Guido Cozzi
Research Subjects
Guido Cozzi has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
A Severini
23 shared publicationsM Bellomi
22 shared publicationsM Salvetti
5 shared publicationsL F Frigerio
4 shared publicationsM C Castoldi
Divisione di Radiologia Gastroenterologica, Istituto Nazionale Tumori, Milano
4 shared publicationsA Pestalozza
3 shared publications
Latest Publications
- 28 February 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (2) , S39-S40
Abstract No. 100: Colo-Rectal Self Expandable Metallic Stents. A Multicentric Experience
- 28 February 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (2) , S39-S40
Abstract No. 100: Colo-Rectal Self Expandable Metallic Stents. A Multicentric Experience
- 18 February 2006
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 29 (3) , 380-388
Percutaneous Transhepatic Biliary Drainage in the Management of Postsurgical Biliary Leaks in Patients with Nondilated Intrahepatic Bile Ducts
To assess the feasibility of percutaneous transhepatic biliary drainage (PTBD) for the treatment of postsurgical biliary leaks in patients with nondilated intrahepatic bile ducts, its efficacy in restoring the integrity of bile ducts, and technical procedures to reduce morbidity.
- 18 February 2006
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 29 (3) , 380-388
Percutaneous Transhepatic Biliary Drainage in the Management of Postsurgical Biliary Leaks in Patients with Nondilated Intrahepatic Bile Ducts
To assess the feasibility of percutaneous transhepatic biliary drainage (PTBD) for the treatment of postsurgical biliary leaks in patients with nondilated intrahepatic bile ducts, its efficacy in restoring the integrity of bile ducts, and technical procedures to reduce morbidity.
- 27 May 2004
- Published by Springer Nature in Abdominal Radiology
- Vol. 29 (6) , 688-690
Transhepatic contemporary palliation of biliary and duodenal stenoses by means of metallic stents
- 27 May 2004
- Published by Springer Nature in Abdominal Radiology
- Vol. 29 (6) , 688-690
Transhepatic contemporary palliation of biliary and duodenal stenoses by means of metallic stents
- 1 November 1997
- Vol. 94 (5) , 520-3
[The absorbed dose to the gonads in adult patients undergoing defecographic study by digital or traditional radiographic imaging].
Doses to the gonads and skin of adult people were evaluated during the study of functional anorectal disorders with defecography. The radiologic procedure relies heavily on fluoroscopy with lateral and anteroposterior projections for a mean time of 2.4 minutes; the stages of interest are recorded on a mean of 6 films. Absorbed doses to the gonads and to the skin were measured with LiF thermoluminescence dosimeters placed inside and outside the anthropomorphic "Rando" phantom. The administered doses during the different examination phases (anteroposterior and lateral fluoroscopy and radiography) were measured. Digital and conventional radiography were compared. Gonadal absorbed doses in a standard DSI examination were: 5.0 +/- .1 mGy to the right ovary, 25.2 +/- .7 mGy to the left ovary and 2.7 +/- .1 mGy to testes when at the margin of the irradiation field. Doses to gonads and skin are about 15% higher when the examination is performed with conventional radiography. The considerable radiation dose to ovaries shows that defecography can cause radiation-induced genetic effects in women younger than 40 years with a probability of the order of one thousandth of the natural incidence genetic defects. Defecography must be correctly indicated in fertile women, because of the relatively high absorbed dose to ovaries. In fact, the ovaries absorb about twice as many radiations during defecography than radiologic examinations of the lower gastrointestinal tract.
- 1 November 1997
- Vol. 94 (5) , 520-3
[The absorbed dose to the gonads in adult patients undergoing defecographic study by digital or traditional radiographic imaging].
