Theodoor H. Smit
Research Subjects
Theodoor H. Smit has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Marco N. Helder
VU University Medical Center
7 shared publications- Pieter-Paul A. Vergroesen
Department of Orthopedic Surgery, VU University Medical Center, Amsterdam, The Netherlands
7 shared publications - Kaj S. Emanuel
Department of Orthopaedic Surgery and Sports Medicine, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, The Netherlands
5 shared publications Albert J. van der Veen
Department of Physics and Medical Technology, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam, The Netherlands; MOVE Research Institute Amsterdam, Van der Boechorststraat 7, 1081 BT Amsterdam, The Netherlands
4 shared publicationsBarend J. van Royen
VU University Medical Center
4 shared publications- Idsart Kingma
Department of Human Movement Sciences, Vrije Universiteit, Van der Boechorsstraat 9, 1081BT Amsterdam, the Netherlands; Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, the Netherlands
3 shared publications
Latest Publications
- 1 March 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 70, 4-9
Are axial intervertebral disc biomechanics determined by osmosis?
- 1 March 2018
- Published by Elsevier in Journal of Biomechanics
- Vol. 70, 4-9
Are axial intervertebral disc biomechanics determined by osmosis?
- 1 July 2016
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 24 (7) , 1292-1301
The contribution of collagen fibers to the mechanical compressive properties of the temporomandibular joint disc
- 1 July 2016
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 24 (7) , 1292-1301
The contribution of collagen fibers to the mechanical compressive properties of the temporomandibular joint disc
- 1 April 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (6) , 857-863
The poro-elastic behaviour of the intervertebral disc: A new perspective on diurnal fluid flow
- 1 April 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (6) , 857-863
The poro-elastic behaviour of the intervertebral disc: A new perspective on diurnal fluid flow
- Open Access
- 8 February 2016
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 18 (1) , 41
Response to: ‘A dose–response relationship between severity of disc degeneration and intervertebral disc height in the lumbosacral spine’
- 8 February 2016
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 18 (1) , 41
Open AccessResponse to: ‘A dose–response relationship between severity of disc degeneration and intervertebral disc height in the lumbosacral spine’
- 21 October 2015
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 30 (7) , 983-994
Translational challenges for the development of a novel nucleus pulposus substitute: Experimental results from biomechanical and in vivo studies
Nucleus pulposus replacement therapy could offer a less invasive alternative to restore the function of moderately degenerated intervertebral discs than current potentially destructive surgical procedures. Numerous nucleus pulposus substitutes have already been investigated, to assess their applicability for intradiscal use. Still, the current choice of testing methods often does not lead to efficient translation into clinical application. In this paper, we present the evaluation of a novel nucleus pulposus substitute, consisting of a hydromed core and an electrospun envelope. We performed three mechanical evaluations and an in vivo pilot experiment. Initially, the swelling pressure of the implant was assessed in confined compression. Next, we incorporated the implant into mechanically damaged caprine lumbar intervertebral discs to determine biomechanical segment behaviour in bending and torsion. Subsequently, segments were serially tested in native, damaged and repaired conditions under dynamic axial compressive loading regimes in a loaded disc culture system. Finally, nucleus pulposus substitutes were implanted in a live goat spine using a transpedicular approach. In confined compression, nucleus pulposus samples as well as implants showed some load-bearing capacity, but the implant exhibited a much lower absolute pressure. In bending and torsion, we found that the nucleus pulposus substitute could partly restore the mechanical response of the disc. During dynamic axial compression in the loaded disc culture system, on the other hand, the implant was not able to recover axial compressive behaviour towards the healthy situation. Moreover, the nucleus pulposus substitutes did not remain in place in the in vivo situation but migrated out of the disc area. From these results, we conclude that implants may mimic native disc behaviour in simple mechanical tests, yet fail in other, more realistic set-ups. Therefore, we recommend that biomaterials for nucleus pulposus replacement be tested in testing modalities of increasing complexity and in their relevant anatomical surroundings, for a more reliable prediction of clinical potential.
