Takuji Yamagami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takuji Yamagami has a total of 254 co-authors. Here are the top co-authors by number of shared publications:
Tsunehiko Nishimura
Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural, Kyoto, Japan
46 shared publicationsRika Yoshimatsu
Department of Diagnostic and Interventional Radiology, Kochi Medical School, Kochi University, Kochi, Japan
39 shared publicationsTomohiro Matsumoto
Department of Diagnostic and Interventional Radiology, Kochi Medical School, Kochi University, Nankoku, Kochi, Japan
23 shared publicationsTakeharu Kato
18 shared publicationsT Nishimura
Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan
15 shared publicationsShigeharu Iida
Department of Radiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, 465 Kajii, Kawaramachi-Hirokoji, Kamigyo, Kyoto 602-8566, Japan
13 shared publications
Latest Publications
- Open Access
- 23 April 2026
- Published by Elsevier in Radiology Case Reports
- Vol. 21 (7) , 2856-2860
A case report of transcatheter arterial embolization for extra-renal retroperitoneal angiomyolipoma associated with tuberous sclerosis complex
- 23 April 2026
- Published by Elsevier in Radiology Case Reports
- Vol. 21 (7) , 2856-2860
Open AccessA case report of transcatheter arterial embolization for extra-renal retroperitoneal angiomyolipoma associated with tuberous sclerosis complex
- 17 December 2025
- Published by SAGE Publications in Acta Radiologica
- Vol. 67 (2) , 199-207
Role of computed tomography performed 10 min after computed tomography-guided transthoracic lung biopsy in the management of complicated pneumothorax
Background: Management strategies for small pneumothorax after computed tomography (CT)-guided lung biopsy may vary between institutions, and the approach to follow-up care can differ. Purpose: To evaluate the role of CT imaging performed 10 min after CT-guided lung biopsy in managing complicated small pneumothorax, particularly to assess its progression and guide subsequent treatment decisions. Material and Methods: A retrospective study was conducted on 86 cases of small pneumothorax identified immediately after CT-guided lung biopsy at our institution between January 2016 and December 2023. Small pneumothorax was defined as having insufficient space to insert a needle for aspiration. CT was performed 10 min after biopsy to assess pneumothorax progression, and cases were categorized into three groups: decreased, unchanged, or increased pneumothorax. Subsequent clinical courses and treatments were evaluated. Results: According to CT performed 10 min after biopsy, pneumothorax decreased, unchanged, and increased in 37 (43.0%), 22 (25.6%), and 27 (31.4%) cases, respectively. Three cases (3.5%) with increased pneumothorax required manual aspiration at that time, which resolved within 3 days. In the 59 cases in which pneumothorax decreased or remained unchanged, 58 (98.3%) resolved spontaneously, while one case worsened after 4 days, requiring delayed aspiration. Conclusion: CT performed 10 min following biopsy may be a valuable tool for predicting the course of small pneumothorax. In the absence of worsening, the likelihood of subsequent progression requiring treatment is minimal. Observation for 10 min and performing manual aspiration in cases with worsening pneumothorax may reduce the need for further treatment, contributing to improved patient management.
- 17 December 2025
- Published by SAGE Publications in Acta Radiologica
- Vol. 67 (2) , 199-207
Role of computed tomography performed 10 min after computed tomography-guided transthoracic lung biopsy in the management of complicated pneumothorax
Background: Management strategies for small pneumothorax after computed tomography (CT)-guided lung biopsy may vary between institutions, and the approach to follow-up care can differ. Purpose: To evaluate the role of CT imaging performed 10 min after CT-guided lung biopsy in managing complicated small pneumothorax, particularly to assess its progression and guide subsequent treatment decisions. Material and Methods: A retrospective study was conducted on 86 cases of small pneumothorax identified immediately after CT-guided lung biopsy at our institution between January 2016 and December 2023. Small pneumothorax was defined as having insufficient space to insert a needle for aspiration. CT was performed 10 min after biopsy to assess pneumothorax progression, and cases were categorized into three groups: decreased, unchanged, or increased pneumothorax. Subsequent clinical courses and treatments were evaluated. Results: According to CT performed 10 min after biopsy, pneumothorax decreased, unchanged, and increased in 37 (43.0%), 22 (25.6%), and 27 (31.4%) cases, respectively. Three cases (3.5%) with increased pneumothorax required manual aspiration at that time, which resolved within 3 days. In the 59 cases in which pneumothorax decreased or remained unchanged, 58 (98.3%) resolved spontaneously, while one case worsened after 4 days, requiring delayed aspiration. Conclusion: CT performed 10 min following biopsy may be a valuable tool for predicting the course of small pneumothorax. In the absence of worsening, the likelihood of subsequent progression requiring treatment is minimal. Observation for 10 min and performing manual aspiration in cases with worsening pneumothorax may reduce the need for further treatment, contributing to improved patient management.
