Per Aspenberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Per Aspenberg has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Anna Fahlgren
Department of Clinical and Experimental Medicine, Division of Cell Biology, Linköping University, Linköping, Sweden
5 shared publications - Björn Pasternak
Department of Epidemiology Research, Statens Serum Institut, Copenhagen, Denmark
3 shared publications - Jörgen Åstrand
Department of Orthopaedics, Lund University Hospital, Lund, Sweden
2 shared publications - Lars Johansson
Department of Management and Engineering, Linköping University, Linköping, Sweden
2 shared publications Olena Virchenko
Section for Orthopaedics and Sports Medicine, Department of Neuroscience and Locomotion, Faculty of Health Sciences, Linköping, Sweden
2 shared publications- Pernilla Eliasson
Department of Biomedical and Clinical Sciences Linköping University Linköping Sweden
2 shared publications
Latest Publications
- 1 January 2012
- Vol. 14 (2) , 47-51
Direct ex vivo measurement of the fluid permeability of loose scar tissue.
Fluid flow is important in many biomechanical models, but there is a lack of experimental data that quantifies soft tissue permeability. We measured the tissue permeability in fibrous soft tissue, using a novel technique to obtain specimens by allowing soft tissue to grow into coralline hydroxyapatite scaffoldings implanted between the abdominal muscle layers of rats.
- 1 January 2012
- Vol. 14 (2) , 47-51
Direct ex vivo measurement of the fluid permeability of loose scar tissue.
Fluid flow is important in many biomechanical models, but there is a lack of experimental data that quantifies soft tissue permeability. We measured the tissue permeability in fibrous soft tissue, using a novel technique to obtain specimens by allowing soft tissue to grow into coralline hydroxyapatite scaffoldings implanted between the abdominal muscle layers of rats.
- Top Cited PapersOpen Access
- 19 January 2010
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 25 (2) , 404-414
Teriparatide for acceleration of fracture repair in humans: A prospective, randomized, double-blind study of 102 postmenopausal women with distal radial fractures
Animal experiments show a dramatic improvement in skeletal repair by teriparatide. We tested the hypothesis that recombinant teriparatide, at the 20 µg dose normally used for osteoporosis treatment or higher, would accelerate fracture repair in humans. Postmenopausal women (45 to 85 years of age) who had sustained a dorsally angulated distal radial fracture in need of closed reduction but no surgery were randomly assigned to 8 weeks of once‐daily injections of placebo (n = 34) or teriparatide 20 µg (n = 34) or teriparatide 40 µg (n = 34) within 10 days of fracture. Hypotheses were tested sequentially, beginning with the teriparatide 40 µg versus placebo comparison, using a gatekeeping strategy. The estimated median time from fracture to first radiographic evidence of complete cortical bridging in three of four cortices was 9.1, 7.4, and 8.8 weeks for placebo and teriparatide 20 µg and 40 µg, respectively (overall p = .015). There was no significant difference between the teriparatide 40 µg versus placebo groups (p = .523). In post hoc analyses, there was no significant difference between teriparatide 40 µg versus 20 µg (p = .053); however, the time to healing was shorter in teriparatide 20 µg than placebo (p = .006). The primary hypothesis that teriparatide 40 µg would shorten the time to cortical bridging was not supported. The shortened time to healing for teriparatide 20 µg compared with placebo still may suggest that fracture repair can be accelerated by teriparatide, but this result should be interpreted with caution and warrants further study. © 2010 American Society for Bone and Mineral Research
- 19 January 2010
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 25 (2) , 404-414
Top Cited PapersOpen AccessTeriparatide for acceleration of fracture repair in humans: A prospective, randomized, double-blind study of 102 postmenopausal women with distal radial fractures
