Janalt Damstra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Janalt Damstra has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Yijin Ren
7 shared publicationsZacharias Fourie
6 shared publicationsJames J.R. Huddleston Slater
Assistant professor, Department of Oral Health Care and Clinical Epidemiology Academic Centre for Oral Health, Groningen, The Netherlands
3 shared publications- Yijin Ren
Department of Orthodontics, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
3 shared publications - Zacharias Fourie
University Medical Center Groningen, University of Groningen, Department of Orthodontics, Hanzeplein 1, 9700 RB Groningen, The Netherlands
3 shared publications Barbara Constance Maria Oosterkamp
1 shared publication
Latest Publications
- 1 April 2012
- Vol. 21 (2) , 220-31
Application of cone beam computed tomography in facial imaging science.
The use of three-dimensional (3D) methods for facial imaging has increased significantly over the past years. Traditional 2D imaging has gradually being replaced by 3D images in different disciplines, particularly in the fields of orthodontics, maxillofacial surgery, plastic and reconstructive surgery, neurosurgery and forensic sciences. In most cases, 3D facial imaging overcomes the limitations of traditional 2D methods and provides the clinician with more accurate information regarding the soft-tissues and the underlying skeleton. The aim of this study was to review the types of imaging methods used for facial imaging. It is important to realize the difference between the types of 3D imaging methods as application and indications thereof may differ. Since 3D cone beam computed tomography (CBCT) imaging will play an increasingly important role in orthodontics and orthognathic surgery, special emphasis should be placed on discussing CBCT applications in facial evaluations.
- 1 April 2012
- Vol. 21 (2) , 220-31
Application of cone beam computed tomography in facial imaging science.
The use of three-dimensional (3D) methods for facial imaging has increased significantly over the past years. Traditional 2D imaging has gradually being replaced by 3D images in different disciplines, particularly in the fields of orthodontics, maxillofacial surgery, plastic and reconstructive surgery, neurosurgery and forensic sciences. In most cases, 3D facial imaging overcomes the limitations of traditional 2D methods and provides the clinician with more accurate information regarding the soft-tissues and the underlying skeleton. The aim of this study was to review the types of imaging methods used for facial imaging. It is important to realize the difference between the types of 3D imaging methods as application and indications thereof may differ. Since 3D cone beam computed tomography (CBCT) imaging will play an increasingly important role in orthodontics and orthognathic surgery, special emphasis should be placed on discussing CBCT applications in facial evaluations.
- 1 December 2011
- Vol. 20 (6) , 662-8
Practical limitations of cone-beam computed tomography in 3D cephalometry.
3D cone beam computed tomography (CBCT) images offer a unique and new appreciation of the anatomical structures and underlying anomalies not possible with conventional radiographs. However, in almost all aspects of CBCT imaging, from utilization to application, inherent limitations and pitfalls exist. Importantly, these inherent limitations and pitfalls have practical implications which need to be addressed before the potential of this technology can be fully realized. The purpose of this review was to explore the current limitations and pitfalls associated with CBCT imaging to allow for better and more accurate understanding of the possibilities this imaging modality could offer, particularly pertaining to 3D cephalometry.
- 1 December 2011
- Vol. 20 (6) , 662-8
Practical limitations of cone-beam computed tomography in 3D cephalometry.
3D cone beam computed tomography (CBCT) images offer a unique and new appreciation of the anatomical structures and underlying anomalies not possible with conventional radiographs. However, in almost all aspects of CBCT imaging, from utilization to application, inherent limitations and pitfalls exist. Importantly, these inherent limitations and pitfalls have practical implications which need to be addressed before the potential of this technology can be fully realized. The purpose of this review was to explore the current limitations and pitfalls associated with CBCT imaging to allow for better and more accurate understanding of the possibilities this imaging modality could offer, particularly pertaining to 3D cephalometry.
- 1 December 2011
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 140 (6) , 886-894
Combined 3-dimensional and mirror-image analysis for the diagnosis of asymmetry
- 1 December 2011
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 140 (6) , 886-894
Combined 3-dimensional and mirror-image analysis for the diagnosis of asymmetry
- 30 September 2011
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 140 (3) , e107-e114
Reliability and the smallest detectable difference of measurements on 3-dimensional cone-beam computed tomography images
- 30 September 2011
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 140 (3) , e107-e114
Reliability and the smallest detectable difference of measurements on 3-dimensional cone-beam computed tomography images
- 31 July 2011
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 49 (5) , 392-395
Comparison between two-dimensional and midsagittal three-dimensional cephalometric measurements of dry human skulls
- 31 July 2011
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 49 (5) , 392-395
Comparison between two-dimensional and midsagittal three-dimensional cephalometric measurements of dry human skulls
- Open Access
- 31 March 2011
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 35 (1) , 45-50
Evaluation and comparison of postero-anterior cephalograms and cone-beam computed tomography images for the detection of mandibular asymmetry
The aim of this study was to evaluate and compare postero-anterior (PA) cephalograms and cone-beam computed tomography (CBCT) images for the detection of mandibular asymmetry. Six asymmetric anonymous dry human skulls with visible chin deviation were available for this study. Metallic markers were glued on the anatomical landmarks to avoid identification error. PA cephalograms and CBCT scans were made by means of a standardized set-up. Each scan and cephalogram was measured three times by a single observer and the means used for analysis. Asymmetry was defined by the subtraction of the left side and right side measurements. CBCT was reliable [intraclass correlation coefficient (ICC) > 0.957] and very accurate (within 0.5 mm) in detection of all asymmetry. PA cephalograms were not accurate in detection of asymmetry of the mandibular ramus length, the mandibular body length, and the total mandibular length. PA cephalograms were the least reliable in determining the mandibular body length asymmetry (ICC = 0.686). The use of CBCT to detect mandibular asymmetry was validated with this study. CBCT images are very reliable and accurate for the detection of asymmetry and should be considered over conventional PA cephalometry when a chin deviation is present.
