SLSheng Lu

Sheng Lu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sheng Lu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Yong Q. Xu

    From the *Department of Orthopedics, Kunming General Hospital, PLA, Kunming, China; †Department of Orthopedics and Traumatology, University of Hong Kong, Hong Kong; ‡Department of Rehabilitation Medicine, Fujian Medical University, Fuzhou, China; §Department of Anatomy, the South China University, HenYang, China; and ¶Department of Orthopedics, the First Hospital Affiliated to the Inner Mongolia Medical College, Hohhot'Inner Mongolia Autonomous Region, China

    3 shared publications
  • Dong P. Li

    From the *Department of Orthopedics, Kunming General Hospital, PLA, Kunming, China; †Department of Orthopedics and Traumatology, University of Hong Kong, Hong Kong; ‡Department of Rehabilitation Medicine, Fujian Medical University, Fuzhou, China; §Department of Anatomy, the South China University, HenYang, China; and ¶Department of Orthopedics, the First Hospital Affiliated to the Inner Mongolia Medical College, Hohhot'Inner Mongolia Autonomous Region, China

    2 shared publications
  • Guo P. Chen

    From the *Department of Orthopedics, Kunming General Hospital, PLA, Kunming, China; †Department of Orthopedics and Traumatology, University of Hong Kong, Hong Kong; ‡Department of Rehabilitation Medicine, Fujian Medical University, Fuzhou, China; §Department of Anatomy, the South China University, HenYang, China; and ¶Department of Orthopedics, the First Hospital Affiliated to the Inner Mongolia Medical College, Hohhot'Inner Mongolia Autonomous Region, China

    2 shared publications
  • Hai Guo

    Department of Orthopedics, Kunming General Hospital, Kunming, China

    2 shared publications
  • Ji H. Shi

    From the *Department of Orthopedics, Kunming General Hospital, PLA, Kunming, China; †Department of Orthopedics and Traumatology, University of Hong Kong, Hong Kong; ‡Department of Rehabilitation Medicine, Fujian Medical University, Fuzhou, China; §Department of Anatomy, the South China University, HenYang, China; and ¶Department of Orthopedics, the First Hospital Affiliated to the Inner Mongolia Medical College, Hohhot'Inner Mongolia Autonomous Region, China

    2 shared publications
  • Ji-Hong Shi

    Kunming General Hospital, Chengdu Military Region, PLA

    2 shared publications

Latest Publications

  • Open Access

    Clinical anatomy and 3D virtual reconstruction of the lumbar plexus with respect to lumbar surgery

    by Sheng Lu, Shan Chang, Yuan-Zhi Zhang, Zi-Hai Ding, Xin Ming Xu, Yong-Qing Xu

    Background: Exposure of the anterior or lateral lumbar via the retroperitoneal approach easily causes injuries to the lumbar plexus. Lumbar plexus injuries which occur during anterior or transpsoas lumbar spine exposure and placement of instruments have been reported. This study aims is to provide more anatomical data and surgical landmarks in operations concerning the lumbar plexus in order to prevent lumbar plexus injuries and to increase the possibility of safety in anterior approach lumbar surgery. Methods: To study the applied anatomy related to the lumbar plexus of fifteen formaldehyde-preserved cadavers, Five sets of Virtual Human (VH) data set were prepared and used in the study. Three-dimensional (3D) computerized reconstructions of the lumbar plexus and their adjacent structures were conducted from the VH female data set. Results: The order of lumbar nerves is regular. From the anterior view, lumbar plexus nerves are arranged from medial at L5 to lateral at L2. From the lateral view, lumbar nerves are arranged from ventral at L2 to dorsal at L5. The angle of each nerve root exiting outward to the corresponding intervertebral foramen increases from L1 to L5. The lumbar plexus nerves are observed to be in close contact with transverse processes (TP). All parts of the lumbar plexus were located by sectional anatomy in the dorsal third of the psoas muscle. Thus, access to the psoas major muscle at the ventral 2/3 region can safely prevent nerve injuries. 3D reconstruction of the lumbar plexus based on VCH data can clearly show the relationships between the lumbar plexus and the blood vessels, vertebral body, kidney, and psoas muscle. Conclusion: The psoas muscle can be considered as a surgical landmark since incision at the ventral 2/3 of the region can prevent lumbar plexus injuries for procedures requiring exposure of the lateral anterior of the lumbar. The transverse process can be considered as a landmark and reference in surgical operations by its relative position to the lumbar plexus. 3D reconstructions of the lumbar plexus based on VCH data provide a virtual morphological basis for anterior lumbar surgery.


