WSWolfram Steens

Wolfram Steens

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wolfram Steens has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bone remodeling in proximal HA-coated versus uncoated cementless SL-Plus® femoral components: a 5-year follow-up study

    by W. Steens, A. G. Schneeberger, R. Skripitz, P. Fennema, C. Goetze

    Bone resorption at the femoral stem due to stress shielding has been particularly observed secondary to cementless hip replacement. This prospective study of 126 total-hip replacements was performed to examine clinical outcomes and changes in peri-prosthetic bone density after implantation of a double-tapered cementless femoral component manufactured with versus without hydroxyapatite (HA) coating. Sixty-seven femoral components with and 59 femoral components without proximal HA coating were implanted and examined after a mean follow-up of 5.8 (SD 1.1, 2.8–7.8) years. The Harris hip score (HHS) and plain radiographs were used for clinical and radiological follow-up evaluations. Possible changes in peri-prosthetic bone mineral density (BMD) were measured by dual-energy X-ray absorptiometry (DEXA). Clinical outcome, measured by HHS, was similar in both groups. On plain radiographs, significantly less radiolucent lines were observed for the coated implants. DEXA revealed a significant increase in BMD at the proximal zones, along the medial side, and at the stem tips in the coated compared with the non-coated implants. Hydroxyapatite-coated implants yield favorable radiographic characteristics, but no greater clinical benefit after 5 years’ implantation.


  • Open Access

    Clinical and radiological mid-term results of the thrust plate prosthesis

    by W. Steens, R. V.D. Daele, U. Simon, C. Goetze

    Le propos de cette étude est d’évaluer cliniquement et radiologiquement une prothèse plaque (TPP). 53 prothèses plaques ont été évaluées cliniquement grâce au score de Harris et à l’échelle visuelle analogique et radiographiquement avant l’intervention, après la sortie de l’établissement, en post-opératoire avec une moyenne de 8,09 ans (de 4,61 à 9,93 ans). le score de Harris a augmenté de façon significative (p = 0.05) passant de 48 (18–77) à 95 (46–100) points. L’évaluation de la douleur par échelle visuelle analogique (p = 005) a montré une réduction de celle-ci. L’analyse radiographique a montré par contre un potentiel important de liserés sous la prothèse. 16 prothèses montrent des signes radiologiques d’appréciation difficile. ces prothèses démontrent qu’une bonne évolution clinique est possible avec peu de limitations fonctionnelles. La radiographie montre par contre des processus d’adaptation et de modifications osseuses secondaires aux sollicitations biomécaniques. Cette étude permet de penser que la prothèse TPP est une bonne alternative au remplacement de la hanche chez les sujets les plus jeunes. The purpose of this study was to perform an objective clinical and radiological assessment of the thrust plate prosthesis (TPP). Fifty-three prostheses were evaluated clinically using the Harris hip score (HHS), visual analog scale (VAS), and radiographically before surgery, at the time of discharge, and postoperatively after on average of 8.09 (range 4.61–9.93) years. The average HHS significantly ( p ≤ 0.05) improved from 48 (range 18–77) points to 95 (range 46–100) points. The VAS revealed significant ( p ≤ 0.05) reduction of pain at rest and under load. Radiographic analysis showed a considerable potential for osteolysis under the thrust plate. Sixteen prostheses revealed signs of radiolucent zones. In general, there was a good clinical outcome with no major limitations in function. Radiographic changes under the thrust plate indicate an adaptation processes resulting from changed biomechanics. This study suggests that the TPP could be a good alternative in total hip replacement in younger patients.


  • Open Access

    Morselized bone grafting in revision arthroplasty of the knee: A retrospective analysis of 34 reconstructions after 2–9 years

    by Wolfram Steens, Jochen F Loehr, Joachim Wodtke, Alexander Katzer

    Background and purpose Loosening of a total knee replacement may lead to loss of bone, requiring biological reconstruction at revision arthroplasty. Good results have been reported from revision arthroplasty of the hip using impaction bone grafting. We report our results of revision total knee arthroplasty using the same technique. Patients and methods We retrospectively analyzed 30 patients (involving 34 knees) with a mean age of 63 (34–81) years who, between 1994 and 2002, underwent revision arthroplasty of the knee using hinge or rotational knee prostheses (Link) and impaction bone grafting. The average follow-up was 4 (2–9) years and included a questionnaire, a clinical examination, and standardized radiographs. Results 25 patients were satisfied with their results. 10 patients reported no impairment in their activities of daily living attributed to their operation and did not need any walking support. In 5 patients, there were no clear radiographic signs of incorporation of the graft but that did not compromise the outcome. 5 other patients had complications due to aseptic loosening of their prostheses with radiographic failure of the graft, leading to a periprosthetic fracture in 2 cases. Interpretation Our results with impaction bone grafting in knee revision arthroplasty appear to be similar to those obtained by the same technique in revision hip surgery.


  • Chronische Kobaltvergiftung in der Endoprothetik

    by W. Steens, J. F. Loehr, G. von Foerster, A. Katzer

    Dieser Artikel gibt eine Übersicht über die klinischen Symptome und Therapiemaßnahmen bei chronischer Kobaltvergiftung und enthält eine Falldarstellung, bei der eine schwere Metallose, die durch eine unsachgemäße Keramik-Metall-Gleitpaarung verursacht wurde, zu einem nahezu totalen Verlust der Seh- und Hörfähigkeit führte. Die Revision der Keramik-Keramik-Gleitpaarung wurde zur Verbesserung des Offsets bei anhaltendem Hüftschmerz durchgeführt. Hierbei wurde der Keramikkopf gegen einen langen Metallkopf ausgetauscht. In der Folge beklagte der Patient eine zunehmend schmerzhafte Beweglichkeit der revidierten Hüfte. Nach 2 Jahren bemerkte der Patient zudem eine Visusverschlechterung gefolgt von einer Hörminderung. In einer erneuten Revision zeigte sich der Metallkopf nahezu völlig zerstört, das keramische Pfanneninlay wies Abplatzer auf und der Knochen sowie die angrenzenden Gewebeschichten waren massiv von metallischem Abrieb durchsetzt. Zu diesem Zeitpunkt waren die Serum- und Liquorparameter der Legierungsbestandteile, insbesondere des Kobalts, erhöht. Als Therapiemittel bei chronischer Kobaltvergiftung gelten Chelatbildner wie EDTA oder BAL/DMPS. This article outlines symptoms and therapeutic options in chronic cobalt poisoning including a case report in which metallosis caused by a ceramic-metal articular pairing led to almost complete loss of sight and hearing after revision of a total hip prosthesis. At primary revision the firmly incorporated stem was left in place. For a better offset only the head was exchanged from a ceramic to a metal model which articulated with a socket containing a ceramic inlay. Postoperatively, movement of the hip joint became increasingly uncomfortable and painful. After 2 years, the patient started complaining about increasing impairment of his eyesight followed by a gradual loss of hearing. In a second revision, examination of the explanted material showed almost complete deterioration of the metal femoral head and a partially fractured ceramic inlay with extensive contamination of the bone and surrounding soft tissue by metal debris. At the time of revision increasing concentrations of the alloy elements cobalt, chromium, and molybdenum were measured in the serum and liquor. The concentration of cobalt, in particular, was remarkably high. Treatment options in cases with chronic cobalt poisoning include chelation therapy with EDTA or BAL/DMPS.