Edward R. Valstar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Edward R. Valstar has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Rob Gerardus Henricus Hubertus Nelissen
Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
9 shared publications - Daniel F. Malan
Department of Orthopaedics, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
3 shared publications - Amir Abbas Zadpoor
Delft University of Technology
2 shared publications - Charl P. Botha
Computer Graphics and Visualization Division of Image Pro- cessing Delft University of Technology Leiden University Medical Center The Netherlands
2 shared publications - Gabriëlle Josephine Maria Tuijthof
Department of Orthopedic Surgery, Academic Medical Centre, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
2 shared publications H.A. Vrooman
Leiden University
2 shared publications
Latest Publications
- 16 April 2019
- Published by ASME International in Journal of Medical Devices
- Vol. 13 (2)
Water Jet Applicator for Interface Tissue Removal in Minimally Invasive Hip Refixation: Testing the Principle and Design of Prototype
Mechanical loosening of implants is in the majority accompanied with a periprosthetic interface membrane, which has to be removed during revision surgery. The same is true if a minimal invasive (percutaneous) refixation of a loose implant is done. We describe the requirements for a waterjet applicator for interface tissue removal for this percutaneous hip refixation technique. The technical requirements were either obtained from a literature review, a theoretical analysis, or by experimental setup. Based on the requirements, a waterjet applicator is designed which is basically a flexible tube (outer diameter 3 mm) with two channels. One channel for the water supply (diameter 0.9 mm) and one for suction to evacuate water and morcellated interface tissue from the periprosthetic cavity. The applicator has a rigid tip (length 6 mm), which directs the water flow to create two waterjets (diameter 0.2 mm), both focused into the suction channel. The functionality of this new applicator is demonstrated by testing a prototype of the applicator tip in an in vitro experimental setup. This testing has shown that the designed applicator for interface tissue removal will eliminate the risk of water pressure buildup; the ejected water was immediately evacuated from the periprosthetic cavity. Blocking of the suction opening was prevented because the jets cut through interface tissue that gets in front of the suction channel. Although further development of the water applicator is necessary, the presented design of the applicator is suitable for interface tissue removal in a minimally invasive hip refixation procedure.
- 16 April 2019
- Published by ASME International in Journal of Medical Devices
- Vol. 13 (2)
Water Jet Applicator for Interface Tissue Removal in Minimally Invasive Hip Refixation: Testing the Principle and Design of Prototype
Mechanical loosening of implants is in the majority accompanied with a periprosthetic interface membrane, which has to be removed during revision surgery. The same is true if a minimal invasive (percutaneous) refixation of a loose implant is done. We describe the requirements for a waterjet applicator for interface tissue removal for this percutaneous hip refixation technique. The technical requirements were either obtained from a literature review, a theoretical analysis, or by experimental setup. Based on the requirements, a waterjet applicator is designed which is basically a flexible tube (outer diameter 3 mm) with two channels. One channel for the water supply (diameter 0.9 mm) and one for suction to evacuate water and morcellated interface tissue from the periprosthetic cavity. The applicator has a rigid tip (length 6 mm), which directs the water flow to create two waterjets (diameter 0.2 mm), both focused into the suction channel. The functionality of this new applicator is demonstrated by testing a prototype of the applicator tip in an in vitro experimental setup. This testing has shown that the designed applicator for interface tissue removal will eliminate the risk of water pressure buildup; the ejected water was immediately evacuated from the periprosthetic cavity. Blocking of the suction opening was prevented because the jets cut through interface tissue that gets in front of the suction channel. Although further development of the water applicator is necessary, the presented design of the applicator is suitable for interface tissue removal in a minimally invasive hip refixation procedure.
