Jan Menke
Jan Menke has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Inga-Marie Schaefer
Department of Pathology, Brigham and Women’s Hospital, Harvard Medical School, Boston, USA
4 shared publications Jörg Larsen
Department of Clinical Radiology, Protestant Hospital, Goettingen, Germany
4 shared publicationsAlexander Schwarz
Department of Diagnostic Radiology, University Hospital, Goettingen, Germany
2 shared publicationsAndras Kertesz
Department of Diagnostic Radiology, University Hospital, Robert‐Koch‐Strasse 40, 37075 Goettingen, Germany
2 shared publicationsChristina Unterberg-Buchwald
2 shared publicationsGerhard Möller
University Hospital Goettingen
2 shared publications
Latest Publications
- 20 May 2015
- Published by Springer Nature in European Radiology
- Vol. 26 (2) , 451-458
Diagnostic accuracy and utility of coronary CT angiography with consideration of unevaluable results: A systematic review and multivariate Bayesian random-effects meta-analysis with intention to diagnose
To meta-analyze diagnostic accuracy, test yield and utility of coronary computed tomography angiography (CCTA) in coronary artery disease (CAD) by an intention-to-diagnose approach with inclusion of unevaluable results. Four databases were searched from 1/2005 to 3/2013 for prospective studies that used 16–320-row or dual-source CTs and provided 3 × 2 patient-level data of CCTA (positive, negative, or unevaluable) versus catheter angiography (positive or negative) for diagnosing ≥50 % coronary stenoses. A Bayesian multivariate 3 × 2 random-effects meta-analysis considered unevaluable CCTAs. Thirty studies (3422 patients) were included. Compared to 16–40 row CT, test yield and accuracy of CCTA has significantly increased with ≥64-row CT (P < 0.05). In ≥64-row CT, about 2.5 % (95 %-CI, 0.9–4.8 %) of diseased patients and 7.5 % (4.5–11.2 %) of non-diseased patients had unevaluable CCTAs. A positive likelihood ratio of 8.9 (6.1–13.5) indicated moderate suitability for identifying CAD. A negative likelihood ratio of 0.022 (0.01–0.04) indicated excellent suitability for excluding CAD. Unevaluable CCTAs had an equivocal likelihood ratio of 0.42 (0.22–0.71). In the utility analysis, CCTA was useful at intermediate pre-test probabilities (16–70 %). CCTA is useful at intermediate CAD pre-test probabilities. Positive CCTAs require verification to confirm CAD, unevaluable CCTAs require alternative diagnostics, and negative CCTAs exclude obstructive CAD with high certainty. • This 3 × 2 Bayesian meta-analysis included unevaluable CCTAs with intention-to-diagnose. • CCTA is currently useful at intermediate CAD pre-test probabilities. • Unevaluable CCTAs should not, generally, be treated as if they are positive. • Positive CCTAs require verification by other methods to confirm CAD. • Negative CCTAs exclude CAD with high certainty.
- 20 May 2015
- Published by Springer Nature in European Radiology
- Vol. 26 (2) , 451-458
Diagnostic accuracy and utility of coronary CT angiography with consideration of unevaluable results: A systematic review and multivariate Bayesian random-effects meta-analysis with intention to diagnose
To meta-analyze diagnostic accuracy, test yield and utility of coronary computed tomography angiography (CCTA) in coronary artery disease (CAD) by an intention-to-diagnose approach with inclusion of unevaluable results. Four databases were searched from 1/2005 to 3/2013 for prospective studies that used 16–320-row or dual-source CTs and provided 3 × 2 patient-level data of CCTA (positive, negative, or unevaluable) versus catheter angiography (positive or negative) for diagnosing ≥50 % coronary stenoses. A Bayesian multivariate 3 × 2 random-effects meta-analysis considered unevaluable CCTAs. Thirty studies (3422 patients) were included. Compared to 16–40 row CT, test yield and accuracy of CCTA has significantly increased with ≥64-row CT (P < 0.05). In ≥64-row CT, about 2.5 % (95 %-CI, 0.9–4.8 %) of diseased patients and 7.5 % (4.5–11.2 %) of non-diseased patients had unevaluable CCTAs. A positive likelihood ratio of 8.9 (6.1–13.5) indicated moderate suitability for identifying CAD. A negative likelihood ratio of 0.022 (0.01–0.04) indicated excellent suitability for excluding CAD. Unevaluable CCTAs had an equivocal likelihood ratio of 0.42 (0.22–0.71). In the utility analysis, CCTA was useful at intermediate pre-test probabilities (16–70 %). CCTA is useful at intermediate CAD pre-test probabilities. Positive CCTAs require verification to confirm CAD, unevaluable CCTAs require alternative diagnostics, and negative CCTAs exclude obstructive CAD with high certainty. • This 3 × 2 Bayesian meta-analysis included unevaluable CCTAs with intention-to-diagnose. • CCTA is currently useful at intermediate CAD pre-test probabilities. • Unevaluable CCTAs should not, generally, be treated as if they are positive. • Positive CCTAs require verification by other methods to confirm CAD. • Negative CCTAs exclude CAD with high certainty.
- 1 May 2015
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 33 (13) , e62-e65
Uniparental Trisomy of a Mutated HRAS Proto-Oncogene in Embryonal Rhabdomyosarcoma of a Patient With Costello Syndrome
- 1 May 2015
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 33 (13) , e62-e65
Uniparental Trisomy of a Mutated HRAS Proto-Oncogene in Embryonal Rhabdomyosarcoma of a Patient With Costello Syndrome
- Open Access
- 12 March 2015
- Published by BMJ in BMJ Case Reports
- Vol. 2015
Cardiovascular MR angiography in partial anomalous pulmonary venous connection
Ten years later the patient opted for further diagnostics since she now had exercise-induced dyspnoea. A temporally resolved contrast-enhanced cardiovascular MR angiography was performed. According to phase contrast imaging, the pulmonary-to-systemic flow ratio was elevated to 1.4-to-1, indicating left-to-right shunting. On the right side several small lung veins drained into an abnormal vertical vein (figure 1A, arrows) with anomalous venous return into the inferior vena cava (figure 1A, B, *). Two right pulmonary veins drained independently into the left atrium, whereas two other tortuous right pulmonary veins extended from the left atrium to the vertical vein (figure 1B, arrowheads; online supplementary figure S2; video 1). Effectively, this represented dual drainage from the vertical vein into the inferior vena cava and into the left atrium. This vascular anatomy allowed for interventional occlusion of the distal vertical vein by an Amplatzer vascular plug (figure 1C, arrowhead)1 by paediatric cardiologists after a balloon occlusion test had been successful. Subsequently, the patient was well and without dyspnoea.
- 12 March 2015
- Published by BMJ in BMJ Case Reports
- Vol. 2015
Open AccessCardiovascular MR angiography in partial anomalous pulmonary venous connection
Ten years later the patient opted for further diagnostics since she now had exercise-induced dyspnoea. A temporally resolved contrast-enhanced cardiovascular MR angiography was performed. According to phase contrast imaging, the pulmonary-to-systemic flow ratio was elevated to 1.4-to-1, indicating left-to-right shunting. On the right side several small lung veins drained into an abnormal vertical vein (figure 1A, arrows) with anomalous venous return into the inferior vena cava (figure 1A, B, *). Two right pulmonary veins drained independently into the left atrium, whereas two other tortuous right pulmonary veins extended from the left atrium to the vertical vein (figure 1B, arrowheads; online supplementary figure S2; video 1). Effectively, this represented dual drainage from the vertical vein into the inferior vena cava and into the left atrium. This vascular anatomy allowed for interventional occlusion of the distal vertical vein by an Amplatzer vascular plug (figure 1C, arrowhead)1 by paediatric cardiologists after a balloon occlusion test had been successful. Subsequently, the patient was well and without dyspnoea.