- 21 October 2015
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 30 (7) , 983-994
Translational challenges for the development of a novel nucleus pulposus substitute: Experimental results from biomechanical and in vivo studies
Nucleus pulposus replacement therapy could offer a less invasive alternative to restore the function of moderately degenerated intervertebral discs than current potentially destructive surgical procedures. Numerous nucleus pulposus substitutes have already been investigated, to assess their applicability for intradiscal use. Still, the current choice of testing methods often does not lead to efficient translation into clinical application. In this paper, we present the evaluation of a novel nucleus pulposus substitute, consisting of a hydromed core and an electrospun envelope. We performed three mechanical evaluations and an in vivo pilot experiment. Initially, the swelling pressure of the implant was assessed in confined compression. Next, we incorporated the implant into mechanically damaged caprine lumbar intervertebral discs to determine biomechanical segment behaviour in bending and torsion. Subsequently, segments were serially tested in native, damaged and repaired conditions under dynamic axial compressive loading regimes in a loaded disc culture system. Finally, nucleus pulposus substitutes were implanted in a live goat spine using a transpedicular approach. In confined compression, nucleus pulposus samples as well as implants showed some load-bearing capacity, but the implant exhibited a much lower absolute pressure. In bending and torsion, we found that the nucleus pulposus substitute could partly restore the mechanical response of the disc. During dynamic axial compression in the loaded disc culture system, on the other hand, the implant was not able to recover axial compressive behaviour towards the healthy situation. Moreover, the nucleus pulposus substitutes did not remain in place in the in vivo situation but migrated out of the disc area. From these results, we conclude that implants may mimic native disc behaviour in simple mechanical tests, yet fail in other, more realistic set-ups. Therefore, we recommend that biomaterials for nucleus pulposus replacement be tested in testing modalities of increasing complexity and in their relevant anatomical surroundings, for a more reliable prediction of clinical potential.
- 1 October 2015
- Published by SAGE Publications in Tissue Engineering Part B: Reviews
- Vol. 21 (5) , 427-437
From Skeletal Development to Tissue Engineering: Lessons from the Micromass Assay
Damage and degeneration of the skeletal elements due to disease, trauma, and aging lead to a significant health and economical burden. To reduce this burden, skeletal tissue engineering strategies aim to regenerate functional bone and cartilage in the adult body. However, challenges still exist. Such challenges involve the identification of the external cues that determine differentiation, how to control chondrocyte hypertrophy, and how to achieve specific tissue patterns and boundaries. To address these issues, it could be insightful to look at skeletal development, a robust morphogenetic process that takes place during embryonic development and is commonly modeled in vitro by the micromass assay. In this review, we investigate what the tissue engineering field can learn from this assay. By comparing embryonic skeletal precursor cells from different anatomic locations and developmental stages in micromass, the external cues that guide lineage commitment can be identified. The signaling pathways regulating chondrocyte hypertrophy, and the cues required for tissue patterning, can be elucidated by combining the micromass assay with genetic, molecular, and engineering tools. The lessons from the micromass assay are limited by two major differences between developmental and regenerative skeletogenesis: cell type and scale. We highlight an important difference between embryonic and adult skeletal progenitor cells, in that adult progenitors are not able to form mesenchymal condensations spontaneously. Also, the mechanisms of tissue patterning need to be adjusted to the larger tissue engineering constructs. In conclusion, mechanistic insights of skeletal tissue generation gained from the micromass model could lead to improved tissue engineering strategies and constructs.
