RWRianne Wittenberg

Rianne Wittenberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rianne Wittenberg has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Cornelia M. Schaefer-Prokop

    Department of Radiology, Academic Medical Centre, Amsterdam, the Netherlands

    1 shared publication
  • Jeroen J. Sonnemans

    Healthcare Informatics – Clinical Science & Advanced Development, Philips Healthcare, Best, The Netherlands

    1 shared publication
  • Joost F. Peters

    Healthcare Informatics – Clinical Science & Advanced Development, Philips Healthcare, Best, The Netherlands

    1 shared publication
  • Mathias Prokop

    Diagnostic Image Analysis Group, Radboud University Medical Center, Nijmegen, The Netherlands

    1 shared publication

Latest Publications

  • Open Access

    Computer-assisted detection of pulmonary embolism: evaluation of pulmonary CT angiograms performed in an on-call setting

    by Rianne Wittenberg, Joost F. Peters, Jeroen J. Sonnemans, Mathias Prokop, Cornelia M. Schaefer-Prokop

    Purpose The purpose of the study was to assess the stand-alone performance of computer-assisted detection (CAD) for evaluation of pulmonary CT angiograms (CTPA) performed in an on-call setting. Methods In this institutional review board-approved study, we retrospectively included 292 consecutive CTPA performed during night shifts and weekends over a period of 16 months. Original reports were compared with a dedicated CAD system for pulmonary emboli (PE). A reference standard for the presence of PE was established using independent evaluation by two readers and consultation of a third experienced radiologist in discordant cases. Results Original reports had described 225 negative studies and 67 positive studies for PE. CAD found PE in seven patients originally reported as negative but identified by independent evaluation: emboli were located in segmental (n = 2) and subsegmental arteries (n = 5). The negative predictive value (NPV) of the CAD algorithm was 92% (44/48). On average there were 4.7 false positives (FP) per examination (median 2, range 0–42). In 72% of studies ≤5 FP were found, 13% of studies had ≥10 FP. Conclusion CAD identified small emboli originally missed under clinical conditions and found 93% of the isolated subsegmental emboli. On average there were 4.7 FP per examination.