Animal experiments show a dramatic improvement in skeletal repair by teriparatide. We tested the hypothesis that recombinant teriparatide, at the 20 µg dose normally used for osteoporosis treatment or higher, would accelerate fracture repair in humans. Postmenopausal women (45 to 85 years of age) who had sustained a dorsally angulated distal radial fracture in need of closed reduction but no surgery were randomly assigned to 8 weeks of once‐daily injections of placebo (n = 34) or teriparatide 20 µg (n = 34) or teriparatide 40 µg (n = 34) within 10 days of fracture. Hypotheses were tested sequentially, beginning with the teriparatide 40 µg versus placebo comparison, using a gatekeeping strategy. The estimated median time from fracture to first radiographic evidence of complete cortical bridging in three of four cortices was 9.1, 7.4, and 8.8 weeks for placebo and teriparatide 20 µg and 40 µg, respectively (overall p = .015). There was no significant difference between the teriparatide 40 µg versus placebo groups (p = .523). In post hoc analyses, there was no significant difference between teriparatide 40 µg versus 20 µg (p = .053); however, the time to healing was shorter in teriparatide 20 µg than placebo (p = .006). The primary hypothesis that teriparatide 40 µg would shorten the time to cortical bridging was not supported. The shortened time to healing for teriparatide 20 µg compared with placebo still may suggest that fracture repair can be accelerated by teriparatide, but this result should be interpreted with caution and warrants further study. © 2010 American Society for Bone and Mineral Research
- Open Access
- 1 January 2009
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 80 (1) , 119-123
Bisphosphonates and implants
- 1 January 2009
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 80 (1) , 119-123
Open AccessBisphosphonates and implants
- Open Access
- 1 January 2009
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 80 (1) , 2-3
Black holes in bone – irresistible attractors of foreign materials?
(2009). Black holes in bone – irresistible attractors of foreign materials? Acta Orthopaedica: Vol. 80, No. 1, pp. 2-3.
- 1 January 2009
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 80 (1) , 2-3
Open AccessBlack holes in bone – irresistible attractors of foreign materials?
(2009). Black holes in bone – irresistible attractors of foreign materials? Acta Orthopaedica: Vol. 80, No. 1, pp. 2-3.
- 18 April 2008
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 466 (7) , 1592-1597
Mechanical Load and BMP Signaling During Tendon Repair: A Role for Follistatin?
Healing of the rat Achilles tendon is sensitive to mechanical loading, and the callus strength is reduced by \( \raise0.5ex\hbox{$\scriptstyle 3$} \kern-0.1em/\kern-0.15em \lower0.25ex\hbox{$\scriptstyle 4$} \) after 14 days, if loading is prevented. Exogenous GDFs stimulate tendon healing. This response is influenced by loading: without loading, cartilage and bone formation is initiated. This implies BMP signaling is crucial during tendon healing and influenced by mechanical loading. We therefore asked if mechanical loading influences the gene expression of the BMP signaling system in intact and healing tendons, and how the BMP signaling system changes during healing. The genes were four BMPs (OP-1/BMP-7, GDF-5/CDMP-1/BMP-14, GDF-6/CDMP-2/BMP-13, and GDF-7/CDMP-3/BMP-12), two receptors (BMPR1b and BMPR2), and the antagonists follistatin and noggin. The Achilles tendon was transected in rats and left to heal. Half of the rats had one Achilles tendon unloaded by injection of Botox in the calf muscles. Ten tendons were analyzed before transection and for each of four time points. All genes except noggin were expressed at all time points, but followed different patterns during healing. Loading strongly decreased the expression of follistatin, which could lead to increased signaling. The BMP system appears involved in tendon maintenance and healing, and may respond to mechanical loading.- 18 April 2008
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 466 (7) , 1592-1597
Mechanical Load and BMP Signaling During Tendon Repair: A Role for Follistatin?
