggests that such distortions can lead to systematic errors in speech perception, and therefore hearing aid prescriptions might benefit by including preservation of the temporal envelope shape in their rationale. To begin to explore this possibility, we designed a genetic algorithm (GA) to find the multiband compression settings that preserve the shape of the original temporal envelope while placing that envelope in the listener’s audiometric dynamic range. The resulting prescription had a low compression threshold, short attack and release times, and a combination of compression ratio and gain that placed the output signal within the listener’s audiometric dynamic range. Initial behavioral tests of individuals with impaired hearing revealed no difference in speech-in-noise perception between the GA and the NAL-NL2 prescription. However, gap detection performance was superior with the GA in comparison to NAL-NL2. Overall, this work is a proof of concept that consideration of temporal envelope distortions can be incorporated into hearing aid prescriptions.
- 11 December 2012
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 14 (2) , 283-294
Different Patterns of Perceptual Learning on Spectral Modulation Detection Between Older Hearing-Impaired and Younger Normal-Hearing Adults
Young adults with normal hearing (YNH) can improve their sensitivity to basic acoustic features with practice. However, it is not known to what extent the influence of the same training regimen differs between YNH listeners and older listeners with hearing impairment (OHI)—the largest population seeking treatment in audiology clinics. To examine this issue, we trained OHI listeners on a basic auditory task (spectral modulation detection) using a training regimen previously administered to YNH listeners (∼1 h/session for seven sessions on a single condition). For the trained conditions on which pretraining performance was not already at asymptote, the YNH listeners who received training learned more than matched controls who received none, but that learning did not generalize to any untrained spectral modulation frequency. In contrast, the OHI-trained listeners and controls learned similar amounts on the trained condition, implying no effect of the training itself. However, surprisingly the OHI-trained listeners improved over the training phase and on an untrained spectral modulation frequency. These population differences suggest that learning consolidated more slowly, and that training modified an aspect of processing that had broader tuning to spectral modulation frequency, in OHI than YNH listeners. More generally, these results demonstrate that conclusions about perceptual learning that come from examination of one population do not necessarily apply to another.
- 11 December 2012
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 14 (2) , 283-294
Different Patterns of Perceptual Learning on Spectral Modulation Detection Between Older Hearing-Impaired and Younger Normal-Hearing Adults
Young adults with normal hearing (YNH) can improve their sensitivity to basic acoustic features with practice. However, it is not known to what extent the influence of the same training regimen differs between YNH listeners and older listeners with hearing impairment (OHI)—the largest population seeking treatment in audiology clinics. To examine this issue, we trained OHI listeners on a basic auditory task (spectral modulation detection) using a training regimen previously administered to YNH listeners (∼1 h/session for seven sessions on a single condition). For the trained conditions on which pretraining performance was not already at asymptote, the YNH listeners who received training learned more than matched controls who received none, but that learning did not generalize to any untrained spectral modulation frequency. In contrast, the OHI-trained listeners and controls learned similar amounts on the trained condition, implying no effect of the training itself. However, surprisingly the OHI-trained listeners improved over the training phase and on an untrained spectral modulation frequency. These population differences suggest that learning consolidated more slowly, and that training modified an aspect of processing that had broader tuning to spectral modulation frequency, in OHI than YNH listeners. More generally, these results demonstrate that conclusions about perceptual learning that come from examination of one population do not necessarily apply to another.
- Open Access
- 9 May 2012
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 32 (19) , 6542-6549
Perceptual Learning Evidence for Tuning to Spectrotemporal Modulation in the Human Auditory System
Natural sounds are characterized by complex patterns of sound intensity distributed across both frequency (spectral modulation) and time (temporal modulation). Perception of these patterns has been proposed to depend on a bank of modulation filters, each tuned to a unique combination of a spectral and a temporal modulation frequency. There is considerable physiological evidence for such combined spectrotemporal tuning. However, direct behavioral evidence is lacking. Here we examined the processing of spectrotemporal modulation behaviorally using a perceptual-learning paradigm. We trained human listeners for ∼1 h/d for 7 d to discriminate the depth of spectral (0.5 cyc/oct; 0 Hz), temporal (0 cyc/oct; 32 Hz), or upward spectrotemporal (0.5 cyc/oct; 32 Hz) modulation. Each trained group learned more on their respective trained condition than did controls who received no training. Critically, this depth-discrimination learning did not generalize to the trained stimuli of the other groups or to downward spectrotemporal (0.5 cyc/oct; −32 Hz) modulation. Learning on discrimination also led to worsening on modulation detection, but only when the same spectrotemporal modulation was used for both tasks. Thus, these influences of training were specific to the trained combination of spectral and temporal modulation frequencies, even when the trained and untrained stimuli had one modulation frequency in common. This specificity indicates that training modified circuitry that had combined spectrotemporal tuning, and therefore that circuits with such tuning can influence perception. These results are consistent with the possibility that the auditory system analyzes sounds through filters tuned to combined spectrotemporal modulation.
