Bin Ni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bin Ni has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Qunfeng Guo
Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China
25 shared publicationsXiang Guo
Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China
15 shared publicationsXuhua Lu
From the Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, People's Republic of China
11 shared publicationsJian Yang
Changzheng Hospital, The Second Military Medical University
10 shared publicationsFengjin Zhou
‡ Department of Orthopedics, Fuzhou General Hospital, Nanjing Military Command, Fuzhou, P.R. China ¶ Department of Orthopedics, No. 451 Hospital of PLA, Xi'an, P.R. China
9 shared publicationsJinshui Chen
‡Department of Orthopedics, Fuzhou General Hospital, Nanjing Military Command, Fuzhou, P.R. China;§Department of Orthopedics, Changzheng Hospital, The Second Military Medical University, Shanghai, P.R. China;¶Department of Orthopedics, No. 451 Hospital of PLA, Xi'an, P.R. China
8 shared publications
Latest Publications
- 5 June 2018
- Published by Springer Nature
- p. 3-14
Applied Anatomy and Biomechanics of the Atlantoaxial Joint Complex
- 5 June 2018
- Published by Springer Nature
- p. 3-14
Applied Anatomy and Biomechanics of the Atlantoaxial Joint Complex
- 1 October 2016
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 149, 39-43
Influence of the T1-slope on sagittal alignment of the subaxial cervical spine after posterior atlantoaxial fusion in os odontoideum
- 1 October 2016
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 149, 39-43
Influence of the T1-slope on sagittal alignment of the subaxial cervical spine after posterior atlantoaxial fusion in os odontoideum
- 1 July 2016
- Published by Elsevier in World Neurosurgery
- Vol. 91, 326-331
Posterior Open Reduction and Interlaminae Compression Fusion for Os Odontoideum with Atlantoaxial Dislocation
- 1 July 2016
- Published by Elsevier in World Neurosurgery
- Vol. 91, 326-331
Posterior Open Reduction and Interlaminae Compression Fusion for Os Odontoideum with Atlantoaxial Dislocation
- 1 May 2016
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 78 (5) , 735-741
New Posterior Atlantoaxial Restricted Non-Fusion Fixation for Atlantoaxial Instability
BACKGROUND:. Loss of axial rotation and lateral bending after atlantoaxial fusion reduces a patient's quality of life. Therefore, effective, nonfusion f
- 1 May 2016
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 78 (5) , 735-741
New Posterior Atlantoaxial Restricted Non-Fusion Fixation for Atlantoaxial Instability
BACKGROUND:. Loss of axial rotation and lateral bending after atlantoaxial fusion reduces a patient's quality of life. Therefore, effective, nonfusion f
- 1 March 2016
- Published by Elsevier in World Neurosurgery
- Vol. 87, 521-528
Subaxial Cervical Intradiscal Pressure and Segmental Kinematics Following Atlantoaxial Fixation in Different Angles
- 1 March 2016
- Published by Elsevier in World Neurosurgery
- Vol. 87, 521-528
Subaxial Cervical Intradiscal Pressure and Segmental Kinematics Following Atlantoaxial Fixation in Different Angles
- 1 February 2016
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 141, 13-18
Deep surgical site infection after anterior decompression and fusion with plate fixation for cervical spondylotic radiculopathy or myelopathy
- 1 February 2016
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 141, 13-18
Deep surgical site infection after anterior decompression and fusion with plate fixation for cervical spondylotic radiculopathy or myelopathy
- 1 February 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (3) , E168-E174
Posterior Reduction and Temporary Fixation for Odontoid Fracture
Study Design. A prospective study. Objective. To evaluate the outcomes of posterior reduction and temporary fixation using the C1–C2 screw-rod system for odontoid fracture unsuitable for anterior screw fixation. Summary of Background Data. Anterior screw fixation has become the most widely used surgical procedure for the stabilization of odontoid fractures. However, if there is any contraindication for anterior fixation, posterior atlantoaxial fusion is preferred, eliminating the normal rotation of the atlantoaxial complex. Methods. A consecutive series of 22 patients with odontoid fracture unsuitable for anterior screw fixation were involved in this study. Posterior reduction and fixation without fusion using the C1–C2 screw-rod system was performed. Once fracture healing was obtained, instrumentation was removed. The visual analogue scale of neck pain, neck stiffness, American Spinal Injury Association impairment scale, patient satisfaction, and neck disability index were recorded. The range of motion of C1–C2 in flexion-extension and rotation was calculated. Results. The average age at internal fixation surgery was 40.2 ± 11.3 years. The mean duration of follow-up was 41.8 ± 26.8 months. There were no complications associated with instrumentation. All patients returned to their preoperative work. Fracture healing was observed in 21 patients and the instrumentation was removed. After removing the instrumentation, the visual analogue scale was reduced and neck stiffness were relieved (all P < 0.01). Patient satisfaction and neck disability index had improved (all P < 0.01). The range of motion of C1–C2 returned to 4.75°± 1.62° and 25.70°± 5.51° in flexion-extension and in rotation, respectively. No osteoarthritis was observed at the C1–C2 lateral mass joints. Conclusion. Posterior reduction and temporary fixation using the C1–C2 screw-rod system was an optimal salvage maneuver to anterior screw fixation for odontoid fracture. It could effectively avoid the motion loss of C1–C2 caused by posterior atlantoaxial fusion. Level of Evidence: 3
- 1 February 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (3) , E168-E174
Posterior Reduction and Temporary Fixation for Odontoid Fracture
Study Design. A prospective study. Objective. To evaluate the outcomes of posterior reduction and temporary fixation using the C1–C2 screw-rod system for odontoid fracture unsuitable for anterior screw fixation. Summary of Background Data. Anterior screw fixation has become the most widely used surgical procedure for the stabilization of odontoid fractures. However, if there is any contraindication for anterior fixation, posterior atlantoaxial fusion is preferred, eliminating the normal rotation of the atlantoaxial complex. Methods. A consecutive series of 22 patients with odontoid fracture unsuitable for anterior screw fixation were involved in this study. Posterior reduction and fixation without fusion using the C1–C2 screw-rod system was performed. Once fracture healing was obtained, instrumentation was removed. The visual analogue scale of neck pain, neck stiffness, American Spinal Injury Association impairment scale, patient satisfaction, and neck disability index were recorded. The range of motion of C1–C2 in flexion-extension and rotation was calculated. Results. The average age at internal fixation surgery was 40.2 ± 11.3 years. The mean duration of follow-up was 41.8 ± 26.8 months. There were no complications associated with instrumentation. All patients returned to their preoperative work. Fracture healing was observed in 21 patients and the instrumentation was removed. After removing the instrumentation, the visual analogue scale was reduced and neck stiffness were relieved (all P < 0.01). Patient satisfaction and neck disability index had improved (all P < 0.01). The range of motion of C1–C2 returned to 4.75°± 1.62° and 25.70°± 5.51° in flexion-extension and in rotation, respectively. No osteoarthritis was observed at the C1–C2 lateral mass joints. Conclusion. Posterior reduction and temporary fixation using the C1–C2 screw-rod system was an optimal salvage maneuver to anterior screw fixation for odontoid fracture. It could effectively avoid the motion loss of C1–C2 caused by posterior atlantoaxial fusion. Level of Evidence: 3