  • Follow-up of thirty-three computed-tomography-guided percutaneous radiofrequency thermoablations of osteoid osteoma

    by Daniel Neumann, Hans Berka, Ulrich Dorn, Daniel Neureiter, Christoph Thaler

    Purpose This study aimed to determine the mid- and long-term success and complication rates of radiofrequency ablation (RFA) in treatment of osteoid osteoma (OO). Furthermore we were interested in the value of bone biopsy when using a core-drill before the radiofrequency ablation. Methods We retrospectively analysed data of 33 patients (33 osteoid osteomas, 22 males, 11 females) who underwent computed-tomography (CT) guided radiofrequency ablation between 1998 and 2005. The patients had a mean age of 20 years (range, five to 50 years). They were monitored for a mean follow-up of 92 months (range, 60–121 months). Results Lesions were located as follows: 11 cases in the proximal femur, five in the femoral shaft, six in the tibia, one in the calcaneus, two in the metatarsals (second and fourth metatarsals), one in the os cuneiforme mediale, six in the humeral and one in the ulnar shaft. Within the presented time frame 32 of 33 patients were successfully treated and had no more complaints. In one of 33 patients relapse occurred after 28 months and RFA was repeated. There were no complications associated with the procedure. Biopsy obtained prior to thermocoagulation with the help of a core-drill was able to prove diagnosis in all patients (100%). Conclusions These results indicate that the presented technique of CT guided RFA combined with the use of a core-drill for biopsy prior to RFA treatment is a highly effective, efficient, minimally invasive and safe method for the treatment of OO, yielding a success rate of 97% combined with a 100% histological verification of the diagnosis after a minimum follow-up period of five years.


  • Revision total hip arthroplasty using a cementless tapered revision stem in patients with a mean age of 82 years

    by Daniel Neumann, Lothar Dueckelmann, Christoph Thaler, Ulrich Dorn

    A tapered straight cementless stem was used for revision in a group of old and very old patients. We wanted to know whether the use of this implant could achieve satisfactory results despite age and osteoporosis. We retrospectively analysed data of 77 elderly patients (77 hips) who underwent revision in cemented and uncemented primary total hip arthroplasties (THA). The patients had a mean age of 82.2 years (range, 75–92 years) at revision surgery. They were monitored for a mean follow up of 7.1 years (range, 5.0–10.2 years). During the minimum follow-up period 11 patients died of unrelated causes, leaving 66 patients (66 hips) for evaluation. During the period of study three stems failed due to aseptic loosening, three hips dislocated and were successfully treated by closed reduction and bracing. No infection, osteolysis or significant stress shielding around the stems was observed. The survivorship at an average of 7.1-year follow-up was 95.5%. These results indicate that this stem is an excellent alternative in revision THA in patients of 75 years or older.


  • Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting

    by Daniel Neumann, Christoph Thaler, Ulrich Dorn

    Purpose We reviewed our experience with the management of B2 and B3 femoral periprosthetic fractures using a distally fixed modular femoral stem in 55 patients. Methods All periprosthetic fractures were managed immediately after injury without using allograft; 53 hips were available for a mean follow up of 67 months. Results All fractures united, and the mean Harris hip score at the last follow up was 72. Subsidence was noted in two patients (4%) within six months postoperatively and required revision surgery. One patient developed peroneal nerve palsy. Two hips dislocated and were managed by closed reduction. Conclusion In these severe cases of periprosthetic fracture, the technique reviewed here proved to be reliable.


  • Femoral shortening and cementless arthroplasty in Crowe type 4 congenital dislocation of the hip

    by Daniel Neumann, Christoph Thaler, Ulrich Dorn

    Purpose In reconstruction of congenital hip dislocation by total hip arthroplasty (THA), positioning of the acetabular component in the true acetabulum is sometimes accompanied by shortening of the femur. Shortening of the femur is of importance for minimising risk of damaging neurovascular structures due to excessive limb lengthening. Furthermore, reduction of the femoral head into the true acetabulum remains challenging without shortening of the femur. Methods We performed a consecutive case series of cementless THA with femoral shortening and Crowe type 4 congenital dislocation. All acetabular cups were placed in their original anatomical location. In all cases a proximal diaphyseal step-cut shortening osteotomy was performed and stabilised with two to three titanium cerclage bands. Results At an average of 60 months follow-up (range 36–96), 12 patients (13 THA) were scored clinically by the Merle D’Aubigne and Harris hip scores. In ten cases good to excellent outcome scores were observed. During the follow-up period no cases of aseptic loosening, nerve palsy, nonunions or dislocations were found. Conclusions This technique seems to be an excellent treatment option in the case of Crowe type 4 hips presenting with endstage osteoarthritis.


  • Harnblasenperforation durch Migration eines Burch-Schneider-Stützrings

    by D. Neumann, G. Metzner, F. Hofmann, U. Dorn

    Stützringe finden in der Revisionschirurgie großer azetabulärer Defekte breite Anwendung. Wir präsentieren einen Fallbericht eines gelockerten Burch-Schneider-Rings, kombiniert mit Perforation der Harnblase und konsekutiver Makrohämaturie 10 Jahre postoperativ. Nach entsprechender präoperativer Abklärung erfolgten die interdisziplinäre Explantation der Hüftendoprothese sowie die Sanierung des Defekts in der Harnblasenwand. Reinforcement cages are widely used for the treatment of large acetabular bone defects. We report the case of a loosened Burch-Schneider reinforcement ring causing a recurrent macrohaematuria due to a perforation of the urinary bladder. After performing several diagnostic procedures, the patient underwent interdisciplinary revision surgery. Due to the severe destruction of the acetabular bone stock and an infection of the total hip prosthesis as confirmed by fresh frozen section, the hip prosthesis was explanted. At the last follow-up the patient was free of infect-related symptoms and was able to walk with one crutch.