- Open Access
- 3 March 2015
- Published by BMJ in BMJ Case Reports
- Vol. 2015
Cardiac CT in an aberrant right coronary artery
- 3 March 2015
- Published by BMJ in BMJ Case Reports
- Vol. 2015
Open AccessCardiac CT in an aberrant right coronary artery
- 27 February 2015
- Published by Springer Nature in European Radiology
- Vol. 25 (8) , 2205-2213
Photoacoustic breast tomography prototypes with reported human applications
Photoacoustic breast tomography could provide optical molecular imaging with near-infrared light at sonographic image resolution by utilizing the photoacoustic effect. This review summarizes reports about current prototypes that were applied in vivo in humans. Four databases were searched for reports about prototypes of photoacoustic breast tomography that were tested in vivo in humans. Data extracted from the reports comprised details about system design, phantom studies, and clinical studies. Five prototypes were included. System designs comprised planar, hemicylindrical and hemispherical geometries. In total, 52 of 61 breast cancers (85 %) were detected by three of the prototypes, showing image details such as ring-pattern of the haemoglobin-rich tumour vasculature. A refined prototype provided submillimetre resolution at a good contrast-to-noise ratio up to a depth of about 5 cm in a cup-shaped breast configuration. Another novel prototype demonstrated that in the mammographic imaging geometry, the total imaging depth approximately duplicates with bilateral laser illumination. Most prototypes focused on detecting elevated haemoglobin content related to tumours, but proof-of-principle was also given for multispectral optoacoustic tomography by additional imaging of tissue oxygenation. Photoacoustic breast tomography can detect breast cancer. This radiation-free molecular imaging technology should be further refined and studied for clinical applications. • Photoacoustics combines optical imaging with sonographic signal detection. • Photoacoustic tomography could provide molecular imaging at high image resolution. • Prototypes have been designed for human breast cancer imaging. • Preliminary evaluation studies show that photoacoustic tomography detects breast cancer. • This radiation-free method should be further improved and studied for clinical applications.
- 27 February 2015
- Published by Springer Nature in European Radiology
- Vol. 25 (8) , 2205-2213
Photoacoustic breast tomography prototypes with reported human applications
Photoacoustic breast tomography could provide optical molecular imaging with near-infrared light at sonographic image resolution by utilizing the photoacoustic effect. This review summarizes reports about current prototypes that were applied in vivo in humans. Four databases were searched for reports about prototypes of photoacoustic breast tomography that were tested in vivo in humans. Data extracted from the reports comprised details about system design, phantom studies, and clinical studies. Five prototypes were included. System designs comprised planar, hemicylindrical and hemispherical geometries. In total, 52 of 61 breast cancers (85 %) were detected by three of the prototypes, showing image details such as ring-pattern of the haemoglobin-rich tumour vasculature. A refined prototype provided submillimetre resolution at a good contrast-to-noise ratio up to a depth of about 5 cm in a cup-shaped breast configuration. Another novel prototype demonstrated that in the mammographic imaging geometry, the total imaging depth approximately duplicates with bilateral laser illumination. Most prototypes focused on detecting elevated haemoglobin content related to tumours, but proof-of-principle was also given for multispectral optoacoustic tomography by additional imaging of tissue oxygenation. Photoacoustic breast tomography can detect breast cancer. This radiation-free molecular imaging technology should be further refined and studied for clinical applications. • Photoacoustics combines optical imaging with sonographic signal detection. • Photoacoustic tomography could provide molecular imaging at high image resolution. • Prototypes have been designed for human breast cancer imaging. • Preliminary evaluation studies show that photoacoustic tomography detects breast cancer. • This radiation-free method should be further improved and studied for clinical applications.
