Wayne L. Monsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Wayne L. Monsky has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Armando S. Garza
University of California Davis Medical School, Sacramento, USA
2 shared publicationsChin-Shang Li
Department of Public Health Sciences, Division of Biostatistics, University of California, UC Davis Medical Center, Sacramento, CA
2 shared publicationsIsaac Kim
University of California, UC Davis Medical Center, School of Medicine, Sacramento, CA
2 shared publicationsLarry-Stuart Deutsch
Department of Radiology, University of California, UC Davis Medical Center, 4820 Y St., Sacramento, CA 95817
2 shared publicationsRamsey D. Badawi
Department of Radiology, University of California, UC Davis Medical Center, 4820 Y St., Sacramento, CA 95817
2 shared publicationsShaun Loh
Department of Radiology, University of California, UC Davis Medical Center, 4820 Y St., Sacramento, CA 95817
2 shared publications
Latest Publications
- 1 September 2011
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 31 (5) , 1449-1462
Nanotechnology Development and Utilization: A Primer for Diagnostic and Interventional Radiologists
The term nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Much of the ongoing research and development of nanotechnology is focused on the development of novel methods of imaging and delivery of therapeutics through minimally invasive means. Multifunctional nanoparticles offer great promise for molecular imaging and directing novel therapeutics to molecular targets, which was never before possible. Nanoparticle-based contrast agents have been developed for all imaging modalities. A rapidly increasing number of companies and government funding initiatives have led to a large number of novel agents in various stages of development, ranging from in vitro and in vivo animal studies to clinical use. However, barriers to the delivery of nanoparticles for tumor imaging and therapy exist. Interventional radiologists may circumvent these barriers by using imaging to guide delivery of nanoparticles.
- 1 September 2011
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 31 (5) , 1449-1462
Nanotechnology Development and Utilization: A Primer for Diagnostic and Interventional Radiologists
The term nanotechnology refers to the design, creation, and manipulation of structures on the nanometer scale. Much of the ongoing research and development of nanotechnology is focused on the development of novel methods of imaging and delivery of therapeutics through minimally invasive means. Multifunctional nanoparticles offer great promise for molecular imaging and directing novel therapeutics to molecular targets, which was never before possible. Nanoparticle-based contrast agents have been developed for all imaging modalities. A rapidly increasing number of companies and government funding initiatives have led to a large number of novel agents in various stages of development, ranging from in vitro and in vivo animal studies to clinical use. However, barriers to the delivery of nanoparticles for tumor imaging and therapy exist. Interventional radiologists may circumvent these barriers by using imaging to guide delivery of nanoparticles.
- Open Access
- 12 November 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (2) , 383-390
A Novel Mechanical Thrombectomy Device for Retrieval of Intravascular Thrombus
Purpose Thrombotic and embolic vascular occlusion represents a leading cause of morbidity and mortality. Currently available thrombectomy devices have limitations, including difficulty removing organized thrombus and clot fragmentation with distal embolization. A novel mechanical thrombectomy device (MTD), designed to remove both hard and soft thrombus without trauma to the blood vessel, was tested in preclinical porcine models evaluating efficacy, safety, and ease of use. Materials and Methods A total of 26 vessels in 14 pigs underwent mechanical thrombectomy with MTD. Thrombectomy was performed in nine superficial femoral arteries, eight subclavian arteries, five primary branches of the subclavian artery, lateral thoracic artery or the thyrocervical trunk, and four external carotids. Subacute organized fibrin-laden thrombus was injected into the arteries producing vascular occlusion. The MTD was then used for thrombectomy to restore patency and blood flow. Results Intact thrombus was retrieved from 24 of 26 of the vessels with a single pass of the MTD, resulting in complete restoration of patency in 21 vessels and partial patency in 4 vessels. In 8 cases that used an early design, the embolic material fragmented during withdrawal from the access sheath. In 4 procedures that used an early design, the MTD failed to deploy fully and the embolus was not completely captured. No intraprocedural complications or vascular damage occurred. Conclusions The present pilot studies demonstrate basic safety and efficacy of a novel MTD with design attributes suitable for retrieval of intact acute and organized chronic thrombus. The device has potential intracranial and peripheral utility.
