WVWouter J. H. Veldkamp

Wouter J. H. Veldkamp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wouter J. H. Veldkamp has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Exploration of Discrepant Recalls Between AI and Human Readers of Malignant Lesions in Digital Mammography Screening

    by Suzanne L. van Winkel, Ioannis Sechopoulos, Alejandro Rodríguez-Ruiz, Wouter J. H. Veldkamp, Gisella Gennaro, Margarita Chevalier, Thomas H. Helbich, Tianyu Zhang, Matthew G. Wallis, Ritse M. Mann

    Background: The integration of artificial intelligence (AI) in digital mammography (DM) screening holds promise for early breast cancer detection, potentially enhancing accuracy and efficiency. However, AI performance is not identical to that of human observers. We aimed to identify common morphological image characteristics of true cancers that are missed by either AI or human screening when their interpretations are discrepant. Methods: Twenty-six breast cancer-positive cases, identified from a large retrospective multi-institutional digital mammography dataset based on discrepant AI and human interpretations, were included in a reader study. Ground truth was confirmed by histopathology or ≥1-year follow-up. Fourteen radiologists assessed lesion visibility, morphological features, and likelihood of malignancy. AI performance was evaluated using receiver operating characteristic (ROC) analysis and area under the curve (AUC). The reader study results were analyzed using interobserver agreement measures and descriptive statistics. Results: AI demonstrated high discriminative capability in the full dataset, with AUCs ranging from 0.903 (95% CI: 0.862–0.944) to 0.946 (95% CI: 0.896–0.996). Cancers missed by AI had a significantly smaller median size (9.0 mm, IQR 6.5–12.0) compared to those missed by human readers (21.0 mm, IQR 10.5–41.0) (p = 0.0014). Cancers in discrepant cases were often described as having ‘low visibility’, ‘indistinct margins’, or ‘irregular shape’. Calcifications were observed in 27% of human-missed cancers (42/154) versus 18% of AI-missed cancers (38/210). A very high likelihood of malignancy was assigned in 32.5% (50/154) of human-missed cancers compared to 19.5% (41/210) of AI-missed cancers. Overall inter-rater agreement was poor to fair (p = 0.396). Furthermore, 50/154 (32.5%) human-missed cancers were deemed to have a very high likelihood of malignancy, compared to 41/210 (19.5%) AI-missed cancers (p = 0.8). Overall inter-rater agreement on the items assessed during the reader study was poor to fair (<0.40), suggesting that interpretation of the selected images was challenging. Conclusions: Lesions missed by AI were smaller and less often calcified than cancers missed by human readers. Cancers missed by AI tended to show lower levels of suspicion than those missed by human readers. While definitive conclusions are premature, the findings highlight the complementary roles of AI and human readers in mammographic interpretation.


  • Open Access

    Lesion detection in digital breast tomosynthesis: human reader experiments indicate no benefit from the integration of information from multiple planes

    by Christiana Balta, Ingrid Reiser, Mireille J. M. Broeders, Wouter J. H. Veldkamp, Ruben E. van Engen, Ioannis Sechopoulos

    PurposeIn digital breast tomosynthesis (DBT), radiologists need to review a stack of 20 to 80 tomosynthesis images, depending upon breast size. This causes a significant increase in reading time. However, it is currently unknown whether there is a perceptual benefit to viewing a mass in the 3D tomosynthesis volume. To answer this question, this study investigated whether adjacent lesion-containing planes provide additional information that aids lesion detection for DBT-like and breast CT-like (bCT) images.MethodHuman reader detection performance was determined for low-contrast targets shown in a single tomosynthesis image at the center of the target (2D) or shown in the entire tomosynthesis image stack (3D). Using simulations, targets embedded in simulated breast backgrounds, and images were generated using a DBT-like (50 deg angular range) and a bCT-like (180 deg angular range) imaging geometry. Experiments were conducted with spherical and capsule-shaped targets. Eleven readers reviewed 1600 images in two-alternative forced-choice experiments. The area under the receiver operating characteristic curve (AUC) and reading time were computed for the 2D and 3D reading modes for the DBT and bCT imaging geometries and for both target shapes.ResultsSpherical lesion detection was higher in 2D mode than in 3D, for both DBT- and bCT-like images (DBT: AUC2D = 0.790, AUC3D = 0.735, P = 0.03; bCT: AUC2D = 0.869, AUC3D = 0.716, P < 0.05), but equivalent for capsule-shaped signals (DBT: AUC2D = 0.891, AUC3D = 0.915, P = 0.19; bCT: AUC2D = 0.854, AUC3D = 0.847, P = 0.88). Average reading time was up to 134% higher for 3D viewing (P < 0.05).ConclusionsFor the detection of low-contrast lesions, there is no inherent visual perception benefit to reviewing the entire DBT or bCT stack. The findings of this study could have implications for the development of 2D synthetic mammograms: a single synthesized 2D image designed to include all lesions present in the volume might allow readers to maintain detection performance at a significantly reduced reading time.

  • Open Access

    Real-Time Person Identification in a Hospital Setting: A Systematic Review

    by Heleen M. Essink, Armelle Knops, Amber M.A. Liqui Lung, C. Nienke van der Meulen, Nino L. Wouters, Aart J. van der Molen, Wouter J.H. Veldkamp, M. Frank Termaat

    In the critical setting of a trauma team activation, team composition is crucial information that should be accessible at a glance. This calls for a technological solution, which are widely available, that allows access to the whereabouts of personnel. This diversity presents decision makers and users with many choices and considerations. The aim of this review is to give a comprehensive overview of available real-time person identification techniques and their respective characteristics. A systematic literature review was performed to create an overview of identification techniques that have been tested in medical settings or already have been implemented in clinical practice. These techniques have been investigated on a total of seven characteristics: costs, usability, accuracy, response time, hygiene, privacy, and user safety. The search was performed on 11 May 2020 in PubMed and the Web of Science Core Collection. PubMed and Web of Science yielded a total n = 265 and n = 228 records, respectively. The review process resulted in n = 23 included records. A total of seven techniques were identified: (a) active and (b) passive Radio-Frequency Identification (RFID) based systems, (c) fingerprint, (d) iris, and (e) facial identification systems and infrared (IR) (f) and ultrasound (US) (g) based systems. Active RFID was largely documented in the included literature. Only a few could be found about the passive systems. Biometric (c, d, and e) technologies were described in a variety of applications. IR and US techniques appeared to be a niche, as they were only spoken of in few (n = 3) studies.


  • Open Access

    Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography

    by Noortje van der Bijl, Raoul M. S. Joemai, Bart J. A. Mertens, Albert de Roos, Wouter J. H. Veldkamp, Jeroen J. Bax, Joanne D. Schuijf, Jacob Geleijns, Lucia J. M. Kroft


  • Open Access

    Increase in perceived case suspiciousness due to local contrast optimisation in digital screening mammography

    by Roelant Visser, Wouter J. H. Veldkamp, David Beijerinck, Petra A. M. Bun, Jan J. M. Deurenberg, Mechli W. Imhof-Tas, Klaas H. Schuur, Miranda M. Snoeren, Gerard J. Den Heeten, Nico Karssemeijer, et al.

    Objectives To determine the influence of local contrast optimisation on diagnostic accuracy and perceived suspiciousness of digital screening mammograms. Methods Data were collected from a screening region in the Netherlands and consisted of 263 digital screening cases (153 recalled,110 normal). Each case was available twice, once processed with a tissue equalisation (TE) algorithm and once with local contrast optimisation (PV). All cases had digitised previous mammograms. For both algorithms, the probability of malignancy of each finding was scored independently by six screening radiologists. Perceived case suspiciousness was defined as the highest probability of malignancy of all findings of a radiologist within a case. Differences in diagnostic accuracy of the processing algorithms were analysed by comparing the areas under the receiver operating characteristic curves (A z ). Differences in perceived case suspiciousness were analysed using sign tests. Results There was no significant difference in A z (TE: 0.909, PV 0.917, P = 0.46). For all radiologists, perceived case suspiciousness using PV was higher than using TE more often than vice versa (ratio: 1.14–2.12). This was significant (P Key Points • Variations among different image processing algorithms for digital screening mammography are large. • Current algorithms still aim for optimal local contrast with a low dynamic range. • Although optimisation of contrast may increase sensitivity, diagnostic accuracy is probably unchanged. • Increased local contrast may render both normal and abnormal structures more conspicuous.


  • Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT

    by Wouter J. H. Veldkamp, Raoul M. S. Joemai, Aart J. van der Molen, Jacob Geleijns

    Purpose: Metal prostheses cause artifacts in computed tomography (CT) images. The purpose of this work was to design an efficient and accurate metal segmentation in raw data to achieve artifact suppression and to improve CT image quality for patients with metal hip or shoulder prostheses.Methods: The artifact suppression technique incorporates two steps: metal object segmentation in raw data and replacement of the segmented region by new values using an interpolation scheme, followed by addition of the scaled metal signal intensity. Segmentation of metal is performed directly in sinograms, making it efficient and different from current methods that perform segmentation in reconstructed images in combination with Radon transformations. Metal signal segmentation is achieved by using a Markov random field model (MRF). Three interpolation methods are applied and investigated. To provide a proof of concept, CT data of five patients with metal implants were included in the study, as well as CT data of a PMMA phantom with Teflon, PVC, and titanium inserts. Accuracy was determined quantitatively by comparing mean Hounsfield (HU) values and standard deviation (SD) as a measure of distortion in phantom images with titanium (original and suppressed) and without titanium insert. Qualitative improvement was assessed by comparing uncorrected clinical images with artifact suppressed images.Results: Artifacts in CT data of a phantom and five patients were automatically suppressed. The general visibility of structures clearly improved. In phantom images, the technique showed reduced SD close to the SD for the case where titanium was not inserted, indicating improved image quality. HU values in corrected images were different from expected values for all interpolation methods. Subtle differences between interpolation methods were found.Conclusions: The new artifact suppression design is efficient, for instance, in terms of preserving spatial resolution, as it is applied directly to original raw data. It successfully reduced artifacts in CT images of five patients and in phantom images. Sophisticated interpolation methods are needed to obtain reliable HU values close to the prosthesis.


  • Dose and perceived image quality in chest radiography

    by Wouter J.H. Veldkamp, Lucia J.M. Kroft, Jacob Geleijns


  • Open Access

    A Technique for Simulating the Effect of Dose Reduction on Image Quality in Digital Chest Radiography

    by Wouter J.H. Veldkamp, Lucia J.M. Kroft, Jan Pieter A. van Delft, Jacob Geleijns

    Purpose: The purpose of this study is to provide a pragmatic tool for studying the relationship between dose and image quality in clinical chest images. To achieve this, we developed a technique for simulating the effect of dose reduction on image quality of digital chest images. Materials and Methods: The technique was developed for a digital charge-coupled-device (CCD) chest unit with slot-scan acquisition. Raw pixel values were scaled to a lower dose level, and a random number representing noise to each specific pixel value was added. After adding noise, raw images were post processed in the standard way. Validation was performed by comparing pixel standard deviation, as a measure of noise, in simulated images with images acquired at actual lower doses. To achieve this, a uniform test object and an anthropomorphic phantom were used. Additionally, noise power spectra of simulated and actual images were compared. Also, detectability of simulated lesions was investigated using a model observer. Results: The mean difference in noise values between simulated and real lower-dose phantom images was smaller than 5% for relevant clinical settings. Noise power spectra appeared to be comparable on average but simulated images showed slightly higher noise levels for higher spatial frequencies and slightly lower noise levels for lower spatial frequencies. Comparable detection performance was shown in simulated and actual images with slightly worse detectability for simulated lower dose images. Conclusion: We have developed and validated a method for simulating dose reduction. Our method seems an acceptable pragmatic tool for studying the relationship between dose and image quality.


  • Detection of Simulated Nodules on Clinical Radiographs: Dose Reduction at Digital Posteroanterior Chest Radiography

    by Lucia J. M. Kroft, Wouter J. H. Veldkamp, Bart J. A. Mertens, Jan Pieter A. van Delft, Jacob Geleijns


  • Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice

    by Wouter J. H. Veldkamp, Lucia J. M. Kroft, Mireille V. Boot, Bart J. A. Mertens, Jacob Geleijns

    The purpose of this study was to assess contrast-detail performance and effective dose of eight different digital chest radiography systems. Digital chest radiography systems from different manufacturers were included: one storage phosphor system, one selenium-coated drum system, and six direct readout systems including four thin-film transistor (TFT) systems and two charge-coupled device (CCD) systems. For measuring image quality, a contrast-detail test object was used in combination with a phantom that simulates the primary and scatter transmission through lung fields (LucAl). Six observers judged phantom images of each modality by soft-copy reading in a four-alternative-forced-choice experiment. The entrance dose was also measured, and the effective dose was calculated for an average patient. Contrast-detail curves were constructed from the observer data. The blocked two-way ANOVA test was used for statistical analysis. Significant difference in contrast-detail performance was found between the systems. Best contrast-detail performance was shown by a CCD system with slot-scan technology, and the selenium-coated drum system was compared to the other six systems (p values ≤0.003). Calculated effective dose varied between 0.010 mSv and 0.032 mSv. Significant differences in contrast-detail performance and effective dose levels were found between different digital chest radiography systems in clinical practice.