- Open Access
- 5 August 2025
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (10) , 5320-5325
Primary temporal bone osteosarcoma presenting as a parotid tumor: A case report with diagnostic challenges
- 5 August 2025
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (10) , 5320-5325
Open AccessPrimary temporal bone osteosarcoma presenting as a parotid tumor: A case report with diagnostic challenges
- Open Access
- 8 March 2025
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (5) , 2338-2341
Late-onset bone granulomatous reaction of hand from immune checkpoint-inhibitors detected on FDG-PET/CT
- 8 March 2025
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (5) , 2338-2341
Open AccessLate-onset bone granulomatous reaction of hand from immune checkpoint-inhibitors detected on FDG-PET/CT
- Open Access
- 15 May 2024
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 42 (9) , 1038-1046
Effects of percutaneous cryoablation for renal tumor on overall and split renal function
Purpose: To evaluate retrospectively the influence of percutaneous cryoablation for small renal tumors on total and affected kidney function and risk factors associated with worsening function of the affected kidney. Materials and methods: Between April 2016 and March 2022, 27 patients who underwent cryoablation for small renal tumors at our institution participated in this study, which investigated time-dependent changes in postoperative renal function. We evaluated estimated glomerular filtration rates (eGFRs) and split renal function revealed by scintigraphy using 99 m technetium-mercaptoacetyltriglycine (99mTc-MAG3) before cryoablation and at 1 week, 1 month, and 6 months after cryoablation. Numerous variables were analyzed to assess risk factors for worsening renal function. Results: Baseline eGFR (mean ± standard deviation) was 56.5 ± 23.7 mL/min/1.73 m2 (mean ± SD; range, 20.5–112.5). Mean eGFRs at 1 week, 1 month, and 6 months after cryoablation were 57.4 ± 24.5 (19.1–114.9), 57.1 ± 25.1 (21.5–114.9), and 53.8 ± 23.9 mL/min/1.73 m2 (20.0–107.5), respectively. Changes were statistically insignificant (p = 1.0000, = 0.6749, and = 0.0761, respectively). Regarding split renal function, mean baseline contribution of the affected kidney determined by 99mTc-MAG3 was 49.7% ± 6.0% (38.8–63.3%); these rates at 1 week, 1 month, and 6 months after cryoablation were 43.7% ± 8.8 (29.1–70.6%), 46.2% ± 7.7% (32.6–70.3%), and 46.0% ± 8.5% (32.5–67.6%), respectively. Differences from baseline were significant for all periods (p < 0001, < 0001, = 0.0001, respectively). Serum C reactive protein and lactate dehydrogenase at 1 day following cryoablation, tumor’s nearness to the collecting system or sinus, and volume of ablated normal renal parenchyma were significantly correlated with decreased contributions of the affected kidney by > 10% after cryoablation. Conclusion: Unlike total renal function, affected kidney function could worsen after cryoablation.
