MCMichael Clarius

Michael Clarius

*This is an algorithmically generated author record based on publicly available information.

Michael Clarius has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • R.G. Bitsch

    Department of Orthopaedics, Traumatology and Paraplegiology, Heidelberg University Hospital, Laboratory of Biomechanics and Implant Research, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany

    3 shared publications
  • E. Röhner

    Department of Traumatology and Orthopaedics, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany

    2 shared publications
  • G. Mohr

    Department of Orthopaedic and Trauma Surgery, Vulpius Klinik GmbH, Vulpiusstraße 29, 74906 Bad Rappenau, Germany. address for M. Clarius

    2 shared publications
  • H. Schmitt

    2 shared publications
  • J.B. Seeger

    Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg, Giessen, Germany

    2 shared publications
  • S. Jaeger

    Department of Orthopaedics, Traumatology and Paraplegiology, Heidelberg University Hospital, Laboratory of Biomechanics and Implant Research, Schlierbacher Landstrasse 200a, 69118 Heidelberg, Germany

    2 shared publications

Latest Publications

  • The Effect of Bone Lavage on Femoral Cement Penetration and Interface Temperature During Oxford Unicompartmental Knee Arthroplasty with Cement

    by J.B. Seeger, S. Jaeger, R.G. Bitsch, G. Mohr, E. Röhner, M. Clarius

    Background: Aseptic loosening is the most common cause for revision unicompartmental knee arthroplasty and is associated with failure of the bone-cement or cement-implant interface. The purpose of the present study was to analyze different bone lavage techniques for the bone-cement and cement-implant interfaces of the femoral component and to study the effect of these techniques on cement penetration and on interface temperature. Methods: In an experimental cadaver study, Oxford unicompartmental knee arthroplasty was performed in twenty-four matched-paired knees to study the effect of pulsed lavage compared with syringe lavage on femoral cement penetration and interface temperature. Interface temperature, cement penetration pressure, and ligament tension forces were measured continuously during the procedure, and cement penetration was determined by performing sagittal bone cuts. Results: Cleansing the femoral bone stock with use of pulsed lavage (Group B) led to increased femoral cement penetration (mean, 1428 mm2; 95% confidence interval, 1348 to 1508 mm2) compared with syringe lavage (Group A) (mean, 1128 mm2; 95% confidence interval, 1038 to 1219 mm2) (p < 0.001). Interface temperature was higher in Group B (mean 22.6°C; 95% confidence interval, 20.5°C to 24.1°C) than in Group A (mean, 21.0°C; 95% confidence interval, 19.4°C to 23.0°C) (p = 0.028), but temperatures never reached critical values for thermal damage to the bone. Conclusions: Pulsed lavage leads to an increased femoral cement penetration without the risk of heat necrosis at the bone-cement interface. Clinical Relevance: Pulsed lavage techniques should be strongly considered for use as a routine procedure for unicompartmental knee arthroplasty with cement to increase bone cement penetration of the implant.


  • Minimally invasive unicompartmental knee replacement

    by M. Clarius, P.R. Aldinger, B. Lehner

  • Extended sagittal saw cut significantly reduces fracture load in cementless unicompartmental knee arthroplasty compared to cemented tibia plateaus: an experimental cadaver study

    by J. B. Seeger, D. Haas, S. Jäger, E. Röhner, S. Tohtz, M. Clarius

    Purpose: Periprosthetic tibial plateau fractures represent a rare but serious complication in unicompartmental knee arthroplasty and are associated with extended sagittal tibial bone cuts. These can occur during the surgery, weaken the posterior cortex of the tibia and are associated with periprosthetic tibial plateau fractures. Although excellent long‐term results have been reported with cemented unicompartmental knee arthroplasty, there is high interest in cementless fixation. The aim of the study was to compare fracture loads of cementless and cemented unicompartmental knee arthroplasty.Methods: Tibial components of the Oxford Uni were implanted in six paired fresh‐frozen tibiae with a defined extended saw cut (10°) at the dorsal cortex of each specimen. In one set, surgery was performed with cement fixation, and in the other, cementless components were implanted. Vertical loads were then applied under standardised conditions to fracture the specimens.Results: Median loads of 3.7 (0.7–6.9) kN led to fractures in the cemented group, whereas cementless fixated tibiae fractured with a median load of 1.6 (0.2–4.3) kN (P = 0.02).Conclusion: The loading capacity in tibiae with cementless components is significantly less compared to cemented fixation. The results show that in case of an extended sagittal bone cut patients especially those with poor bone quality who are treated with a cementless unicompartmental knee arthroplasty are at higher risk for periprosthetic tibial fractures.


