KHKari Kulvik Heldal

Kari Kulvik Heldal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kari Kulvik Heldal has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hydrogen sulphide exposure in waste water treatment

    by Åse Dalseth Austigard, Kristin Svendsen, Kari K. Heldal

    The aims of this study was to assess exposure to hydrogen sulphide (H2S) among waste water treatment workers (WWWs), and achieve a better measure of the risks of H2S exposure than only using the eight-hour average value and the ceiling value because the exposure pattern of H2S for WWWs is dominated by short-term peaks. Ninety-three measurements of H2S from 56 WWWs in three cities and three rural areas were collected. All exposure measurements were carried out from the start of the day until lunch time (sampling time 4–5 h) when most of the practical work was performed. The type of tasks and extent of flushing were registered. H2S was measured using direct-reading instruments with logging: OdaLog L2/LL, Dräger X-am 5000 and Dräger Pac 7000 (0.1–200 ppm). Number and duration of peaks for different work tasks, seasons, places and extent of flushing were combined in an exposure index (IN), and evaluated in a mixed-model analysis, building a model aimed to predict exposure for different job tasks. Nine Percent (8 of 93) of all H2S measurements have peaks above 10 ppm; in addition, 15% (14 of 93) have peaks of 5–10 ppm, 35% (33 of 93) have peaks of 1–5 ppm and 65% (62 of 93) have peaks of 0.1–1 ppm. 29% of the measurements of hydrogen sulphide showed no registered level > 0.1 ppm. From the mixed-model analyses we see that exposure level, expressed as H2S index IN, varied between places, work type, season and degree of flushing. For the work in a plant in the capital, the exposure index varied from 0.02 for working in spring doing some flushing, to 0.7 for working at the same plant in winter doing flushing more than three times or more than 10 min. Collecting sewage from cesspools in city 2 in winter doing a lot of flushing gave a hydrogen sulphide index of 230. The use of a H2S index, taking into consideration peak height, duration and number of peaks, could be a tool for exposure assessment for H2S.


  • Biomarkers of inflammation in workers exposed to compost and sewage dust

    by Kari Kulvik Heldal, Lars Barregard, Dag G. Ellingsen

    Purpose The association between exposure during handling of sewage and compost and the serum concentration of inflammatory biomarkers was studied. Methods A total of 44 workers exposed to sewage dust, 47 workers exposed to compost dust and 38 referents from the administrative staff participated. Microbial aerosols were collected by personal inhalable samplers. The concentrations of bacterial cells, spores from fungi and bacteria (actinomycetes) and endotoxins were determined by fluorescence and scanning electron microscopy and the Limulus assay. Fibrinogen, D-dimer, ICAM-1, VCAM-1 and IL-6 were determined by ELISA and C-reactive protein (CRP) by HS-MicroCRP assay in blood samples collected post-shift. Results The exposure to dust ranged from 0.02 to 11 mg/m3, endotoxins from 1 to 3160 EU/m3 and bacteria from 0 to 209 × 106 cells/m3. Fungal (0–41 × 106 spores/m3) and actinomycetes spores (0–590 × 106 actinomycetes spores/m3) were observed only at compost plants. The exposed workers had significantly higher fibrinogen (arithmetic mean 3.3 mg/ml) and CRP (geometric mean 1.5 mg/L) compared to the referents (2.8 and 1.0 mg/L, respectively). The serum concentration of CRP was negatively associated with forced expiratory volume in one second (FEV1) in % of predicted. Exposure to inhalable dust and bacteria was positively associated with the serum concentration of ICAM-1. Conclusions This study suggests that exposure to bacteria and dust when handling sewage and compost may initiate an inflammation shown by an increase in serum concentration of ICAM-1. The higher concentrations of fibrinogen and CRP in exposed workers compared to the referents may reflect a low-grade systemic inflammation.


