KAKai-Nan An

Kai-Nan An

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kai-Nan An has a total of 188 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Radiographic cup anteversion measurement corrected from pelvic tilt

    by Liao Wang, Andrew R. Thoreson, Robert T. Trousdale, Bernard F. Morrey, Kerong Dai, Kai-Nan An

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P < 0.001). The mean of 90 slopes and y-intercepts of the regression lines were -0.8 and -2.5°, which were applied as the general correction parameters for the proposed tool to correct conventional cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs.


  • Development of a hyperelastic material model of subsynovial connective tissue using finite element modeling

    by Yusuke Matsuura, Andrew R. Thoreson, Chunfeng Zhao, Peter C. Amadio, Kai-Nan An


  • Anthropometric Study of the Radio-Capitellar Joint

    by Matthias Vanhees, Dave R. Shukla, James S. Fitzsimmons, Kai-Nan An, Shawn W. O'Driscoll


  • Mid-range shoulder instability modeled as a cam-follower mechanism

    by Laurent Willemot, Andrew Thoreson, Ryan Breighner, Alexander Hooke, Olivier Verborgt, Kai-Nan An


  • Iliac bone grafting of the intact glenoid improves shoulder stability with optimal graft positioning

    by Laurent B. Willemot, Sarah F. Eby, Andrew R. Thoreson, Phillipe Debeer, Jan Victor, Kai-Nan An, Olivier Verborgt


  • Feasibility assessment of shear wave elastography to rotator cuff muscle

    by Yoshiaki Itoigawa, John W. Sperling, Scott P. Steinmann, Qingshan Chen, Pengfei Song, Shigao Chen, Eiji Itoi, Taku Hatta, Kai‐Nan An

    Pre‐surgical measurement of supraspinatus muscle extensibility is important for rotator cuff repair. The purpose of the present study was to explore the potential feasibility of a shear wave ultrasound elastography (SWE)‐based method, combined with B‐mode ultrasound, to measure the in vivo stiffness of the supraspinatus muscle non‐invasively and thus obtain key information about supraspinatus muscle extensibility. Our investigation comprised two steps. First, we determined the orientation of the supraspinatus muscle fibers in cadaveric shoulders without rotator cuff tear in order to optimize the ultrasound probe positions for SWE imaging. Second, we investigated the feasibility of quantifying the stiffness of the normal supraspinatus muscle by SWE in vivo. The supraspinatus muscle was divided into four anatomical regions: anterior superficial (AS), posterior superficial (PS), anterior deep (AD), and posterior deep (PD). Each region was examined by SWE. The SWE stiffnesses of AD, AS, PD, and PS were 40.0 ± 12.4, 34.0 ± 9.9, 32.7 ± 12.7, 39.1 ± 15.7 kPa, respectively. SWE combined with B‐Mode ultrasound imaging could be a feasible method for quantifying the local stiffness of the rotator cuff muscles. Clin. Anat. 28:213–218, 2015.


  • Specimen-Specific Nonlinear Finite Element Modeling to Predict Vertebrae Fracture Loads After Vertebroplasty

    by Y. Matsuura, H. Giambini, Y. Ogawa, Z. Fang, A. R. Thoreson, M. J. Yaszemski, L. Lu, K. N. An

    Study Design. Vertebral fracture load and stiffness from a metastatic vertebral defect model were predicted using nonlinear finite element models (FEM) and validated experimentally. Objective. The study objective was to develop and validate an FEM-based tool for predicting polymer-augmented lytic vertebral fracture load and stiffness and the influence of metastatic filling materials. Summary of Background Data. Percutaneous vertebroplasty has the potential to reduce vertebral fracture risk affected with lytic metastases by providing mechanical stabilization. However, it has been shown that the mismatch in mechanical properties between poly(methyl-methacrylate) (PMMA) and bone induces secondary fractures and intervertebral disc degeneration. A biodegradable copolymer, poly(propylene fumarate-co-caprolactone) (P(PF-co-CL)), has been shown to possess the appropriate mechanical properties for bone defect repair. Methods. Simulated metastatic lytic defects were created in 40 cadaveric vertebral bodies, which were randomized into 4 groups: intact vertebral body (intact), simulated defect without treatment (negative), defect treated with P(PF-co-CL) (copolymer), and defect treated with PMMA (PMMA). Spines were imaged with quantitative computed tomography (QCT), and QCT/FEM-subject-specific, nonlinear models were created. Predicted fracture loads and stiffness were identified and compared with experimentally measured values using Pearson correlation analysis and paired t test. Results. There was no significant difference between the measured and predicted fracture loads and stiffness for each group. Predicted fracture loads were larger for PMMA augmentation (3960 N [1371 N]) than that for the copolymer, negative and intact groups (3484 N [1497 N], 3237 N [1744 N], and 1747 N [702 N]). A similar trend was observed in the predicted stiffness. Moreover, predicted and experimental fracture loads were strongly correlated (R2 = 0.78), whereas stiffness showed moderate correlation (R2 = 0.39). Conclusion. QCT/FEM was successful for predicting fracture loads of metastatic, polymer-augmented vertebral bodies. Overall, we have demonstrated that QCT/FEM may be a useful tool for predicting in situ vertebral fracture load resulting from vertebroplasty. Level of Evidence: N/A