- 31 March 2011
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 35 (1) , 45-50
Open AccessEvaluation and comparison of postero-anterior cephalograms and cone-beam computed tomography images for the detection of mandibular asymmetry
The aim of this study was to evaluate and compare postero-anterior (PA) cephalograms and cone-beam computed tomography (CBCT) images for the detection of mandibular asymmetry. Six asymmetric anonymous dry human skulls with visible chin deviation were available for this study. Metallic markers were glued on the anatomical landmarks to avoid identification error. PA cephalograms and CBCT scans were made by means of a standardized set-up. Each scan and cephalogram was measured three times by a single observer and the means used for analysis. Asymmetry was defined by the subtraction of the left side and right side measurements. CBCT was reliable [intraclass correlation coefficient (ICC) > 0.957] and very accurate (within 0.5 mm) in detection of all asymmetry. PA cephalograms were not accurate in detection of asymmetry of the mandibular ramus length, the mandibular body length, and the total mandibular length. PA cephalograms were the least reliable in determining the mandibular body length asymmetry (ICC = 0.686). The use of CBCT to detect mandibular asymmetry was validated with this study. CBCT images are very reliable and accurate for the detection of asymmetry and should be considered over conventional PA cephalometry when a chin deviation is present.
- Open Access
- 27 January 2011
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 16 (1) , 285-294
A three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry
Morphometric methods are used in biology to study object symmetry in living organisms and to determine the true plane of symmetry. The aim of this study was to determine if there are clinical differences between three-dimensional (3D) cephalometric midsagittal planes used to describe craniofacial asymmetry and a true symmetry plane derived from a morphometric method based on visible facial features. The sample consisted of 14 dry skulls (9 symmetric and 5 asymmetric) with metallic markers which were imaged with cone-beam computed tomography. An error study and statistical analysis were performed to validate the morphometric method. The morphometric and conventional cephalometric planes were constructed and compared. The 3D cephalometric planes constructed as perpendiculars to the Frankfort horizontal plane resembled the morphometric plane the most in both the symmetric and asymmetric groups with mean differences of less than 1.00 mm for most variables. However, the standard deviations were often large and clinically significant for these variables. There were clinically relevant differences (>1.00 mm) between the different 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features. The difference between 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features were clinically relevant. Care has to be taken using cephalometric midsagittal planes for diagnosis and treatment planning of craniofacial asymmetry as they might differ from the true plane of symmetry as determined by morphometrics.
- 27 January 2011
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 16 (1) , 285-294
Open AccessA three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry
Morphometric methods are used in biology to study object symmetry in living organisms and to determine the true plane of symmetry. The aim of this study was to determine if there are clinical differences between three-dimensional (3D) cephalometric midsagittal planes used to describe craniofacial asymmetry and a true symmetry plane derived from a morphometric method based on visible facial features. The sample consisted of 14 dry skulls (9 symmetric and 5 asymmetric) with metallic markers which were imaged with cone-beam computed tomography. An error study and statistical analysis were performed to validate the morphometric method. The morphometric and conventional cephalometric planes were constructed and compared. The 3D cephalometric planes constructed as perpendiculars to the Frankfort horizontal plane resembled the morphometric plane the most in both the symmetric and asymmetric groups with mean differences of less than 1.00 mm for most variables. However, the standard deviations were often large and clinically significant for these variables. There were clinically relevant differences (>1.00 mm) between the different 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features. The difference between 3D cephalometric midsagittal planes and the true plane of symmetry determined by the visible facial features were clinically relevant. Care has to be taken using cephalometric midsagittal planes for diagnosis and treatment planning of craniofacial asymmetry as they might differ from the true plane of symmetry as determined by morphometrics.
- 1 November 2010
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 138 (5) , 546.e1-546.e8
Reliability and the smallest detectable differences of lateral cephalometric measurements
- 1 November 2010
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 138 (5) , 546.e1-546.e8
Reliability and the smallest detectable differences of lateral cephalometric measurements
- 1 April 2010
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 48 (3) , 236-238
Simple technique to achieve a natural position of the head for cone beam computed tomography
- 1 April 2010
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 48 (3) , 236-238
Simple technique to achieve a natural position of the head for cone beam computed tomography
- 1 January 2010
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 137 (1) , 16.e1-16.e6
Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes
- 1 January 2010
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 137 (1) , 16.e1-16.e6
Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes