Bernd Wegener
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bernd Wegener has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
Volkmar Jansson
Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, Ludwig-Maximilians-University Munich, Munich, Germany
11 shared publications- Christof Birkenmaier
LMU Klinikum, Munich, Germany
9 shared publications - Volkmar Jansson
Department of Orthopaedics, Physical Medicine and Rehabilitation, University Hospital, LMU Munich, Marchioninistraße 15, 81377 Munich, Germany
5 shared publications - Andreas Büttner
Institute of Forensic Medicine, Rostock University Medical Center, St.-Georg-Str. 108, 18055 Rostock, Germany
3 shared publications - Carolin Melcher
University Hospital
3 shared publications Christof Birkenmaier
Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, Ludwig-Maximilians-University Munich, Munich, Germany
3 shared publications
Latest Publications
- Open Access
- 21 February 2024
- Published by Springer Nature in Skeletal Radiology
- Vol. 53 (8) , 1517-1528
Distances and angles in standing long-leg radiographs: comparing conventional radiography, digital radiography, and EOS
Objective: Distances and angles measured from long-leg radiographs (LLR) are important for surgical decision-making. However, projectional radiography suffers from distortion, potentially generating differences between measurement and true anatomical dimension. These phenomena are not uniform between conventional radiography (CR) digital radiography (DR) and fan-beam technology (EOS). We aimed to identify differences between these modalities in an experimental setup. Materials and methods: A hemiskeleton was stabilized using an external fixator in neutral, valgus and varus knee alignment. Ten images were acquired for each alignment and each modality: one CR setup, two different DR systems, and an EOS. A total of 1680 measurements were acquired and analyzed. Results: We observed great differences for dimensions and angles between the 4 modalities. Femoral head diameter measurements varied in the range of > 5 mm depending on the modality, with EOS being the closest to the true anatomical dimension. With functional leg length, a difference of 8.7% was observed between CR and EOS and with the EOS system being precise in the vertical dimension on physical-technical grounds, this demonstrates significant projectional magnification with CR-LLR. The horizontal distance between the medial malleoli varied by 20 mm between CR and DR, equating to 21% of the mean. Conclusions: Projectional distortion resulting in variations approaching 21% of the mean indicate, that our confidence on measurements from standing LLR may not be justified. It appears likely that among the tested equipment, EOS-generated images are closest to the true anatomical situation most of the time.
- 21 February 2024
- Published by Springer Nature in Skeletal Radiology
- Vol. 53 (8) , 1517-1528
Open AccessDistances and angles in standing long-leg radiographs: comparing conventional radiography, digital radiography, and EOS
Objective: Distances and angles measured from long-leg radiographs (LLR) are important for surgical decision-making. However, projectional radiography suffers from distortion, potentially generating differences between measurement and true anatomical dimension. These phenomena are not uniform between conventional radiography (CR) digital radiography (DR) and fan-beam technology (EOS). We aimed to identify differences between these modalities in an experimental setup. Materials and methods: A hemiskeleton was stabilized using an external fixator in neutral, valgus and varus knee alignment. Ten images were acquired for each alignment and each modality: one CR setup, two different DR systems, and an EOS. A total of 1680 measurements were acquired and analyzed. Results: We observed great differences for dimensions and angles between the 4 modalities. Femoral head diameter measurements varied in the range of > 5 mm depending on the modality, with EOS being the closest to the true anatomical dimension. With functional leg length, a difference of 8.7% was observed between CR and EOS and with the EOS system being precise in the vertical dimension on physical-technical grounds, this demonstrates significant projectional magnification with CR-LLR. The horizontal distance between the medial malleoli varied by 20 mm between CR and DR, equating to 21% of the mean. Conclusions: Projectional distortion resulting in variations approaching 21% of the mean indicate, that our confidence on measurements from standing LLR may not be justified. It appears likely that among the tested equipment, EOS-generated images are closest to the true anatomical situation most of the time.
- 2 February 2022
- Published by Elsevier in Clinical Biomechanics
- Vol. 92, 105589
Experimental measurements of micromotions of the cementless intervertebral disc prostheses in the cadaver bone
- 2 February 2022
- Published by Elsevier in Clinical Biomechanics
- Vol. 92, 105589
Experimental measurements of micromotions of the cementless intervertebral disc prostheses in the cadaver bone
- 24 January 2022
- Published by Elsevier in Clinical Biomechanics
- Vol. 92, 105578
Biomechanical comparisons of three minimally invasive Achilles tendon percutaneous repair suture techniques
- 24 January 2022
- Published by Elsevier in Clinical Biomechanics
- Vol. 92, 105578
Biomechanical comparisons of three minimally invasive Achilles tendon percutaneous repair suture techniques
- Open Access
- 8 June 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Local and systemic inflammation after implantation of a novel iron based porous degradable bone replacement material in sheep model
Despite the high potential of healthy bone to regenerate, the reconstruction of large bone defects remains a challenge. Due to the lack of mechanical stability of existing bone substitutes, recently developed degradable metallic alloys are an interesting alternative providing higher load-bearing capabilities. Degradable iron-based alloys therefore might be an attractive innovation. To test the suitability of a newly-designed iron-based alloy for such applications, an animal experiment was performed. Porous iron-based degradable implants with two different densities and a control group were tested. The implants were positioned in the proximal tibia of Merino sheep. Over a period of 6 and 12 months, blood and histological parameters were monitored for signs of inflammation and degradation. In the histological evaluation of the implants` environment we found degraded alloy particles, but no inflammatory reaction. Iron particles were also found within the popliteal lymph nodes on both sides. The serum blood levels of phosphorus, iron and ferritin in the long term groups were elevated. Other parameters did not show any changes. Iron-based degradable porous bone replacement implants showed a good biocompatibility in this experiment. For a clinical application, however, the rate of degradation would have to be significantly increased. Biocompatibility would then have to be re-evaluated.
- 8 June 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Open AccessLocal and systemic inflammation after implantation of a novel iron based porous degradable bone replacement material in sheep model
Despite the high potential of healthy bone to regenerate, the reconstruction of large bone defects remains a challenge. Due to the lack of mechanical stability of existing bone substitutes, recently developed degradable metallic alloys are an interesting alternative providing higher load-bearing capabilities. Degradable iron-based alloys therefore might be an attractive innovation. To test the suitability of a newly-designed iron-based alloy for such applications, an animal experiment was performed. Porous iron-based degradable implants with two different densities and a control group were tested. The implants were positioned in the proximal tibia of Merino sheep. Over a period of 6 and 12 months, blood and histological parameters were monitored for signs of inflammation and degradation. In the histological evaluation of the implants` environment we found degraded alloy particles, but no inflammatory reaction. Iron particles were also found within the popliteal lymph nodes on both sides. The serum blood levels of phosphorus, iron and ferritin in the long term groups were elevated. Other parameters did not show any changes. Iron-based degradable porous bone replacement implants showed a good biocompatibility in this experiment. For a clinical application, however, the rate of degradation would have to be significantly increased. Biocompatibility would then have to be re-evaluated.
- Open Access
- 20 January 2021
- Published by Springer Nature in Research Square
Local and Systemic Inflammation After Implantation of a Novel Iron Based Porous Degradable Bone Replacement Material in Sheep Model
Despite a high regenerative potential of healthy bone, replacement of large bone defects is an currently ongoing medical challenge. Due to a lack of mechanical stability of existing bone substitutes, recently developed degradable metallic alloys are an interesting alternative providing higher load bearing properties. Degradable iron-based alloys are an attractive innovation. Therefore, a degradable iron-based bone replacement material has been developed.To test the suitability of a newly designed iron-based alloy, an animal experiment was performed. Porous iron-based degradable implants with two different densities and a control group were tested. The implants were positioned in the proximal tibia. Over a period of 6 and 12 months, blood and histological parameters were monitored for signs of inflammation and degradation. Even if degradation at the desired rate was not achieved, in the histological evaluation of the implants` environment we found degraded particles, but no inflammatory reaction. Iron particles were also found within the popliteal lymph nodes on both sides. The serum blood levels of phosphorus, iron and ferritin in the long term groups were elevated. Other parameters did not show any changes.Iron-based degradable porous bone replacement implants showed a good biocompatibility in this experiment. For a clinical application, however, the rate of degradation would have to be significantly increased. Biocompatibility would then have to be re-evaluated.
