Bernd Füchtmeier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bernd Füchtmeier has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Lukas Prantl
Department for Plastic, Hand & Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany
3 shared publications M. Nerlich
University Clinic
3 shared publicationsJ. Hammer
University of Applied Science
2 shared publicationsM. Maghsudi
Ostholstein Hospital Eutin
2 shared publicationsMichael Nerlich
University Clinic Regensburg
2 shared publicationsR. Hente
Berchtesgaden Municipal Hospital
2 shared publications
Latest Publications
- Open Access
- 22 April 2011
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 12 (1) , 79
Is the rotation of the femural head a potential initiation for cutting out? A theoretical and experimental approach
Since cut-out still remains one of the major clinical challenges in the field of osteoporotic proximal femur fractures, remarkable developments have been made in improving treatment concepts. However, the mechanics of these complications have not been fully understood.
- 22 April 2011
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 12 (1) , 79
Open AccessIs the rotation of the femural head a potential initiation for cutting out? A theoretical and experimental approach
Since cut-out still remains one of the major clinical challenges in the field of osteoporotic proximal femur fractures, remarkable developments have been made in improving treatment concepts. However, the mechanics of these complications have not been fully understood.
- Open Access
- 28 June 2007
- Published by Springer Nature in International Orthopaedics
- Vol. 32 (6) , 759-765
The treatment of dislocated humeral head fractures with a new proximal intramedullary nail system
A new proximal humerus nail (Sirus) for the treatment of proximal humerus fractures has become available. This paper presents the clinical and radiological outcome of the first collective study of 36 patients. Evaluation was performed prospectively. An antero-acromial approach was used for all patients. Three fixed-angle screws were inserted in a locking technique. Thirty-six fractures were fixed with the Sirus nail. These were dislocated 2- and 3-part fractures as described by Neer (J Bone Joint Surg 52:1077–1089). Outcomes were evaluated using the Constant score. Of the 36 patients evaluated 23 had sustained a 2-part fracture and 13 a 3-part fracture. The average age at surgery was 71.2 years (range, 30–93). In 75% of the cases, good to very good outcomes were achieved. Outcomes were satisfactory in 13.8% of the cases. Twenty-five fractures were treated in a closed technique. Average operating time was 41 minutes (range, 19–106) with a fluoroscopy time of 0.6 minutes (range, 0.4–2.6). Secondary fragment dislocation occurred in two cases. After 12.1 months the average Constant score was 79.2 (range, 46–100). Initial clinical experience with the Sirus nail indicates that the procedure is straightforward and has a low complication rate. Functional outcomes are predominantly good to very good. Large fragments of the greater tuberosity and 4-part fractures are beyond the scope of this application.
- 28 June 2007
- Published by Springer Nature in International Orthopaedics
- Vol. 32 (6) , 759-765
Open AccessThe treatment of dislocated humeral head fractures with a new proximal intramedullary nail system
A new proximal humerus nail (Sirus) for the treatment of proximal humerus fractures has become available. This paper presents the clinical and radiological outcome of the first collective study of 36 patients. Evaluation was performed prospectively. An antero-acromial approach was used for all patients. Three fixed-angle screws were inserted in a locking technique. Thirty-six fractures were fixed with the Sirus nail. These were dislocated 2- and 3-part fractures as described by Neer (J Bone Joint Surg 52:1077–1089). Outcomes were evaluated using the Constant score. Of the 36 patients evaluated 23 had sustained a 2-part fracture and 13 a 3-part fracture. The average age at surgery was 71.2 years (range, 30–93). In 75% of the cases, good to very good outcomes were achieved. Outcomes were satisfactory in 13.8% of the cases. Twenty-five fractures were treated in a closed technique. Average operating time was 41 minutes (range, 19–106) with a fluoroscopy time of 0.6 minutes (range, 0.4–2.6). Secondary fragment dislocation occurred in two cases. After 12.1 months the average Constant score was 79.2 (range, 46–100). Initial clinical experience with the Sirus nail indicates that the procedure is straightforward and has a low complication rate. Functional outcomes are predominantly good to very good. Large fragments of the greater tuberosity and 4-part fractures are beyond the scope of this application.
- 25 April 2007
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 127 (6) , 441-447
Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants
The biomechanical stability of a newly developed humerus nail (Sirus™) for the treatment of fractures of the proximal humerus was analyzed in comparison to established systems. In total, three randomized groups were formed (n = 4 pairs) from 12 matched pairs of human cadaver humeri.
- 25 April 2007
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 127 (6) , 441-447
Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants
The biomechanical stability of a newly developed humerus nail (Sirus™) for the treatment of fractures of the proximal humerus was analyzed in comparison to established systems. In total, three randomized groups were formed (n = 4 pairs) from 12 matched pairs of human cadaver humeri.
- 11 October 2006
- Published by SAGE Publications in Technology and Health Care
- Vol. 14 (4-5) , 261-270
A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures
A new humerus nail (Sirus™) has become available for the treatment of fractures of the proximal humerus. The aim of the study was the biomechanical comparison of this implant with established systems. 12 matched pairs of human humeri were employed fo
- 11 October 2006
- Published by SAGE Publications in Technology and Health Care
- Vol. 14 (4-5) , 261-270
A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures
A new humerus nail (Sirus™) has become available for the treatment of fractures of the proximal humerus. The aim of the study was the biomechanical comparison of this implant with established systems. 12 matched pairs of human humeri were employed fo
- 1 December 2004
- Published by Springer Nature in Der Unfallchirurg
- Vol. 107 (12) , 1142-1151
Die minimal-invasive Stabilisierung des dorsalen Beckenrings mit dem transiliakalen Fixateur interne (TIFI)
- 1 December 2004
- Published by Springer Nature in Der Unfallchirurg
- Vol. 107 (12) , 1142-1151
Die minimal-invasive Stabilisierung des dorsalen Beckenrings mit dem transiliakalen Fixateur interne (TIFI)