Michaela Gstoettner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michaela Gstoettner has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Bernhard Glodny
Medical University Innsbruck
2 shared publicationsChristian M. Bach
Medical University Innsbruck
2 shared publicationsMartin Thaler
Medical University Innsbruck
2 shared publicationsChristian Michael Bach
Department of Orthopaedic Surgery, Innsbruck Medical University, Anichstr 35, Innsbruck, Austria
1 shared publicationChristian Raschner
1 shared publicationEva Dirnberger
1 shared publication
Latest Publications
- Open Access
- 19 July 2011
- Published by Springer Nature in European Spine Journal
- Vol. 20 (10) , 1771-1779
Inter- and intraobserver reliability assessment of computed tomographic 3D measurement of pedicles in scoliosis and size matching with pedicle screws
In patients with scoliosis, the morphology of the pedicles differs from those in normal spines. Preoperative three-dimensional information of these complex anatomic situations means a great advantage for the surgeon in order to assess which pedicles can be instrumented safely avoiding screw misplacement and for the decisions in choosing the appropriate screw size. The objective of this study was to measure pedicle dimensions in scoliotic spines on three-dimensional computed tomographic (CT) scans and to determine the intra- and interobserver reliability of the method. Additionally, the pedicles that cannot be instrumented safely by available screws were identified. All pedicles from T1 to L5 in 30 patients with scoliosis were measured by two independent observers. The pedicle width, height and length were assessed for two times with a 3-week interval. Intraclass correlation coefficients were used to determine the intra- and interobserver reliabilities. The diameters of the pedicles were matched with the dimensions of the smallest available pedicle screws of scoliosis implant systems. The intrarater reliability was strong in 60% of the parameters and moderate in 40%. The interrater reliability was strong in all parameters but in pedicle length. The concave-sided pedicles in the curve revealed to be smaller compared to the convex-sided ones. The highest percentage of size mismatch was found in levels T7 (31%) and T8 (33%). Measurement of pedicle dimensions on three-dimensional CT scans is a reliable but time-consuming procedure to assess pedicle dimensions. CT measuring should be reserved for special cases, where the anatomic situation remains unclear despite X-ray. In scoliotic spines, one-third of the mid-thoracic pedicles cannot be instrumented safely with pedicle screws.
- 19 July 2011
- Published by Springer Nature in European Spine Journal
- Vol. 20 (10) , 1771-1779
Open AccessInter- and intraobserver reliability assessment of computed tomographic 3D measurement of pedicles in scoliosis and size matching with pedicle screws
In patients with scoliosis, the morphology of the pedicles differs from those in normal spines. Preoperative three-dimensional information of these complex anatomic situations means a great advantage for the surgeon in order to assess which pedicles can be instrumented safely avoiding screw misplacement and for the decisions in choosing the appropriate screw size. The objective of this study was to measure pedicle dimensions in scoliotic spines on three-dimensional computed tomographic (CT) scans and to determine the intra- and interobserver reliability of the method. Additionally, the pedicles that cannot be instrumented safely by available screws were identified. All pedicles from T1 to L5 in 30 patients with scoliosis were measured by two independent observers. The pedicle width, height and length were assessed for two times with a 3-week interval. Intraclass correlation coefficients were used to determine the intra- and interobserver reliabilities. The diameters of the pedicles were matched with the dimensions of the smallest available pedicle screws of scoliosis implant systems. The intrarater reliability was strong in 60% of the parameters and moderate in 40%. The interrater reliability was strong in all parameters but in pedicle length. The concave-sided pedicles in the curve revealed to be smaller compared to the convex-sided ones. The highest percentage of size mismatch was found in levels T7 (31%) and T8 (33%). Measurement of pedicle dimensions on three-dimensional CT scans is a reliable but time-consuming procedure to assess pedicle dimensions. CT measuring should be reserved for special cases, where the anatomic situation remains unclear despite X-ray. In scoliotic spines, one-third of the mid-thoracic pedicles cannot be instrumented safely with pedicle screws.
- 1 March 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (3) , 819-824
CT Angiography for Anterior Lumbar Spine Access: High Radiation Exposure and Low Clinical Relevance
Ve CT angiography and (2) whether CT angiography affects planning of anterior lumbar spine surgeries. Patients and Methods We assessed preoperative CT angiograms of 28 patients undergoing anterior spine surgery. The level of aortic bifurcation, iliac vein confluence, course of the ascending lumbar vein, central sacral vessels, and any vascular variation were mapped. We determined the effective dose of radiation and recorded whether the preoperative CT angiography influenced surgical planning. Results We observed variations in the location of the aortic bifurcation and the iliac vein confluence. In 32% of patients, there were accessory renal arteries originating from the aorta; 7% had a rudimentary persistent left-sided caval vein. The findings did not change the plan for surgery in any patient. We detected high organ radiation dosages (mSv) for the stomach (63 mSv), liver (58 mSv), urinary bladder (47 mSv), and colon (46 mSv); other high exposure dosages involved the lungs, bone marrow, ovaries, and uterus. Conclusions About one in 1919 men and one in 2971 women undergoing CT angiography therefore are expected to have colon cancer develop, and one in 2781 men and one in 2856 women are expected to have cancer of the urinary bladder develop. CT angiography is of low value for preoperative planning for anterior access to the lumbar spine and should be avoided to prevent radiation-induced damage. Level of Evidence Level II, diagnostic study....
