Donald L. Miller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Donald L. Miller has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Stephen Balter
Department of Medicine, Columbia University Medical Center, New York, New York
6 shared publicationsDavid Haines
4 shared publications- Alexander M. Norbash
Boston University School of Medicine, Boston, Massachusetts
3 shared publications Lynne Fairobent
3 shared publications- Robert G. Dixon
Department of Radiology, University of North Carolina, Chapel Hill, North Carolina
3 shared publications - Eliseo Vano
Complutense University, Madrid, Spain
2 shared publications
Latest Publications
- 30 November 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (11) , 1561-1562
Society of Interventional Radiology Position Statement: Prevention of Unintentionally Retained Foreign Bodies during Interventional Radiology Procedures
- 30 November 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (11) , 1561-1562
Society of Interventional Radiology Position Statement: Prevention of Unintentionally Retained Foreign Bodies during Interventional Radiology Procedures
- 31 October 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (10) , 1353-1354
Position Statement by the Society of Interventional Radiology: Maintenance of Privileges for Image-guided Interventions
- 31 October 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (10) , 1353-1354
Position Statement by the Society of Interventional Radiology: Maintenance of Privileges for Image-guided Interventions
- 30 April 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (4) , 425-429
Optimizing Radiation Use during Fluoroscopic Procedures: Proceedings from a Multidisciplinary Consensus Panel
- 30 April 2011
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 22 (4) , 425-429
Optimizing Radiation Use during Fluoroscopic Procedures: Proceedings from a Multidisciplinary Consensus Panel
- 28 February 2011
- Published by Wiley in Medical Physics
- Vol. 38 (3) , 1611-1618
Patient radiation dose audits for fluoroscopically guided interventional procedures
Purpose: Quality management for any use of medical x‐ray imaging should include monitoring of radiation dose. Fluoroscopically guided interventional (FGI) procedures are inherently clinically variable and have the potential for inducing deterministic injuries in patients. The use of a conventional diagnostic reference level is not appropriate for FGI procedures. A similar but more detailed quality process for management of radiation dose in FGI procedures is described.Methods: A method that takes into account both the inherent variability of FGI procedures and the risk of deterministic injuries from these procedures is suggested. The substantial radiation dose level (SRDL) is an absolute action level (with regard to patient follow‐up) below which skin injury is highly unlikely and above which skin injury is possible. The quality process for FGI procedures collects data from all instances of a given procedure from a number of facilities into an advisory data set (ADS). An individual facility collects a facility data set (FDS) comprised of all instances of the same procedure at that facility. The individual FDS is then compared to the multifacility ADS with regard to the overall shape of the dose distributions and the percent of instances in both the ADS and the FDS that exceed the SRDL.Results: Samples of an ADS and FDS for percutaneous coronary intervention, using the dose metric of reference air kerma (i.e., the cumulative air kerma at the reference point), are used to illustrate the proposed quality process for FGI procedures. Investigation is warranted whenever the FDS is noticeably different from the ADS for the specific FGI procedure and particularly in two circumstances: (1) When the facility's local median exceeds the 75th percentile of the ADS and (2) when the percent of instances where exceeds the facility‐selected SRDL is greater for the FDS than for the ADS.Conclusions: Analysis of the two data sets (ADS and FDS) and of the percent of instances that exceed the SRDL provides a means for the facility to better manage radiation dose (and therefore both deterministic and stochastic radiation risk) to the patient during FGI procedures.
- 28 February 2011
- Published by Wiley in Medical Physics
- Vol. 38 (3) , 1611-1618
Patient radiation dose audits for fluoroscopically guided interventional procedures
Purpose: Quality management for any use of medical x‐ray imaging should include monitoring of radiation dose. Fluoroscopically guided interventional (FGI) procedures are inherently clinically variable and have the potential for inducing deterministic injuries in patients. The use of a conventional diagnostic reference level is not appropriate for FGI procedures. A similar but more detailed quality process for management of radiation dose in FGI procedures is described.Methods: A method that takes into account both the inherent variability of FGI procedures and the risk of deterministic injuries from these procedures is suggested. The substantial radiation dose level (SRDL) is an absolute action level (with regard to patient follow‐up) below which skin injury is highly unlikely and above which skin injury is possible. The quality process for FGI procedures collects data from all instances of a given procedure from a number of facilities into an advisory data set (ADS). An individual facility collects a facility data set (FDS) comprised of all instances of the same procedure at that facility. The individual FDS is then compared to the multifacility ADS with regard to the overall shape of the dose distributions and the percent of instances in both the ADS and the FDS that exceed the SRDL.Results: Samples of an ADS and FDS for percutaneous coronary intervention, using the dose metric of reference air kerma (i.e., the cumulative air kerma at the reference point), are used to illustrate the proposed quality process for FGI procedures. Investigation is warranted whenever the FDS is noticeably different from the ADS for the specific FGI procedure and particularly in two circumstances: (1) When the facility's local median exceeds the 75th percentile of the ADS and (2) when the percent of instances where exceeds the facility‐selected SRDL is greater for the FDS than for the ADS.Conclusions: Analysis of the two data sets (ADS and FDS) and of the percent of instances that exceed the SRDL provides a means for the facility to better manage radiation dose (and therefore both deterministic and stochastic radiation risk) to the patient during FGI procedures.
