KHKarin Horsthuis

Karin Horsthuis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Karin Horsthuis has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Magnetic Resonance Enterography for Suspected Inflammatory Bowel Disease in a Pediatric Population

    by Karin Horsthuis, Lissy de Ridder, Anne Mjb Smets, Maarten S van Leeuwen, Marc A Benninga, Roderick Hj Houwen, Annemieke S Littooij, Rutger Aj Nievelstein, Jaap Stoker

    Objectives: The aim of the study was to determine the accuracy of magnetic resonance enterography (MRE) in diagnosing and differentiating pediatric inflammatory bowel disease (IBD). The secondary aims were to determine the accuracy of MRE in grading disease activity and determine the interobserver agreement for individual MRE parameters.Patients and Methods: Pediatric patients scheduled to undergo esophagogastroduodenoscopy, ileocolonoscopy with biopsies, and barium enteroclysis for suspected IBD were included and underwent MRE. MRE images were evaluated by 3 observers. The accuracy of MRE was calculated using the clinical diagnosis based on endoscopic, histopathological, and barium enteroclysis examinations as reference standard.Results: Thirty‐three patients were available for analysis. IBD was correctly diagnosed in, respectively, 61%, 61%, and 91% of the patients by the 3 observers, with a specificity of 80%, 90%, and 60%. Differentiation between Crohn disease (CD) and ulcerative colitis (UC) was accurately done in, respectively, 67%, 53%, and 80% of patients with CD and 0%, 14%, and 43% of patients with UC. Disease activity was understaged on MRE in the majority of patients. Intraclass correlation coefficients for measurements of bowel thickness were 0.52 (observer 1–2; observer 1–3) and 0.34 (observer 2–3). Interobserver agreement on bowel wall enhancement and stenosis was moderate to good (κ 0.59, 0.56, and 0.56 and κ 0.62, 0.32, 0.30, respectively).Conclusions: Sensitivity and specificity values of MRE for diagnosing pediatric IBD were moderate to good. CD, but not UC, was accurately diagnosed by MRE in a large proportion of patients. Activity was understaged in a large proportion of patients. Interobserver agreement for individual MRE parameters was fair to good.


  • Perianal Crohn Disease: Evaluation of Dynamic Contrast-enhanced MR Imaging as an Indicator of Disease Activity

    by Karin Horsthuis, Cristina Lavini, Shandra Bipat, Pieter C. F. Stokkers, Jaap Stoker

    To prospectively determine clinical value of dynamic contrast material-enhanced magnetic resonance (MR) imaging in the evaluation of disease activity in perianal Crohn disease (CD). Patients provided written informed consent. Study approval was waived by an institutional review board. Thirty-three patients with perianal CD underwent pelvic MR imaging; 17 were male (mean age, 37.4 years +/- 10.8 [standard deviation]; age range, 18-54 years) and 16 were female (mean age, 32.0 years +/- 8.3; age range, 16-43 years). Dynamic contrast-enhanced MR imaging was performed; time-intensity curves (TICs) were obtained. Each pixel was classified as one of six predefined TIC shape types. For each MR imaging examination, a region of interest (ROI) was drawn around the fistula on the single section corresponding to the most extensive and most hyperintense lesion; maximum enhancement (ME), slope of enhancement, and TIC shapes were calculated. Absolute and relative numbers of pixels for each curve type were calculated in a two-dimensional ROI. These results were compared with Perianal Disease Activity Index (PDAI), C-reactive protein (CRP) level, an MR imaging-based severity score, and clinical outcome. A Spearman rank correlation test was used to calculate correlation coefficients between dynamic contrast-enhanced MR imaging parameters and reference parameters. A Mann-Whitney U test was used to calculate differences in dynamic contrast-enhanced MR imaging parameters between predefined groups of patients. Significant correlations were found between the absolute amounts of the TIC shape types and PDAI and between ROI volume and PDAI. The ratio of quickly enhancing versus slowly enhancing pixels correlated with higher MR imaging scores as did the ROI volume. The absolute amounts of pixels displaying TIC types 2, 3, 4, and 5 correlated significantly with MR imaging score. CRP level showed a significant correlation with mean ME. Larger numbers of quickly enhancing pixels were observed in patients who needed medication changes or developed new abscesses during follow-up. Dynamic contrast-enhanced MR imaging can help determine disease activity in perianal CD and might be helpful in selecting a subpopulation of patients who should be monitored more closely for development of more extensive disease.