  • A Novel Patient-Specific Navigational Template for Cervical Pedicle Screw Placement

    by Sheng Lu, Yong Q. Xu, William W. Lu, Guo X. Ni, Yan B. Li, Ji H. Shi, Dong P. Li, Guo P. Chen, Yu B. Chen, Yuan Z. Zhang

    Study Design. Prospective trial. Objective. To develop and validate a novel, patient-specific navigational template for cervical pedicle placement. Summary of Background Data. Owing to the narrow bony anatomy and the proximity to the vertebral artery and the spinal cord, cervical instrumentation procedures demand the need for a precise technique for screw placement. Patient. Specific drill template with preplanned trajectory has been thought as a promising solution for cervical pedicle screw placement. Methods. Patients with cervical spinal pathology (n = 25) requiring instrumentation were recruited. Volumetric CT scan was performed on each desired cervical vertebra and a 3-dimensional reconstruction model was generated from the scan data. Using reverse engineering technique, the optimal screw size and orientation were determined and a drill template was designed with a surface that is the inverse of the posterior vertebral surface. The drill template and its corresponding vertebra were manufactured using rapid prototyping technique and tested for violations. The navigational template was sterilized and used intraoperatively to assist with the placement of cervical screws. In total, 88 screws were inserted into levels C2–C7 with 2 to 6 screw in each patient. After surgery, the positions of the pedicle screws were evaluated using CT scan and graded for validation. Results. This method showed its ability to customize the placement and the size of each screw based on the unique morphology of the cervical vertebra. In all the cases, it was relatively very easy to manually place the drill template on the lamina of the vertebral body during the surgery. The required time between fixation of the template to the lamina and insertion of the pedicle screws was about 80 seconds. Of the 88 screws, 71 screws had no deviation and 14 screws had deviation <2 mm, 1 screw had a deviation between 2 to 4 mm and there were no misplacements. Fluoroscopy was used only once for every patient after the insertion of all the pedicle screws. Conclusion. The authors have developed a novel patient-specific navigational template for cervical pedicle screw placement with good applicability and high accuracy. This method significantly reduces the operation time and radiation exposure for the members of the surgical team. The potential use of such a navigational template to insert cervical pedicle screws is promising. This technique has been clinically validated to provide an accurate trajectory for pedicle screw placement in the cervical spine.


  • A novel computer-assisted drill guide template for placement of C2 laminar screws

    by Sheng Lu, Yong Q. Xu, Yuan Z. Zhang, Le Xie, Hai Guo, Dong P. Li

    The present method of C2 laminar screw placement relies on anatomical landmarks for screw placement. Placement of C2 laminar screws using drill template has not been described in the literature. The authors reported on their experience with placement of C2 laminar screws using a novel computer-assisted drill guide template in nine patients undergoing posterior occipito-cervical fusion. CT scan of C2 vertebrae was performed. 3D model of C2 vertebrae was reconstructed by software MIMICS 10.01. The 3D vertebral model was then exported in STL format, and opened in a workstation running software UG imageware12.0 for determining the optimal laminar screw size and orientation. A virtual navigational template was established according to the laminar anatomic trait. The physical vertebrae and navigational template were manufactured using rapid prototyping. The navigational template was sterilized and used intraoperative to assist the placement of laminar screw. Overall, 19 C2 laminar screws were placed and the accuracy of screw placement was confirmed with postoperative X-ray and CT scanning. There were not complications of related screws insertion. Average follow-up was 9 months (range 4–13 months), 77.8% of the patients exhibited improvement in their myelopathic symptoms; in 22.2% the symptoms were unchanged. Postoperative computed tomographic (CT) scanning was available for allowing the evaluation of placement of thirteen C2 laminar screws, all of which were in good position with no spinal canal violation. This study shows a patient-specific template technique that is easy to use, can simplify the surgical act and generates highly accurate C2 laminar screw placement. Advantages of this technology over traditional techniques include planning of the screw trajectory is done completely in the presurgical period as well as the ability to size the screw to the patient’s anatomy.


