Samuel Kadoury
Samuel Kadoury has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Hubert Labelle
Sainte-Justine Hospital Research Centre, Montreal, Canada
3 shared publications Nikos Paragios
2 shared publicationsAlessandro Radaelli
Philips Healthcare (Netherlands)
1 shared publication- Ankur Kapoor
National Institutes of Health, Bethesda, USA
1 shared publication Bart Carelsen
Philips Healthcare (Netherlands)
1 shared publication- Bradford J. Wood
Center for Interventional Oncology, NCI, NIH, Bethesda, MD, USA
1 shared publication
Latest Publications
- 15 December 2016
- Published by Wolters Kluwer Health in Spine
- Vol. 41 (24) , 1903-1907
Geometric Torsion in Adolescent Idiopathic Scoliosis
Consecutive case series analysis. To evaluate the surgical outcomes of patients with thoracic adolescent idiopathic scoliosis (AIS) in relation to different degrees of geometric torsion. AIS is a three-dimensional (3D) deformity of the spine. A 3D classification of AIS, however, remains elusive because there is no widely accepted 3D parameter in the clinical practice. Recently, a new method of estimating geometric torsion has been proposed and detected two potential new 3D subgroups based on geometric torsion values. This is an analysis of 93 patients with Lenke type-1 deformity from our institution. 3D reconstructions were obtained using biplanar radiographs both pre- and postoperatively. Geometric torsion was computed using a novel technique by approximating local arc lengths at the neutral vertebra in the thoracolumbar segment. An inter- and intragroup statistical analysis was performed to compare clinical indices of patients with different torsion values. A qualitative assessment was also performed on each patient by two senior staff surgeons. Statistically significant differences were observed in clinical indices between high (2.85 mm−1) and low torsion (0.83 mm−1) Lenke type 1 subgroups. Preoperatively, the high torsion group showed higher Cobb angle values in the thoracic segment (71.18° vs. 63.74°), as well as higher angulation in the thoracolumbar plane of maximum deformity (67.79° vs. 53.30°). Postoperatively, a statistically significant difference was found in the orientation of the plane of maximum deformity in the thoracolumbar segment between the high and low torsion groups (47.95° vs. 30.03°). Results from the qualitative evaluation of surgical results showed different results between the two staff surgeons. These results suggest a link between preoperative torsion values and surgical outcomes within Lenke type 1 deformities. These results will need to be validated by an independent group, as it is a single-center study. Level of Evidence: 4
- 15 December 2016
- Published by Wolters Kluwer Health in Spine
- Vol. 41 (24) , 1903-1907
Geometric Torsion in Adolescent Idiopathic Scoliosis
Consecutive case series analysis. To evaluate the surgical outcomes of patients with thoracic adolescent idiopathic scoliosis (AIS) in relation to different degrees of geometric torsion. AIS is a three-dimensional (3D) deformity of the spine. A 3D classification of AIS, however, remains elusive because there is no widely accepted 3D parameter in the clinical practice. Recently, a new method of estimating geometric torsion has been proposed and detected two potential new 3D subgroups based on geometric torsion values. This is an analysis of 93 patients with Lenke type-1 deformity from our institution. 3D reconstructions were obtained using biplanar radiographs both pre- and postoperatively. Geometric torsion was computed using a novel technique by approximating local arc lengths at the neutral vertebra in the thoracolumbar segment. An inter- and intragroup statistical analysis was performed to compare clinical indices of patients with different torsion values. A qualitative assessment was also performed on each patient by two senior staff surgeons. Statistically significant differences were observed in clinical indices between high (2.85 mm−1) and low torsion (0.83 mm−1) Lenke type 1 subgroups. Preoperatively, the high torsion group showed higher Cobb angle values in the thoracic segment (71.18° vs. 63.74°), as well as higher angulation in the thoracolumbar plane of maximum deformity (67.79° vs. 53.30°). Postoperatively, a statistically significant difference was found in the orientation of the plane of maximum deformity in the thoracolumbar segment between the high and low torsion groups (47.95° vs. 30.03°). Results from the qualitative evaluation of surgical results showed different results between the two staff surgeons. These results suggest a link between preoperative torsion values and surgical outcomes within Lenke type 1 deformities. These results will need to be validated by an independent group, as it is a single-center study. Level of Evidence: 4
- 15 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8671, 86711I
Towards cone-beam CT thermometry
Temperature monitoring and therefore the final treatment zone achieved during a cone-beam CT (CBCT) guided ablation can prevent overtreatment and undertreatment. A novel method is proposed to detect changes in consecutive CBCT images obtained from projection reconstructions during an ablation procedure. The possibility is explored of using this method to generate thermometry maps from CBCT images, which can be used as an input function for ablation treatment planning. This novel method uses a baseline and an intermittent CBCT scan, which are routinely acquired to confirm the needle position and monitor progress of the ablation. Accurate registration is required and assumed in vitro and ex vivo. A Wronskian change detector algorithm is applied on the compensated images to obtain a difference image between the intermittent and baseline scans. Finally, a thermal map created by applying a calibration determined experimentally is used to obtain the corresponding temperature at each pixel or voxel. We applied Wronskian change detector to detect the difference of two CBCT images, which have low signal to noise ratio, and calibrate Wronskian change model to temperature data using a gel phantom. We tested the temperature mapping with water and gel phantoms as well as pig shoulder. The experimental results show this method can detect temperature change within 5°C for a voxel size of 1mm3 (within clinical relevancy), and by consequence delineate the ablation zone. The preliminary experimental results show that CBCT thermometry is possible and promising, but may require pre-processing, such as registration for motion compensation between the baseline and intermittent scans. Further, quantitative evaluations have to be conducted for validation prior to clinical assessment and translation. CBCT is a widely available technology that could make thermometry clinically practical as an enabling component of iterative ablation treatment planning.
- 15 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8671, 86711I
Towards cone-beam CT thermometry
Temperature monitoring and therefore the final treatment zone achieved during a cone-beam CT (CBCT) guided ablation can prevent overtreatment and undertreatment. A novel method is proposed to detect changes in consecutive CBCT images obtained from projection reconstructions during an ablation procedure. The possibility is explored of using this method to generate thermometry maps from CBCT images, which can be used as an input function for ablation treatment planning. This novel method uses a baseline and an intermittent CBCT scan, which are routinely acquired to confirm the needle position and monitor progress of the ablation. Accurate registration is required and assumed in vitro and ex vivo. A Wronskian change detector algorithm is applied on the compensated images to obtain a difference image between the intermittent and baseline scans. Finally, a thermal map created by applying a calibration determined experimentally is used to obtain the corresponding temperature at each pixel or voxel. We applied Wronskian change detector to detect the difference of two CBCT images, which have low signal to noise ratio, and calibrate Wronskian change model to temperature data using a gel phantom. We tested the temperature mapping with water and gel phantoms as well as pig shoulder. The experimental results show this method can detect temperature change within 5°C for a voxel size of 1mm3 (within clinical relevancy), and by consequence delineate the ablation zone. The preliminary experimental results show that CBCT thermometry is possible and promising, but may require pre-processing, such as registration for motion compensation between the baseline and intermittent scans. Further, quantitative evaluations have to be conducted for validation prior to clinical assessment and translation. CBCT is a widely available technology that could make thermometry clinically practical as an enabling component of iterative ablation treatment planning.