  • Open Access

    Pneumoproteins in sewage workers exposed to sewage dust

    by Kari Kulvik Heldal, Lars Barregard, Per Larsson, Dag G. Ellingsen

    Purpose The association between exposure to bacteria and endotoxins in sewage dust and the serum concentrations of pneumoproteins in sewage treatment plant workers were studied. Methods Forty-four workers from eight sewage treatment plants and 38 reference workers participated in the study. Microbial aerosol was collected by personal inhalable samplers. The concentrations of bacteria and endotoxins were determined by fluorescence microscopy and the Limulus assay, respectively. Pneumoproteins (Clara cell protein: CC16, and Surfactant proteins A and D: SP-A, SP-D) were determined by ELISA in blood samples collected post-shift. Results The exposure to dust ranged from 0.02 to 9.3 (geometric mean (GM) 0.3 mg/m3, of bacteria from 0.3 to 4,900 × 103 (GM 27 × 103) cells/m3 and endotoxins from 1 to 3,160 (GM 28) EU/m3. The exposed workers had lower CC16 [arithmetic mean (AM) 4.9 ng/ml] compared to the referents (AM 6.4 ng/ml, p < 0.01). No significant difference was observed for SP-D and SP-A. Exposure to bacteria was positively associated with CC16 (p < 0.05) and SP-D (p < 0.05), adjusting for possible confounders. Conclusions This study showed that exposed workers had lower serum concentration of CC16 as compared to the referents, which may reflect a long-term effect on secretion of these pneumoproteins. The positive association between exposure to bacteria and the serum concentrations of CC16 and SP-D may be explained by a transient increased permeability of the lung–blood barrier.


    • 1 January 2010
      • Vol. 17  (2) , 263-8

    Exposure, symptoms and airway inflammation among sewage workers.

    by Kari Kulvik Heldal, Lene Madsø, Per Ole Huser, Wijnand Eduard

    The purpose of the study was to determine the associations between dust, endotoxins and bacterial exposure, and health effects in sewage workers. Exposure of 19 workers handling dry sludge and 25 other sewage workers was measured. Controls were office workers from compost and sewage plants. Spirometry, acoustic rhinometry and nitric oxide in exhaled air were performed before and after exposure were measured. CRP was measured in blood samples. It was found that workers handling dry sludge were exposed to higher levels of dust and endotoxins than other workers and reported more airway and systemic symptoms than controls. Compared to controls, FEV(1)/FVC was 0.12 lower in workers handling dry sludge and 0.05 lower in other sewage workers. Nose irritation, cough and headache were more prevalent in workers handling dry sludge (ORs 2.3-23), and together with unusual tiredness associated with endotoxins and/or dust, ORs 2.9-34 for-10-fold increases in exposure. Cross-shift decreases of nasal dimensions were larger in workers handling dry sludge than controls and were associated with dust and endotoxin exposure. It was concluded that workers handling dry sludge were higher exposed to endotoxins and dust than other sewage workers and also reported more respiratory and systemic symptoms. Exposure-response relationships were found for nasal dimensions, nose irritation and systemic symptoms.


  • Associations between acute symptoms and bioaerosol exposure during the collection of household waste

    by Kari Kulvik Heldal, Wijnand Eduard

    Background: A study was performed to investigate associations between work‐related symptoms and bioaerosol exposure in 22 workers collecting waste separated at source and mixed household waste.Methods: Full work shift exposures to bacteria (spherical and rod‐shaped) fungal spores, endotoxins, and total dust were measured. Symptoms experienced during work on the day that exposure was measured were recorded by use of a short questionnaire. Questions were posed on respiratory symptoms, systemic effects such as headache, tiredness, and gastrointestinal symptoms.Results: The median exposure levels of bacteria and fungal spores were 0.4 and 0.1 × 106/m3, respectively. The exposure to rod‐shaped bacteria (7% of the bacteria count), endotoxins (1.8 EU/m3), and dust (0.2 mg/m3) was low. The symptoms most often reported were unusual tiredness (24%), headache (22%), cough (15%), and irritation in eyes and nose (10 and 17%). These symptoms were also found to be associated to microbial components.Conclusions: The results suggest that acute work‐related nose irritation is associated with exposure to bacteria. Rod‐shaped bacteria were also associated with nose irritation and unusual tiredness. It is likely that cough is associated to fungal spores, while other associations which were found could be due to confounding. Am. J. Ind. Med. 46:253–260, 2004.


  • Open Access

    Upper airway inflammation in waste handlers exposed to bioaerosols

    by K K Heldal, A S Halstensen, J Thorn, P Djupesland, I Wouters, W Eduard, T S Halstensen

    Aims:To examine work associated upper airway inflammation in 31 waste handlers, and to correlate these findings with personally monitored exposure to different bioaerosol components.Methods:Cell differentials, interleukin 8 (IL-8), myeloperoxidase (MPO), and eosinophilic cationic protein (ECP) were examined in NAL (nasal lavage), and swelling of the nasal mucosa was determined by acoustic rhinometry before work start on Monday and the following Thursday. Bioaerosol exposure was determined by personal full shift exposure measurements on Monday, Tuesday, and Wednesday and analysed for total bacteria, fungal spores, endotoxin, and β(1→3)-glucans.Results:The increased percentage of neutrophils from Monday (28%) to Thursday (46%) correlated with increases in ECP (rS= 0.71, p < 0.001) and MPO (rS= 0.38, p < 0.05), and showed a close to significant correlation with nasal swelling (rS= −0.55, p = 0.07). The Thursday levels of neutrophils, MPO, and IL-8 were associated with the exposure to fungal spores (range 0–2.0 × 106/m3) and endotoxin (range 4–183 EU/m3) measured the day before, and the median exposure to β(1→3)-glucans (range 3–217 ng/m3), respectively (rS= 0.47–0.54, p < 0.01). Swelling of the nasal mucosa was associated with the fungal spore and β(1→3)-glucan exposure (rS= 0.58–0.59, p < 0.05).Conclusion:These results are based on a relatively small population, and conclusions must be drawn with care. The results suggested that a moderate exposure to fungal spores, endotoxins, and β(1→3)-glucans during waste handling induced upper airway inflammation dominated by neutrophil infiltration and swelling of the nasal mucosa.


  • Airway inflammation in waste handlers exposed to bioaerosols assessed by induced sputum

    by K.K. Heldal, A.S. Halstensen, J. Thorn, W. Eduard, T.S. Halstensen

    Work-associated lower airway inflammation in waste collectors was examined by induced sputum and correlated with the bioaerosol exposure.Organic waste collectors (n=25) underwent induced sputum collection and spirometry before work on Monday and the following Thursday. Total cells, cell differentials, interleukin (IL)-8 and eosinophilic cationic protein were determined. Personal full-shift exposure measurements were performed Monday, Tuesday and Wednesday and analysed for total bacteria, fungal spores, endotoxins and β(1–3)-glucans.The percentage of neutrophils (46–58%) and the IL-8 concentration (1.1–1.4 ng·mL−1) increased from Monday to Thursday. Forced expiratory volume in one second (FEV1) was significantly reduced on Thursday, and the decrease in FEV1/forced vital capacity correlated with the increase in the percentage of neutrophils. The median exposure to endotoxin (range 7–180 EU·m−3) and β(1–3)-glucan (range 5–220 ng·m−3) was correlated with the increase in IL-8.Bioaerosol exposure during waste collection induced an inflammatory response in the lower airways, characterised by neutrophils and interleukin-8 secretion, that influenced the lung function. The inflammatory response was related to microbial components in the bioaerosol and was more pronounced for endotoxin than β(1–3)-glucan exposure. No associations were found for mould spores or bacteria.


  • Experimental generation of organic dust from compostable household waste

    by Kari Kulvik Heldal, Niels O. Breum, Birgitte H. Nielsen, Ken Wilkins

    The objective was to assess the influence of different waste storage systems on the emission of bioaerosols and gases from compostable household waste. Batches of waste were stored for 14 days in different storage systems: ventilated containers (compostainers) with or without added structure material and closed containers with or without a preservation additive. The microbial potential of the waste was measured with a rotating drum after storage. The weight loss in the compostainers (39%) was higher than in the closed containers (9%). Hydrogen sulphide and mercaptans developed in the closed container, and the concentration of ammonia increased continuously in both systems to 140 ppm. The microbial content for the incubated waste was high for closed containers compared to compostainers, and waste in closed containers generated a liquid rich in endotoxin and bacteria. The aerosols emitted from the waste consisted mainly of fungal spores, especially Aspergillus fumigatus, and no significant differences were observed between the systems. The endotoxin potential was high for waste stored in closed containers. The use of a preservative prevented microbial growth and reduced the emission of bioaerosols and gases substantially.