  • A novel computer‐assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study

    by Sheng Lu, Yong Q. Xu, Yuan Z. Zhang, Yan B. Li, LE Xie, Ji H. Shi, Hai Guo, Guo P. Chen, Yu B Chen

    Background: The great accuracy of computer‐assisted operative systems for pedicle screw insertion makes them highly desirable for spinal surgeries. However, computer‐assisted pedicle screw placement is expensive, and the learning curve for these techniques is significant. We have developed a novel method of spinal pedicle stereotaxy by reverse engineering (RE) and rapid prototyping (RP) and have validated the method's accuracy by cadaveric and clinical study.Methods: A volumetric CT scan was performed on each desired lumbar vertebra and a three‐dimensional (3D) reconstruction model was generated with MIMICS 10.1, while the optimal screw size and orientation were determined using UG Imageware 12.1. A drill template was created using UG Imageware 12.1, with a surface that is the inverse of the vertebral surface. The drill template and its corresponding vertebra were manufactured using RP. The method was tested on six cadavers without any fluoroscopic control at surgery. Eventually, the technology was applied in six clinical cases.Results: The accuracy of the drill template was confirmed by preoperatively drilling the screw trajectory into the vertebra biomodel. In the cadaveric experiment, 36 pedicle screws were inserted and no pedicle perforation was observed by postoperative CT scan. In the six clinical patients, the best fit for positioning the template was easily found manually during the operation. The required time between fixation of the template to the lamina and insertion of the pedicle screw into each segment (one or two vertebrae) was 1–2 min. In total, 22 screws were inserted into T12‐L5, with two to four screws/patient. No misplacement occurred using the individual templates. Fluoroscopy was used only once after all the pedicle screws had been inserted. The method significantly reduces operation time and radiation exposure for the members of the surgical team.Conclusions: The authors have developed a novel computer‐assisted drill template for lumbar pedicle screw placement. This method has shown its ability to customize the placement and size of each screw, based on the unique morphology of the lumbar vertebra. The potential use of drill templates to place lumbar pedicle screws is promising. Copyright © 2009 John Wiley & Sons, Ltd.


  • Clinical anatomy study of autonomic nerve with respective to the anterior approach lumbar surgery

    by Sheng Lu, Yong-Qing Xu, Shan Chang, Yuan-Zhi Zhang, Ji-Hong Shi, Zi-Hai Ding, Zhong-Hua Li, Shi-Zhen Zhong

    Male genital dysfunction was recognized as a complication following anterior approach lumbar surgery. Disruption of efferent sympathetic pathways such as the abdominal aortic plexus (AAP) and superior hypogastric plexus (SHP) which lied pre-abdominal aorta and iliac artery had been thought as the main reason. Though there were some clinical reports of retrograde ejaculation, the applied anatomic study of the autonomic nerve anterior to the lumbar was little. The purpose was to find out a lumbar surgery approach which was ejaculation preservation through the detailed study of the anatomy and histology observation of the autonomic nerve anterior to the lumbar vertebrae.


    • 1 May 2008
      • Vol. 46  (9) , 647-9

    [The clinic anatomy of lumbar plexus in the lumbar anterolaterally approach minimally invasive surgery].

    by Sheng Lu, Yong-Qing Xu, Zi-Hai Ding, Ji-Hong Shi, Yue-Li Wang, Shi-Zhen Zhong

    To provide anatomic data for reducing lumbar plexus nerve injury. The applied anatomy of lumbar plexus was studied by 15 formaldehyde-preserved cadavers, two groups of sectional images of lumbar segment and three series of virtual chinese human dataset. Arrangement of the lumbar nerve was regular. From anterior view, lumbar plexus nerve arranged from lateral to medial from L2 to L5; from lateral view, lumbar nerve arrange from ventral to dorsal from L2 to L5. The angle degree between the lumbar nerve and lumbar increased from L1 to L5. The lumbar plexus nerve was revealed to be in close contact with transverse process. By sectional anatomy, all parts of the lumbar plexus nerve were located in the dorsal third of the psoas major. The safety zone of the psoas major to prevent nerve injuries was ventrally 2/3. Psoas major can be considered as surgery landmark when expose the lateral anterior of lumbar by incising the psoas muscle. Incising the psoas muscle ventral 2/3 can prevent lumbar plexus injury. Transverse process can be considered as landmark for the position of lumbar plexus in operation.