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 456-467
Structural and mechanical characterisation of the peri-prosthetic tissue surrounding loosened hip prostheses. An explorative study
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 456-467
Structural and mechanical characterisation of the peri-prosthetic tissue surrounding loosened hip prostheses. An explorative study
- 1 June 2015
- Published by Wiley in Journal of Mechanical Design
- Vol. 137 (6) , 062301
Docking Robustness of Patient Specific Surgical Guides for Joint Replacement Surgery
In joint replacement surgery, patient specific surgical guides (PSSGs) are used for accurate alignment of implant components. PSSGs are designed preoperatively to have a geometric fit with the patient's bone such that the incorporated guidance for drilling and cutting is instantly aligned. The surgeon keeps the PSSG in position with a pushing force, and it is essential that this position is maintained while drilling or cutting. Hence, the influence of the location and direction of the pushing force should be minimal. The extent that the pushing force may vary is what we refer to as docking robustness. In this article, we present a docking robustness framework comprising the following quantitative measures and graphical tool. Contact efficiency ηc is used for the quantification of the selected bone–guide contact. Guide efficiency ηg is used for the quantification of the whole guide including an application surface whereon the surgeon can push. Robustness maps are used to find a robust location for the application surface based on gradient colors. Robustness R is a measure indicating what angular deviation is minimally allowed at the worst point on the application surface. The robustness framework is utilized in an optimization of PSSG dimensions for the distal femur. This optimization shows that 12 contacts already result in a relatively high contact efficiency of 0.74 ± 0.02 (where the maximum of 1.00 is obtained when the guide is designed for full bone–guide contact). Six contacts seem to be insufficient as the obtained contact efficiency is only 0.18 ± 0.02.
- 1 June 2015
- Published by Wiley in Journal of Mechanical Design
- Vol. 137 (6) , 062301
Docking Robustness of Patient Specific Surgical Guides for Joint Replacement Surgery
In joint replacement surgery, patient specific surgical guides (PSSGs) are used for accurate alignment of implant components. PSSGs are designed preoperatively to have a geometric fit with the patient's bone such that the incorporated guidance for drilling and cutting is instantly aligned. The surgeon keeps the PSSG in position with a pushing force, and it is essential that this position is maintained while drilling or cutting. Hence, the influence of the location and direction of the pushing force should be minimal. The extent that the pushing force may vary is what we refer to as docking robustness. In this article, we present a docking robustness framework comprising the following quantitative measures and graphical tool. Contact efficiency ηc is used for the quantification of the selected bone–guide contact. Guide efficiency ηg is used for the quantification of the whole guide including an application surface whereon the surgeon can push. Robustness maps are used to find a robust location for the application surface based on gradient colors. Robustness R is a measure indicating what angular deviation is minimally allowed at the worst point on the application surface. The robustness framework is utilized in an optimization of PSSG dimensions for the distal femur. This optimization shows that 12 contacts already result in a relatively high contact efficiency of 0.74 ± 0.02 (where the maximum of 1.00 is obtained when the guide is designed for full bone–guide contact). Six contacts seem to be insufficient as the obtained contact efficiency is only 0.18 ± 0.02.
- Open Access
Effect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability
Advanced additive manufacturing techniques such as electron beam melting (EBM), can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the current work, EBM porous Ti6Al4V alloy was exposed to an alkali acid heat (AlAcH) treatment to bio-functionalize the surface of the porous structure. Various molar concentrations (3, 5, 10M) and immersion times (6, 24 h) of the alkali treatment were used to determine optimal parameters. The apatite forming ability of the samples was evaluated using simulated body fluid (SBF) immersion testing. The micro-topography and surface chemistry of AlAcH treated samples were evaluated before and after SBF testing using scanning electron microscopy and energy dispersive X-ray spectroscopy. The AlAcH treatment successfully modified the topographical and chemical characteristics of EBM porous titanium surface creating nano-topographical features ranging from 200–300 nm in size with a titania layer ideal for apatite formation. After 1 and 3 week immersion in SBF, there was no Ca or P present on the surface of as manufactured porous titanium while both elements were present on all AlAcH treated samples except those exposed to 3M, 6 h alkali treatment. An increase in molar concentration and/or immersion time of alkali treatment resulted in an increase in the number of nano-topographical features per unit area as well as the amount of titania on the surface.