  • V 21 Steigert die Implantation einer Knieendoprothese bei Gonarthrose die sportliche Aktivität?

    by Jörn Seeger, H. Schmitt, T. Häussler, R.G. Bitsch, M. Krüger, M. Clarius

  • Open Access

    The UniSpacer™: correcting varus malalignment in medial gonarthrosis

    by Michael Clarius, Justus F. Becker, Holger Schmitt, Joern B. Seeger

    While options for operative treatment of leg axis varus malalignment in patients with medial gonarthrosis include several established procedures, such as unicompartmental knee arthroplasty (UKA), total knee arthroplasty (TKA) or high tibial osteotomy (HTO), there has been little focus on a less invasive option introduced more recently: the UniSpacer™ implant, a self-centering, metallic interpositional device for the knee. This study evaluates clinical and radiological results of the UniSpacer™, whether alignment correction can be achieved by UniSpacer™ arthroplasty and alignment change in the first five postoperative years. Anteroposterior long leg stance radiographs of 20 legs were digitally analysed to assess alignment change: two relevant angles and the deviation of the mechanical axis of the leg were analysed before and after surgery. Additionally, the change of the postoperative alignment was determined one and five years postoperatively. Analysing the mechanical tibiofemoral angle, a significant leg axis correction was achieved, with a mean valgus change of 4.7 ± 1.9°; a varus change occurred in the first postoperative year, while there was no significant further change of alignment seen five years after surgery. The UniSpacer™ corrects malalignment in patients with medial gonarthrosis; however, a likely postoperative change in alignment due to implant adaptation to the joint must be considered before implantation. Our results show that good clinical and functional results can be achieved after UniSpacer™ arthroplasty. However, four of 19 knees had to be revised to a TKA or UKA due to persistent pain, which is an unacceptably high revision rate when looking at the alternative treatment options of medial osteoarthritis of the knee.


  • Erste Erfahrungen mit dem Unispacer bei medialer Gonarthrose

    by M. Clarius, H. Schmitt, V. Ewerbeck

    Fragestellung: Klinische und radiologische Frühergebnisse des Unispacer. Methodik: Für die Behandlung der medialen Gonarthrose stehen dem operativ tätigen Orthopäden/Chirurgen im Wesentlichen 3 Verfahren zur Verfügung. Bislang wird neben der arthroskopischen Gelenktoilette und der valgisierenden Umstellungsosteotomie ein unikompartimenteller Kniegelenkersatz durchgeführt. Mit dem Unispacer wurde nun ein neuartiges, sich selbst zentrierendes Gelenkimplantat aus hochglanzpoliertem Cobaltchrom zur Behandlung der medialen Gonarthrose entwickelt. In einer prospektiven klinischen Studie an 10 konsekutiven Patienten (Alter 48–63) mit therapieresistenter, isolierter medialer Gonarthrose Grad 3–4 wurden die klinischen und radiologischen Frühergebnisse nach Unispacerimplantation erfasst. Die klinische Beurteilung erfolgte anhand des American Knee Society Score (AKSS) und Lysholm Score (LS). Ergebnisse: Radiologisch wurde durch die Implantation des Unispacer die Varusstellung um durchschnittlich 5° korrigiert. Klinisch beklagten 6 Patienten nach 6 Wochen neu aufgetretene anteriore Beschwerden bei gleichzeitiger Schmerzfreiheit medial. Die Follow-up-Ergebnisse nach 6 bzw. 12 Monaten stehen bei Antragstellung noch aus. Schlussfolgerung: Als minimal-invasives Verfahren erscheint die Implantation eines Unispacers eine attraktive Behandlungsalternative zur Therapie der isolierten medialen Gonarthrose. Die Indikationsstellung muss jedoch zur Zeit unter strengen Kriterien erfolgen. Kontrollierte Studien sind erforderlich, bevor eine breite Anwendung empfohlen werden kann.