- 15 May 2024
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 42 (9) , 1038-1046
Open AccessEffects of percutaneous cryoablation for renal tumor on overall and split renal function
Purpose: To evaluate retrospectively the influence of percutaneous cryoablation for small renal tumors on total and affected kidney function and risk factors associated with worsening function of the affected kidney. Materials and methods: Between April 2016 and March 2022, 27 patients who underwent cryoablation for small renal tumors at our institution participated in this study, which investigated time-dependent changes in postoperative renal function. We evaluated estimated glomerular filtration rates (eGFRs) and split renal function revealed by scintigraphy using 99 m technetium-mercaptoacetyltriglycine (99mTc-MAG3) before cryoablation and at 1 week, 1 month, and 6 months after cryoablation. Numerous variables were analyzed to assess risk factors for worsening renal function. Results: Baseline eGFR (mean ± standard deviation) was 56.5 ± 23.7 mL/min/1.73 m2 (mean ± SD; range, 20.5–112.5). Mean eGFRs at 1 week, 1 month, and 6 months after cryoablation were 57.4 ± 24.5 (19.1–114.9), 57.1 ± 25.1 (21.5–114.9), and 53.8 ± 23.9 mL/min/1.73 m2 (20.0–107.5), respectively. Changes were statistically insignificant (p = 1.0000, = 0.6749, and = 0.0761, respectively). Regarding split renal function, mean baseline contribution of the affected kidney determined by 99mTc-MAG3 was 49.7% ± 6.0% (38.8–63.3%); these rates at 1 week, 1 month, and 6 months after cryoablation were 43.7% ± 8.8 (29.1–70.6%), 46.2% ± 7.7% (32.6–70.3%), and 46.0% ± 8.5% (32.5–67.6%), respectively. Differences from baseline were significant for all periods (p < 0001, < 0001, = 0.0001, respectively). Serum C reactive protein and lactate dehydrogenase at 1 day following cryoablation, tumor’s nearness to the collecting system or sinus, and volume of ablated normal renal parenchyma were significantly correlated with decreased contributions of the affected kidney by > 10% after cryoablation. Conclusion: Unlike total renal function, affected kidney function could worsen after cryoablation.
- Open Access
- 2 September 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (11) , 4036-4041
Spontaneous regression of small cell lung cancer associated with Lambert-Eaton Myasthenic Syndrome: Case report
- 2 September 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (11) , 4036-4041
Open AccessSpontaneous regression of small cell lung cancer associated with Lambert-Eaton Myasthenic Syndrome: Case report
- Open Access
- 31 May 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (8) , 2692-2696
A case of pulmonary pleomorphic carcinoma associated with cystic airspace
- 31 May 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (8) , 2692-2696
Open AccessA case of pulmonary pleomorphic carcinoma associated with cystic airspace
- Open Access
- 1 March 2023
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 8 (1) , 18-22
Symptomatic Chronic Severe Stenosis of the Iliac Vein Successfully Treated Endovascularly Using an Interventional Radiology Computed Tomography System
We report a woman with chronic severe stenosis of the left common and external iliac veins and severe post-thrombotic syndrome symptoms. We successfully recanalized the stenotic segment via interventional radiology, which immediately relieved the symptoms. The interventional radiology computed tomography system was helpful for the safe and precise performance of endovascular treatments.
- 1 March 2023
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 8 (1) , 18-22
Open AccessSymptomatic Chronic Severe Stenosis of the Iliac Vein Successfully Treated Endovascularly Using an Interventional Radiology Computed Tomography System
We report a woman with chronic severe stenosis of the left common and external iliac veins and severe post-thrombotic syndrome symptoms. We successfully recanalized the stenotic segment via interventional radiology, which immediately relieved the symptoms. The interventional radiology computed tomography system was helpful for the safe and precise performance of endovascular treatments.
- 21 December 2022
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 32 (1) , 42-45
Removal of central venous port-catheter by the combination of interventional radiological procedures
We encountered a patient with an infection related to an implanted central venous port-catheter that necessitated removal of the system. As the catheter had tightly adhered to the venous wall, removal was impossible with standard methods. After trial and error, we used a guiding catheter that was advanced over the implanted catheter to detach the fibrin sheath on the implanted catheter that had adhered to the vessel wall. At that time, a pull-through technique was used. After we succeeded in detaching the adhesion with the guiding catheter, we were able to withdraw the implanted catheter.