- 1 November 2010
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 257 (2) , 321-332
Clinical Radiation Management for Fluoroscopically Guided Interventional Procedures
The primary goal of radiation management in interventional radiology is to minimize the unnecessary use of radiation. Clinical radiation management minimizes radiation risk to the patient without increasing other risks, such as procedural risks. A number of factors are considered when estimating the likelihood and severity of patient radiation effects. These include demographic factors, medical history factors, and procedure factors. Important aspects of the patient's medical history include coexisting diseases and genetic factors, medication use, radiation history, and pregnancy. As appropriate, these are evaluated as part of the preprocedure patient evaluation; radiation risk to the patient is considered along with other procedural risks. Dose optimization is possible through appropriate use of the basic features of interventional fluoroscopic equipment and intelligent use of dose-reducing technology. For all fluoroscopically guided interventional procedures, it is good practice to monitor radiation dose throughout the procedure and record it in the patient's medical record. Patients who have received a clinically significant radiation dose should be followed up after the procedure for possible deterministic effects. The authors recommend including radiation management as part of the departmental quality assurance program.
- 1 November 2010
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 257 (2) , 321-332
Clinical Radiation Management for Fluoroscopically Guided Interventional Procedures
The primary goal of radiation management in interventional radiology is to minimize the unnecessary use of radiation. Clinical radiation management minimizes radiation risk to the patient without increasing other risks, such as procedural risks. A number of factors are considered when estimating the likelihood and severity of patient radiation effects. These include demographic factors, medical history factors, and procedure factors. Important aspects of the patient's medical history include coexisting diseases and genetic factors, medication use, radiation history, and pregnancy. As appropriate, these are evaluated as part of the preprocedure patient evaluation; radiation risk to the patient is considered along with other procedural risks. Dose optimization is possible through appropriate use of the basic features of interventional fluoroscopic equipment and intelligent use of dose-reducing technology. For all fluoroscopically guided interventional procedures, it is good practice to monitor radiation dose throughout the procedure and record it in the patient's medical record. Patients who have received a clinically significant radiation dose should be followed up after the procedure for possible deterministic effects. The authors recommend including radiation management as part of the departmental quality assurance program.
- 1 September 2010
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 7 (9) , 679-683
Special Communication— Occupational Health Hazards in the Interventional Laboratory: Progress Report of the Multispecialty Occupational Health Group
- 1 September 2010
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 7 (9) , 679-683
Special Communication— Occupational Health Hazards in the Interventional Laboratory: Progress Report of the Multispecialty Occupational Health Group
- 1 September 2010
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 21 (9) , 1338-1341
Occupational Health Hazards in the Interventional Laboratory: Progress Report of the Multispecialty Occupational Health Group
- 1 September 2010
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 21 (9) , 1338-1341
Occupational Health Hazards in the Interventional Laboratory: Progress Report of the Multispecialty Occupational Health Group
- 26 August 2010
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 2 (3) , 245-248
Occupational health hazards in the interventional laboratory: progress report of the Multispecialty Occupational Health Group
The Multispecialty Occupational Health Group (MSOHG), formed in 2005, is an informal coalition of societies representing professionals who work in or are concerned with interventional fluoroscopy. The group's long term goals are to improve occupational health and operator and staff safety in the interventional laboratory while maintaining quality patient care and optimal use of the laboratory. MSOHG has conducted a dialog with equipment manufacturers and has developed a list of specific objectives for research and development. The group has also represented the member societies in educating regulators, in educating interventionalists and in fostering and collaborating on research into occupational health issues affecting interventionalists. Not least of the group's accomplishments, as a result of their collaboration in MSOHG, the group's members have developed a mutual respect that can serve as a basis for joint efforts in the future among interventionalists of different medical specialties.
- 26 August 2010
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 2 (3) , 245-248
Occupational health hazards in the interventional laboratory: progress report of the Multispecialty Occupational Health Group
The Multispecialty Occupational Health Group (MSOHG), formed in 2005, is an informal coalition of societies representing professionals who work in or are concerned with interventional fluoroscopy. The group's long term goals are to improve occupational health and operator and staff safety in the interventional laboratory while maintaining quality patient care and optimal use of the laboratory. MSOHG has conducted a dialog with equipment manufacturers and has developed a list of specific objectives for research and development. The group has also represented the member societies in educating regulators, in educating interventionalists and in fostering and collaborating on research into occupational health issues affecting interventionalists. Not least of the group's accomplishments, as a result of their collaboration in MSOHG, the group's members have developed a mutual respect that can serve as a basis for joint efforts in the future among interventionalists of different medical specialties.
- Open Access
- 18 December 2009
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 33 (2) , 230-239
Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology
- 18 December 2009
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 33 (2) , 230-239
Open AccessOccupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology