DNDionne A. Noordhof

Dionne A. Noordhof

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dionne A. Noordhof has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Gross Efficiency at Sea Level and Moderate Altitude

    by Dionne A. Noordhof, Thijs Schoots, Derk Hoekert, Jos J. de Koning, Carl Foster

  • Open Access

    The between and within day variation in gross efficiency

    by Dionne A. Noordhof, Jos J. de Koning, Teun van Erp, Bart van Keimpema, Daan de Ridder, Ruby Otter, Carl Foster

    Before the influence of divergent factors on gross efficiency (GE) [the ratio of mechanical power output (PO) to metabolic power input (PI)] can be assessed, the variation in GE between days, i.e. the test–retest reliability, and the within day variation needs to be known. Physically active males (n = 18) performed a maximal incremental exercise test to obtain VO2max and PO at VO2max (PVO2max), and three experimental testing days, consisting of seven submaximal exercise bouts evenly distributed over the 24 h of the day. Each submaximal exercise bout consisted of six min cycling at 45, 55 and 65% PVO2max, during which VO2 and RER were measured. GE was determined from the final 3 min of each exercise intensity with: GE = (PO/PI) × 100%. PI was calculated by multiplying VO2 with the oxygen equivalent. GE measured during the individually highest exercise intensity with RER F = 2.70, p = 0.08), which resulted in lower and upper boundaries of the 95% limits of agreement of 19.6 and 20.8%, respectively, around a mean GE of 20.2%. Although there were minor within day variations in GE, differences in GE over the day were not significant (F = 0.16, p = 0.99). The measurement of GE during cycling at intensities approximating VT is apparently very robust, a change in GE of ~0.6% can be reliably detected. Lastly, GE does not display a circadian rhythm so long as the criteria of a steady-state VO2 and RER <1.0 are applied.


  • The Variation in Gross Efficiency within the Day

    by Dionne A. Noordhof, Jos J. de Koning, Bart van Keimpema, Teun van Erp, Carl Foster

  • The Maximal Accumulated Oxygen Deficit Method

    by Dionne A. Noordhof, Jos J. de Koning, Carl Foster

    The maximal accumulated oxygen deficit (MAOD) method has been extensively, but unfortunately not very methodically, used; the procedure used to determine the MAOD varies considerably. Therefore, this review evaluates the effect of different numbers and durations of submaximal exercise bouts on the linear power output (PO)-oxygen uptake (V̇O2) relationship and thus the MAOD. Changing the number and duration of the submaximal exercise bouts substantially influences the calculated MAOD when relatively long submaximal exercise bouts are used and no fixed value of the y-intercept is forced into the linear regression line. This is most likely due to non-linearity of the PO-V̇O2 relationship for exercise intensities above the lactate threshold (LT). Non-linearity of the PO-V̇O2 relationship is probably caused by the development of a slow component in V̇O2 during submaximal exercise at intensities above the LT. Thus, it is important to standardize the number, duration and intensity of submaximal exercise bouts necessary to establish the PO-V̇O2 relationship. Beyond changing the number and duration of the submaximal exercise bouts, the effect of different supramaximal exercise bouts on the calculated MAOD has been investigated. While it has become clear that different exercise protocols result in relatively similar values of the MAOD, a closer look at individual data suggests that it may be important to choose an exercise protocol that is representative of the athlete’s event. The validity of the MAOD method was studied by different authors comparing the MAOD with metabolic measurements of anaerobic adenosine triphosphate (ATP) production. The main limitation with the metabolic measurements of anaerobic ATP production from muscle biopsy data is that the active muscle mass is unknown, which makes it hard to accurately study the validity of the MAOD method. From the studies that evaluated the reliability of the MAOD method it is clear that the MAOD method may not be a reliable measure of anaerobic capacity. From these findings it can be concluded that the MAOD method may have limitations as a valid and reliable measure of anaerobic capacity and needs to be further improved. We suggest the use of 10 x 4 minute submaximal exercise bouts and a fixed value of the y-intercept for the construction of the linear PO-V̇O2 relationship, after which the MAOD can be determined during a supramaximal exercise protocol specific for the athlete’s event. This method will lead to a more robust PO-V̇O2 relationship and will therefore result in more valid and reliable results.