- 20 January 2021
- Published by Springer Nature in Research Square
Open AccessLocal and Systemic Inflammation After Implantation of a Novel Iron Based Porous Degradable Bone Replacement Material in Sheep Model
Despite a high regenerative potential of healthy bone, replacement of large bone defects is an currently ongoing medical challenge. Due to a lack of mechanical stability of existing bone substitutes, recently developed degradable metallic alloys are an interesting alternative providing higher load bearing properties. Degradable iron-based alloys are an attractive innovation. Therefore, a degradable iron-based bone replacement material has been developed.To test the suitability of a newly designed iron-based alloy, an animal experiment was performed. Porous iron-based degradable implants with two different densities and a control group were tested. The implants were positioned in the proximal tibia. Over a period of 6 and 12 months, blood and histological parameters were monitored for signs of inflammation and degradation. Even if degradation at the desired rate was not achieved, in the histological evaluation of the implants` environment we found degraded particles, but no inflammatory reaction. Iron particles were also found within the popliteal lymph nodes on both sides. The serum blood levels of phosphorus, iron and ferritin in the long term groups were elevated. Other parameters did not show any changes.Iron-based degradable porous bone replacement implants showed a good biocompatibility in this experiment. For a clinical application, however, the rate of degradation would have to be significantly increased. Biocompatibility would then have to be re-evaluated.
- Open Access
- 21 August 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (8) , e0236780
The effects of whole-body electromyostimulation (WB-EMS) in comparison to a multimodal treatment concept in patients with non-specific chronic back pain—A prospective clinical intervention study
According to present guidelines, active exercise is one key component in the comprehensive treatment of nonspecific chronic back pain (NSCBP). Whole body electromyostimulation (WB-EMS) is a safe, and time-effective training method, that may be effective in NSCBP-patients. In this prospective and controlled nonrandomized clinical study, two therapeutic approaches were compared. One group received 20 minutes WB-EMS per week. An active control group (ACG) received a multimodal therapy program. A third group included subjects without back pain. To all groups, the following measurement instruments were applied: Numeric Rating Scale (NRS), Oswestry Disability Index (ODI), North American Spine Society Instrument (NASS); SF 36 survey and measurements for muscular function and postural stability. In the EMS-group: T0: baseline; T1: at 6 weeks; T2: at 12 weeks and T3: at 24 weeks. In the ACG: T0 baseline and T1 after 4 weeks. In the intervention group, 128 patients with low back pain were enrolled, 85 in the WB-EMS group and 43 in the ACG. 34 subjects were allocated to the passive control group. The average age was 58.6 years (18–86 years). In the EMS group, the NRS (1–10) improved statistically and clinically significantly by 2 points. The ODI was reduced by 19.7 points. The NASS and most of the SF 36 items improved significantly. In the multimodal treatment group, only the muscular function improved slightly. Our data support the hypothesis that WB-EMS is at least as effective as a multimodal treatment, which is often referred to as being the golden standard. Therefore WB-EMS may be an effective and, with 20 min./week training time, very time-efficient alternative to established multimodal treatment models.
- 21 August 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (8) , e0236780
Open AccessThe effects of whole-body electromyostimulation (WB-EMS) in comparison to a multimodal treatment concept in patients with non-specific chronic back pain—A prospective clinical intervention study
According to present guidelines, active exercise is one key component in the comprehensive treatment of nonspecific chronic back pain (NSCBP). Whole body electromyostimulation (WB-EMS) is a safe, and time-effective training method, that may be effective in NSCBP-patients. In this prospective and controlled nonrandomized clinical study, two therapeutic approaches were compared. One group received 20 minutes WB-EMS per week. An active control group (ACG) received a multimodal therapy program. A third group included subjects without back pain. To all groups, the following measurement instruments were applied: Numeric Rating Scale (NRS), Oswestry Disability Index (ODI), North American Spine Society Instrument (NASS); SF 36 survey and measurements for muscular function and postural stability. In the EMS-group: T0: baseline; T1: at 6 weeks; T2: at 12 weeks and T3: at 24 weeks. In the ACG: T0 baseline and T1 after 4 weeks. In the intervention group, 128 patients with low back pain were enrolled, 85 in the WB-EMS group and 43 in the ACG. 34 subjects were allocated to the passive control group. The average age was 58.6 years (18–86 years). In the EMS group, the NRS (1–10) improved statistically and clinically significantly by 2 points. The ODI was reduced by 19.7 points. The NASS and most of the SF 36 items improved significantly. In the multimodal treatment group, only the muscular function improved slightly. Our data support the hypothesis that WB-EMS is at least as effective as a multimodal treatment, which is often referred to as being the golden standard. Therefore WB-EMS may be an effective and, with 20 min./week training time, very time-efficient alternative to established multimodal treatment models.
- Open Access
- 4 June 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-10
Development of a novel biodegradable porous iron-based implant for bone replacement
Bone replacement and osteosynthesis require materials which can at least temporarily bear high mechanical loads. Ideally, these materials would eventually degrade and would be replaced by bone deposited from the host organism. To date several metals, notably iron and iron-based alloys have been identified as suitable materials because they combine high strength at medium corrosion rates. However, currently, these materials do not degrade within an appropriate amount of time. Therefore, the aim of the present study is the development of an iron-based degradable sponge-like (i.e. cellular) implant for bone replacement with biomechanically tailored properties. We used a metal powder sintering approach to manufacture a cylindrical cellular implant which in addition contains phosphor as an alloying element. No corrosion inhibiting effects of phosphorus have been found, the degradation rate was not altered. Implant prototypes were tested in an animal model. Bone reaction was investigated at the bone-implant-interface and inside the cellular spaces of the implant. Newly formed bone was growing into the cellular spaces of the implant after 12 months. Signs of implant degradation were detected but after 12 months, no complete degradation could be observed. In conclusion, iron-based open-porous cellular biomaterials seem promising candidates for the development of self-degrading and high load bearing bone replacement materials.
- 4 June 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-10
Open AccessDevelopment of a novel biodegradable porous iron-based implant for bone replacement
Bone replacement and osteosynthesis require materials which can at least temporarily bear high mechanical loads. Ideally, these materials would eventually degrade and would be replaced by bone deposited from the host organism. To date several metals, notably iron and iron-based alloys have been identified as suitable materials because they combine high strength at medium corrosion rates. However, currently, these materials do not degrade within an appropriate amount of time. Therefore, the aim of the present study is the development of an iron-based degradable sponge-like (i.e. cellular) implant for bone replacement with biomechanically tailored properties. We used a metal powder sintering approach to manufacture a cylindrical cellular implant which in addition contains phosphor as an alloying element. No corrosion inhibiting effects of phosphorus have been found, the degradation rate was not altered. Implant prototypes were tested in an animal model. Bone reaction was investigated at the bone-implant-interface and inside the cellular spaces of the implant. Newly formed bone was growing into the cellular spaces of the implant after 12 months. Signs of implant degradation were detected but after 12 months, no complete degradation could be observed. In conclusion, iron-based open-porous cellular biomaterials seem promising candidates for the development of self-degrading and high load bearing bone replacement materials.