Doses to the gonads and skin of adult people were evaluated during the study of functional anorectal disorders with defecography. The radiologic procedure relies heavily on fluoroscopy with lateral and anteroposterior projections for a mean time of 2.4 minutes; the stages of interest are recorded on a mean of 6 films. Absorbed doses to the gonads and to the skin were measured with LiF thermoluminescence dosimeters placed inside and outside the anthropomorphic "Rando" phantom. The administered doses during the different examination phases (anteroposterior and lateral fluoroscopy and radiography) were measured. Digital and conventional radiography were compared. Gonadal absorbed doses in a standard DSI examination were: 5.0 +/- .1 mGy to the right ovary, 25.2 +/- .7 mGy to the left ovary and 2.7 +/- .1 mGy to testes when at the margin of the irradiation field. Doses to gonads and skin are about 15% higher when the examination is performed with conventional radiography. The considerable radiation dose to ovaries shows that defecography can cause radiation-induced genetic effects in women younger than 40 years with a probability of the order of one thousandth of the natural incidence genetic defects. Defecography must be correctly indicated in fertile women, because of the relatively high absorbed dose to ovaries. In fact, the ovaries absorb about twice as many radiations during defecography than radiologic examinations of the lower gastrointestinal tract.
- 1 July 1995
- Vol. 90, 124-8
[Transcutaneous radiotherapy combined with low dose intraluminal brachytherapy in the treatment of non-operable neoplastic stenoses of the bile ducts].
Percutaneous biliary drainage is an excellent method to relieve the acute symptoms related to neoplastic stenoses of extrahepatic bile ducts. However, survival rates are low and the quality of life of these patients is poor. High dose irradiation--combined with external beams (ERT) and intraluminal brachytherapy (BRT) through percutaneous drainage--allows effective disease control and, therefore, not only higher survival rates but also a much better quality of life when drainage can be removed after bile duct stenosis resolution. March, 1990, through March, 1993, eleven patients (8 with extrahepatic cholangiocarcinomas and 3 with extrinsic tumors) were treated with combined ERT (40-60 Gy, 6-15 MV X-rays) and intraluminal BRT (6-25 Gy, 192Ir wire, LDR). In 8 patients the biliary stenosis was resolved, completely (CR) in 5 and partially (PR) in 3, as shown by posttreatment cholangiography. In 5 patients biliary drainage could be removed for an average 9 months' period; 3 of 11 patients did not respond to treatment at all (NR). Average overall survival was 14 months: 11 months for NR patients and 16.5 months for CR+PR patients. Treatment complications were acceptable: in two patients only treatment had to be discontinued, both during BRT. Two cases of high grade postirradiation stenosis were observed, both resolved with percutaneous cholangioplasthy.
- 1 July 1995
- Vol. 90, 124-8
[Transcutaneous radiotherapy combined with low dose intraluminal brachytherapy in the treatment of non-operable neoplastic stenoses of the bile ducts].
Percutaneous biliary drainage is an excellent method to relieve the acute symptoms related to neoplastic stenoses of extrahepatic bile ducts. However, survival rates are low and the quality of life of these patients is poor. High dose irradiation--combined with external beams (ERT) and intraluminal brachytherapy (BRT) through percutaneous drainage--allows effective disease control and, therefore, not only higher survival rates but also a much better quality of life when drainage can be removed after bile duct stenosis resolution. March, 1990, through March, 1993, eleven patients (8 with extrahepatic cholangiocarcinomas and 3 with extrinsic tumors) were treated with combined ERT (40-60 Gy, 6-15 MV X-rays) and intraluminal BRT (6-25 Gy, 192Ir wire, LDR). In 8 patients the biliary stenosis was resolved, completely (CR) in 5 and partially (PR) in 3, as shown by posttreatment cholangiography. In 5 patients biliary drainage could be removed for an average 9 months' period; 3 of 11 patients did not respond to treatment at all (NR). Average overall survival was 14 months: 11 months for NR patients and 16.5 months for CR+PR patients. Treatment complications were acceptable: in two patients only treatment had to be discontinued, both during BRT. Two cases of high grade postirradiation stenosis were observed, both resolved with percutaneous cholangioplasthy.
- 1 January 1995
- Vol. 89, 91-3
[Use of safety catheter after removal of Kehr's tube in liver transplant patients].