- 9 May 2012
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 32 (19) , 6542-6549
Open AccessPerceptual Learning Evidence for Tuning to Spectrotemporal Modulation in the Human Auditory System
Natural sounds are characterized by complex patterns of sound intensity distributed across both frequency (spectral modulation) and time (temporal modulation). Perception of these patterns has been proposed to depend on a bank of modulation filters, each tuned to a unique combination of a spectral and a temporal modulation frequency. There is considerable physiological evidence for such combined spectrotemporal tuning. However, direct behavioral evidence is lacking. Here we examined the processing of spectrotemporal modulation behaviorally using a perceptual-learning paradigm. We trained human listeners for ∼1 h/d for 7 d to discriminate the depth of spectral (0.5 cyc/oct; 0 Hz), temporal (0 cyc/oct; 32 Hz), or upward spectrotemporal (0.5 cyc/oct; 32 Hz) modulation. Each trained group learned more on their respective trained condition than did controls who received no training. Critically, this depth-discrimination learning did not generalize to the trained stimuli of the other groups or to downward spectrotemporal (0.5 cyc/oct; −32 Hz) modulation. Learning on discrimination also led to worsening on modulation detection, but only when the same spectrotemporal modulation was used for both tasks. Thus, these influences of training were specific to the trained combination of spectral and temporal modulation frequencies, even when the trained and untrained stimuli had one modulation frequency in common. This specificity indicates that training modified circuitry that had combined spectrotemporal tuning, and therefore that circuits with such tuning can influence perception. These results are consistent with the possibility that the auditory system analyzes sounds through filters tuned to combined spectrotemporal modulation.
- 15 March 2012
- Published by Springer Nature in Experimental Brain Research
- Vol. 218 (4) , 567-577
Perceptual learning of auditory spectral modulation detection
Normal sensory perception requires the ability to detect and identify patterns of activity distributed across the receptor surface. In the visual system, the ability to perceive these patterns across the retina improves with training. This learning differs in magnitude for different trained stimuli and does not generalize to untrained spatial frequencies or retinal locations. Here, we asked whether training to detect patterns of activity across the cochlea yields learning with similar characteristics. Differences in learning between the visual and auditory systems would be inconsistent with the suggestion that the ability to detect these patterns is limited by similar constraints in these two systems. We trained three groups of normal-hearing listeners to detect spectral envelopes with a sinusoidal shape (spectral modulation) at 0.5, 1, or 2 cycles/octave and compared the performance of each group to that of a separate group that received no training. On average, as the trained spectral modulation frequency increased, the magnitude of training-induced improvement and the time to reach asymptotic performance decreased, while the tendency for performance to worsen within a training session increased. The training-induced improvements did not generalize to untrained spectral modulation frequencies or untrained carrier spectra. Thus, for both visual-spatial and auditory spectral modulation detection, learning depended upon and was specific to analogous features of the trained stimulus. Such similarities in learning could arise if, as has been suggested, similar constraints limit the ability to detect patterns across the receptor surface between the auditory and visual systems.
- 15 March 2012
- Published by Springer Nature in Experimental Brain Research
- Vol. 218 (4) , 567-577
Perceptual learning of auditory spectral modulation detection
Normal sensory perception requires the ability to detect and identify patterns of activity distributed across the receptor surface. In the visual system, the ability to perceive these patterns across the retina improves with training. This learning differs in magnitude for different trained stimuli and does not generalize to untrained spatial frequencies or retinal locations. Here, we asked whether training to detect patterns of activity across the cochlea yields learning with similar characteristics. Differences in learning between the visual and auditory systems would be inconsistent with the suggestion that the ability to detect these patterns is limited by similar constraints in these two systems. We trained three groups of normal-hearing listeners to detect spectral envelopes with a sinusoidal shape (spectral modulation) at 0.5, 1, or 2 cycles/octave and compared the performance of each group to that of a separate group that received no training. On average, as the trained spectral modulation frequency increased, the magnitude of training-induced improvement and the time to reach asymptotic performance decreased, while the tendency for performance to worsen within a training session increased. The training-induced improvements did not generalize to untrained spectral modulation frequencies or untrained carrier spectra. Thus, for both visual-spatial and auditory spectral modulation detection, learning depended upon and was specific to analogous features of the trained stimulus. Such similarities in learning could arise if, as has been suggested, similar constraints limit the ability to detect patterns across the receptor surface between the auditory and visual systems.
- 1 May 2011
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 32 (3) , 399-409
Weighting Function-Based Mapping of Descriptors to Frequency-Gain Curves in Listeners With Hearing Loss
The frequency-gain curve (FGC) is among the most important parameters to consider when fitting a hearing aid. In practice, a prescriptive FGC, derived from the audiogram, is initially applied. In the subsequent fine-tuning stage, the patient often communicates their concerns about the sound quality using descriptors (e.g., "it sounds hollow") and the clinician modifies the FGC accordingly. In this study, we present and evaluate a method that could enhance this process by rapidly mapping descriptors to FGC shapes. In addition, we begin to use this method to examine the extent to which there is across-individual agreement in how descriptors map to FGC shapes. Ten listeners with hearing loss rated the extent to which each of a series of FGCs captured the meaning of a particular descriptor. Regression analyses were conducted to determine the degree to which these ratings were correlated with the gain values associated with each of 25 frequency bands. The array of slopes of these regression lines across frequency bands is termed the weighting function and was interpreted as the FGC shape that corresponded to the descriptor. We used this procedure to determine the FGC shapes associated with four of the most common descriptors used to describe hearing aid sound quality problems ("tinny," "sharp," "hollow," and "in a barrel, tunnel, or well"). The weighting function shape was highly replicable despite variable listener responses, reached asymptotic performance quickly (<20 ratings), and was predictive of listener responses. On the global level, there was some agreement across individuals about how common descriptors mapped to weighting function shape. However, considerable differences were apparent between individuals in terms of the specifics of that mapping. The current approach for descriptor-to-FGC mapping is a quick, reliable method for determining individualized changes to the FGC. Given the range of individual differences in the specifics of the descriptor-to-FGC mappings observed, this approach could be useful in a clinical setting to easily quantify these acoustic parameters. Implementation of such procedures could lead to more personalized fine-tuning of amplification devices.
- 1 May 2011
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 32 (3) , 399-409
Weighting Function-Based Mapping of Descriptors to Frequency-Gain Curves in Listeners With Hearing Loss
The frequency-gain curve (FGC) is among the most important parameters to consider when fitting a hearing aid. In practice, a prescriptive FGC, derived from the audiogram, is initially applied. In the subsequent fine-tuning stage, the patient often communicates their concerns about the sound quality using descriptors (e.g., "it sounds hollow") and the clinician modifies the FGC accordingly. In this study, we present and evaluate a method that could enhance this process by rapidly mapping descriptors to FGC shapes. In addition, we begin to use this method to examine the extent to which there is across-individual agreement in how descriptors map to FGC shapes. Ten listeners with hearing loss rated the extent to which each of a series of FGCs captured the meaning of a particular descriptor. Regression analyses were conducted to determine the degree to which these ratings were correlated with the gain values associated with each of 25 frequency bands. The array of slopes of these regression lines across frequency bands is termed the weighting function and was interpreted as the FGC shape that corresponded to the descriptor. We used this procedure to determine the FGC shapes associated with four of the most common descriptors used to describe hearing aid sound quality problems ("tinny," "sharp," "hollow," and "in a barrel, tunnel, or well"). The weighting function shape was highly replicable despite variable listener responses, reached asymptotic performance quickly (<20 ratings), and was predictive of listener responses. On the global level, there was some agreement across individuals about how common descriptors mapped to weighting function shape. However, considerable differences were apparent between individuals in terms of the specifics of that mapping. The current approach for descriptor-to-FGC mapping is a quick, reliable method for determining individualized changes to the FGC. Given the range of individual differences in the specifics of the descriptor-to-FGC mappings observed, this approach could be useful in a clinical setting to easily quantify these acoustic parameters. Implementation of such procedures could lead to more personalized fine-tuning of amplification devices.
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4_Suppleme) , 2488
Spectro-temporal specificity of learning on modulation depth discrimination.
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4_Suppleme) , 2488
Spectro-temporal specificity of learning on modulation depth discrimination.
- 1 April 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (4_Suppleme) , 2633
Spectral modulation detection training in older adults with hearing loss.
- 1 April 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (4_Suppleme) , 2633
Spectral modulation detection training in older adults with hearing loss.
- 1 April 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (4_Suppleme) , 2723
A weighting-function-based approach to subjectively modify the frequency response of a hearing aid.
- 1 April 2009
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 125 (4_Suppleme) , 2723
A weighting-function-based approach to subjectively modify the frequency response of a hearing aid.