JBJan A. N. Buytaert

Jan A. N. Buytaert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan A. N. Buytaert has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MicroFilament Analyzer identifies actin network organizations in epidermal cells ofArabidopsis thalianaroots

    by Eveline Jacques, Michal Lewandowski, Jan Buytaert, Yves Fierens, Jean-Pierre Verbelen, Kris Vissenberg

    The plant cytoskeleton plays a crucial role in the cells’ growth and development during different developmental stages and it undergoes many rearrangements. In order to describe the arrangements of the F-actin cytoskeleton in root epidermal cells of Arabidopsis thaliana, the recently developed software MicroFilament Analyzer (MFA) was exploited. This software enables high-throughput identification and quantification of the orientation of filamentous structures on digital images in a highly standardized and fast way. Using confocal microscopy and transgenic GFP-FABD2-GFP plants the actin cytoskeleton was visualized in the root epidermis. MFA analysis revealed that during the early stages of cell development F-actin is organized in a mainly random pattern. As the cells grow, they preferentially adopt a longitudinal organization, a pattern that is also preserved in the largest cells. In the evolution from young to old cells, an approximately even distribution of transverse, oblique or combined orientations is always present besides the switch from random to a longitudinal oriented actin cytoskeleton.


  • Full-Field Thickness Distribution of Human Tympanic Membrane Obtained with Optical Coherence Tomography

    by Sam Van der Jeught, Joris J. J. Dirckx, Johan R. M. Aerts, Adrian Bradu, Adrian Gh Podoleanu, Jan A. N. Buytaert

    The full-field thickness distribution, three-dimensional surface model and general morphological data of six human tympanic membranes are presented. Cross-sectional images were taken perpendicular through the membranes using a high-resolution optical coherence tomography setup. Five normal membranes and one membrane containing a pathological site are included in this study. The thickness varies strongly across each membrane, and a great deal of inter-specimen variability can be seen in the measurement results, though all membranes show similar features in their respective relative thickness distributions. Mean thickness values across the pars tensa ranged between 79 and 97 μm; all membranes were thinnest in the central region between umbo and annular ring (50–70 μm), and thickness increased steeply over a small distance to approximately 100–120 μm when moving from the central region either towards the peripheral rim of the pars tensa or towards the manubrium. Furthermore, a local thickening was noticed in the antero–inferior quadrant of the membranes, and a strong linear correlation was observed between inferior–posterior length and mean thickness of the membrane. These features were combined into a single three-dimensional model to form an averaged representation of the human tympanic membrane. 3D reconstruction of the pathological tympanic membrane shows a structural atrophy with retraction pocket in the inferior portion of the pars tensa. The change of form at the pathological site of the membrane corresponds well with the decreased thickness values that can be measured there.


  • Open Access

    MicroCT versus sTSLIM 3D Imaging of the Mouse Cochlea

    by Jan A.N. Buytaert, Shane B. Johnson, Manuel Dierick, Wasil H.M. Salih, Peter A. Santi

    We made a qualitative and quantitative comparison between a state-of-the-art implementation of micro-Computed Tomography (microCT) and the scanning Thin-Sheet Laser Imaging Microscopy (sTSLIM) method, applied to mouse cochleae. Both imaging methods are non-destructive and perform optical sectioning, respectively, with X-rays and laser light. MicroCT can be used on fresh or fixed tissue samples and is primarily designed to image bone rather than soft tissues. It requires complex back-projection algorithms to produce a two-dimensional image, and it is an expensive instrument. sTSLIM requires that a specimen be chemically fixed, decalcified, and cleared; but it produces high-resolution images of soft and bony tissues with minimum image postprocessing and is less expensive than microCT. In this article, we discuss the merits and disadvantages of each method individually and when combined.


  • Open Access

    The OPFOS Microscopy Family: High-Resolution Optical Sectioning of Biomedical Specimens

    by Jan A. N. Buytaert, Emilie Descamps, Dominique Adriaens, Joris J. J. Dirckx

    We report on the recently emerging (laser) light-sheet-based fluorescence microscopy field (LSFM). The techniques used in this field allow to study and visualize biomedical objects nondestructively in high resolution through virtual optical sectioning with sheets of laser light. Fluorescence originating in the cross-section of the sheet and sample is recorded orthogonally with a camera. In this paper, the first implementation of LSFM to image biomedical tissue in three dimensions—orthogonal-plane fluorescence optical sectioning microscopy (OPFOS)—is discussed. Since then many similar and derived methods have surfaced, (SPIM, ultramicroscopy, HR-OPFOS, mSPIM, DSLM, TSLIM, etc.) which we all briefly discuss. All these optical sectioning methods create images showing histological detail. We illustrate the applicability of LSFM on several specimen types with application in biomedical and life sciences.