Open AccessEffect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability
Advanced additive manufacturing techniques such as electron beam melting (EBM), can produce highly porous structures that resemble the mechanical properties and structure of native bone. However, for orthopaedic applications, such as joint prostheses or bone substitution, the surface must also be bio-functionalized to promote bone growth. In the current work, EBM porous Ti6Al4V alloy was exposed to an alkali acid heat (AlAcH) treatment to bio-functionalize the surface of the porous structure. Various molar concentrations (3, 5, 10M) and immersion times (6, 24 h) of the alkali treatment were used to determine optimal parameters. The apatite forming ability of the samples was evaluated using simulated body fluid (SBF) immersion testing. The micro-topography and surface chemistry of AlAcH treated samples were evaluated before and after SBF testing using scanning electron microscopy and energy dispersive X-ray spectroscopy. The AlAcH treatment successfully modified the topographical and chemical characteristics of EBM porous titanium surface creating nano-topographical features ranging from 200–300 nm in size with a titania layer ideal for apatite formation. After 1 and 3 week immersion in SBF, there was no Ca or P present on the surface of as manufactured porous titanium while both elements were present on all AlAcH treated samples except those exposed to 3M, 6 h alkali treatment. An increase in molar concentration and/or immersion time of alkali treatment resulted in an increase in the number of nano-topographical features per unit area as well as the amount of titania on the surface.
- 7 June 2014
- Published by Springer Nature in Skeletal Radiology
- Vol. 43 (11) , 1537-1542
Percutaneous bone cement refixation of aseptically loose hip prostheses: the effect of interface tissue removal on injected cement volumes
To quantify whether injected cement volumes differed between two groups of patients who underwent experimental minimally invasive percutaneous cement injection procedures to stabilize aseptically loose hip prostheses. One patient group was preoperatively treated using gene-directed enzyme prodrug therapy to remove fibrous interface tissue, while the other group received no preoperative treatment. It was hypothesized that cement penetration may have been inhibited by the presence of fibrous interface tissue in periprosthetic lesions. We analyzed 17 patients (14 female, 3 male, ages 72-91, ASA categories 2-4) who were treated at our institution. Osteolytic lesions and injected cement were manually delineated using 3D CT image segmentation, and the deposition of injected cement was quantified. Patients who underwent preoperative gene-directed enzyme therapy to remove fibrous tissue exhibited larger injected cement volumes than those who did not. The observed median increase in injected cement volume was 6.8 ml. Higher cement leakage volumes were also observed for this group. We conclude that prior removal of periprosthetic fibrous interface tissue may enable better cement flow and penetration. This might lead to better refixation of aseptically loosened prostheses.
- 7 June 2014
- Published by Springer Nature in Skeletal Radiology
- Vol. 43 (11) , 1537-1542
Percutaneous bone cement refixation of aseptically loose hip prostheses: the effect of interface tissue removal on injected cement volumes
To quantify whether injected cement volumes differed between two groups of patients who underwent experimental minimally invasive percutaneous cement injection procedures to stabilize aseptically loose hip prostheses. One patient group was preoperatively treated using gene-directed enzyme prodrug therapy to remove fibrous interface tissue, while the other group received no preoperative treatment. It was hypothesized that cement penetration may have been inhibited by the presence of fibrous interface tissue in periprosthetic lesions. We analyzed 17 patients (14 female, 3 male, ages 72-91, ASA categories 2-4) who were treated at our institution. Osteolytic lesions and injected cement were manually delineated using 3D CT image segmentation, and the deposition of injected cement was quantified. Patients who underwent preoperative gene-directed enzyme therapy to remove fibrous tissue exhibited larger injected cement volumes than those who did not. The observed median increase in injected cement volume was 6.8 ml. Higher cement leakage volumes were also observed for this group. We conclude that prior removal of periprosthetic fibrous interface tissue may enable better cement flow and penetration. This might lead to better refixation of aseptically loosened prostheses.