The authors report on the use of a safety catheter when removing the T-tube in the patients with choledocho-choledochal biliary reconstruction after liver transplantation. After T-tube removal, bile may leak into the peritoneal cavity through the catheter insertion site in the biliary wall. Biliary peritonitis, bilomas, subhepatic collections may develop, which are difficult to treat in immunodepressed patients. The safety catheter is used to allow the external drainage of the biliary outflow, if present, and to prevent the complications due to bile collecting in the peritoneal cavity. Moreover, the catheter allows cholangiography and interventional procedures to be performed when necessary. A soft guidewire is inserted into the distal bile duct through the T-tube and pushed into the duodenum. After removing the T-tube, an 8.3-F all-purpose catheter (APD) is placed on the guidewire with the tip just outside the biliary wall. The APD is then connected to a drainage bag allowing the amount of bile eliminated daily to be checked. This maneuver was performed in 24 transplant recipients and the safety catheter correctly positioned in 22 of them (91.6%). The APD was removed 48 hours after insertion in 15 patients with no biliary leakage. In the remaining 7 patients the catheter was left in situ up to 8 days, since biliary leakage was observed (range: 50-400 ml/day). No early or late complications related to this technique were observed.
- 1 January 1995
- Vol. 89, 91-3
[Use of safety catheter after removal of Kehr's tube in liver transplant patients].
The authors report on the use of a safety catheter when removing the T-tube in the patients with choledocho-choledochal biliary reconstruction after liver transplantation. After T-tube removal, bile may leak into the peritoneal cavity through the catheter insertion site in the biliary wall. Biliary peritonitis, bilomas, subhepatic collections may develop, which are difficult to treat in immunodepressed patients. The safety catheter is used to allow the external drainage of the biliary outflow, if present, and to prevent the complications due to bile collecting in the peritoneal cavity. Moreover, the catheter allows cholangiography and interventional procedures to be performed when necessary. A soft guidewire is inserted into the distal bile duct through the T-tube and pushed into the duodenum. After removing the T-tube, an 8.3-F all-purpose catheter (APD) is placed on the guidewire with the tip just outside the biliary wall. The APD is then connected to a drainage bag allowing the amount of bile eliminated daily to be checked. This maneuver was performed in 24 transplant recipients and the safety catheter correctly positioned in 22 of them (91.6%). The APD was removed 48 hours after insertion in 15 patients with no biliary leakage. In the remaining 7 patients the catheter was left in situ up to 8 days, since biliary leakage was observed (range: 50-400 ml/day). No early or late complications related to this technique were observed.
- 1 September 1994
- Vol. 88 (3) , 272-6
[Self-expanding metal stents in the treatment of neoplastic esophageal stenosis. The technic and preliminary results].
Self-expanding metal stents have been recently used for the treatment of neoplastic esophageal stenoses. In our series, nitinol Strecker stents were implanted in ten patients with malignant esophageal intrinsic or extrinsic strictures, as a definitive palliation. Thirteen stents in all were used: two stents were positioned in three patients to recanalize the esophagus. The prostheses could always be inserted in the treated patients and in all of them swallowing was markedly improved. No major early complications were observed after stent insertion. All the stents but one were patent until the patient's death. Two patients are alive and bearing well-functioning stents. Self-expanding metal stents are to be preferred to plastic endoscopic tubes because their caliber is smaller at the time of insertion and they do not require general anesthesia, as endoscopic tubes sometimes require. Moreover, their complication rate is lower for both early and late complications. Tumor ingrowth through the stent mesh with stent occlusion is the major pitfall of these prostheses, together with the impossibility to use them when esophageal fistulas are present: these limitations will be soon overcome when silicone-coated expandable stents are on the market.
- 1 September 1994
- Vol. 88 (3) , 272-6
[Self-expanding metal stents in the treatment of neoplastic esophageal stenosis. The technic and preliminary results].
Self-expanding metal stents have been recently used for the treatment of neoplastic esophageal stenoses. In our series, nitinol Strecker stents were implanted in ten patients with malignant esophageal intrinsic or extrinsic strictures, as a definitive palliation. Thirteen stents in all were used: two stents were positioned in three patients to recanalize the esophagus. The prostheses could always be inserted in the treated patients and in all of them swallowing was markedly improved. No major early complications were observed after stent insertion. All the stents but one were patent until the patient's death. Two patients are alive and bearing well-functioning stents. Self-expanding metal stents are to be preferred to plastic endoscopic tubes because their caliber is smaller at the time of insertion and they do not require general anesthesia, as endoscopic tubes sometimes require. Moreover, their complication rate is lower for both early and late complications. Tumor ingrowth through the stent mesh with stent occlusion is the major pitfall of these prostheses, together with the impossibility to use them when esophageal fistulas are present: these limitations will be soon overcome when silicone-coated expandable stents are on the market.
