Naotaka Nitta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Naotaka Nitta has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
Tsuyoshi Shiina
Graduate School of Medicine, Kyoto University, Kyoto, Japan
21 shared publicationsT. Shiina
University of Tsukuba
15 shared publications- Tomokazu Numano
Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10, Higashiogu, Arakawa-ku, Tokyo 116-8551, Japan
15 shared publications Koji Hyodo
Health and Medical Research Institute National Institute of Advanced Industrial Science and Technology (AIST), 1‐2‐1 Namiki Tsukuba Ibaraki 305‐8564 Japan
10 shared publicationsKazuhiro Homma
Human Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST) , Tsukuba, Japan
9 shared publicationsIwaki Akiyama
Medical Ultrasound Research Center, Doshisha University, Kyotanabe, Kyoto, Japan
8 shared publications
Latest Publications
- 6 March 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (6)
Effect of refraction at the boundary of curved cartilage tissue on two-layer model-based speed-of-sound measurement
Early diagnosis of knee osteoarthritis is important, and speed of sound is expected as a promising diagnostic index. However, the effects of refraction at cartilage boundaries on speed of sound measurements may not be negligible. In this study, we investigated the effect of refraction at the boundary of curved cartilage tissue on speed of sound measurements using our horizontal two-layer model. Simulation results showed that the mean absolute error in the speed of sound measurements was less than 5 m/s, and the errors were relatively suppressed even for actual curved cartilage tissue with refraction. This suggests that the speed of sound values useful for diagnosis may be obtained even when using a horizontal two-layer model for actual curved cartilage tissue with refraction.
- 6 March 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (6)
Effect of refraction at the boundary of curved cartilage tissue on two-layer model-based speed-of-sound measurement
Early diagnosis of knee osteoarthritis is important, and speed of sound is expected as a promising diagnostic index. However, the effects of refraction at cartilage boundaries on speed of sound measurements may not be negligible. In this study, we investigated the effect of refraction at the boundary of curved cartilage tissue on speed of sound measurements using our horizontal two-layer model. Simulation results showed that the mean absolute error in the speed of sound measurements was less than 5 m/s, and the errors were relatively suppressed even for actual curved cartilage tissue with refraction. This suggests that the speed of sound values useful for diagnosis may be obtained even when using a horizontal two-layer model for actual curved cartilage tissue with refraction.
- 1 March 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (3) , 03SP65
Preliminary study on the speed-of-sound measurement of cartilage tissue based on a two-layer model
Knee osteoarthritis is a serious disease in an aging society, and early diagnosis is crucial because no fundamental treatment currently exists. Cartilage is often modeled as a poroelastic body with a deformable solid matrix saturated with fluid or water, and its water retention capacity is evaluated by the change in fluid content in the poroelastic body over time. In this study, we focus on the speed of sound as an indicator of fluid content. Considering the actual structure including soft and cartilage tissues, we propose a method for measuring the speed of sound in cartilage tissue using the cartilage surface and subchondral bone surface as reflectors. The effectiveness of the proposed method was demonstrated by performing simulations and phantom experiments, and the measured values of the speed of sound coincided well with the true values in both the simulations and phantom experiments.
- 1 March 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (3) , 03SP65
Preliminary study on the speed-of-sound measurement of cartilage tissue based on a two-layer model
Knee osteoarthritis is a serious disease in an aging society, and early diagnosis is crucial because no fundamental treatment currently exists. Cartilage is often modeled as a poroelastic body with a deformable solid matrix saturated with fluid or water, and its water retention capacity is evaluated by the change in fluid content in the poroelastic body over time. In this study, we focus on the speed of sound as an indicator of fluid content. Considering the actual structure including soft and cartilage tissues, we propose a method for measuring the speed of sound in cartilage tissue using the cartilage surface and subchondral bone surface as reflectors. The effectiveness of the proposed method was demonstrated by performing simulations and phantom experiments, and the measured values of the speed of sound coincided well with the true values in both the simulations and phantom experiments.
- 1 March 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP67
Preliminary study on cartilage tissue evaluation based on longitudinal and shear wave speeds
Knee osteoarthritis is a serious disease in an aging society, and as there is currently no fundamental treatment, early diagnosis is extremely important. Cartilage is often modeled as a poroelastic body with a deformable solid matrix saturated with fluid or water, and its water retention capacity is assessed by the changes in the fluid content within the poroelastic body over time. Therefore, in this study, we focused on Poisson’s ratio as an evaluation index for fluid content. A speed-of-sound measurement method using the subchondral bone as a reflector is proposed, and Poisson’s ratio is calculated by combining the speed of sound measured using the aforementioned method with the shear wave speed measured using the time-of-flight method. As a preliminary cartilage evaluation study, we attempted to estimate the Poisson’s ratio of a cartilage phantom. As a result, the fluid content and Poisson’s ratio of the phantom showed a high correlation.
- 1 March 2024
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 63 (3) , 03SP67
Preliminary study on cartilage tissue evaluation based on longitudinal and shear wave speeds
Knee osteoarthritis is a serious disease in an aging society, and as there is currently no fundamental treatment, early diagnosis is extremely important. Cartilage is often modeled as a poroelastic body with a deformable solid matrix saturated with fluid or water, and its water retention capacity is assessed by the changes in the fluid content within the poroelastic body over time. Therefore, in this study, we focused on Poisson’s ratio as an evaluation index for fluid content. A speed-of-sound measurement method using the subchondral bone as a reflector is proposed, and Poisson’s ratio is calculated by combining the speed of sound measured using the aforementioned method with the shear wave speed measured using the time-of-flight method. As a preliminary cartilage evaluation study, we attempted to estimate the Poisson’s ratio of a cartilage phantom. As a result, the fluid content and Poisson’s ratio of the phantom showed a high correlation.
- 15 May 2023
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 62 (SJ) , SJ1055
Ex vivo evaluation of the sensitivity of modified average speed of sound estimation method
The speed of sound (SoS), which is the propagation speed of longitudinal waves, is expected to be effective for the early detection and monitoring of diseases. Several methods that use handheld probes have been proposed to estimate the SoS. In this study, a modified average SoS estimation method, referred to as the improved focusing method, is proposed to increase the accuracy of average SoS estimation. In the proposed method, a plane wave was transmitted, and the center-element position-dependent variations in the SoS estimation were reduced. Ex vivo experiments were conducted using chicken liver to evaluate the applicability and sensitivity of the proposed method to actual tissues. The livers were subjected to continuous temperature changes to induce changes in the SoS. The results suggest that the improved focusing method measures the average SoS accurately as well as small SoS changes of approximately 1.5 m·s−1·°C−1.
- 15 May 2023
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 62 (SJ) , SJ1055
Ex vivo evaluation of the sensitivity of modified average speed of sound estimation method
The speed of sound (SoS), which is the propagation speed of longitudinal waves, is expected to be effective for the early detection and monitoring of diseases. Several methods that use handheld probes have been proposed to estimate the SoS. In this study, a modified average SoS estimation method, referred to as the improved focusing method, is proposed to increase the accuracy of average SoS estimation. In the proposed method, a plane wave was transmitted, and the center-element position-dependent variations in the SoS estimation were reduced. Ex vivo experiments were conducted using chicken liver to evaluate the applicability and sensitivity of the proposed method to actual tissues. The livers were subjected to continuous temperature changes to induce changes in the SoS. The results suggest that the improved focusing method measures the average SoS accurately as well as small SoS changes of approximately 1.5 m·s−1·°C−1.
- 25 April 2022
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 49 (2) , 123-124
Toward the development of new ultrasound diagnostic technologies
- 25 April 2022
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 49 (2) , 123-124
Toward the development of new ultrasound diagnostic technologies
- 12 April 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 48 (7) , 1240-1255
In Vivo Temperature Rise Measurements of Rabbit Liver and Femur Bone Surface Exposed to an Acoustic Radiation Force Impulse
- 12 April 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 48 (7) , 1240-1255
In Vivo Temperature Rise Measurements of Rabbit Liver and Femur Bone Surface Exposed to an Acoustic Radiation Force Impulse
- 23 March 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SG) , SG1023
Basic investigation on identification of tissue composition based on propagation speeds of longitudinal and shear waves
The elastic modulus of tissue as a useful biomarker of disease detection can be quantitatively evaluated based on shear wave speed (SWS) measurements in shear wave elastography. Although the longitudinal wave speed (LWS) is also expected to be a promising biomarker for disease detection, the elasticity is not always dominant because the LWS is affected by the bulk modulus. In other words, LWS and SWS may reflect different tissue properties. Therefore, in this study, based on the improvement in LWS measurement, the relationship between the composition of a phantom mixed with agar and glycerol and ultrasonically measured LWS and SWS was investigated. The LWS had a good sensitivity in detecting glycerol, while the SWS had a good sensitivity in detecting agar. The calculated Poisson’s ratio had a better sensitivity in detecting agar. In conclusion, a simultaneous measurement of LWS and SWS may help identify the tissue composition.
- 23 March 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SG) , SG1023
Basic investigation on identification of tissue composition based on propagation speeds of longitudinal and shear waves
The elastic modulus of tissue as a useful biomarker of disease detection can be quantitatively evaluated based on shear wave speed (SWS) measurements in shear wave elastography. Although the longitudinal wave speed (LWS) is also expected to be a promising biomarker for disease detection, the elasticity is not always dominant because the LWS is affected by the bulk modulus. In other words, LWS and SWS may reflect different tissue properties. Therefore, in this study, based on the improvement in LWS measurement, the relationship between the composition of a phantom mixed with agar and glycerol and ultrasonically measured LWS and SWS was investigated. The LWS had a good sensitivity in detecting glycerol, while the SWS had a good sensitivity in detecting agar. The calculated Poisson’s ratio had a better sensitivity in detecting agar. In conclusion, a simultaneous measurement of LWS and SWS may help identify the tissue composition.
- Open Access
- 20 October 2021
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 48 (4) , 415
Correction to: A review of physical and engineering factors potentially affecting shear wave elastography
- 20 October 2021
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 48 (4) , 415
Open AccessCorrection to: A review of physical and engineering factors potentially affecting shear wave elastography
- 1 October 2021
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 48 (4) , 373-375
On the publication of the special feature on recent progress in basic research useful for the interpretation of ultrasound diagnostic images
- 1 October 2021
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 48 (4) , 373-375
On the publication of the special feature on recent progress in basic research useful for the interpretation of ultrasound diagnostic images
- Open Access
- 28 August 2021
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 48 (4) , 403-414
A review of physical and engineering factors potentially affecting shear wave elastography
It has been recognized that tissue stiffness provides useful diagnostic information, as with palpation as a screening for diseases such as cancer. In recent years, shear wave elastography (SWE), a technique for evaluating and imaging tissue elasticity quantitatively and objectively in diagnostic imaging, has been put into practical use, and the amount of clinical knowledge about SWE has increased. In addition, some guidelines and review papers regarding technology and clinical applications have been published, and the status as a diagnostic technology is in the process of being established. However, there are still unclear points about the interpretation of shear wave speed (SWS) and converted elastic modulus in SWE. To clarify these, it is important to investigate the factors that affect the SWS and elastic modulus. Therefore, physical and engineering factors that potentially affect the SWS and elastic modulus are discussed in this review paper, based on the principles of SWE and a literature review. The physical factors include the propagation properties of shear waves, mechanical properties (viscoelasticity, nonlinearity, and anisotropy), and size and shape of target tissues. The engineering factors include the region of interest depth and signal processing. The aim of this review paper is not to provide an answer to the interpretation of SWS. It is to provide information for readers to formulate and verify the hypothesis for the interpretation. Therefore, methods to verify the hypothesis for the interpretation are also reviewed. Finally, studies on the safety of SWE are discussed.
- 28 August 2021
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 48 (4) , 403-414
Open AccessA review of physical and engineering factors potentially affecting shear wave elastography
It has been recognized that tissue stiffness provides useful diagnostic information, as with palpation as a screening for diseases such as cancer. In recent years, shear wave elastography (SWE), a technique for evaluating and imaging tissue elasticity quantitatively and objectively in diagnostic imaging, has been put into practical use, and the amount of clinical knowledge about SWE has increased. In addition, some guidelines and review papers regarding technology and clinical applications have been published, and the status as a diagnostic technology is in the process of being established. However, there are still unclear points about the interpretation of shear wave speed (SWS) and converted elastic modulus in SWE. To clarify these, it is important to investigate the factors that affect the SWS and elastic modulus. Therefore, physical and engineering factors that potentially affect the SWS and elastic modulus are discussed in this review paper, based on the principles of SWE and a literature review. The physical factors include the propagation properties of shear waves, mechanical properties (viscoelasticity, nonlinearity, and anisotropy), and size and shape of target tissues. The engineering factors include the region of interest depth and signal processing. The aim of this review paper is not to provide an answer to the interpretation of SWS. It is to provide information for readers to formulate and verify the hypothesis for the interpretation. Therefore, methods to verify the hypothesis for the interpretation are also reviewed. Finally, studies on the safety of SWE are discussed.