- 10 May 2013
- Published by Wiley in Journal of Mechanical Design
- Vol. 135 (7) , 071001
Shaping Patient Specific Surgical Guides for Arthroplasty to Obtain High Docking Robustness
Patient specific surgical guides (PSSGs) are used in joint replacement surgery to simplify the surgical process and to increase the accuracy in alignment of implant components with respect to the bone. Each PSSG is fabricated patient specifically and fits only in the planned position on the joint surface by the matching shape. During surgery, the surgeon holds the PSSG in the planned position and the incorporated guidance is used in making the essential cuts to fit the implant components. The shape of the PSSG determines its docking robustness (i.e., the range of forces that the surgeon may apply without losing the planned position). Minimal contact between the PSSG and the joint surface is desired, as this decreases the likelihood of interposition with undetected tissues. No analytical method is known from literature where the PSSG shape can be optimized to have high docking robustness and minimal bone-guide contact. Our objective is to develop and validate such an analytical method. The methods of motion restraint, moment labeling and wrench space—applied in robotic grasping and workpart fixturing—are employed in the creation of this new method. The theoretic approach is utilized in an example by optimizing the PSSG shape for one joint surface step-by-step. The PSSGs that arise from these optimization steps are validated with physical experiments. The following design tools for the analytical method are introduced. The optimal location for bone-guide contact and the application surface where the surgeon may push can be found graphically, respectively, by the use of the wrench space map and the application angle map. A quantitative analysis can be conducted using the complementary wrench space metrics and the robustness metric R. Utilization of the analytical method with an example joint surface shows that the PSSG's shape can be optimized. Experimental validation shows that the standard deviation of the error between the measured and calculated angular limits in the docking force is only 0.7 deg. The analytical method provides valid results and thus can be used for the design of PSSGs.
- 10 May 2013
- Published by Wiley in Journal of Mechanical Design
- Vol. 135 (7) , 071001
Shaping Patient Specific Surgical Guides for Arthroplasty to Obtain High Docking Robustness
Patient specific surgical guides (PSSGs) are used in joint replacement surgery to simplify the surgical process and to increase the accuracy in alignment of implant components with respect to the bone. Each PSSG is fabricated patient specifically and fits only in the planned position on the joint surface by the matching shape. During surgery, the surgeon holds the PSSG in the planned position and the incorporated guidance is used in making the essential cuts to fit the implant components. The shape of the PSSG determines its docking robustness (i.e., the range of forces that the surgeon may apply without losing the planned position). Minimal contact between the PSSG and the joint surface is desired, as this decreases the likelihood of interposition with undetected tissues. No analytical method is known from literature where the PSSG shape can be optimized to have high docking robustness and minimal bone-guide contact. Our objective is to develop and validate such an analytical method. The methods of motion restraint, moment labeling and wrench space—applied in robotic grasping and workpart fixturing—are employed in the creation of this new method. The theoretic approach is utilized in an example by optimizing the PSSG shape for one joint surface step-by-step. The PSSGs that arise from these optimization steps are validated with physical experiments. The following design tools for the analytical method are introduced. The optimal location for bone-guide contact and the application surface where the surgeon may push can be found graphically, respectively, by the use of the wrench space map and the application angle map. A quantitative analysis can be conducted using the complementary wrench space metrics and the robustness metric R. Utilization of the analytical method with an example joint surface shows that the PSSG's shape can be optimized. Experimental validation shows that the standard deviation of the error between the measured and calculated angular limits in the docking force is only 0.7 deg. The analytical method provides valid results and thus can be used for the design of PSSGs.