- Open Access
- 10 September 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 1136
The Influence of WB-EMS-Training on the Performance of Ice Hockey Players of Different Competitive Status
Purpose: The aim of this study was to examine the influence of long-term whole-body electromyostimulation (WB-EMS) training in addition to standard ice hockey training in the following areas: shot speed, counter-movement-jump (CMJ) height and power, 10 m-sprint, isokinetic maximum force at 60 and 300°/s of the knee extensor muscle and subjective performance. The purpose was further to check, whether competitive status influenced the extent of response to WB-EMS and whether WB-EMS would hypothetically be a suitable method to reduce injury rate. Methods: Thirty male amateur ice hockey players participated in this study. They were divided into two cross-over groups (Group A and Group B). EMS sessions were carried out once a week for 12 weeks for each group with a subsequent 4 week EMS pause. The sessions consisted of 20 min electromyostimulation with 150 contractions (4 s duration, 85 Hz). Shot speed of slap shot was measured with Sportradar 1503. Jumping ability was determined with a ground reaction force platform (GRFP). Sprint time for 10 m skate was recorded using an infrared photo sensor. Isokinetic force of the knee extensor muscle was detected with Isomed 2000 at two different angular velocities (60 and 300°/s) and the subjective performance was collected using a questionnaire. Results: After 12 weeks of WB-EMS training jumping power increased significantly for the WB-EMS groups by 5.15%, 10 m skating time decreased significantly by 5%, and maximum isokinetic force at 300°/s increased significantly by 7% (all p < 0.05). In contrast post training shot speed showed no significant change. Isokinetic torque at 60°/s and vertical jump height were collected as secondary variables and showed increases of 5.45 and 15.15%, respectively. After finishing the WB-EMS and continuing the normal training, it was shown that the training effect regressed. Conclusion: This study demonstrated that WB-EMS training significantly decreased 10 m skating time and increased jumping power and maximum isokinetic force at 300°/s. We conclude that with additional WB-EMS training, an increase in performance might also be achieved for athletes in lower leagues. Due to the higher training potential of leisure athletes, the effect is probably even more pronounced than would be expected for competitive athletes.
- 10 September 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 1136
Open AccessThe Influence of WB-EMS-Training on the Performance of Ice Hockey Players of Different Competitive Status
Purpose: The aim of this study was to examine the influence of long-term whole-body electromyostimulation (WB-EMS) training in addition to standard ice hockey training in the following areas: shot speed, counter-movement-jump (CMJ) height and power, 10 m-sprint, isokinetic maximum force at 60 and 300°/s of the knee extensor muscle and subjective performance. The purpose was further to check, whether competitive status influenced the extent of response to WB-EMS and whether WB-EMS would hypothetically be a suitable method to reduce injury rate. Methods: Thirty male amateur ice hockey players participated in this study. They were divided into two cross-over groups (Group A and Group B). EMS sessions were carried out once a week for 12 weeks for each group with a subsequent 4 week EMS pause. The sessions consisted of 20 min electromyostimulation with 150 contractions (4 s duration, 85 Hz). Shot speed of slap shot was measured with Sportradar 1503. Jumping ability was determined with a ground reaction force platform (GRFP). Sprint time for 10 m skate was recorded using an infrared photo sensor. Isokinetic force of the knee extensor muscle was detected with Isomed 2000 at two different angular velocities (60 and 300°/s) and the subjective performance was collected using a questionnaire. Results: After 12 weeks of WB-EMS training jumping power increased significantly for the WB-EMS groups by 5.15%, 10 m skating time decreased significantly by 5%, and maximum isokinetic force at 300°/s increased significantly by 7% (all p < 0.05). In contrast post training shot speed showed no significant change. Isokinetic torque at 60°/s and vertical jump height were collected as secondary variables and showed increases of 5.45 and 15.15%, respectively. After finishing the WB-EMS and continuing the normal training, it was shown that the training effect regressed. Conclusion: This study demonstrated that WB-EMS training significantly decreased 10 m skating time and increased jumping power and maximum isokinetic force at 300°/s. We conclude that with additional WB-EMS training, an increase in performance might also be achieved for athletes in lower leagues. Due to the higher training potential of leisure athletes, the effect is probably even more pronounced than would be expected for competitive athletes.
- Open Access
- 21 April 2015
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 1-6
Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?
Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for the clinical indication of the examined cementless cups in osteoporotic bone.
- 21 April 2015
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 1-6
Open AccessDoes osteoporosis reduce the primary tilting stability of cementless acetabular cups?
Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for the clinical indication of the examined cementless cups in osteoporotic bone.
- 24 July 2013
- Vol. 16 (4) , 335-44
The current state of endoscopic disc surgery: review of controlled studies comparing full-endoscopic procedures for disc herniations to standard procedures.
