Raphaël Vialle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Raphaël Vialle has a total of 153 co-authors. Here are the top co-authors by number of shared publications:
Pierre Mary
Department of Pediatric Orthopaedics, Armand Trousseau Hospital, Université Pierre et Marie Curie Paris6, Paris Cedex 12, France
15 shared publicationsManon Bachy
From the The MAMUTH Hospital-University Department for Innovative Therapies in Musculoskeletal Diseases
11 shared publicationsJean-Paul Damsin
Department of Paediatric Orthopaedics, Armand Trousseau Hospital, Université Pierre et Marie Curie-Paris 6, 26 Avenue du Docteur Arnold Netter, F-75571 Paris, CEDEX 12, France. address for R. Vialle
8 shared publicationsCamille Thevenin-Lemoine
Department of Pediatric Orthopaedics, Université Pierre et Marie Curie Paris6, Armand Trousseau Hospital, 26 avenue du Dr. Arnold Netter, 75571, Paris Cedex 12 France
7 shared publicationsCamille Thévenin-Lemoine
Department of Pediatric Orthopaedics, Armand Trousseau Hospital, Université Pierre et Marie Curie Paris 6, Paris Cedex 12, France
5 shared publicationsAmélie Rogier
Department of Pediatric Orthopaedics, Université Pierre et Marie Curie Paris6, Armand Trousseau Hospital, 26 avenue du Dr. Arnold Netter, 75571, Paris Cedex 12 France
4 shared publications
Latest Publications
- 1 April 2020
- Published by Wolters Kluwer Health in Pediatric Emergency Care
- Vol. 36 (4) , 187-191
Early Ultrasound Follow-Up of Extension-Type Supracondylar Fractures Treated by the Collar-and-Cuff (Blount) Technique
Extension-type supracondylar fractures can be treated with external immobilization, with the elbow flexed 100°. However, this technique requires early evaluation by true lateral x-ray of the elbow to detect secondary fracture displacement. The purpose of this work is to evaluate whether ultrasound imaging is suitable for demonstrating initial reduction of supracondylar fractures and early secondary displacement of the fracture. Fourteen patients aged 3 to 7 years (mean, 4.8 years) were treated by closed reduction under general anesthesia and immobilization with a collar and cuff. All patients had early postoperative x-rays and ultrasonography on day 1, as well as day 8 x-rays and ultrasonography. Ultrasonograms were performed by an experienced senior radiologist. In all cases, a complete reduction was confirmed at initial follow-up on both sonogram and intraoperative fluoroscopy. In 13 of 14 cases, no secondary displacement of the fracture was noted at day 8 on either ultrasonography or x-ray images. In 1 case, a secondary displacement was noted at day 8 on ultrasonography and confirmed by the lateral x-ray. Our study found a complete agreement assessing the quality of intraoperative reduction of supracondylar fractures by radiographs and ultrasonography. These results confirm that ultrasound imaging is suitable for demonstrating secondary displacements of supracondylar fractures in children. We postulate that in Gartland types II and III fractures treated by Blount procedure, a negative ultrasound result at day 8 follow-up may reduce the need for further radiographs. However, in any doubtful situation, the need for conventional radiographs remains. Diagnostic study, level II.
- 1 April 2020
- Published by Wolters Kluwer Health in Pediatric Emergency Care
- Vol. 36 (4) , 187-191
Early Ultrasound Follow-Up of Extension-Type Supracondylar Fractures Treated by the Collar-and-Cuff (Blount) Technique
Extension-type supracondylar fractures can be treated with external immobilization, with the elbow flexed 100°. However, this technique requires early evaluation by true lateral x-ray of the elbow to detect secondary fracture displacement. The purpose of this work is to evaluate whether ultrasound imaging is suitable for demonstrating initial reduction of supracondylar fractures and early secondary displacement of the fracture. Fourteen patients aged 3 to 7 years (mean, 4.8 years) were treated by closed reduction under general anesthesia and immobilization with a collar and cuff. All patients had early postoperative x-rays and ultrasonography on day 1, as well as day 8 x-rays and ultrasonography. Ultrasonograms were performed by an experienced senior radiologist. In all cases, a complete reduction was confirmed at initial follow-up on both sonogram and intraoperative fluoroscopy. In 13 of 14 cases, no secondary displacement of the fracture was noted at day 8 on either ultrasonography or x-ray images. In 1 case, a secondary displacement was noted at day 8 on ultrasonography and confirmed by the lateral x-ray. Our study found a complete agreement assessing the quality of intraoperative reduction of supracondylar fractures by radiographs and ultrasonography. These results confirm that ultrasound imaging is suitable for demonstrating secondary displacements of supracondylar fractures in children. We postulate that in Gartland types II and III fractures treated by Blount procedure, a negative ultrasound result at day 8 follow-up may reduce the need for further radiographs. However, in any doubtful situation, the need for conventional radiographs remains. Diagnostic study, level II.