- 31 August 2011
- Published by Springer Nature in European Spine Journal
- Vol. 21 (1) , 40-49
Classification of three-dimensional thoracic deformities in adolescent idiopathic scoliosis from a multivariate analysis
Purpose Understanding how to classify and quantify three-dimensional (3D) spinal deformities remains an open question in adolescent idiopathic scoliosis. The objective of this study was to perform a 3D manifold characterization of scoliotic spines demonstrating thoracic deformations using a novel geometric and intuitive statistical tool to determine patterns in pathological cases. Methods Personalized 3D reconstructions of thoracic (T)/lumbar (L) spines from a cohort of 170 Lenke Type-1 patients were analyzed with a non-linear manifold embedding algorithm in order to reduce the high-dimensionality of the data, using statistical properties of neighbouring spine models. We extracted sub-groups of the data from the underlying manifold structure using an unsupervised clustering algorithm to understand the inherent distribution and determine classes of pathologies which appear from the low-dimensional space. Results For Lenke Type-1 patients, four clusters were detected from the low-dimensional manifold of 3D models: (1) normal kyphosis (T) with hyper-lordosis (L) and high Cobb angles (37 cases), (2) low kyphosis (T) and normal lordosis (L), with high rotation of plane of maximum curvature (55 cases), (3) hypo-kyphotic (T) and hyper-lordosis (L) (21 cases) and (4) hyper-kyphotic (T) with strong vertebral rotation (57 cases). Results show the manifold representation can potentially be useful for classification of 3D spinal pathologies such as idiopathic scoliosis and serve as a tool for understanding the progression of deformities in longitudinal studies. Conclusions Quantitative evaluation illustrates that the complex space of spine variability can be modeled by a low-dimensional manifold and shows the existence of an additional hyper-kyphotic subgroup from the cohort of 3D spine reconstructions of Lenke Type-1 patients when compared with previous findings on the 3D classification of spinal deformities.
- 31 August 2011
- Published by Springer Nature in European Spine Journal
- Vol. 21 (1) , 40-49
Classification of three-dimensional thoracic deformities in adolescent idiopathic scoliosis from a multivariate analysis
Purpose Understanding how to classify and quantify three-dimensional (3D) spinal deformities remains an open question in adolescent idiopathic scoliosis. The objective of this study was to perform a 3D manifold characterization of scoliotic spines demonstrating thoracic deformations using a novel geometric and intuitive statistical tool to determine patterns in pathological cases. Methods Personalized 3D reconstructions of thoracic (T)/lumbar (L) spines from a cohort of 170 Lenke Type-1 patients were analyzed with a non-linear manifold embedding algorithm in order to reduce the high-dimensionality of the data, using statistical properties of neighbouring spine models. We extracted sub-groups of the data from the underlying manifold structure using an unsupervised clustering algorithm to understand the inherent distribution and determine classes of pathologies which appear from the low-dimensional space. Results For Lenke Type-1 patients, four clusters were detected from the low-dimensional manifold of 3D models: (1) normal kyphosis (T) with hyper-lordosis (L) and high Cobb angles (37 cases), (2) low kyphosis (T) and normal lordosis (L), with high rotation of plane of maximum curvature (55 cases), (3) hypo-kyphotic (T) and hyper-lordosis (L) (21 cases) and (4) hyper-kyphotic (T) with strong vertebral rotation (57 cases). Results show the manifold representation can potentially be useful for classification of 3D spinal pathologies such as idiopathic scoliosis and serve as a tool for understanding the progression of deformities in longitudinal studies. Conclusions Quantitative evaluation illustrates that the complex space of spine variability can be modeled by a low-dimensional manifold and shows the existence of an additional hyper-kyphotic subgroup from the cohort of 3D spine reconstructions of Lenke Type-1 patients when compared with previous findings on the 3D classification of spinal deformities.
- 1 August 2011
- Published by Elsevier in Medical Image Analysis
- Vol. 15 (4) , 426-437
Automatic inference of articulated spine models in CT images using high-order Markov Random Fields
- 1 August 2011
- Published by Elsevier in Medical Image Analysis
- Vol. 15 (4) , 426-437
Automatic inference of articulated spine models in CT images using high-order Markov Random Fields
- 1 January 2010
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 13, 579-586
Nonlinear Embedding towards Articulated Spine Shape Inference Using Higher-Order MRFs
In this paper we introduce a novel approach for inferring articulated spine models from images. A low-dimensional manifold embedding is created from a training set of prior mesh models to establish the patterns of global shape variations. Local appearance is captured from neighborhoods in the manifold once the overall representation converges. Inference with respect to the manifold and shape parameters is performed using a Markov Random Field (MRF). Singleton and pairwise potentials measure the support from the data and shape coherence from neighboring models respectively, while higher-order cliques encode geometrical modes of variation for local vertebra shape warping. Optimization of model parameters is achieved using efficient linear programming and duality. The resulting model is geometrically intuitive, captures the statistical distribution of the underlying manifold and respects image support in the spatial domain. Experimental results on spinal column geometry estimation from CT demonstrate the approach’s potential.