- 1 March 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (3) , 819-824
CT Angiography for Anterior Lumbar Spine Access: High Radiation Exposure and Low Clinical Relevance
Ve CT angiography and (2) whether CT angiography affects planning of anterior lumbar spine surgeries. Patients and Methods We assessed preoperative CT angiograms of 28 patients undergoing anterior spine surgery. The level of aortic bifurcation, iliac vein confluence, course of the ascending lumbar vein, central sacral vessels, and any vascular variation were mapped. We determined the effective dose of radiation and recorded whether the preoperative CT angiography influenced surgical planning. Results We observed variations in the location of the aortic bifurcation and the iliac vein confluence. In 32% of patients, there were accessory renal arteries originating from the aorta; 7% had a rudimentary persistent left-sided caval vein. The findings did not change the plan for surgery in any patient. We detected high organ radiation dosages (mSv) for the stomach (63 mSv), liver (58 mSv), urinary bladder (47 mSv), and colon (46 mSv); other high exposure dosages involved the lungs, bone marrow, ovaries, and uterus. Conclusions About one in 1919 men and one in 2971 women undergoing CT angiography therefore are expected to have colon cancer develop, and one in 2781 men and one in 2856 women are expected to have cancer of the urinary bladder develop. CT angiography is of low value for preoperative planning for anterior access to the lumbar spine and should be avoided to prevent radiation-induced damage. Level of Evidence Level II, diagnostic study....
- 1 February 2011
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 24 (1) , 44-49
Restoration and Preservation of Disc Height and Segmental Lordosis With Circumferential Lumbar Fusion
Retrospective radiographic analysis. To determine whether restoration and preservation of (a) disc height and (b) segmental lordosis differ between patients treated with circumferential lumbar fusion using a bone graft or a cage for anterior support. Restoration of disc height and lordosis is considered to be of crucial importance in circumferential fusion (CF). To determine whether restoration and preservation of disc height and segmental lordosis are dependent on the type of anterior support used, we compared the use of a cage with that of a bone graft in CF. We retrospectively analyzed disc height and segmental lordosis in patients treated with primary lumbar monosegmental CF. The minimum period of follow-up was 9 months. A cage was used for anterior support in 23 patients and a bone graft in a further 23 patients. Disc height was determined on radiographs using an earlier introduced and validated distortion-compensated roentgen analysis, which was developed to compensate for distortion in central projection, off-center position, variation of stature, axial rotation, and lateral tilt of the spine. Disc height was restored in both groups but differences between preoperative and postoperative disc heights were significantly greater in the cage group (P=0.006). The cage also proved to be superior with regard to disc height preservation after follow-up (P=0.001). In addition, there was significantly less postoperative loss of segmental lordosis in the cage group (P=0.026). The cage proved superior to the bone graft as anterior support in CF with respect to restoration/preservation of lordosis and disc height. However, no conclusions concerning clinical outcome or cost effectiveness can be drawn on the basis of this study.
- 1 February 2011
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 24 (1) , 44-49
Restoration and Preservation of Disc Height and Segmental Lordosis With Circumferential Lumbar Fusion
Retrospective radiographic analysis. To determine whether restoration and preservation of (a) disc height and (b) segmental lordosis differ between patients treated with circumferential lumbar fusion using a bone graft or a cage for anterior support. Restoration of disc height and lordosis is considered to be of crucial importance in circumferential fusion (CF). To determine whether restoration and preservation of disc height and segmental lordosis are dependent on the type of anterior support used, we compared the use of a cage with that of a bone graft in CF. We retrospectively analyzed disc height and segmental lordosis in patients treated with primary lumbar monosegmental CF. The minimum period of follow-up was 9 months. A cage was used for anterior support in 23 patients and a bone graft in a further 23 patients. Disc height was determined on radiographs using an earlier introduced and validated distortion-compensated roentgen analysis, which was developed to compensate for distortion in central projection, off-center position, variation of stature, axial rotation, and lateral tilt of the spine. Disc height was restored in both groups but differences between preoperative and postoperative disc heights were significantly greater in the cage group (P=0.006). The cage also proved to be superior with regard to disc height preservation after follow-up (P=0.001). In addition, there was significantly less postoperative loss of segmental lordosis in the cage group (P=0.026). The cage proved superior to the bone graft as anterior support in CF with respect to restoration/preservation of lordosis and disc height. However, no conclusions concerning clinical outcome or cost effectiveness can be drawn on the basis of this study.