LVLaurent Vastel

Laurent Vastel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Laurent Vastel has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Structural allograft and cemented long-stem prosthesis for complex revision hip arthroplasty: use of a trochanteric claw plate improves final hip function

    by Laurent Vastel, Camille Thevenin Lemoine, Marcel Kerboull, Jean Pierre Courpied

    Extensive bone loss raises formidable challenges in total hip revision. The aim of this study was to evaluate the results of reconstruction using a cemented long-stem and massive structural allograft implanted in a filleted proximal femur, with and without the use of a trochanteric claw plate. Between 1988 and 2001, 44 revisions were performed in 42 patients. After a transtrochanteric approach, the femur was cut longitudinally. A long, cemented Charnley-type prosthesis was used, and flaps of the residual femur were folded around the allograft. The greater trochanter was reinserted with wires in all revisions, and with both wires and a claw plate in 20 revisions. Mean follow-up was 7.15 years (range: 3–16); seven patients, died and four were lost to follow-up. The follow-up exceeded five years in 34 patients. The major complication was nonunion of the greater trochanter, which occurred in 25 cases. Six dislocations, one recurrence of infection, two mechanical loosening, and two fractures below the stem were also recorded. The use of a trochanteric claw plate significantly improved final hip stability, even in patients with nonunion. Femoral reconstruction with a massive structural allograft is reliable and long-lived, and serious complications and long-term resorption are uncommon. The use of a trochanteric claw plate significantly improves final hip stability. Level of evidence: Therapeutic study, level III (retrospective comparative study).


  • SURGICAL TREATMENT OF PIGMENTED VILLONODULAR SYNOVITIS OF THE HIP

    by Laurent Vastel, Patrick Lambert, Gonzague DE Pinieux, Olivier Charrois, Marcel Kerboull, Jean-Pierre Courpied

    Aim of this study was to determine the long-term outcome of the treatment in sixteen patients....


  • Surgical Treatment of Pigmented Villonodular Synovitis of the Hip

    by Laurent Vastel, Patrick Lambert, Gonzague De Pinieux, Olivier Charrois, Marcel Kerboull, Jean-Pierre Courpied

    Aim of this study was to determine the long-term outcome of the treatment in sixteen patients....


    • 1 December 2000
      • Vol. 58, 488-98

    [Quality plan of a bone tissue bank].

    by V Lemercier, L Vastel, J P Courpied

    In 1994, the French bioethics laws changed the regulations concerning donated human tissues with safety precautions and therapeutic use. The decree of 29(th) December 1998 describes the practical obligations required of bone tissue banks for approval by the French Health Ministry. Before the new regulations, a quality system was implemented at the Cochin hospital bone tissue bank. It integrates quality control for each step of the general process. We describe the quality plan of the Cochin Hospital bone tissue bank and show that the specific quality practices, resources and sequence of activities improve distribution of human bone allografts while maintaining their traceability.


    • 1 December 2000
      • Vol. 86  (8) , 801-8

    [Femoral reconstruction with massive allograft implanted in a split femur. Mid-term results of 18 reconstructions].

    by O Charrois, L Kerboull, L Vastel, J P Courpied, M Kerboull

    Extensive loss of femoral bone subsequent to implant loosening raises an unsolved problem. The purpose of this work was to examine mid-term results of 18 iterative total hip arthroplasties with femoral reconstruction using massive allografts performed between 1986 and 1997. Using the Vives classification, the femoral bone lesions were grade 3 (n =2) and grade 4 (n =16). The reconstruction was achieved with radiated massive allografts measuring 11 to 35 cm implanted in a split host femur. Charnley-Kerboull implants with a long stem were cemented in the reconstructed femurs. Mean follow-up was 4 years 10 months (range 2 to 9 years). Nine complications in 7 hips were observed: 6 trochanter nonunions, two recurrent prosthesis dislocations and 1 femoral fracture. At last follow-up, the functional result was excellent or very good in 12 hips (Merle d'Aubigné classification). A stable fixation persisted for 15 implants and 3 had loosened. Graft-host femur consolidation was achieved in all cases except 1. There were 3 cases with extensive resorption of the graft including 2 associated with loosening of the femoral component. Reconstruction of the femur after extensive bone loss using a massive allograft appears to be a useful method for restoring bone tissue and providing immediate mechanical support for the femur.

    • 1 June 2000
      • Vol. 45  (3) , 354-63

    [Bone allografts in orthopedic surgery: current concepts].

    by L Vastel, P Anract, J P Courpied

    In the last decade, indications for bone allografting in orthopedic surgery have progressively increased, related to, on the one part, treatment of benign or malignant tumors, but, on another (major) part, to treatment of major bone defects due to loosening of hip or knee total prostheses. In France, legislation and control concerning donated human tissues, safety precautions, and the uses for human tissues have been greatly modified over the last few years. The authors describe the various obligations implicated by these activities and the consequences for tissue banks and surgeons; They describe different processes for bone inactivation and their action on allograft mechanical properties, or the biological capability for integration to the host bone. The authors then discuss different current techniques for bone stock reconstruction and the results in prosthetic or tumoral surgery, as well as their consequences on current surgical indications. In conclusion, they emphasize the optimal conditions for the success of allografts in orthopedic use: stability of the host bone-graft junction, vitality of the bone support, and a favourable mode of constraint of the graft, which have to be protected by osteosynthesis, but should not, however, miss partial bearing.


    • 1 September 1999
      • Vol. 85  (5) , 458-65

    [Knee replacement arthroplasty in hemophilia: results, complications and predictive elements of their occurrence].

    by L Vastel, J P Courpied, Y Sultan, M Kerboull

    Determine the effect of supplementation rate and HIV disease on results and complications in total knee replacement in hemophilia. Twenty-nine total knee arthroplasties were performed in twenty-one disabled patients with major hemophilia, from 1986 to 1995. All the implants were postero-stabilised prostheses. The average age of patients at the time of surgery was 40.8 years, average follow-up was 4.8 years. Preoperatively, all patients complained of severe pain, with stage IV or V arthropathies, according to Arnold classification. Twelve patients were HIV sero-positive. Functional and radiological results, and postoperative complication rate was analyzed in relation with mean deficient factor titer, HIV status, and periarticular soft tissues quality. Results of the total knee arthroplasties, as determined by the IKS scoring system, were 86.2/100 for Pain, Motion, Stability and 88.7/100 for function. The average gain of motion was twenty-four degrees. One patient required amputation, and one an arthrodesis after deep infection. Postoperative complications, in addition to infections, included intra articular bleeding in nine patients, one peroneal nerve palsy, two instances of inhibition to factor VIII, four superficial skin necrosis, and one important gastric bleeding which required surgical treatment. A high titer of deficient factor (> 70 per cent of the average normal concentration) seemed correlated with a lower complication rate. In this study, surgery had no incidence on HIV disease evolution. Authors emphasize the high level of postoperative infections (6/29), particularly in patients with HIV infection (5/12) frequently after superficial skin necrosis, as well as the high postoperative complication rate. However good results were finally observed, association of HIV disease, insufficient deficient factor concentration, and altered quality of periarticular soft tissues increased particularly complication occurrence. With particular attention to these factors, and despite frequent complications, total knee arthroplasty in hemophilia restores good function and allows patients satisfaction.


    • 1 May 1999
      • Vol. 85  (2) , 164-73

    [Functioning of a bone tissue bank in 1998].

    by L Vastel, V Lemercier, L Kerboull, M Kerboull

    Last few years, the french legislation and reglementation concerning donated human tissues, safety precautions, and human tissues' uses have been deeply modified. Therefore, tissue banks' organisation, processing of allograft tissue, and the way surgeons use frozen bone graft have changed. Accordingly, authors describe different obligations these activities implicate and practical consequences for tissue banks and surgeons. First, they recall 94' laws and the doctrinal and ethical principles essential to understand current laws and official standards. Then, they specify sanitary rules all tissue banks have to conform to. They detail the different approaches to recovery, processing, preservation and distribution of transplantable bone tissue and expose modalities of the financing by social organisms. It follows practical consequences in bank functioning: supplying, importation, internal organization. In conclusion, authors synthesize surgeon's responsibilities in that specific activity.