- 21 December 2022
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 32 (1) , 42-45
Removal of central venous port-catheter by the combination of interventional radiological procedures
We encountered a patient with an infection related to an implanted central venous port-catheter that necessitated removal of the system. As the catheter had tightly adhered to the venous wall, removal was impossible with standard methods. After trial and error, we used a guiding catheter that was advanced over the implanted catheter to detach the fibrin sheath on the implanted catheter that had adhered to the vessel wall. At that time, a pull-through technique was used. After we succeeded in detaching the adhesion with the guiding catheter, we were able to withdraw the implanted catheter.
- 15 June 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1136) , 20211159
Dose length product and outcome of CT fluoroscopy-guided interventions using a new 320-detector row CT scanner with deep-learning reconstruction and new bow-tie filter
Objectives: To investigate the dose length product (DLP) and outcomes of CT fluoroscopy (CTF)-guided interventions using a novel 320-detector row CT scanner with deep-learning reconstruction (DLR) and a new bow-tie filter (i.e., Aquilion ONE Prism Edition) and compare with a 320-detector row CT system without DLR and the new bow-tie filter (i.e., Aquilion ONE Vision Edition) (Vision). Methods: CTF-guided interventions performed using Prism and Vision were retrospectively investigated in terms of the technical success rates, clinical success rates of biopsies, complications, DLPs of total CT scans (total DLPs) from February 2019 to January 2021. The total CT scans included pre-interventional CT scans, CTF scans during the CTF-guided procedure, additional CT scans for additional treatment, CTF scans for additional treatment, and post-interventional CT scans. Results: In this study, 87 and 85 CTF-guided interventions were performed using Vision (Vision group) and Prism (Prism group), respectively. There was no significant difference in the technical success rate (96.6% vs 98.8%, p = 0.621), clinical success rate of biopsies (92.9% vs 93.4%, p = 1.000), and minor (8.0% vs 7.1%, p = 0.807) and major (0% vs 3.5%, p = 0.119) complications between the Prism and Vision groups. The total DLPs for the Prism group were significantly lower than those for the Vision group regardless of the procedure (278 vs 548 mGy*cm, p < 0.001, in the biopsy and 246 vs 667 mGy*cm, p < 0.001, in the drainage and aspiration). Conclusions: CTF-guided interventions on Prism reduce the total DLP without performance degradation of the intervention. Advances in knowledge: The total DLPs of biopsies and drainages/aspirations in the Prism group decreased by 49 and 63%, respectively.
- 15 June 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1136) , 20211159
Dose length product and outcome of CT fluoroscopy-guided interventions using a new 320-detector row CT scanner with deep-learning reconstruction and new bow-tie filter
Objectives: To investigate the dose length product (DLP) and outcomes of CT fluoroscopy (CTF)-guided interventions using a novel 320-detector row CT scanner with deep-learning reconstruction (DLR) and a new bow-tie filter (i.e., Aquilion ONE Prism Edition) and compare with a 320-detector row CT system without DLR and the new bow-tie filter (i.e., Aquilion ONE Vision Edition) (Vision). Methods: CTF-guided interventions performed using Prism and Vision were retrospectively investigated in terms of the technical success rates, clinical success rates of biopsies, complications, DLPs of total CT scans (total DLPs) from February 2019 to January 2021. The total CT scans included pre-interventional CT scans, CTF scans during the CTF-guided procedure, additional CT scans for additional treatment, CTF scans for additional treatment, and post-interventional CT scans. Results: In this study, 87 and 85 CTF-guided interventions were performed using Vision (Vision group) and Prism (Prism group), respectively. There was no significant difference in the technical success rate (96.6% vs 98.8%, p = 0.621), clinical success rate of biopsies (92.9% vs 93.4%, p = 1.000), and minor (8.0% vs 7.1%, p = 0.807) and major (0% vs 3.5%, p = 0.119) complications between the Prism and Vision groups. The total DLPs for the Prism group were significantly lower than those for the Vision group regardless of the procedure (278 vs 548 mGy*cm, p < 0.001, in the biopsy and 246 vs 667 mGy*cm, p < 0.001, in the drainage and aspiration). Conclusions: CTF-guided interventions on Prism reduce the total DLP without performance degradation of the intervention. Advances in knowledge: The total DLPs of biopsies and drainages/aspirations in the Prism group decreased by 49 and 63%, respectively.