- 1 October 2016
- Published by Elsevier in The Spine Journal
- Vol. 16 (10) , S283-S284
Preoperative Rib Cage Measurement Reproducibility Using 3D Stereoradiographic Reconstructions in Adolescent Idiopathic Scoliosis
- 1 October 2016
- Published by Elsevier in The Spine Journal
- Vol. 16 (10) , S283-S284
Preoperative Rib Cage Measurement Reproducibility Using 3D Stereoradiographic Reconstructions in Adolescent Idiopathic Scoliosis
- 1 April 2016
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 102 (2) , 189-195
Allograft integration in a rabbit transgenic model for anterior cruciate ligament reconstruction
- 1 April 2016
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 102 (2) , 189-195
Allograft integration in a rabbit transgenic model for anterior cruciate ligament reconstruction
- 11 August 2015
- Published by Springer Nature in European Spine Journal
- Vol. 24 (11) , 2580-2587
Screw augmentation for spinopelvic fixation in neuromuscular spine deformities: technical note
The primary goal of curve correction in neuromuscular patients is to restore coronal and sagittal trunk balance, including the pelvis, to maximize sitting balance. For several years, it has been a common practice to inject polymeric cement into osteoporotic bone through specially designed, perforated pedicle screws in an effort to enhance screw stability. Therefore, we started using the association of a spinopelvic fixation with S1 pedicle screw augmentation, using bisphenol-a-glycidyl dimethacrylate composite resin in neuromuscular patients with pelvic obliquity, technique in neuromuscular patients to improve pedicle screw stability of our pelvic construct. Ten patients undergoing spinopelvic fixation for a neuromuscular spinal deformity were enrolled in the study. Clinical and radiographic data were analyzed and presented. Minimal follow-up took place at 6 months to assess early complications. Five patients were diagnosed with spastic quadriplegia secondary to cerebral palsy, four had Duchenne’s muscular dystrophy, and one had a T5-level traumatic flaccid paraplegia. Preoperative PO ranged from 8° to 34° (mean 19.16°). Postoperative PO ranged from 0° to 6.3° (mean 1.6°). After surgery, all patients returned to a full-time sitting position between days 5 and 12 without the need for additional bracing. No mechanical failure of the construct was noted during follow-up. We used sacral pedicle screw augmentation as a reliable tool to strengthen spinopelvic fixation in neuromuscular scoliosis without increasing the intraoperative morbidity. In our practice, sacral screw augmentation can definitely enhance PO correction obtained by a posterior procedure.
- 11 August 2015
- Published by Springer Nature in European Spine Journal
- Vol. 24 (11) , 2580-2587
Screw augmentation for spinopelvic fixation in neuromuscular spine deformities: technical note
The primary goal of curve correction in neuromuscular patients is to restore coronal and sagittal trunk balance, including the pelvis, to maximize sitting balance. For several years, it has been a common practice to inject polymeric cement into osteoporotic bone through specially designed, perforated pedicle screws in an effort to enhance screw stability. Therefore, we started using the association of a spinopelvic fixation with S1 pedicle screw augmentation, using bisphenol-a-glycidyl dimethacrylate composite resin in neuromuscular patients with pelvic obliquity, technique in neuromuscular patients to improve pedicle screw stability of our pelvic construct. Ten patients undergoing spinopelvic fixation for a neuromuscular spinal deformity were enrolled in the study. Clinical and radiographic data were analyzed and presented. Minimal follow-up took place at 6 months to assess early complications. Five patients were diagnosed with spastic quadriplegia secondary to cerebral palsy, four had Duchenne’s muscular dystrophy, and one had a T5-level traumatic flaccid paraplegia. Preoperative PO ranged from 8° to 34° (mean 19.16°). Postoperative PO ranged from 0° to 6.3° (mean 1.6°). After surgery, all patients returned to a full-time sitting position between days 5 and 12 without the need for additional bracing. No mechanical failure of the construct was noted during follow-up. We used sacral pedicle screw augmentation as a reliable tool to strengthen spinopelvic fixation in neuromuscular scoliosis without increasing the intraoperative morbidity. In our practice, sacral screw augmentation can definitely enhance PO correction obtained by a posterior procedure.