- 1 January 2010
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 13, 579-586
Nonlinear Embedding towards Articulated Spine Shape Inference Using Higher-Order MRFs
In this paper we introduce a novel approach for inferring articulated spine models from images. A low-dimensional manifold embedding is created from a training set of prior mesh models to establish the patterns of global shape variations. Local appearance is captured from neighborhoods in the manifold once the overall representation converges. Inference with respect to the manifold and shape parameters is performed using a Markov Random Field (MRF). Singleton and pairwise potentials measure the support from the data and shape coherence from neighboring models respectively, while higher-order cliques encode geometrical modes of variation for local vertebra shape warping. Optimization of model parameters is achieved using efficient linear programming and duality. The resulting model is geometrically intuitive, captures the statistical distribution of the underlying manifold and respects image support in the spatial domain. Experimental results on spinal column geometry estimation from CT demonstrate the approach’s potential.
- 29 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (7) , 1663-1675
Self-Calibration of Biplanar Radiographic Images Through Geometric Spine Shape Descriptors
This paper presents a novel self-calibration method of an X-ray scene applied for the 3-D reconstruction of the scoliotic spine. Current calibration techniques either use a cumbersome calibration apparatus or depend on manually identified landmarks to determine the geometric configuration, thus limiting routine clinical evaluation. The proposed approach uses high-level information automatically extracted from biplanar X-rays to solve the radiographic scene parameters. We first present a segmentation method that takes into account the variable appearance and geometry of a scoliotic spine in order to isolate and extract the silhouettes of the anterior vertebral body. By incorporating prior anatomical information through a Bayesian formulation of the morphological distribution, a multiscale spine segmentation framework is proposed for scoliotic patients. An iterative nonlinear optimization procedure, integrating a 3-D visual hull reconstruction and geometrical torsion properties of the spine, is then applied to globally refine the geometrical parameters of the 3-D viewing scene and obtain the optimal 3-D reconstruction. An experimental comparison with data provided from reference synthetic models yields similar accuracy on the retroprojection of low-level primitives such as anatomical landmarks identified on each vertebra (2.2 mm). Results obtained from a clinical validation on 60 pairs of uncalibrated digitized X-rays of adolescents with scoliosis show that the 3-D reconstructions from the new system offer geometrically accurate models with insignificant differences for 3-D clinical indexes commonly used in the evaluation of spinal deformities. The reported experiments demonstrate a viable and accurate alternative to previous reconstruction techniques, offering the first automatic approach for routine 3-D clinical assessment in radiographic suites.
- 29 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (7) , 1663-1675
Self-Calibration of Biplanar Radiographic Images Through Geometric Spine Shape Descriptors
This paper presents a novel self-calibration method of an X-ray scene applied for the 3-D reconstruction of the scoliotic spine. Current calibration techniques either use a cumbersome calibration apparatus or depend on manually identified landmarks to determine the geometric configuration, thus limiting routine clinical evaluation. The proposed approach uses high-level information automatically extracted from biplanar X-rays to solve the radiographic scene parameters. We first present a segmentation method that takes into account the variable appearance and geometry of a scoliotic spine in order to isolate and extract the silhouettes of the anterior vertebral body. By incorporating prior anatomical information through a Bayesian formulation of the morphological distribution, a multiscale spine segmentation framework is proposed for scoliotic patients. An iterative nonlinear optimization procedure, integrating a 3-D visual hull reconstruction and geometrical torsion properties of the spine, is then applied to globally refine the geometrical parameters of the 3-D viewing scene and obtain the optimal 3-D reconstruction. An experimental comparison with data provided from reference synthetic models yields similar accuracy on the retroprojection of low-level primitives such as anatomical landmarks identified on each vertebra (2.2 mm). Results obtained from a clinical validation on 60 pairs of uncalibrated digitized X-rays of adolescents with scoliosis show that the 3-D reconstructions from the new system offer geometrically accurate models with insignificant differences for 3-D clinical indexes commonly used in the evaluation of spinal deformities. The reported experiments demonstrate a viable and accurate alternative to previous reconstruction techniques, offering the first automatic approach for routine 3-D clinical assessment in radiographic suites.