  • Open Access

    Realistic 3D Computer Model of the Gerbil Middle Ear, Featuring Accurate Morphology of Bone and Soft Tissue Structures

    by Jan A. N. Buytaert, Wasil H. M. Salih, Manual Dierick, Patric Jacobs, Joris J. J. Dirckx

    In order to improve realism in middle ear (ME) finite-element modeling (FEM), comprehensive and precise morphological data are needed. To date, micro-scale X-ray computed tomography (μCT) recordings have been used as geometric input data for FEM models of the ME ossicles. Previously, attempts were made to obtain these data on ME soft tissue structures as well. However, due to low X-ray absorption of soft tissue, quality of these images is limited. Another popular approach is using histological sections as data for 3D models, delivering high in-plane resolution for the sections, but the technique is destructive in nature and registration of the sections is difficult. We combine data from high-resolution μCT recordings with data from high-resolution orthogonal-plane fluorescence optical-sectioning microscopy (OPFOS), both obtained on the same gerbil specimen. State-of-the-art μCT delivers high-resolution data on the 3D shape of ossicles and other ME bony structures, while the OPFOS setup generates data of unprecedented quality both on bone and soft tissue ME structures. Each of these techniques is tomographic and non-destructive and delivers sets of automatically aligned virtual sections. The datasets coming from different techniques need to be registered with respect to each other. By combining both datasets, we obtain a complete high-resolution morphological model of all functional components in the gerbil ME. The resulting 3D model can be readily imported in FEM software and is made freely available to the research community. In this paper, we discuss the methods used, present the resulting merged model, and discuss the morphological properties of the soft tissue structures, such as muscles and ligaments.


  • Tomographic imaging of macroscopic biomedical objects in high resolution and three dimensions using orthogonal-plane fluorescence optical sectioning

    by Jan A. N. Buytaert, Joris J. J. Dirckx

    A new optical-fluorescence microscopy technique, called HR-OPFOS, is discussed and situated among similar OPFOS-implementations. OPFOS stands for orthogonal-plane fluorescence optical sectioning and thus is categorized as a laser light sheet based fluorescence microscopy method. HR-OPFOS is used to make tomographic recordings of macroscopic biomedical specimens in high resolution. It delivers cross sections through the object under study with semi-histological detail, which can be used to create three-dimensional computer models for finite-element modeling or anatomical studies. The general innovation of this class of microscopy setup consists of the separation of the illumination and observation axes, but now in our setup combined with focal line scanning to improve sectioning resolution. HR-OPFOS is demonstrated on gerbil hearing organs and on mouse and bird brains. The necessary specimen preparation is discussed.


  • Moiré profilometry using liquid crystals for projection and demodulation

    by Jan A. N. Buytaert, Joris J. J. Dirckx

    A projection moiré profilometer is presented in which both projection and optical demodulation are realized with liquid crystal light modulators. The computer generated grids, realized on thin film transistor matrices, allow phase-stepping and discrete grid averaging without the need for any mechanically moving component. Spatial line pitch and phase steps can thus be readily adjusted to suit the measurement precision and object geometry. The device is able to perform topographic measurements with a height resolution of 15µm on every pixel of the recording device.


  • Open Access

    Morphology and function of Bast’s valve: additional insight in its functioning using 3D-reconstruction

    by R. Hofman, J. M. Segenhout, J. A. N. Buytaert, J. J. J. Dirckx, H. P. Wit

    The utriculo-endolymphatic valve was discovered by Bast in 1928. The function of Bast’s valve is still unclear. By means of orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy 3D-reconstructions of the valve and its surrounding region are depicted. The shape of the duct at the utricular side is that of a flattened funnel. In the direction of the endolymphatic duct and sac this funnel runs into a very narrow duct. The valve itself has a rigid ‘arch-like’ configuration. The opposing thin, one cell-layer thick, utricular membrane is highly compliant. We propose that opening and closure of the valve occurs through movement of the flexible base/utricular membrane away from and toward the relatively rigid valve lip.


  • Design considerations in projection phase-shift moiré topography based on theoretical analysis of fringe formation

    by Jan A. N. Buytaert, Joris J. J. Dirckx

    Moiré topography is a well-established optical technique to measure the shape of three-dimensional surfaces, based on the geometric interference between an optical grid and its image deformed by an object surface. The technique produces fringes that represent contours of equal height, and from the recordings of several phase-shifted topograms surface height coordinates can be calculated. To perform these calculations, it is assumed that object height variation is small in comparison with the measurement setup dimensions, and this approximation leads to systematic errors in measurement accuracy. We present the mathematical description of the fringe formation process in projection moiré topography, and on the basis of these equations we establish the relation between setup geometry and upper limits of the systematic measurement errors. We derive the equations that determine design specifications needed to reduce the effects of approximations to be below the measurement resolution of the setup. It is shown that setup geometry should be adapted to the gray-scale measurement resolution of the imaging system. We show that, using an iterative correction from one fringe order to the next, measurement accuracy can be maintained over the entire object depth.