Neuropathic pain originating from spinal disc herniations is a very common problem. The majority of disc surgeries are performed to alleviate this pain once conservative measures and targeted injections have failed. Endoscopic spinal surgery is increasingly popular because it minimizes access trauma and hastens recovery from the intervention. This clinically oriented review evaluates controlled studies that investigate the clinical results and the complications of full-endoscopic lumbar and cervical procedures for symptomatic disc herniations in comparison to a microsurgical standard procedure. This review focuses exclusively on modern, full-endoscopic disc surgery irrespective of the specific access technique (e.g., interlaminar vs. transforaminal) and irrespective of the spinal region. Comprehensive review of the literature. To assess the clinical outcomes and complication rates of full-endoscopic disc surgery compared to the microsurgical standard procedures. A PubMed and Embase search was performed, considering entries up to January 2013. All 504 results were screened and categorized. Only 4 randomized controlled trials (RCTs) and one controlled studies (CS) could finally be considered for evaluation. All 5 manuscripts were meticulously analyzed with regards to randomization mode, inclusion/exclusion criteria, clinical results, and complication rates. Overall, the endoscopic techniques had shorter operating times, less blood loss, less operative site pain, and faster postoperative rehabilitation/shorter hospital stay/faster return to work than the microsurgical techniques. There were no significant differences in the main clinical outcome criteria between the endoscopic and the microsurgical techniques in any of the trials. All 5 studies had fewer complications with the endoscopic technique and this was statistically significant in 2 of the studies. One study showed a lower rate of revision surgeries requiring arthrodesis with the endoscopic technique. All 5 studies that could be considered originate from experienced investigators and all 4 RCTs came from one group. This limits the transferability of their results to surgeons less experienced in endoscopic disc surgery. The studies show that full-endoscopic disc surgery can achieve the same clinical results in symptomatic cervical and lumbar disc herniations as the microsurgical standard techniques. This does not appear to come at the price of higher complication rates.
- 24 July 2013
- Vol. 16 (4) , 335-44
The current state of endoscopic disc surgery: review of controlled studies comparing full-endoscopic procedures for disc herniations to standard procedures.
Neuropathic pain originating from spinal disc herniations is a very common problem. The majority of disc surgeries are performed to alleviate this pain once conservative measures and targeted injections have failed. Endoscopic spinal surgery is increasingly popular because it minimizes access trauma and hastens recovery from the intervention. This clinically oriented review evaluates controlled studies that investigate the clinical results and the complications of full-endoscopic lumbar and cervical procedures for symptomatic disc herniations in comparison to a microsurgical standard procedure. This review focuses exclusively on modern, full-endoscopic disc surgery irrespective of the specific access technique (e.g., interlaminar vs. transforaminal) and irrespective of the spinal region. Comprehensive review of the literature. To assess the clinical outcomes and complication rates of full-endoscopic disc surgery compared to the microsurgical standard procedures. A PubMed and Embase search was performed, considering entries up to January 2013. All 504 results were screened and categorized. Only 4 randomized controlled trials (RCTs) and one controlled studies (CS) could finally be considered for evaluation. All 5 manuscripts were meticulously analyzed with regards to randomization mode, inclusion/exclusion criteria, clinical results, and complication rates. Overall, the endoscopic techniques had shorter operating times, less blood loss, less operative site pain, and faster postoperative rehabilitation/shorter hospital stay/faster return to work than the microsurgical techniques. There were no significant differences in the main clinical outcome criteria between the endoscopic and the microsurgical techniques in any of the trials. All 5 studies had fewer complications with the endoscopic technique and this was statistically significant in 2 of the studies. One study showed a lower rate of revision surgeries requiring arthrodesis with the endoscopic technique. All 5 studies that could be considered originate from experienced investigators and all 4 RCTs came from one group. This limits the transferability of their results to surgeons less experienced in endoscopic disc surgery. The studies show that full-endoscopic disc surgery can achieve the same clinical results in symptomatic cervical and lumbar disc herniations as the microsurgical standard techniques. This does not appear to come at the price of higher complication rates.