Healing of the rat Achilles tendon is sensitive to mechanical loading, and the callus strength is reduced by \( \raise0.5ex\hbox{$\scriptstyle 3$} \kern-0.1em/\kern-0.15em \lower0.25ex\hbox{$\scriptstyle 4$} \) after 14 days, if loading is prevented. Exogenous GDFs stimulate tendon healing. This response is influenced by loading: without loading, cartilage and bone formation is initiated. This implies BMP signaling is crucial during tendon healing and influenced by mechanical loading. We therefore asked if mechanical loading influences the gene expression of the BMP signaling system in intact and healing tendons, and how the BMP signaling system changes during healing. The genes were four BMPs (OP-1/BMP-7, GDF-5/CDMP-1/BMP-14, GDF-6/CDMP-2/BMP-13, and GDF-7/CDMP-3/BMP-12), two receptors (BMPR1b and BMPR2), and the antagonists follistatin and noggin. The Achilles tendon was transected in rats and left to heal. Half of the rats had one Achilles tendon unloaded by injection of Botox in the calf muscles. Ten tendons were analyzed before transection and for each of four time points. All genes except noggin were expressed at all time points, but followed different patterns during healing. Loading strongly decreased the expression of follistatin, which could lead to increased signaling. The BMP system appears involved in tendon maintenance and healing, and may respond to mechanical loading.- Open Access
- 1 January 2008
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (4) , 459-460
Bisphosphonate-induced fractures: Nature strikes back?
(2008). Bisphosphonate-induced fractures: Nature strikes back? Acta Orthopaedica: Vol. 79, No. 4, pp. 459-460.
- 1 January 2008
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (4) , 459-460
Open AccessBisphosphonate-induced fractures: Nature strikes back?
(2008). Bisphosphonate-induced fractures: Nature strikes back? Acta Orthopaedica: Vol. 79, No. 4, pp. 459-460.
- Open Access
- 1 January 2008
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (4) , 467-473
Fixed or loose? Dichotomy in RSA data for cemented cups
Roentgen stereometric analysis (RSA) cannot discern whether a single prosthesis is fixed or migrating below the detection level. Samples of patients usually show migration values that appear to be continuously distributed. Is there such continuity, or is there a dichotomy between stable and migrating prostheses? The hypothesis of a dichotomy has, to our knowledge, not been tested. We present an exploratory evaluation of such a dichotomy using a mixture distribution algorithm. We analyzed the migration (as determined by RSA) of 147 cemented acetabular cups of 7 different designs by using a new set of algorithms for frequency distribution analysis called Rmix. We first analyzed a migration vector, regardless of direction. After 2 years there was a significant dichotomy between 2 lognormal subgroups within the sample. Although some types of cups were over-represented in one of the subgroups, neither cup design, sex, nor operating department could explain the dichotomy into two groups, which appears to reflect the existence of two basically different types of behavior of the cups. We next analyzed the migration along the 3 axes in space, and found a similar dichotomy. During the second year, around 80% of the patients belonged to a distinct, normally distributed subgroup with a mean not different from 0 mm and a small variation. The remainder differed significantly from this subgroup and showed migration. There is a dichotomy in migration pattern. During the second postoperative year, most cups belonged to a subpopulation that appeared stable. The remainder is probably at risk of loosening. For a single type of prosthesis, the relative size of the stable subgroup may be a good index of the expected performance. The possibility of detecting subgroups within a seemingly continuous sample might be useful in many fields of medicine.
- 1 January 2008
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 79 (4) , 467-473
Open AccessFixed or loose? Dichotomy in RSA data for cemented cups
Roentgen stereometric analysis (RSA) cannot discern whether a single prosthesis is fixed or migrating below the detection level. Samples of patients usually show migration values that appear to be continuously distributed. Is there such continuity, or is there a dichotomy between stable and migrating prostheses? The hypothesis of a dichotomy has, to our knowledge, not been tested. We present an exploratory evaluation of such a dichotomy using a mixture distribution algorithm. We analyzed the migration (as determined by RSA) of 147 cemented acetabular cups of 7 different designs by using a new set of algorithms for frequency distribution analysis called Rmix. We first analyzed a migration vector, regardless of direction. After 2 years there was a significant dichotomy between 2 lognormal subgroups within the sample. Although some types of cups were over-represented in one of the subgroups, neither cup design, sex, nor operating department could explain the dichotomy into two groups, which appears to reflect the existence of two basically different types of behavior of the cups. We next analyzed the migration along the 3 axes in space, and found a similar dichotomy. During the second year, around 80% of the patients belonged to a distinct, normally distributed subgroup with a mean not different from 0 mm and a small variation. The remainder differed significantly from this subgroup and showed migration. There is a dichotomy in migration pattern. During the second postoperative year, most cups belonged to a subpopulation that appeared stable. The remainder is probably at risk of loosening. For a single type of prosthesis, the relative size of the stable subgroup may be a good index of the expected performance. The possibility of detecting subgroups within a seemingly continuous sample might be useful in many fields of medicine.
- 28 November 2007
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 23 (3) , 271-276
Doxycycline-coated sutures improve mechanical strength of intestinal anastomoses
After resection and repair of the intestines, tissue degradation leads to weakening of the repair site and risk of postoperative leakage. Matrix metalloproteinases (MMPs) are thought to be responsible for collagenolysis in the direct vicinity of surgical sutures in many tissues. Several experimental studies show that MMP inhibitors administered systemically alleviate postoperative weakening of intestinal anastomoses. We hypothesised that local delivery of MMP inhibitors would achieve a similar effect. Implementing a novel method for the coating of biomaterials, we coated sutures with a cross-linked fibrinogen film and bound the MMP inhibitor doxycycline into this film. The sutures were then used in a standard rat model for evaluating mechanical properties of colonic anastomoses 3 days after surgery. The breaking strength of the anastomoses on the critical third day after operation was 17% higher with doxycycline-coated sutures compared to controls (P = 0.026). Energy uptake at failure was enhanced by 20% (P = 0.047). Drug delivery by means of MMP-inhibitor-coated sutures appears to improve tissue integrity during anastomotic repair and may reduce postoperative complications.
- 28 November 2007
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 23 (3) , 271-276
Doxycycline-coated sutures improve mechanical strength of intestinal anastomoses
After resection and repair of the intestines, tissue degradation leads to weakening of the repair site and risk of postoperative leakage. Matrix metalloproteinases (MMPs) are thought to be responsible for collagenolysis in the direct vicinity of surgical sutures in many tissues. Several experimental studies show that MMP inhibitors administered systemically alleviate postoperative weakening of intestinal anastomoses. We hypothesised that local delivery of MMP inhibitors would achieve a similar effect. Implementing a novel method for the coating of biomaterials, we coated sutures with a cross-linked fibrinogen film and bound the MMP inhibitor doxycycline into this film. The sutures were then used in a standard rat model for evaluating mechanical properties of colonic anastomoses 3 days after surgery. The breaking strength of the anastomoses on the critical third day after operation was 17% higher with doxycycline-coated sutures compared to controls (P = 0.026). Energy uptake at failure was enhanced by 20% (P = 0.047). Drug delivery by means of MMP-inhibitor-coated sutures appears to improve tissue integrity during anastomotic repair and may reduce postoperative complications.
- Open Access
- 26 November 2007
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 8 (1) , 116
Mechanical properties during healing of Achilles tendon ruptures to predict final outcome: A pilot Roentgen stereophotogrammetric analysis in 10 patients
There are presently few methods described for in vivo monitoring of the mechanics of healing human tendon ruptures, and no methods for prediction of clinical outcome. We tested if Roentgen stereophotogrammetric analysis (RSA) can be used to follow the restoration of mechanical properties during healing of ruptured Achilles tendons, and if early measurements can predict clinical results.
- 26 November 2007
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 8 (1) , 116
Open AccessMechanical properties during healing of Achilles tendon ruptures to predict final outcome: A pilot Roentgen stereophotogrammetric analysis in 10 patients
There are presently few methods described for in vivo monitoring of the mechanics of healing human tendon ruptures, and no methods for prediction of clinical outcome. We tested if Roentgen stereophotogrammetric analysis (RSA) can be used to follow the restoration of mechanical properties during healing of ruptured Achilles tendons, and if early measurements can predict clinical results.