- 1 May 2012
- Published by Elsevier in Gait & Posture
- Vol. 36 (3) , 394-398
Integrated assessment techniques for linking kinematics, kinetics and muscle activation to early migration: A pilot study
- 1 May 2012
- Published by Elsevier in Gait & Posture
- Vol. 36 (3) , 394-398
Integrated assessment techniques for linking kinematics, kinetics and muscle activation to early migration: A pilot study
- Open Access
- 11 April 2012
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 83 (2) , 103-104
Radiostereometry and new prostheses
- 11 April 2012
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 83 (2) , 103-104
Open AccessRadiostereometry and new prostheses
- 17 March 2012
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 20 (12) , 2487-2493
Kinematics of a highly congruent mobile‐bearing total knee prosthesis
Purpose: Limited or absent axial rotation of the mobile insert of total knee prostheses could lead to high contact stresses and stresses at the bone‐implant interface, which in turn might lead to implant loosening. The aim of this study was to assess knee kinematics and muscle activation and their possible change over time in patients with a highly congruent, mobile‐bearing total knee prosthesis.Methods: A prospective series of 11 rheumatoid arthritis patients was included to participate in this fluoroscopic and EMG study; only 7 patients completed the study. Kinematic evaluations took place 7 months, 1 and 2 years post‐operatively. Repeated measurements ANOVA and linear mixed‐effects model for longitudinal data were used to compare the differences between the follow‐ups.Results: There are no significant changes in axial rotations between follow‐up moments for the femoral component as well as the mobile insert. The insert remained mobile and followed the femoral component from 0° until approximately 60° of knee flexion. Diverging and reversed axial rotations and translations were seen during the dynamic motions.Conclusions: Knee kinematics and muscle activation do not appear to change in the first 2 post‐operative years. Reversed and divergent axial rotations with increasing knee flexion indicate that as soon as the congruency decreases, the femoral component is no longer forced in a certain position by the insert and moves to a self‐imposed position. At lower knee flexion angles, the femoral component might be obstructed by the highly congruent insert and therefore might not be able to move freely.Level of evidence: Therapeutic study, Level IV.
- 17 March 2012
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 20 (12) , 2487-2493
Kinematics of a highly congruent mobile‐bearing total knee prosthesis
Purpose: Limited or absent axial rotation of the mobile insert of total knee prostheses could lead to high contact stresses and stresses at the bone‐implant interface, which in turn might lead to implant loosening. The aim of this study was to assess knee kinematics and muscle activation and their possible change over time in patients with a highly congruent, mobile‐bearing total knee prosthesis.Methods: A prospective series of 11 rheumatoid arthritis patients was included to participate in this fluoroscopic and EMG study; only 7 patients completed the study. Kinematic evaluations took place 7 months, 1 and 2 years post‐operatively. Repeated measurements ANOVA and linear mixed‐effects model for longitudinal data were used to compare the differences between the follow‐ups.Results: There are no significant changes in axial rotations between follow‐up moments for the femoral component as well as the mobile insert. The insert remained mobile and followed the femoral component from 0° until approximately 60° of knee flexion. Diverging and reversed axial rotations and translations were seen during the dynamic motions.Conclusions: Knee kinematics and muscle activation do not appear to change in the first 2 post‐operative years. Reversed and divergent axial rotations with increasing knee flexion indicate that as soon as the congruency decreases, the femoral component is no longer forced in a certain position by the insert and moves to a self‐imposed position. At lower knee flexion angles, the femoral component might be obstructed by the highly congruent insert and therefore might not be able to move freely.Level of evidence: Therapeutic study, Level IV.
- Open Access
- 21 January 2012
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 8 (1) , 63-74
Voxel classification and graph cuts for automated segmentation of pathological periprosthetic hip anatomy
Automated patient-specific image-based segmentation of tissues surrounding aseptically loose hip prostheses is desired. For this we present an automated segmentation pipeline that labels periprosthetic tissues in computed tomography (CT). The intended application of this pipeline is in pre-operative planning.
- 21 January 2012
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 8 (1) , 63-74
Open AccessVoxel classification and graph cuts for automated segmentation of pathological periprosthetic hip anatomy
Automated patient-specific image-based segmentation of tissues surrounding aseptically loose hip prostheses is desired. For this we present an automated segmentation pipeline that labels periprosthetic tissues in computed tomography (CT). The intended application of this pipeline is in pre-operative planning.