Maurice Samulski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maurice Samulski has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Nico Karssemeijer
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
3 shared publicationsCarla Boetes
Department of Radiology, Maastricht University Medical Centre, Maastricht, the Netherlands
1 shared publicationGerard J. Den Heeten
National Expert and Training Centre for Breast Cancer Screening, Nijmegen, the Netherlands
1 shared publication- Marina Velikova
Institute for Computing and Information Sciences , Radboud University Nijmegen , Nijmegen , The Netherlands
1 shared publication - Paul J. Groot
University of Cape Town
1 shared publication - Peter J. F. Lucas
University of Twente, Enschede, The Netherlands
1 shared publication
Latest Publications
- 13 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (4) , 1001-1009
Optimizing Case-Based Detection Performance in a Multiview CAD System for Mammography
When reading mammograms, radiologists combine information from multiple views to detect abnormalities. Most computer-aided detection (CAD) systems, however, use primitive methods for inclusion of multiview context or analyze each view independently. In previous research it was found that in mammography lesion-based detection performance of CAD systems can be improved when correspondences between MLO and CC views are taken into account. However, detection at case level detection did not improve. In this paper, we propose a new learning method for multiview CAD systems, which is aimed at optimizing case-based detection performance. The method builds on a single-view lesion detection system and a correspondence classifier. The latter provides class probabilities for the various types of region pairs and correspondence features. The correspondence classifier output is used to bias the selection of training patterns for a multiview CAD system. In this way training can be forced to focus on optimization of case-based detection performance. The method is applied to the problem of detecting malignant masses and architectural distortions. Experiments involve 454 mammograms consisting of four views with a malignant region visible in at least one of the views. To evaluate performance, five-fold cross validation and FROC analysis was performed. Bootstrapping was used for statistical analysis. A significant increase of case-based detection performance was found when the proposed method was used. Mean sensitivity increased by 4.7% in the range of 0.01-0.5 false positives per image.
- 13 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (4) , 1001-1009
Optimizing Case-Based Detection Performance in a Multiview CAD System for Mammography
When reading mammograms, radiologists combine information from multiple views to detect abnormalities. Most computer-aided detection (CAD) systems, however, use primitive methods for inclusion of multiview context or analyze each view independently. In previous research it was found that in mammography lesion-based detection performance of CAD systems can be improved when correspondences between MLO and CC views are taken into account. However, detection at case level detection did not improve. In this paper, we propose a new learning method for multiview CAD systems, which is aimed at optimizing case-based detection performance. The method builds on a single-view lesion detection system and a correspondence classifier. The latter provides class probabilities for the various types of region pairs and correspondence features. The correspondence classifier output is used to bias the selection of training patterns for a multiview CAD system. In this way training can be forced to focus on optimization of case-based detection performance. The method is applied to the problem of detecting malignant masses and architectural distortions. Experiments involve 454 mammograms consisting of four views with a malignant region visible in at least one of the views. To evaluate performance, five-fold cross validation and FROC analysis was performed. Bootstrapping was used for statistical analysis. A significant increase of case-based detection performance was found when the proposed method was used. Mean sensitivity increased by 4.7% in the range of 0.01-0.5 false positives per image.
- 29 October 2010
- Published by Springer Nature
- p. 237-250
Discretisation Does Affect the Performance of Bayesian Networks
- 29 October 2010
- Published by Springer Nature
- p. 237-250
Discretisation Does Affect the Performance of Bayesian Networks
- Open Access
- 9 June 2010
- Published by Springer Nature in European Radiology
- Vol. 20 (10) , 2323-2330
Using computer-aided detection in mammography as a decision support
To evaluate an interactive computer-aided detection (CAD) system for reading mammograms to improve decision making. A dedicated mammographic workstation has been developed in which readers can probe image locations for the presence of CAD information. If present, CAD findings are displayed with the computed malignancy rating. A reader study was conducted in which four screening radiologists and five non-radiologists participated to study the effect of this system on detection performance. The participants read 120 cases of which 40 cases had a malignant mass that was missed at the original screening. The readers read each mammogram both with and without CAD in separate sessions. Each reader reported localized findings and assigned a malignancy score per finding. Mean sensitivity was computed in an interval of false-positive fractions less than 10%. Mean sensitivity was 25.1% in the sessions without CAD and 34.8% in the CAD-assisted sessions. The increase in detection performance was significant (p = 0.012). Average reading time was 84.7 ± 61.5 s/case in the unaided sessions and was not significantly higher when interactive CAD was used (85.9 ± 57.8 s/case). Interactive use of CAD in mammography may be more effective than traditional CAD for improving mass detection without affecting reading time.
- 9 June 2010
- Published by Springer Nature in European Radiology
- Vol. 20 (10) , 2323-2330
Open AccessUsing computer-aided detection in mammography as a decision support
To evaluate an interactive computer-aided detection (CAD) system for reading mammograms to improve decision making. A dedicated mammographic workstation has been developed in which readers can probe image locations for the presence of CAD information. If present, CAD findings are displayed with the computed malignancy rating. A reader study was conducted in which four screening radiologists and five non-radiologists participated to study the effect of this system on detection performance. The participants read 120 cases of which 40 cases had a malignant mass that was missed at the original screening. The readers read each mammogram both with and without CAD in separate sessions. Each reader reported localized findings and assigned a malignancy score per finding. Mean sensitivity was computed in an interval of false-positive fractions less than 10%. Mean sensitivity was 25.1% in the sessions without CAD and 34.8% in the CAD-assisted sessions. The increase in detection performance was significant (p = 0.012). Average reading time was 84.7 ± 61.5 s/case in the unaided sessions and was not significantly higher when interactive CAD was used (85.9 ± 57.8 s/case). Interactive use of CAD in mammography may be more effective than traditional CAD for improving mass detection without affecting reading time.
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6514, 65141J
Classification of mammographic masses using support vector machines and Bayesian networks
In this paper, we compare two state-of-the-art classification techniques characterizing masses as either benign or malignant, using a dataset consisting of 271 cases (131 benign and 140 malignant), containing both a MLO and CC view. For suspect regions in a digitized mammogram, 12 out of 81 calculated image features have been selected for investigating the classification accuracy of support vector machines (SVMs) and Bayesian networks (BNs). Additional techniques for improving their performance were included in their comparison: the Manly transformation for achieving a normal distribution of image features and principal component analysis (PCA) for reducing our high-dimensional data. The performance of the classifiers were evaluated with Receiver Operating Characteristics (ROC) analysis. The classifiers were trained and tested using a k-fold cross-validation test method (k=10). It was found that the area under the ROC curve (Az) of the BN increased significantly (p=0.0002) using the Manly transformation, from Az = 0.767 to Az = 0.795. The Manly transformation did not result in a significant change for SVMs. Also the difference between SVMs and BNs using the transformed dataset was not statistically significant (p=0.78). Applying PCA resulted in an improvement in classification accuracy of the naive Bayesian classifier, from Az = 0.767 to Az = 0.786. The difference in classification performance between BNs and SVMs after applying PCA was small and not statistically significant (p=0.11).
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6514, 65141J
Classification of mammographic masses using support vector machines and Bayesian networks
In this paper, we compare two state-of-the-art classification techniques characterizing masses as either benign or malignant, using a dataset consisting of 271 cases (131 benign and 140 malignant), containing both a MLO and CC view. For suspect regions in a digitized mammogram, 12 out of 81 calculated image features have been selected for investigating the classification accuracy of support vector machines (SVMs) and Bayesian networks (BNs). Additional techniques for improving their performance were included in their comparison: the Manly transformation for achieving a normal distribution of image features and principal component analysis (PCA) for reducing our high-dimensional data. The performance of the classifiers were evaluated with Receiver Operating Characteristics (ROC) analysis. The classifiers were trained and tested using a k-fold cross-validation test method (k=10). It was found that the area under the ROC curve (Az) of the BN increased significantly (p=0.0002) using the Manly transformation, from Az = 0.767 to Az = 0.795. The Manly transformation did not result in a significant change for SVMs. Also the difference between SVMs and BNs using the transformed dataset was not statistically significant (p=0.78). Applying PCA resulted in an improvement in classification accuracy of the naive Bayesian classifier, from Az = 0.767 to Az = 0.786. The difference in classification performance between BNs and SVMs after applying PCA was small and not statistically significant (p=0.11).