- 1 October 2015
- Published by SAGE Publications in Tissue Engineering Part B: Reviews
- Vol. 21 (5) , 427-437
From Skeletal Development to Tissue Engineering: Lessons from the Micromass Assay
Damage and degeneration of the skeletal elements due to disease, trauma, and aging lead to a significant health and economical burden. To reduce this burden, skeletal tissue engineering strategies aim to regenerate functional bone and cartilage in the adult body. However, challenges still exist. Such challenges involve the identification of the external cues that determine differentiation, how to control chondrocyte hypertrophy, and how to achieve specific tissue patterns and boundaries. To address these issues, it could be insightful to look at skeletal development, a robust morphogenetic process that takes place during embryonic development and is commonly modeled in vitro by the micromass assay. In this review, we investigate what the tissue engineering field can learn from this assay. By comparing embryonic skeletal precursor cells from different anatomic locations and developmental stages in micromass, the external cues that guide lineage commitment can be identified. The signaling pathways regulating chondrocyte hypertrophy, and the cues required for tissue patterning, can be elucidated by combining the micromass assay with genetic, molecular, and engineering tools. The lessons from the micromass assay are limited by two major differences between developmental and regenerative skeletogenesis: cell type and scale. We highlight an important difference between embryonic and adult skeletal progenitor cells, in that adult progenitors are not able to form mesenchymal condensations spontaneously. Also, the mechanisms of tissue patterning need to be adjusted to the larger tissue engineering constructs. In conclusion, mechanistic insights of skeletal tissue generation gained from the micromass model could lead to improved tissue engineering strategies and constructs.
- Top Cited Papers
- 1 July 2015
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 23 (7) , 1057-1070
Mechanics and biology in intervertebral disc degeneration: a vicious circle
- 1 July 2015
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 23 (7) , 1057-1070
Top Cited PapersMechanics and biology in intervertebral disc degeneration: a vicious circle
- 1 May 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (9) , 622-628
A Biodegradable Glue for Annulus Closure
Study Design. A biodegradable glue was biomechanically tested for annulus closure using nondegenerated goat intervertebral discs. Ultimate strength and endurance tests were performed using native and punctured discs as positive and negative controls, respectively. Objective. The aim of this study was to investigate the feasibility and biomechanical properties of a biodegradable glue for annulus closure. Summary of Background Data. There is an unmet clinical need for annulus closure techniques. Isocyanate-terminated tissue glues show potential because they adhere to annulus tissue, have an elastic modulus similar to the annulus, and show limited cytotoxicity to human annulus fibrosus cells. Methods. Three biomechanical tests were performed divided in 2 parts: part 1: ultimate strength tests comparing native, punctured (2.4-mm needle), and glued caprine intervertebral discs (n = 11 per group); part 2: 10 discs per group were subjected to a 10-day ex vivo endurance test of 864,000 load cycles, followed by ultimate strength tests. Outcome parameters include the restoration of strength after puncture, reduction of herniation in the endurance test, and conservation of glue strength after endurance testing. Results. Part 1: The glue partially restored subsidence to failure and yield strength/ultimate strength ratio of intervertebral discs. Part 2: During endurance testing, 40% of punctured discs failed compared with none of the glued discs. Endurance testing did not affect glue strength, and pooling of ultimate strength tests showed that the glue restored ultimate strength, work to failure, and yield strength/ultimate strength to 79%, 75%, and 119% of native values, respectively. Conclusion. A biodegradable isocyanate-terminated glue increases the force at which nucleus protrusion occurs, and it limits herniations during endurance or ultimate strength tests. Biomechanical tests in a bioreactor provide a low-cost assessment for annulus repair strategies; however, the clinical efficacy needs to be further addressed using long-term in vivo studies. Level of Evidence: N/A
- 1 May 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (9) , 622-628
A Biodegradable Glue for Annulus Closure