- 12 November 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (2) , 383-390
Open AccessA Novel Mechanical Thrombectomy Device for Retrieval of Intravascular Thrombus
Purpose Thrombotic and embolic vascular occlusion represents a leading cause of morbidity and mortality. Currently available thrombectomy devices have limitations, including difficulty removing organized thrombus and clot fragmentation with distal embolization. A novel mechanical thrombectomy device (MTD), designed to remove both hard and soft thrombus without trauma to the blood vessel, was tested in preclinical porcine models evaluating efficacy, safety, and ease of use. Materials and Methods A total of 26 vessels in 14 pigs underwent mechanical thrombectomy with MTD. Thrombectomy was performed in nine superficial femoral arteries, eight subclavian arteries, five primary branches of the subclavian artery, lateral thoracic artery or the thyrocervical trunk, and four external carotids. Subacute organized fibrin-laden thrombus was injected into the arteries producing vascular occlusion. The MTD was then used for thrombectomy to restore patency and blood flow. Results Intact thrombus was retrieved from 24 of 26 of the vessels with a single pass of the MTD, resulting in complete restoration of patency in 21 vessels and partial patency in 4 vessels. In 8 cases that used an early design, the embolic material fragmented during withdrawal from the access sheath. In 4 procedures that used an early design, the MTD failed to deploy fully and the embolus was not completely captured. No intraprocedural complications or vascular damage occurred. Conclusions The present pilot studies demonstrate basic safety and efficacy of a novel MTD with design attributes suitable for retrieval of intact acute and organized chronic thrombus. The device has potential intracranial and peripheral utility.
- 1 November 2010
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 195 (5) , 1220-1230
Semiautomated Segmentation for Volumetric Analysis of Intratumoral Ethiodol Uptake and Subsequent Tumor Necrosis After Chemoembolization
OBJECTIVE. Linear measurements, such as those described by the Response Evaluation Criteria in Solid Tumors (RECIST) criteria, may be limited for assessment of response after transarterial chemoembolization (TACE). The purpose of this pilot study was to show intra- and interobserver reproducibility of volumetric measurements of Ethiodol (ethiodized oil) seen within tumor 24 hours after TACE and of necrotic and viable tumor 1 month after treatment. Volumetric measurements are compared with linear measurements and survival outcomes.MATERIALS AND METHODS. Between 2006 and 2009, 37 consecutive TACE procedures were performed in 27 patients with hepatic malignancies. CT images obtained 24 hours and 1 month after TACE were retrospectively analyzed. Three observers measured volumes twice. Intraoperator reproducibility was determined using Wilcoxon's signed rank test to assess whether the difference in each volumetric measurement approaches zero. The intraclass correlation coefficient (ICC) and Bland-Altman plots ...
- 1 November 2010
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 195 (5) , 1220-1230
Semiautomated Segmentation for Volumetric Analysis of Intratumoral Ethiodol Uptake and Subsequent Tumor Necrosis After Chemoembolization
OBJECTIVE. Linear measurements, such as those described by the Response Evaluation Criteria in Solid Tumors (RECIST) criteria, may be limited for assessment of response after transarterial chemoembolization (TACE). The purpose of this pilot study was to show intra- and interobserver reproducibility of volumetric measurements of Ethiodol (ethiodized oil) seen within tumor 24 hours after TACE and of necrotic and viable tumor 1 month after treatment. Volumetric measurements are compared with linear measurements and survival outcomes.MATERIALS AND METHODS. Between 2006 and 2009, 37 consecutive TACE procedures were performed in 27 patients with hepatic malignancies. CT images obtained 24 hours and 1 month after TACE were retrospectively analyzed. Three observers measured volumes twice. Intraoperator reproducibility was determined using Wilcoxon's signed rank test to assess whether the difference in each volumetric measurement approaches zero. The intraclass correlation coefficient (ICC) and Bland-Altman plots ...
- Open Access
- 4 August 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (2) , 306-318
Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy
Purpose The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. Methods Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Three observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. Results Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan–Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). Conclusion Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival.
- 4 August 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (2) , 306-318
Open AccessTreatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy
Purpose The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. Methods Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Three observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. Results Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan–Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). Conclusion Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival.
- 30 September 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (9) , 1231-1234
Congenital Single, Pelvic Iliac Artery: A Case Report
- 30 September 2009
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 20 (9) , 1231-1234
Congenital Single, Pelvic Iliac Artery: A Case Report