  • Open Access

    Magnetic resonance imaging for evaluation of disease activity in Crohn’s disease: a systematic review

    by Karin Horsthuis, Shandra Bipat, Pieter C. F. Stokkers, Jaap Stoker

    To systematically review the evidence on the accuracy of MRI for grading disease activity in Crohn’s disease (CD). The MEDLINE, EMBASE, CINAHL and Cochrane databases were searched for studies on the accuracy of MRI in grading CD compared to a predefined reference standard. Two independent observers scored all relevant data. Three disease stages were defined: remission, mild and frank disease. The accuracy rates of MRI per disease stage were calculated by means of a random-effects model. Seven studies were included from a search resulting in 253 articles. In total 140 patients (16 patients in remission, 29 with mild disease and 95 with frank disease) were used for data analysis. MRI correctly graded 91% (95% CI: 84–96%) of patients with frank disease, 62% (95% CI: 44–79) of patients with mild disease and 62% (95% CI: 38–84) of patients in remission. MRI more often overstaged than understaged disease activity; MRI overstaged disease activity in 38% of patients in remission, mostly as mild disease. Overstaging of mild disease was observed in 21%, understaging in 17%. MRI correctly grades disease activity in a large proportion of patients with frank disease. For patients in remission or with mild disease, MRI correctly stages disease activity in many patients (62%).


  • Open Access

    Mapping of T1‐values and Gadolinium‐concentrations in MRI as indicator of disease activity in luminal Crohn's disease: A feasibility study

    by Karin Horsthuis, Aart J. Nederveen, Marijn‐Willem de Feiter, Cristina Lavini, Pieter C.F. Stokkers, Jaap Stoker

    Purpose: To determine the feasibility of T1‐mapping and calculation of Gadolinium‐values in luminal Crohn's Disease (CD).Materials and Methods: Nine patients with active CD were included. For each patient disease activity was determined, based on endoscopic and histopathological results. The Crohn's Disease Endoscopic Index of Severity (CDEIS), the Harvey‐Bradshaw index (HBI) and C‐reactive protein (CRP) were also determined as reference standards. T1‐measurements were performed before and after intravenous administration of Gadodiamide in 14 slices in a single breath‐hold using the Look‐Locker (LL) sequence in combination with a segmented three‐dimensional Turbo Field Echo sequence. A Region of Interest (ROI) was drawn around inflamed bowel loops and the mean Gadolinium‐concentration within the ROI was calculated. Gadolinium‐concentrations were compared between patients with mild and marked disease, as determined by the reference standards.Results: Mean Gadolinium‐concentrations were higher in bowel loops of patients with more active disease, as defined by endoscopic and histopathological examination, CRP, and HBI.Conclusion: By using a breath‐hold LL sequence in the bowel quantitative assessment of contrast agent concentration is possible, thus permitting objective evaluation of physiological changes in actively inflamed tissue in an area that suffers from motion problems. J. Magn. Reson. Imaging 2009;29:488–493.


  • S1206 Magnetic Resonance Imaging for Suspected IBD in a Pediatric Population

    by Lissy D. Ridder, Karin Horsthuis, Anne M. Smets, Rutger A.J. Nievelstein, Maarten van Leeuwen, Marc A. Benninga, Roderick Houwen, Jaap Stoker

  • Inflammatory Bowel Disease Diagnosed with US, MR, Scintigraphy, and CT: Meta-analysis of Prospective Studies

    by Karin Horsthuis, Shandra Bipat, Roelof J. Bennink, Jaap Stoker

    To compare, by performing a meta-analysis, the accuracies of ultrasonography (US), magnetic resonance (MR) imaging, scintigraphy, computed tomography (CT), and positron emission tomography (PET) in the diagnosis of inflammatory bowel disease (IBD). MEDLINE, EMBASE, CINAHL, and Cochrane databases were searched for studies on the accuracy of US, MR imaging, scintigraphy, CT, and PET, as compared with a predefined reference standard, in the diagnosis of IBD. Sensitivity and specificity estimates were calculated on per-patient and per-bowel-segment bases by using a bivariate random-effects model. Thirty-three studies, from a search that yielded 1406 articles, were included in the final analysis. Mean sensitivity estimates for the diagnosis of IBD on a per-patient basis were high and not significantly different among the imaging modalities (89.7%, 93.0%, 87.8%, and 84.3% for US, MR imaging, scintigraphy, and CT, respectively). Mean per-patient specificity estimates were 95.6% for US, 92.8% for MR imaging, 84.5% for scintigraphy, and 95.1% for CT; the only significant difference in values was that between scintigraphy and US (P = .009). Mean per-bowel-segment sensitivity estimates were lower: 73.5% for US, 70.4% for MR imaging, 77.3% for scintigraphy, and 67.4% for CT. Mean per-bowel-segment specificity estimates were 92.9% for US, 94.0% for MR imaging, 90.3% for scintigraphy, and 90.2% for CT. CT proved to be significantly less sensitive and specific compared with scintigraphy (P = .006) and MR imaging (P = .037) No significant differences in diagnostic accuracy among the imaging techniques were observed. Because patients with IBD often need frequent reevaluation of disease status, use of a diagnostic modality that does not involve the use of ionizing radiation is preferable.


  • Open Access

    Detection of inflammatory bowel disease: diagnostic performance of cross-sectional imaging modalities

    by Karin Horsthuis, Pieter C. F. Stokkers, Jaap Stoker

    Different cross-sectional imaging techniques can be used as a diagnostic tool for the evaluation of inflammatory bowel disease (IBD). In this report the diagnostic performances of ultrasonography, magnetic resonance imaging and computed tomography in the detection of IBD and the evaluation of known IBD are described, together with a short update on patient preparation and imaging technique of the respective modalities discussed.


  • Feasibility of evaluating Crohn's disease activity at 3.0 Tesla

    by Karin Van Gemert-Horsthuis, Jasper Florie, Daniel W Hommes, Cristina Lavini, Johannes B Reitsma, Sander J Van Deventer, Jaap Stoker

    Purpose: To determine whether abdominal 3.0T MRI can be used for evaluation of Crohn's disease (CD) compared with ileocolonoscopy (CS), and to determine patient preference for MRI as opposed to CS.Materials and Methods: Twenty patients scheduled for CS underwent MRI. At CS, disease severity was graded and the Crohn's Disease Endoscopic Index of Severity (CDEIS) was determined. Radiological grading (by two observers) was compared with endoscopic grading and CDEIS. Patient experience and preference were determined.Results: In respectively 10 (observer 1) and 13 patients (observer 2) exact agreement between radiological and endoscopic grading was found. In respectively 10 and 7 patients radiological and endoscopic grading differed one level. No statistically significant correlation was found between radiological grading and CDEIS. Between bowel wall thickness and CDEIS weak to moderate correlations were found, and between bowel wall enhancement and CDEIS weak correlations were found. All patients preferred MRI over CS.Conclusion: It is feasible to perform abdominal 3.0T MRI using orally administered contrast medium for evaluation of CD, and this method can be considered a patient‐friendly alternative to CS. J. Magn. Reson. Imaging 2006.


  • MRI in Crohn's disease

    by Karin Horsthuis, Cristina Lavini, Jaap Stoker

    Technological developments have extended the role of MRI in the evaluation of the gastrointestinal tract. The potential of MRI to evaluate disease activity in Crohn's disease has been investigated extensively, as MRI has intrinsic advantages over other techniques, including noninvasiveness and the absence of ionizing radiation. For perianal fistulizing disease MRI has become a mainstay in evaluation of disease, as localization and extent of disease can be very well appreciated using both T2‐weighted and T1‐weighted sequences, fat suppression, and intravenous contrast medium. Imaging of the small bowel and colon in Crohn's disease is more complicated due to bowel peristalsis and respiratory movement. However, using fast breathhold sequences and intravenous spasmolytic medication, images of good diagnostic quality can be acquired. To obtain sufficiently distended bowel, which in our estimation is a prerequisite for evaluation of the bowel, MR enteroclysis can be performed. However, applicability of different oral contrast media has been studied, as a noninvasive method for bowel distension would be preferable. Abdominal MRI is a valuable imaging technique for evaluation of luminal, transmural, and extraintestinal manifestations of Crohn's disease as degree of disease activity, presence of luminal pathology (e.g., stenoses), and extraintestinal manifestations of disease (e.g., abscesses, fistulas) can be accurately assessed. J. Magn. Reson. Imaging 2005;22:1–12.