  • Diagnosis of small partial-thickness rotator cuff tears using vibro-acoustography

    by Nobuyuki Yamamoto, Randall R. Kinnick, Mostafa Fatemi, Takayuki Muraki, John W. Sperling, Scott P. Steinmann, Robert H. Cofield, Eiji Itoi, Kai-Nan An

    Vibro-acoustography is a new imaging technique based on the dynamic radiation force of ultrasound. The purpose of this study was to apply this new imaging technique to the diagnosis of small partial-thickness rotator cuff tears and to determine how small of tears could be detected with this imaging technique. Seven supraspinatus tendons excised from embalmed cadavers were used. Three different sizes of partial-thickness bursal-sided tears (1, 3, and 5 mm3) were created in each specimen. The intersection of two co-focused ultrasound beams of slightly different frequency was swept across the intended imaging area. The acoustic emission data were collected and used to form and display a vibro-acoustography image of the tendon. Vibro-acoustography images were read by two orthopedic surgeons. The rotator cuff tear could be detected by vibro-acoustography in all specimens. The diagnostic concordance rate was 90.5 % and the kappa coefficient value was 0.88, which resulted in a high concordance. The diagnostic concordance rate for the 1 mm tear was 71.3 %, which was low concordance (κ = 0.481), whereas that for the 3 and 5 mm tears was 100 %. We were able to detect a 3-mm tear by using vibro-acoustography. There is a possibility that this new imaging technique could become a useful imaging tool for the diagnosis of small partial-thickness rotator cuff tears.


  • The Effect of the Remplissage Procedure on Shoulder Range of Motion: A Cadaveric Study

    by Rei Omi, Alexander W. Hooke, Kristin D. Zhao, Tomoya Matsuhashi, Akira Goto, Nobuyuki Yamamoto, John W. Sperling, Scott P. Steinmann, Eiji Itoi, Kai‐Nan An

    Purpose: The purpose of this in vitro biomechanical study was to assess the effects of the remplissage procedure for small‐ and large‐sized Hill‐Sachs lesions (HSLs) on shoulder range of motion (ROM) with a special interest in the apprehension position. Methods: HSLs of 50% and 100% of the glenoid width were simulated in 7 cadaveric shoulders as small and large lesions, respectively, and the postoperative condition was reproduced by placing suture anchors on the articular surface and tying down the infraspinatus at the medial edge of the would‐be lesion site. ROMs were measured in abduction, internal rotation, and external rotation with the humerus in the adducted and abducted position. In addition, the ROM was measured in the anterior apprehension position, in which 2 torques of external rotation and extension were applied simultaneously, and external rotation and horizontal extension ROMs were measured with the humerus in different abduction angles (20°, 40°, and 60°). Results: For standard ROMs, the procedure for the 50% HSL maintained complete ROMs, whereas the procedure for the 100% HSL significantly decreased external rotation ROM with the humerus in both the adducted and abducted positions, as well as abduction ROM. In the apprehension position, remplissage for the 50% HSL decreased extension ROM with the humerus abducted to 40° and 60°. Remplissage for the 100% HSL significantly decreased both external and extension ROMs regardless of the humeral abduction angle. Conclusions: In the cadaveric model with an intact humeral head and the simulated postoperative condition, the remplissage procedure for a large HSL caused significant restrictions in ROM of abduction in the scapular plane and external rotation with the humerus in both adduction and abduction. It also caused significant restrictions in both external rotation and extension ROMs in the apprehension position. Clinical Relevance: The indication for the remplissage procedure for the larger HSL should be considered carefully, especially for the competitive throwing athlete who needs exceptional external rotation ROM for optimal overhead throwing performance.


  • Posterior tibial tendon dysfunction and flatfoot: Analysis with simulated walking

    by Kota Watanabe, Harold B. Kitaoka, Tadashi Fujii, Xavier Crevoisier, Lawrence J. Berglund, Kristin D. Zhao, Kenton R. Kaufman, Kai-Nan An