- Open Access
- 25 February 2015
- Published by BMJ in BMJ Case Reports
- Vol. 2015
Multimodal cardiac imaging of a postinfarction subvalvular left ventricular aneurysm
- 25 February 2015
- Published by BMJ in BMJ Case Reports
- Vol. 2015
Open AccessMultimodal cardiac imaging of a postinfarction subvalvular left ventricular aneurysm
- 1 January 2015
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 13 (5) , 051701-51705
Fluorochrome-labeled monoclonal antibody with characteristic M-shaped spectral peak for optical imaging: Dual-labeling versus mixture of fluorochromes
In this work two different fluorochromes (Alexa 594 and Alexa 680) are conjugated to the same monoclonal antibody (Cetuximab) for obtaining a characteristic M-shaped dual-peak spectrum. Dual-labeling of Cetuximab by mixing both fluorochromes before the conjugation step gives spectral results similar to those of mixing of fluorochrome-labeled Cetuximab after the conjugation step (P>0.05). In conclusion, both methods may be used equivalently for producing a dual-labeled single-antibody probe. Future studies may test whether the M-shaped spectrum may increase the diagnostic confidence in tumor-targeted multispectral optical imaging.
- 1 January 2015
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 13 (5) , 051701-51705
Fluorochrome-labeled monoclonal antibody with characteristic M-shaped spectral peak for optical imaging: Dual-labeling versus mixture of fluorochromes
In this work two different fluorochromes (Alexa 594 and Alexa 680) are conjugated to the same monoclonal antibody (Cetuximab) for obtaining a characteristic M-shaped dual-peak spectrum. Dual-labeling of Cetuximab by mixing both fluorochromes before the conjugation step gives spectral results similar to those of mixing of fluorochrome-labeled Cetuximab after the conjugation step (P>0.05). In conclusion, both methods may be used equivalently for producing a dual-labeled single-antibody probe. Future studies may test whether the M-shaped spectrum may increase the diagnostic confidence in tumor-targeted multispectral optical imaging.
- 19 August 2014
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 174 (3) , 307-316
Sonography-guided hydrostatic reduction of ileocolic intussusception in children: Analysis of failure and success in consecutive patients presenting timely to the hospital
In children with ileocolic intussusception sonography is increasingly being used for diagnosis, whereas fluoroscopy is frequently used for guiding non-invasive reduction. This study assessed the success rate of radiation-free sonography-guided hydrostatic reduction in children with ileocolic intussusception, using novel well-defined success rate indices. All children were evaluated who presented from 2005 to 2013 to the local university hospital with ileocolic intussusception. The patients were treated with sonography-guided hydrostatic reduction unless primary surgery was clinically indicated. The according success rate was determined by indices of Bekdash et al. They represent the ratio of persistently successful non-surgical reductions versus four different denominators, depending on including/excluding cases with primary surgery and including/excluding cases requiring bowel resection/intervention. Fifty-six consecutive patients were included (age, 3 months to 7.8 years). About 80 % of the patients presented until 24 h and 20 % until 48 h after the onset of symptoms. Seven patients underwent primary surgery, with bowel resection required in three cases. Hydrostatic reduction was attempted in 49 patients, being permanently successful in 41 cases (selective reduction rate 41/49 = 83.7 %; crude reduction rate 41/56 = 73.2 %). The remaining eight patients underwent secondary surgery, with just two patients not requiring surgical bowel resection/intervention (corrected selective reduction rate 41/43 = 95.3 %). The composite reduction rate was 87.2 % (successful/feasible reductions, 41/47). Conclusion: Radiation-free sonography-guided hydrostatic reduction has a good success rate in children with ileocolic intussusception. It may be particularly valuable in centers that are already experienced with using sonography for the diagnosis.