Study Design. A biodegradable glue was biomechanically tested for annulus closure using nondegenerated goat intervertebral discs. Ultimate strength and endurance tests were performed using native and punctured discs as positive and negative controls, respectively. Objective. The aim of this study was to investigate the feasibility and biomechanical properties of a biodegradable glue for annulus closure. Summary of Background Data. There is an unmet clinical need for annulus closure techniques. Isocyanate-terminated tissue glues show potential because they adhere to annulus tissue, have an elastic modulus similar to the annulus, and show limited cytotoxicity to human annulus fibrosus cells. Methods. Three biomechanical tests were performed divided in 2 parts: part 1: ultimate strength tests comparing native, punctured (2.4-mm needle), and glued caprine intervertebral discs (n = 11 per group); part 2: 10 discs per group were subjected to a 10-day ex vivo endurance test of 864,000 load cycles, followed by ultimate strength tests. Outcome parameters include the restoration of strength after puncture, reduction of herniation in the endurance test, and conservation of glue strength after endurance testing. Results. Part 1: The glue partially restored subsidence to failure and yield strength/ultimate strength ratio of intervertebral discs. Part 2: During endurance testing, 40% of punctured discs failed compared with none of the glued discs. Endurance testing did not affect glue strength, and pooling of ultimate strength tests showed that the glue restored ultimate strength, work to failure, and yield strength/ultimate strength to 79%, 75%, and 119% of native values, respectively. Conclusion. A biodegradable isocyanate-terminated glue increases the force at which nucleus protrusion occurs, and it limits herniations during endurance or ultimate strength tests. Biomechanical tests in a bioreactor provide a low-cost assessment for annulus repair strategies; however, the clinical efficacy needs to be further addressed using long-term in vivo studies. Level of Evidence: N/A
- Open Access
- 15 February 2015
- Published by Springer Nature in European Spine Journal
- Vol. 24 (9) , 1992-2000
Adverse effects of stromal vascular fraction during regenerative treatment of the intervertebral disc: observations in a goat model
Stromal vascular fraction (SVF), an adipose tissue-derived heterogeneous cell mixture containing, among others, multipotent adipose stromal cells (ASCs) and erythrocytes, has proved beneficial for a wide range of applications in regenerative medicine. We sought to establish intervertebral disc (IVD) regeneration by injecting SVF intradiscally during a one-step surgical procedure in an enzymatically (Chondroitinase ABC; cABC) induced goat model of disc degeneration. Unexpectedly, we observed a severe inflammatory response that has not been described before, including massive lymphocyte infiltration, neovascularisation and endplate destruction. A second study investigated two main suspects for these adverse effects: cABC and erythrocytes within SVF. The same destructive response was observed in healthy goat discs injected with SVF, thereby eliminating cABC as a cause. Density gradient removal of erythrocytes and ASCs purified by culturing did not lead to adverse effects. Following these observations, we incorporated an extra washing step in the SVF harvesting protocol. In a third study, we applied this protocol in a one-step procedure to a goat herniation model, in which no adverse responses were observed either. However, upon intradiscal injection of an identically processed SVF mixture into our goat IVD degeneration model during a fourth study, the adverse effects surprisingly occurred again. Despite our quest for the responsible agent, we eventually could not identify the mechanism through which the observed destructive responses occurred. Although we cannot exclude that the adverse effects are species-dependent or model-specific, we advertise caution with the clinical application of autologous SVF injections into the IVD until the responsible agent(s) are identified.
- 15 February 2015
- Published by Springer Nature in European Spine Journal
- Vol. 24 (9) , 1992-2000
Open AccessAdverse effects of stromal vascular fraction during regenerative treatment of the intervertebral disc: observations in a goat model
Stromal vascular fraction (SVF), an adipose tissue-derived heterogeneous cell mixture containing, among others, multipotent adipose stromal cells (ASCs) and erythrocytes, has proved beneficial for a wide range of applications in regenerative medicine. We sought to establish intervertebral disc (IVD) regeneration by injecting SVF intradiscally during a one-step surgical procedure in an enzymatically (Chondroitinase ABC; cABC) induced goat model of disc degeneration. Unexpectedly, we observed a severe inflammatory response that has not been described before, including massive lymphocyte infiltration, neovascularisation and endplate destruction. A second study investigated two main suspects for these adverse effects: cABC and erythrocytes within SVF. The same destructive response was observed in healthy goat discs injected with SVF, thereby eliminating cABC as a cause. Density gradient removal of erythrocytes and ASCs purified by culturing did not lead to adverse effects. Following these observations, we incorporated an extra washing step in the SVF harvesting protocol. In a third study, we applied this protocol in a one-step procedure to a goat herniation model, in which no adverse responses were observed either. However, upon intradiscal injection of an identically processed SVF mixture into our goat IVD degeneration model during a fourth study, the adverse effects surprisingly occurred again. Despite our quest for the responsible agent, we eventually could not identify the mechanism through which the observed destructive responses occurred. Although we cannot exclude that the adverse effects are species-dependent or model-specific, we advertise caution with the clinical application of autologous SVF injections into the IVD until the responsible agent(s) are identified.