- 26 June 2015
- Published by Springer Nature in Pediatric Radiology
- Vol. 45 (12) , 1864-1869
A radiolucent chair for sitting-posture radiographs in non-ambulatory children: use in biplanar digital slot-scanning
EOS imaging (EOS System; EOS imaging, Paris, France) enables fast 2-D/3-D imaging of children in standing load-bearing position. Non-ambulatory children with neuromuscular scoliosis need evaluation of their spinal balance while in a normal daily position. We designed a customized chair fitting the EOS patient-area dimensions to obtain images in natural sitting postures. The chair is a 360° rotating orthopaedic chair made of fully radiolucent polyethylene and equipped with an adjustable headrest and three-point belts. Out of 41 consecutive patients, 36 (88%, 95% confidence interval 74–96%) had successful imaging. In most patients with severe neuromuscular trunk deformities, the EOS system combined with our chair was useful for assessing preoperative trunk collapse, pelvic obliquity and postoperative corrections in all planes. This specific device changed our daily practice for the assessment of spinal deformities in non-ambulatory patients.
- 26 June 2015
- Published by Springer Nature in Pediatric Radiology
- Vol. 45 (12) , 1864-1869
A radiolucent chair for sitting-posture radiographs in non-ambulatory children: use in biplanar digital slot-scanning
EOS imaging (EOS System; EOS imaging, Paris, France) enables fast 2-D/3-D imaging of children in standing load-bearing position. Non-ambulatory children with neuromuscular scoliosis need evaluation of their spinal balance while in a normal daily position. We designed a customized chair fitting the EOS patient-area dimensions to obtain images in natural sitting postures. The chair is a 360° rotating orthopaedic chair made of fully radiolucent polyethylene and equipped with an adjustable headrest and three-point belts. Out of 41 consecutive patients, 36 (88%, 95% confidence interval 74–96%) had successful imaging. In most patients with severe neuromuscular trunk deformities, the EOS system combined with our chair was useful for assessing preoperative trunk collapse, pelvic obliquity and postoperative corrections in all planes. This specific device changed our daily practice for the assessment of spinal deformities in non-ambulatory patients.
- 1 March 2015
- Published by Elsevier in Archives de Pédiatrie
- Vol. 22 (3) , 331-336
Anomalies des pieds à la naissance
- 1 March 2015
- Published by Elsevier in Archives de Pédiatrie
- Vol. 22 (3) , 331-336
Anomalies des pieds à la naissance
- Open Access
- 2 January 2015
- Published by Hindawi Limited in Pain Research and Management
- Vol. 20 (1) , e28-e32
How Can Surgeonfish Help Pediatric Surgeons? A Pilot Study Investigating the Antinociceptive Effect of Fish Aquariums in Adult Volunteers
BACKGROUND: Multiple distraction strategies have been proposed to reduce the incidence of anxiety and pain in children. Animal-assisted therapy is acknowledged and used in children as an adjunctive treatment with cognitive, physical, psychosocial and spiritual benefits.
- 2 January 2015
- Published by Hindawi Limited in Pain Research and Management
- Vol. 20 (1) , e28-e32
Open AccessHow Can Surgeonfish Help Pediatric Surgeons? A Pilot Study Investigating the Antinociceptive Effect of Fish Aquariums in Adult Volunteers
BACKGROUND: Multiple distraction strategies have been proposed to reduce the incidence of anxiety and pain in children. Animal-assisted therapy is acknowledged and used in children as an adjunctive treatment with cognitive, physical, psychosocial and spiritual benefits.
- 14 May 2014
- Published by Springer Nature in European Spine Journal
- Vol. 23 (S4) , 452-456
The “slide technique”: an improvement on the “funnel technique” for safe pedicle screw placement in the thoracic spine
Technical note. To report and describe a new free-hand technique for pedicle screw placement in the thoracic spine especially in severe deformities. Because of distortion of anatomic landmarks scoliosis, this free-hand placement technique based on pedicle access through the decancelled transverse process is a safe procedure. Transverse process is widely exposed and its posterior cortex is decorticated. The cancellous bone content of the transverse process is completely removed using a small curette. Bone wax is applied to avoid local bleeding and then the decancelled transverse process is inspected. The entry of the pedicle is then easily identified by the presence of remaining cancellous bone. A pedicular probe is then inserted and gently advanced. During pedicle probe insertion, the cortex of the anterior aspect of transverse process and the lateral margin of the pedicle act as a “slide” to permit safe insertion of the instrument. In our experience, no patient required additional procedures for screw revision, and no neurologic deficit occurred stemming from malpositioning of pedicle screws. The key point of the “slide technique” is to use the cortex of the anterior aspect of transverse process and the lateral margin of the pedicle as a “slide” to permit correct probe positioning during pedicle probe insertion. This technique is very close to the “funnel technique”. The “funnel” and then the “slide” technique are mostly useful in complex spinal deformities as in neuromuscular patients. The “slide technique” is a safe, effective and cost-effective technique for pedicle screw placement in the thoracic spine especially in severe deformities. IV.