- 19 August 2014
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 174 (3) , 307-316
Sonography-guided hydrostatic reduction of ileocolic intussusception in children: Analysis of failure and success in consecutive patients presenting timely to the hospital
In children with ileocolic intussusception sonography is increasingly being used for diagnosis, whereas fluoroscopy is frequently used for guiding non-invasive reduction. This study assessed the success rate of radiation-free sonography-guided hydrostatic reduction in children with ileocolic intussusception, using novel well-defined success rate indices. All children were evaluated who presented from 2005 to 2013 to the local university hospital with ileocolic intussusception. The patients were treated with sonography-guided hydrostatic reduction unless primary surgery was clinically indicated. The according success rate was determined by indices of Bekdash et al. They represent the ratio of persistently successful non-surgical reductions versus four different denominators, depending on including/excluding cases with primary surgery and including/excluding cases requiring bowel resection/intervention. Fifty-six consecutive patients were included (age, 3 months to 7.8 years). About 80 % of the patients presented until 24 h and 20 % until 48 h after the onset of symptoms. Seven patients underwent primary surgery, with bowel resection required in three cases. Hydrostatic reduction was attempted in 49 patients, being permanently successful in 41 cases (selective reduction rate 41/49 = 83.7 %; crude reduction rate 41/56 = 73.2 %). The remaining eight patients underwent secondary surgery, with just two patients not requiring surgical bowel resection/intervention (corrected selective reduction rate 41/43 = 95.3 %). The composite reduction rate was 87.2 % (successful/feasible reductions, 41/47). Conclusion: Radiation-free sonography-guided hydrostatic reduction has a good success rate in children with ileocolic intussusception. It may be particularly valuable in centers that are already experienced with using sonography for the diagnosis.
- Open Access
- 10 June 2014
- Published by Springer Nature in Pediatric Cardiology
- Vol. 35 (6) , 1082
Erratum to: Cerebral Near-Infrared Spectroscopy Correlates to Vital Parameters During Cardiopulmonary Bypass Surgery in Children
- 10 June 2014
- Published by Springer Nature in Pediatric Cardiology
- Vol. 35 (6) , 1082
Open AccessErratum to: Cerebral Near-Infrared Spectroscopy Correlates to Vital Parameters During Cardiopulmonary Bypass Surgery in Children
- Open Access
- 6 January 2014
- Published by BMJ in BMJ Case Reports
- Vol. 2014
Selective coil embolisation in spontaneous perirenal haemorrhage
A 71-year-old woman presented to the emergency department with abdominal pain and fever. Her surgical history was significant for gallbladder adenocarcinoma for which she had undergone extensive resection 32 months previously. At that time she underwent cholecystectomy, wedge resection of the liver, pancreatoduodenectomy, right nephrectomy and right hemicolectomy for a locally advanced gallbladder adenocarcinoma. Examination revealed a tender, warm, upper midline abdominal wall mass. A CT scan with oral contrast revealed a fistulous tract extending from the gastrojejunostomy (GJ) into an abscess cavity in the adjacent anterior abdominal wall. She underwent open wound drainage with debridement, and was started on parenteral nutrition and intravenous antibiotics. The patient then underwent surgical repair excision of the fistula and refashioning of the GJ 1 month later. Histological examination of the specimen revealed well-healed suture lines, and no evidence of tumour recurrence.
- 6 January 2014
- Published by BMJ in BMJ Case Reports
- Vol. 2014
Open AccessSelective coil embolisation in spontaneous perirenal haemorrhage
A 71-year-old woman presented to the emergency department with abdominal pain and fever. Her surgical history was significant for gallbladder adenocarcinoma for which she had undergone extensive resection 32 months previously. At that time she underwent cholecystectomy, wedge resection of the liver, pancreatoduodenectomy, right nephrectomy and right hemicolectomy for a locally advanced gallbladder adenocarcinoma. Examination revealed a tender, warm, upper midline abdominal wall mass. A CT scan with oral contrast revealed a fistulous tract extending from the gastrojejunostomy (GJ) into an abscess cavity in the adjacent anterior abdominal wall. She underwent open wound drainage with debridement, and was started on parenteral nutrition and intravenous antibiotics. The patient then underwent surgical repair excision of the fistula and refashioning of the GJ 1 month later. Histological examination of the specimen revealed well-healed suture lines, and no evidence of tumour recurrence.