- 5 August 2014
- Published by Springer Nature in European Spine Journal
- Vol. 24 (9) , 1935-1943
MRI T2* mapping correlates with biochemistry and histology in intervertebral disc degeneration in a large animal model
To evaluate intervertebral disc (IVD) degeneration and treatments, an objective diagnostic tool is needed. Recently, T2* relaxation time mapping was proposed as a technique to assess early IVD degeneration, yet the correlation with biochemical content and histological features has not been investigated previously. Our objective was to validate T2* mapping for disc degeneration by correlating this technique with accepted parameters of IVD degeneration. Mildly and severely degenerated lumbar discs were obtained from an in vivo large animal study; two healthy goat spines were acquired as control. In total, 48 IVDs were analysed using T2-weighted MRI, T2* relaxation time mapping, biochemical assays, macroscopic and histological scoring. Correlations between variables were expressed with Spearman’s rho (ρ) coefficients. A complete range of degenerative grades were obtained (mean histological grade 2.2, range 0–6). A linear positive correlation was observed between T2* relaxation time and glycosaminoglycan content (ρ = 0.64, p < 0.001). T2* relaxation time decreased linearly with increasing degeneration as assessed with Pfirrmann scoring system (ρ = −0.67, p < 0.001), macroscopic (ρ = −0.33, p < 0.05) and histological (ρ = −0.45, p < 0.05) grading. T2* mapping is an MRI technique for IVD evaluation which allows for measurements on a continuous scale thus minimising observer bias compared to grading systems. Although limited by a small sample size, this study showed a relatively good and linear correlation between T2* relaxation time and accepted parameters of disc degeneration. This suggests that T2* mapping is a promising tool to assess disc degeneration in clinical practice.
- 5 August 2014
- Published by Springer Nature in European Spine Journal
- Vol. 24 (9) , 1935-1943
MRI T2* mapping correlates with biochemistry and histology in intervertebral disc degeneration in a large animal model
To evaluate intervertebral disc (IVD) degeneration and treatments, an objective diagnostic tool is needed. Recently, T2* relaxation time mapping was proposed as a technique to assess early IVD degeneration, yet the correlation with biochemical content and histological features has not been investigated previously. Our objective was to validate T2* mapping for disc degeneration by correlating this technique with accepted parameters of IVD degeneration. Mildly and severely degenerated lumbar discs were obtained from an in vivo large animal study; two healthy goat spines were acquired as control. In total, 48 IVDs were analysed using T2-weighted MRI, T2* relaxation time mapping, biochemical assays, macroscopic and histological scoring. Correlations between variables were expressed with Spearman’s rho (ρ) coefficients. A complete range of degenerative grades were obtained (mean histological grade 2.2, range 0–6). A linear positive correlation was observed between T2* relaxation time and glycosaminoglycan content (ρ = 0.64, p < 0.001). T2* relaxation time decreased linearly with increasing degeneration as assessed with Pfirrmann scoring system (ρ = −0.67, p < 0.001), macroscopic (ρ = −0.33, p < 0.05) and histological (ρ = −0.45, p < 0.05) grading. T2* mapping is an MRI technique for IVD evaluation which allows for measurements on a continuous scale thus minimising observer bias compared to grading systems. Although limited by a small sample size, this study showed a relatively good and linear correlation between T2* relaxation time and accepted parameters of disc degeneration. This suggests that T2* mapping is a promising tool to assess disc degeneration in clinical practice.