- 14 May 2014
- Published by Springer Nature in European Spine Journal
- Vol. 23 (S4) , 452-456
The “slide technique”: an improvement on the “funnel technique” for safe pedicle screw placement in the thoracic spine
Technical note. To report and describe a new free-hand technique for pedicle screw placement in the thoracic spine especially in severe deformities. Because of distortion of anatomic landmarks scoliosis, this free-hand placement technique based on pedicle access through the decancelled transverse process is a safe procedure. Transverse process is widely exposed and its posterior cortex is decorticated. The cancellous bone content of the transverse process is completely removed using a small curette. Bone wax is applied to avoid local bleeding and then the decancelled transverse process is inspected. The entry of the pedicle is then easily identified by the presence of remaining cancellous bone. A pedicular probe is then inserted and gently advanced. During pedicle probe insertion, the cortex of the anterior aspect of transverse process and the lateral margin of the pedicle act as a “slide” to permit safe insertion of the instrument. In our experience, no patient required additional procedures for screw revision, and no neurologic deficit occurred stemming from malpositioning of pedicle screws. The key point of the “slide technique” is to use the cortex of the anterior aspect of transverse process and the lateral margin of the pedicle as a “slide” to permit correct probe positioning during pedicle probe insertion. This technique is very close to the “funnel technique”. The “funnel” and then the “slide” technique are mostly useful in complex spinal deformities as in neuromuscular patients. The “slide technique” is a safe, effective and cost-effective technique for pedicle screw placement in the thoracic spine especially in severe deformities. IV.
- 10 May 2014
- Published by Springer Nature in European Spine Journal
- Vol. 23 (S4) , 406-411
Non-invasive positive pressure ventilation to facilitate the post-operative respiratory outcome of spine surgery in neuromuscular children
Scoliosis surgery may be associated with a high morbidity and even mortality in children with non-idiopathic scoliosis. The aim of the study was to report our experience with a pre-operative training to non-invasive positive pressure ventilation (NPPV) and a mechanical insufflator–exsufflator (MI–E) device to improve the post-operative respiratory outcome of children scheduled for scoliosis surgery. Consecutive patients with non-idiopathic scoliosis undergoing posterior arthrodesis were trained to NPPV and MI–E before intervention. NPPV and MI–E were performed immediately after extubation. Length of intubation and intensive care unit (ICU) stay, duration of NPPV, and respiratory complications were assessed. Thirteen patients participated in the training (mean age 13.9 ± 2.6, mean vital capacity 52.3 ± 15.4 % predicted). The patients had severe respiratory muscle weakness with a mean sniff oesophageal pressure of 35.8 ± 14.2 cmH2O (50 % predicted) and a mean gastric pressure during a cough of 31.9 ± 7.8 cmH2O (30 % predicted). The mean length of intubation was 19.9 ± 12.3 h with a mean length of ICU stay of 2.5 ± 2.5 days. NPPV was used during a mean of 2.7 ± 1.9 days after surgery. No respiratory complication was observed. One patient died 3 months after surgery from multi-organ failure of non-respiratory origin. No respiratory complications were observed after scoliosis correction surgery in children with non-idiopathic scoliosis after pre-operative training and post-operative use of NPPV and MI–E, underlying the interest of this management in these high-risk patients.
- 10 May 2014
- Published by Springer Nature in European Spine Journal
- Vol. 23 (S4) , 406-411
Non-invasive positive pressure ventilation to facilitate the post-operative respiratory outcome of spine surgery in neuromuscular children
Scoliosis surgery may be associated with a high morbidity and even mortality in children with non-idiopathic scoliosis. The aim of the study was to report our experience with a pre-operative training to non-invasive positive pressure ventilation (NPPV) and a mechanical insufflator–exsufflator (MI–E) device to improve the post-operative respiratory outcome of children scheduled for scoliosis surgery. Consecutive patients with non-idiopathic scoliosis undergoing posterior arthrodesis were trained to NPPV and MI–E before intervention. NPPV and MI–E were performed immediately after extubation. Length of intubation and intensive care unit (ICU) stay, duration of NPPV, and respiratory complications were assessed. Thirteen patients participated in the training (mean age 13.9 ± 2.6, mean vital capacity 52.3 ± 15.4 % predicted). The patients had severe respiratory muscle weakness with a mean sniff oesophageal pressure of 35.8 ± 14.2 cmH2O (50 % predicted) and a mean gastric pressure during a cough of 31.9 ± 7.8 cmH2O (30 % predicted). The mean length of intubation was 19.9 ± 12.3 h with a mean length of ICU stay of 2.5 ± 2.5 days. NPPV was used during a mean of 2.7 ± 1.9 days after surgery. No respiratory complication was observed. One patient died 3 months after surgery from multi-organ failure of non-respiratory origin. No respiratory complications were observed after scoliosis correction surgery in children with non-idiopathic scoliosis after pre-operative training and post-operative use of NPPV and MI–E, underlying the interest of this management in these high-risk patients.