- 1 April 1994
- Vol. 87 (4) , 460-8
[Digital fluorography in gastroenterological radiology].
The clinical value of two digital fluoroscopy systems not connected to a PACS was investigated and compared with that of conventional radiology. Some critical variables were considered: image intensifier diameter, image definition, examination time, acquisition speed, patient exposure and finally film consumption. The main problems in the use of the digital techniques consisted in the limited size of the examination fields, which was not big enough to demonstrate the whole colon during double contrast enema, and in the difficult representation of the actual size on the image printed on the laser films. Definition was considered as sufficient for GI examinations. The main advantages consisted in acquisition speed, allowing detailed examinations of cervical esophagus, cardias and fistulous tracts, reduced patient dose and finally the real time visualization of the acquired image on the TV monitor.
- 1 April 1994
- Vol. 87 (4) , 460-8
[Digital fluorography in gastroenterological radiology].
The clinical value of two digital fluoroscopy systems not connected to a PACS was investigated and compared with that of conventional radiology. Some critical variables were considered: image intensifier diameter, image definition, examination time, acquisition speed, patient exposure and finally film consumption. The main problems in the use of the digital techniques consisted in the limited size of the examination fields, which was not big enough to demonstrate the whole colon during double contrast enema, and in the difficult representation of the actual size on the image printed on the laser films. Definition was considered as sufficient for GI examinations. The main advantages consisted in acquisition speed, allowing detailed examinations of cervical esophagus, cardias and fistulous tracts, reduced patient dose and finally the real time visualization of the acquired image on the TV monitor.
- 1 November 1992
- Vol. 84 (5) , 626-9
[Percutaneous gastrostomy].
Percutaneous gastrostomy was developed over the last years as an alternative method to surgical and endoscopic procedures, either for enteral feeding or for drainage of secretions or fluid collections communicating with the upper gastrointestinal (GI) tract. January 1990 through January 1992, 15 percutaneous gastrostomies and 2 percutaneous jejunostomies were performed at the Gastroenterologic Radiology Division of INT, Milan, Italy. The catheters were always inserted under local anesthesia, generally using special gastrostomy sets. Catheter insertion was possible in all the patients who underwent the procedure: in 12 cases gastrostomy allowed enteral feeding till the patients died and in 1 case the catheter is still working. In 2 cases the procedure was performed for drainage of gastroenteric secretions and the catheter was left in situ as a definitive palliation. In 1 patient the catheter was removed after draining a collection due to an anastomotic fistula. No major complications were observed in 17 procedures. In our experience, the indication according to which percutaneous gastrostomies and jejunostomies were performed for enteral feeding was always affected by the presence of a stenosis, in the upper GI tract. Other indications to the procedure, for enteral feeding, are functional swallowing disorders. Finally, it must be emphasized that when tight stenoses of the upper GI tract are present, percutaneous gastrostomy is the sole alternative to surgery.
- 1 November 1992
- Vol. 84 (5) , 626-9
[Percutaneous gastrostomy].
Percutaneous gastrostomy was developed over the last years as an alternative method to surgical and endoscopic procedures, either for enteral feeding or for drainage of secretions or fluid collections communicating with the upper gastrointestinal (GI) tract. January 1990 through January 1992, 15 percutaneous gastrostomies and 2 percutaneous jejunostomies were performed at the Gastroenterologic Radiology Division of INT, Milan, Italy. The catheters were always inserted under local anesthesia, generally using special gastrostomy sets. Catheter insertion was possible in all the patients who underwent the procedure: in 12 cases gastrostomy allowed enteral feeding till the patients died and in 1 case the catheter is still working. In 2 cases the procedure was performed for drainage of gastroenteric secretions and the catheter was left in situ as a definitive palliation. In 1 patient the catheter was removed after draining a collection due to an anastomotic fistula. No major complications were observed in 17 procedures. In our experience, the indication according to which percutaneous gastrostomies and jejunostomies were performed for enteral feeding was always affected by the presence of a stenosis, in the upper GI tract. Other indications to the procedure, for enteral feeding, are functional swallowing disorders. Finally, it must be emphasized that when tight stenoses of the upper GI tract are present, percutaneous gastrostomy is the sole alternative to surgery.
- 1 January 1992
- Vol. 83, 109-13
[The radiology of the complications of surgical endoscopy].